Force Sensors.

Slides:



Advertisements
Similar presentations
FORCE MEASUREMENT.
Advertisements

Instrumentation (AMME2700) 1 Instrumentation Dr. Xiaofeng Wu.
Load Cell &DP Cell 2007-CHEM-17.
MECHATRONICS SENSORS.
Measurements Measurement of Pressure Part 2d: Measurement of Pressure 1Process Instrumentation Lecture NotesMay-15.
Lecture 2: Pressure Measurements
1 Sixth Lecture Types of Transducers and Their Applications Instrumentation and Product Testing.
Variable Capacitance Transducers The Capacitance of a two plate capacitor is given by A – Overlapping Area x – Gap width k – Dielectric constant Permitivity.
Measurement Lab 19 Feb 2003 Note: this material may be copyright protected and may only be used for personal use. 0 Force - I Calibration Force Measurement.
FORCE-STRAIN-STRESS measurements.
SIGHT GLASS The sight glass is normally a graduated glass tube mounted on the side of the tank as shown in Fig This method is very simple and gives.
Instrumentation (AMME2700) 1 Instrumentation Dr. Xiaofeng Wu.
Ksjp, 7/01 MEMS Design & Fab Sensors Resistive, Capacitive Strain gauges, piezoresistivity Simple XL, pressure sensor ADXL50 Noise.
Pressure Sensors.
SENSORS AND TRANSDUCERS
Ultrasonic Testing This technique is used for the detection of internal surface (particularly distant surface) defects in sound conducting.
Pressure Measurement Why is it important?. Pressure Measurement Asses the situation –What is the range of pressures to be measured? –Is pressure dynamic.
Lecture 6: Measurements of Inductance, Capacitance, Phase, and Frequency 1.
Differential Transformer
Classification of Instruments :
Lecture on Measurement of Non-Electrical Quantities
EKT314/4 Electronic Instrumentation
Lecture 3: Bridge Circuits
ISAT 303-Lab3-1  Measurement of Condition: Lab #3 (2005):  List of parameters of condition: –Linear distance, angular displacement, vibration, displacement,
Basics of Measurement and Instrumentation
SENSORS MEETING THE NEEDS OF THE DAY  A device which converts energy or information in one form to another  In other words, a device which provides.
Slide # 1 Velocity sensor Specifications for electromagnetic velocity sensor Velocity sensors can utilize the same principles of displacement sensor, and.
Instrumentation (AMME2700) 1 Instrumentation Dr. Xiaofeng Wu.
EKT 451 CHAPTER 5 DC & AC Bridge..
EKT 451/4 SEM 2 Chapter 6 SENSOR & TRANSDUCER SHAIFUL NIZAM MOHYAR
9AEI It is defined as the change of position of a body with respect to a reference It may be Linear motion Rotational motion Displacement.
Biomedical Electrodes, Sensors, and Transducers
OBJECTIVE Without reference, identify at least four out of six principles pertaining to the application of transducers related to patient care.
Lecture 9: Modeling Electromechanical Systems 1.Finish purely electrical systems Modeling in the Laplace domain Loading of cascaded elements 2.Modeling.
Lecture 3: Bridge Circuits
Displacement and Motion Measurement
INTRODUCTION Strain gauge measurement is a point strain measurement method developed in the USA c.a independently by E. Simmons and A. Ruge. It.
BASIC MECHANICAL SENSORS AND SENSOR PRINCIPLES. Definitions Transducer: a device that converts one form of energy into another. Sensor: a device that.
Transducers.
Types Of Transducers Resistive Position Transducer: The principle of the resistive position transducer is that the physical variable under measurement.
ROBOTICS 01PEEQW Basilio Bona DAUIN – Politecnico di Torino.
Pacific school of Engineering Sub: I.P.C Topic: Pressure measurement Guided by Piyush modi Mayani Chintak Sudani Dhrutik Bhikadiya.
Summary of Tactile sensors for robotics applications Student Talk – Di Zhu.
EKT 451 CHAPTER 6 Sensor & Transducers.
1 Transducers EKT 451 CHAPTER 6. 2 Definition of a Transducers   Transducer is any device that converts energy in one form to energy in another.  
TRANSDUCERS PRESENTATION BY: ELECTRICAL ENGINEERING DEPARTMENT.
Electric Pressure Transducer
MECH 373 Instrumentation and Measurements
MECH 373 Instrumentation and Measurements
Measurement And Instrumentations DR. Eng. Samir Elshamy
TRANSDUCERS PRESENTATION BY: Dr.Mohammed Abdulrazzaq
Gujarat Power Engineering & Research Institute
Transducers A transducer is a device that converts energy from one form to another. Ex : (Oscilloscope, since it can be used for several types of measurements,
Accelerometry.
MECH 373 Instrumentation and Measurements
Engineering Measurements
UNIT III Range sensing - Proximity sensing - Touch sensing - Force and Torque sensing. Introduction to Machine vision - Sensing and digitizing - Image.
(2) Bridge Circuits.
MECH 373 Instrumentation and Measurements
Variable Capacitance Transducers
Force, Torque and Tactile Sensors
Measurements 17GN1001 Measurement of FORCE and STRAIN
Measurement of Pressure
Robotics Sensors and Vision
Types of Resistance Strain Gauge
ME 311 Mechanical Measurements Instrumentation II 5/6/03
Prepared by Dr. Mohamed Ahmed Awad
MECH 373 Instrumentation and Measurements
TACTILE SENSORS FOR ROBOTIC APPLICATIONS
TOPIC- Load cell A load cell is a transducer that is used to create an electrical signal whose magnitude is directly proportional to the force being.
Presentation transcript:

Force Sensors

Introduction Sensor is a basic component of transducer. The purpose of a sensor is to respond to some kind of an input physical property and to convert it into an electrical signal which is compatible with electronic circuits. The sensor output signal may be in the form of voltage, current, or charge .  

