N 0 primary photons generated N d primary photons detected Determination of the photon mass attenuation coefficients Check on ParentID( ) Energy value.

Slides:



Advertisements
Similar presentations
The application of GEANT4 simulation code to the verification of a brachytherapy calibration procedure F. Foppiano 1, S. Garelli 1, P. Moresco 1, G. Paoli.
Advertisements

The application of GEANT4 simulation code to the verification of a brachytherapy calibration procedure F. Foppiano 1, S. Garelli 1, P. Moresco 1, G. Paoli.
Photon Collimation For The ILC Positron Target Lei Zang The University of Liverpool Cockcroft Institute 24 th March 2007.
1 COMPARISON BETWEEN PLATO ISODOSE DISTRIBUTION OF A 192 IR SOURCE AND THOSE SIMULATED WITH GEANT4 TOOLKIT F. Foppiano 1, S. Agostinelli 1, S. Garelli.
F. Foppiano, M.G. Pia, M. Piergentili Medical Linac IEEE NSS, October 2004, Rome, Italy
The Vin č a Institute of Nuclear Sciences, Belgrade, Serbia * Universita degli studi di Bologna, DIENCA, Italia Radovan D. Ili}, Milan Pe{i}, Radojko Pavlovi}
Use of G EANT 4 in CMS AIHENP’99 Crete, April 1999 Véronique Lefébure CERN EP/CMC.
The best collimator configuration (material, number of collimators, collimator shape) is determined by minimizing the ratio R, where N ae is the number.
GAMOS tutorial Histogram and Scorers Exercises
A general purpose dosimetric system for brachytherapy
Emily Poon Frank Verhaegen March 6, 2006
14 Overview of Geant4 Examples 2 nd Finnish Geant4 Workshop 6-7 June 2005 Dennis Wright (SLAC)
Geant4 in Brachytherapy
Tissue inhomogeneities in Monte Carlo treatment planning for proton therapy L. Beaulieu 1, M. Bazalova 2,3, C. Furstoss 4, F. Verhaegen 2,5 (1) Centre.
14 User Documents and Examples II SLAC Geant4 Tutorial 17 May 2007 Dennis Wright Geant4 V8.3.
1 M.G. Pia et al. The application of GEANT4 simulation code for brachytherapy treatment Maria Grazia Pia INFN Genova, Italy and CERN/IT
The brachytherapy advanced example Susanna Guatelli (CERN/INFN)
Budker Inst. of Physics IHEP Protvino MEPHI Moscow Pittsburg University.
Derek Liu E. Poon, M. Bazalova, B. Reniers, M. Evans
Workshop on Physics on Nuclei at Extremes, Tokyo Institute of Technology, Institute for Nuclear Research and Nuclear Energy Bulgarian Academy.
14 Overview of Geant4 Examples Geant4 Tutorial 8-10 March 2004 Dennis Wright (SLAC)
Gamma calorimeter for R3B: first simulation results INDEX ● The calGamma Geant4 simulation ( a short introduction ) ● Crystal and geometry selection: –
TÍTULO DO TRABALHO NOMES DOS AUTORES ENDEREÇOS E DOS AUTORES INTRODUTION Gammacell 220 Series 39 is a irradiation device purchased by CDTN/CNEN in.
Modelling of Electron Air Showers and Cherenkov Light A.Mishev J. Stamenov Institute for Nuclear Research and Nuclear Energy Bulgarian Academy of Sciences.
Summary of Work Zhang Qiwei INFN - CIAE. Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases.
M.G. Pia et al. Brachytherapy at IST Results from an atypical Comparison Project Stefano Agostinelli 1,2, Franca Foppiano 1, Stefania Garelli 1, Matteo.
Geant4 Collaboration 1 Electromagnetic Physics Authors: P. Gumplinger, M. Maire, P. Nieminen, M.G. Pia, L. Urban Budker Inst. of Physics IHEP Protvino.
S. Guatelli, CPS Innovations, Knoxville, 13 th -21 st January Brachytherapy exercise.
Question and Answer 1) A weighted Monte-Carlo ray trace of particles exiting the target/magnet assembly for all primary beam energies showing: a) Where.
Pedro Arce Introducción a GEANT4 1 GAMOS tutorial Plug-in’s Exercises Pedro Arce Dubois CIEMAT
GAMOS tutorial X-ray Exercises
A General Purpose Brachytherapy Software Simulation + Analysis (isodose calculation) 2/10/2002 Geant4 Workshop CERN Susanna Guatelli Univ. and INFN Genova.
S. Guatelli, M.G Pia, INFN Genova G. Cosmo, S. Guatelli, M.G Pia Salamanca, July 2002
