BIOE 220/RAD 220 REVIEW SESSION 3 February 6, 2011.

Slides:



Advertisements
Similar presentations
Chapter3 Pulse-Echo Ultrasound Instrumentation
Advertisements

Computers and Computed Tomography
Image Reconstruction.
* NEAR ZONE is the nearest area to the transducer & it always has the same diameter of the transducer, BUT if the transducer: Linear the near zone length.
I2 Medical imaging.
BIOE 220/RAD 220 REVIEW SESSION 3 February 6, 2011.
Foundations of Medical Ultrasonic Imaging
BIOE 220/RAD 220 REVIEW SESSION January 30, 2011.
إعداد : أ. بلسم فهد صوفي 1 Ultrasound in Medicine Ch.3 Ultrasound pictures of the body.
Parameters and Trade-offs
Advanced Biomedical Imaging Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University Lecture 6 Basic physical principles of.
Handbook of Medical Informatics
Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc.
إعداد : أ. بلسم فهد صوفي،،،المصدر:محاضرات د.حنان 1 Ultrasound in Medicine Ch.4 Ultrasound pictures of the body.
Resident Physics Lectures
Pegasus Lectures, Inc. COPYRIGHT 2006 Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc. Ultrasound Physics & Instrumentation 4 th Edition.
PS Finish Light Color Uses of Electromagnetic spectrum.
Ultrasound Dr.mervat mostafa.
Hospital Physics Group
Pegasus Lectures, Inc. Volume II Companion Presentation Frank Miele Pegasus Lectures, Inc. Ultrasound Physics & Instrumentation 4 th Edition.
Basic Physics of Ultrasound Beth Baughman DuPree M.D. FACS Medical Director Breast Health Program Holy Redeemer Health System 2011.
Basic Physics of Ultrasound
ECE 501 Introduction to BME
Ultrasound Medical Imaging Imaging Science Fundamentals.
Ultrasound Imaging Atam Dhawan.
THE ULTRASOUND IMAGE: GENERATION AND DISPLAY
Ultrasound Physics Sound is a mechanical, longitudinal wave that travels in a straight line Sound requires a medium through which to travel Ultrasound.
Medical Imaging Technology
3/13/2009IB Physics HL 21 Ultrasound Medical Imaging Physics – IB Objectives I.2.7Describe the principles of the generation and the detection of ultrasound.
Doppler echocardiography & Magnetic Resonance Imaging.
Resident Categorical Course
RT 4912 Review (A) Rex T. Christensen MHA RT (R) (MR) (CT) (ARRT) CIIP.
Imaging Anatomy of the CNS
Chapter 13 - Sound 13.1 Sound Waves.
US FUNDAMENTALS: B-MODE AND DOPPLER MACHINE SETTINGS.
Medical Physics Unit Summary. Diagnostic Techniques  Ultrasound  Endoscopes (Fibrescopes)  X-ray imaging  Computed Axial Tomography (CT)  Magnetic.
February 15 You will take a few notes about sound Then you will have some time to finish up the work from yesterday and/or the wave calculations.
Resident Physics Lectures
Display of Motion & Doppler Ultrasound
Sarah Gillies Ultrasound Sarah Gillies
Resident Physics Lectures
4-Jun-161 ULTRASOUND IMAGING Lec 1: Introduction Ultrasonic Field Wave fundamentals. Intensity, power and radiation pressure.
Anatomy and Physiology
Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc.
Biological Measurement 1 BIOE 571
Magnetic Resonance Imaging (MRI). The Components: A magnet which produces a very powerful uniform magnetic field. A magnet which produces a very powerful.
Ultrasound Basis Michel Slama Amiens.
Artifacts Ultrasound Physics George David, M.S.
PSF What is PSF 1way/2way PSFs PSFs for continious & discrete apertures.
Ultrasound Learning Objectives: Describe the properties of ultrasound;
Sound and Hearing Chapter 17 Section Four. Science Journal Entry 35 Compare and contrast reflection, refraction and diffraction.
 Ultrasound waves are longitudinal with high frequencies ( ≈ > 20,000 Hz, though medical Ultrasound is between 1 to 15 MHz.)  When an ultrasound reaches.
What’s in the pictures?.
Mirrors and Refraction Chapter , Mirrors If a candle flame is placed in front of a plane (flat) mirror, rays of light from the candle.
MAGNETIC RESONANCE IMAGING by PRADEEP V.EPAKAYAL. Mem.no L.
Ultrasound Physics Image Formation ‘97. Real-time Scanning Each pulse generates one line Except for multiple focal zones frame one frame consists of many.
Ultrasound Physics Image Formation ‘97.
Resident Physics Lectures
Light.
Impact of Obesity on Medical Imaging and Image-Guided Intervention
Ultrasound Physics Image Formation ‘97.
Ultrasound.
Ultrasound.
How MRI Works Connor Schentag.
Review of Ultrasonic Imaging
Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc.
Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc.
MRI: From Protons to Pixels
T2 Relaxation Time T2 relaxation time is defined as the time needed to dephase up to 37% of the original value. T2 relaxation refers to the progressive.
Sound Waves and Ultrasound
Presentation transcript:

BIOE 220/RAD 220 REVIEW SESSION 3 February 6, 2011

What We’ll Cover Today Review some issues from HW 2 Review ultrasound Anatomy Review advanced MRI material (depending on time)

Common issues in HW 2 Pay attention to units when computing linear attenuation coefficient If you’re given a value (from the table) in cm^2/g and a density in g/cm^3, multiply the two together to get a cm^-1 LAC LAC depends on energy of x-rays Calculating Hounsfield Units requires looking up the LAC for water at that energy level Lower energy x-rays get absorbed more -> give higher dose CT contrast is C = A – B… values in HU are already normalized In radiographs, objects closer to the source appear larger

Ultrasound Basics In ultrasound, pressure (sound) waves, generally 1- 10MHz, are transmitted into the body using a transducer By measuring the received signal, we can map reflections to depths within the body, based on time of round trip flight Brightness of objects is determined by the amount they reflect, and by how much sound energy is reaching them Sulci (fibrous tissue) and choroid plexus are bright, fluid is dark Axial resolution is determined by length of sound pulse ½ factor introduced because of round trip measurement Lateral resolution is determined by beam width Depends on frequency, geometry, depth

Ultrasound Basics Speed of sound is dependent on the medium through which it is traveling For soft tissue, it is 1540 m/s Much faster for bone, much slower in air Have to wait for all of the transmitted energy to return before we can transmit a new line (data collection rate is limited by depth and speed of sound) Boundaries between different materials cause much larger reflections Reflection is larger when acoustic impedances are less similar % reflected = 100 * (Z 2 – Z 1 ) 2 / (Z 2 + Z 1 ) 2 % transmitted = %reflected Air has very small Z, soft tissue is 1.62, bone is much larger

Ultrasound Reflectors Tissue itself can be thought of as containing many tiny reflectors

Tissues attenuate signal As energy is reflected (which makes it visible in recording) or absorbed, less is available to penetrate deeper Time Gain Control (TGC) - Inverse scaling is used to correct for attenuation by depth, assuming a consistent tissue type If more/less energy has been reflected by a certain depth than expected, that depth will appear darker/brighter than if everything were homogenous

Surface Anatomy

Deep Gray Structures

Ventricular System

Surface Anatomy

Mid-Sagittal Anatomy

Deep Structures

Level of Anterior Limb of the Internal Capsule

Surface Anatomy

Cerebral Vasculature UHM…WOAH

Circle of Willis

Lateral Cerebrum

Mid Sagittal Cerebrum

Inferior Cerebrum

Deep Structures

Right Carotid Angiogram

Vertebrobasilar Angiogram

Internal Carotid Angiogram (Venous Phase)

Advanced MRI Topics Though they aren’t on this week’s HW, we’ve seen more MRI concepts in class in the past couple weeks I’ll review some of them now, with additional focus when there’s relevant homework

Gadolinium Contrast - MRI Adding Gadolinium to the blood drastically reduces T1 (see slides 5-7 of lecture 4 for why)

In Healthy Brain, Blood Brain Barrier Prevents Large Molecules from Entering Brain

Diffusion Weight MRI Gradients

Diffusion Weighting Can Help Visualize Stroke

1D Spaital Localiation in MRI Gradients encode position as frequency, by altering the Larmor frequency Using the Fourier Transform allows us to recover the frequencies in the recording, which in turn tell us the amount of signal at various positions along the gradient direction

CNR is the Important Metric in MRI In the first homework, we ignored noise and optimized pulse sequences based on contrast In reality, noise interferes with our ability to distinguish different tissues, so contrast to noise is much more important Noise in MRI is generally additive, so SNR and CNR will vary together MR noise is zero mean, so recording for longer improves our SNR (by sqrt(sampling time)) Adjusting scan timing to have more magnetization in the transverse plane also improves SNR Measuring larger voxels means that we’re recording more total signal