Medical Accelerator F. Foppiano, M.G. Pia, M. Piergentili
Reducing the occupancies in the calorimeter endcaps of the CLIC detector Suzanne van Dam Supervisor: André Sailer CERN, 6 March 2014.
Technological Transfer from HEP to Medical Physics How precise Brachytherapy MonteCarlo simulations can be applied in Clinics Reality Problem: How to achieve.
Calorimeters Chapter 4 Chapter 4 Electromagnetic Showers.
Detector Simulation Presentation # 3 Nafisa Tasneem CHEP,KNU  How to do HEP experiment  What is detector simulation?
Update Chris Rogers, Analysis PC, 13/07/06. State of the “Accelerator” Simulation Field model now fully implemented in revised MICE scheme Sanity checking.
MaGe framework for Monte Carlo simulations MaGe is a Geant4-based Monte Carlo simulation package dedicated to experiments searching for 0 2  decay of.
F. Foppiano, M.G. Pia, M. Piergentili
Validation of EM Part of Geant4
Recent Studies on ILC BDS and MERIT S. Striganov APD meeting, January 24.
Gate-simulation of dose G4: David Nokto & Anette Kniberg.
Notes About MARS background simulations for BTeV A Summary of how far we’ve come and how far we have to go. By DJ Wagner 9/12/98 Vanderbilt University.
1 Neutron Effective Dose calculation behind Concrete Shielding of Charge Particle Accelerators with Energy up to 100 MeV V. E Aleinikov, L. G. Beskrovnaja,
P. Rodrigues, A. Trindade, L.Peralta, J. Varela GEANT4 Medical Applications at LIP GEANT4 Workshop, September – 4 October LIP – Lisbon.
Pedro Arce Introducción a GEANT4 1 GAMOS tutorial RadioTherapy Exercises Pedro Arce Dubois CIEMAT
Validation of the bremssrahlung process IV Workshop on Geant4 physics validation Susanna Guatelli, Luciano Pandola, Maria Grazia Pia, Valentina Zampichelli.
Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases Zhang Qiwei INFN-LNS/CIAE 14th Geant4 Users and Collaboration.
AIDA Workshop, 3/6/2002S. Guatelli Overview of AIDA in Geant4 bio-medical applications A collection of contributions from various user groups AIDA Workshop.
1 Giuseppe G. Daquino 26 th January 2005 SoFTware Development for Experiments Group Physics Department, CERN Background radiation studies using Geant4.
17-19 Oct, 2007Geant4 Japan Oct, 2007Geant4 Japan Oct, 2007Geant4 Japan 2007 Geant4 Collaboration.
A. SarratILC TPC meeting, DESY, 15/02/06 Simulation Of a TPC For T2K Near Detector Using Geant 4 Antony Sarrat CEA Saclay, Dapnia.
ArgonneResult_ ppt1 Comparison of data and simulation of Argonne Beam Test July 10, 2004 Tsunefumi Mizuno
1 Activation by Medium Energy Beams V. Chetvertkova, E. Mustafin, I. Strasik (GSI, B eschleunigerphysik), L. Latysheva, N. Sobolevskiy (INR RAS), U. Ratzinger.
Validation of GEANT4 versus EGSnrc Yann PERROT LPC, CNRS/IN2P3
Simulations in Medical Physics Y. TOUFIQUE*, R.CHERKAOUI EL MOURSLI*, M.KACI**, G.AMOROS**, *Université Mohammed V –Agdal, Faculté des Sciences de Rabat,
SIMULATION OF BACKGROUND REDUCTION TECHNIQUES FOR Ge DBD DETECTORS Héctor Gómez Maluenda. University of Zaragoza. GERDA/Majorana MC Meeting.
E. Mezzenga 1, E. Cagni 1, A. Botti 1, M. Orlandi 1, W.D. Renner 2, M. Iori 1 1. Medical Physics Unit, ASMN-IRCCS of Reggio Emilia, Italy 2. MathResolution.
Monte Carlo methods in spallation experiments Defense of the phD thesis Mitja Majerle “Phasotron” and “Energy Plus Transmutation” setups (schematic drawings)
INTERCOMPARISON P3. Dose distribution of a proton beam
F. Foppiano3, S. Guatelli2, J. Moscicki1, M.G. Pia2 CERN1 INFN Genova2
Neutron and 9Li Background Calculations
Summary of the Compton-PET project
A Brachytherapy Treatment Planning Software Based on Monte Carlo Simulations and Artificial Neural Network Algorithm Amir Moghadam.
The Hadrontherapy Geant4 advanced example
Geant4 at IST Applications in Brachytherapy
GAMOS tutorial Plug-in’s Exercises
The Geant4 Hadrontherapy Advanced Example
Presentation transcript:

N 0 primary photons generated N d primary photons detected Determination of the photon mass attenuation coefficients Check on ParentID( ) Energy value “Vacuum” material (checked) surrounds the experimental set-up Geometrical set-up

E.M processes implemented E.M. Standard G4PhotoElectricEffect G4ComptonScattering G4GammaConversion Low Energy G4LowEnergyRayleigh G4LowEnergyPhotoElectric G4LowEnergyCompton G4LowEnergyGammaConversion Simulation in water, iron, lead with E.M.Standard and LowE extension and comparison with the National Institute for Standard and Technology (NIST) data

Photon mass attenuation coefficient, Water LowEE.M. Standard Differences %

Photon mass attenuation coefficient, Iron LowEE.M. Standard Differences %

Photon mass attenuation coefficient, Lead LowEE.M. Standard Differences % Below 100 KeV zero photons are detected, all the photons have interaction

Determination of the isodose distribution in water around a 192 Ir source 192 Ir Stainless steel capsule and cable Photon (gamma + x ray) spectrum of Iridium is complex: ~ 24 lines in the energy range KeV G4ParticleGun shoots gamma random position inside the iridium core random direction mean energy = 356 KeV Our Primary Generator (simplified monochromatic model) The microSelectron HDR 192 Ir source

192 Ir The source is placed inside a 30 cm water box which is associated with a Sensitive Detector object We wish to determine the energy deposition in water around the source in a longitudinal plane (cylindrical symmetry) The longitudinal plane is portioned in 300 · 300, 1 mm 3, voxels Geometrical set-up Readout Geometry At every interaction, energy deposition is scored and stored in the relevant voxel (in a matrix)

EM Processes implemented G4MultipleScattering gamma G4LowEnergyRayleigh G4LowEnergyPhotoElectric G4LowEnergyCompton G4LowEnergyGammaConversion e- G4LowEnergyIonisation G4LowEnergyBremsstrahlung e+ G4eIonisation G4eBremsstrahlung G4eplusAnnihilation As in the advanced Brachytherapy example, at the end of the RUN an ASCII file is produced for further processing with X,Z energy deposition Output

Isodose distribution in water around a 192 Ir source photons generated ~ 24 hours of simulation The dose deposition is not isotropic due to source geometry auto-absorption, encapsulation and shielding effects At the bottom centre of the source we can see the effect of the stainless steel cable

Comparison with isodoses of the Plato treatment planning system 1 cm Plato uses an analytical method to calculate the dose distribution: Point approximation of the source to compute the dose Anisotropy function F(  ), instead of F(r,  ) as it should be, to account for the shielding effect of the capsule, etc..

Comparison with the isodoses of the Plato treatment planning system Transverse axis Longitudinal axis Good agreement in front of the source Less good agreement behind the source Good agreement The disagreement in the region behind the source is due to the approximation introduced by the anisotropy function in this direction Geant4 yields a more realistic behaviour

Initial results for the Leipzig applicator The Leipzig applicators were designed to give the optimum isodoses and treat to the correct depth This applicator has the shape of a hollow cylinder of tungsten containing the source Geometrical set-up Water box & ROGeometry Iridium source Applicator

Isodose distribution in water for the Leipzig applicator 10 8 photons generated ~ 4 days of CPU time These are the initial results with this kind of applicator good agreement with manufacturer’s data (Nucletron) satisfactory agreement with our measurements (we have just started making measurements and the systematic errors for the response of the detector are not well known yet) Preliminary

Conclusion · Porting on Windows 98+Cygwin+VisualC++ environment · Simple test for the EM processes · Application in the medical field Simulation for isodose distribution and comparison of the result with those of our TPS and measure · Promotion of Geant4 with poster and oral presentation in several medical physics congress (AIFM, ESTRO, AIRO, …) We think that Geant4 is an useful instrument in medical radiation physics Its use out of the HEP community could be advantageous both for users (as we are) and for the code developers Our activities at