Sensor Types A. Based on power requirement:     1.  Active: require external power, called excitation signal, for the operation     2.  Passive: directly generate electrical signal in response to the external stimulus   B.  Based on sensor placement:      1.  Contact sensors      2.  Non-contact sensors

Force Sensors The fundamental operating principles of force, acceleration, and torque instrumentation are closely allied to the piezoelectric and strain gage devices used to measure static and dynamic pressures.

Force sensors contd… Piezoelectric sensor produces a voltage when it is "squeezed" by a force that is proportional to the force applied. Difference between these devices and static force detection devices such as strain gages is that the electrical signal generated by the crystal decays rapidly after the application of force. The high impedance electrical signal generated by the piezoelectric crystal is converted to a low impedance signal suitable for such an instrument as a digital storage oscilloscope.

Force sensors Contd... Depending on the application requirements, dynamic force can be measured as either compression, tensile, or torque force. Applications may include the measurement of spring or sliding friction forces, chain tensions, clutch release forces.

Force/Torque Measurement Force and torque measurement finds application in many practical and experimental studies as well as in control applications. Force-motion causality. When measuring force, it can be critical to understand whether force is the input or output to the sensor. Design of a force sensors relies on deflection, so measurement of motion or displacement can be used to measure force, and in this way the two are intimately related.

Design of a Force Sensor Consider a simple sensor that is to be developed to measure a reaction force at the base of a spring, as shown below.

Sensor Mechanisms for Force In the force sensor design given, no specific sensing mechanism was implied. The constraint placed on the stiffness exists for any type of force sensor. It is clear, however, that the force sensor will have to respond to a force and provide an output voltage. This can be done in different ways.

Sensing Mechanisms To measure force, it is usually necessary to design a mechanical structure that determines the stiffness. This structure may itself be a sensing material. Force will induce stress, leading to strain which can be detected, most commonly, by – strain gages (via piezoresistive effect) – some crystals or ceramics (via piezoelectric effect) Force can also be detected using a displacement sensor, such as an LVDT.

Strain-gage Force Sensor Design Let’s consider now the force sensor studied earlier, and consider a design that will use one strain gage on an axially loaded material.

Strain guages Many types of force\torque sensors are based on strain gage measurements. The measurements can be directly related to stress and force and may be used to measure other types of variables including displacement and acceleration

What’s a strain gauge? The electrical resistance of a length of wire varies in direct proportion to the change in any strain applied to it. That’s the principle upon which the strain gauge works. The most accurate way to measure this change in resistance is by using the wheatstone bridge. The majority of strain gauges are foil types, available in a wide choice of shapes and sizes to suit a variety of applications. They consist of a pattern of resistive foil which is mounted on a backing material.

Strain gauge contd.. They operate on the principle that as the foil is subjected to stress, the resistance of the foil changes in a defined way.

Strain gauge Configuration The strain gauge is connected into a wheatstone Bridge circuit with a combination of four active gauges(full bridge),two guages (half bridge) or,less commonly, a single gauge (quarter bridge).

Guage factor A fundamental parameter of the strain guage is its sensitivity to strain, expressed quantitatively as the guage factor (GF). Guage factor is defined as the ratio of fractional change in electrical resistance to the fractional change in length (strain).

Strain guage contd.. The complete wheatstone brigde is excited with a stabilized DC supply. As stress is applied to the bonded strain guage, a resistive change takes place and unbalances the wheatstone bridge which results in signal output with respect to stress value. As the signal value is small the signal conditioning electronics provides amplification to increase the signal.

Ballast circuit Assume a simple signal conditioning circuit, a ballast circuit, will be used to convert resistance change in strain guage to voltage change.

Analysis of Force sensors The ballast circuit output is given by : Under strain the gage resistance change is: Where G is the “gage factor”. The change in the output voltage is :

Sensitivity of Force sensor We can now express the output voltage change in terms of sensitivity as : Where sensitivity is given by :

Applications of force sensors In robotic tactile and manufacturing applications In control systems when motion feedback is employed. In process testing, monitoring and diagnostics applications. In measurement of power transmitted through a rotating device. In controlling complex non-linear mechanical systems.

Capacitive based sensors The capacitance between two parallel plates is given by: where A is the plate area, d the distance between the plates, and e the permittivity of the dielectric medium. A capacitive touch sensor relies on the applied force either changing the distance between the plates or the effective surface area of the capacitor. In such a sensor the two conductive plates of the sensor are separated by a dielectric medium, which is also used as the elastomer to give the sensor its force-to-capacitance characteristics.

Capacitive sensors contd…….. To maximize the change in capacitance as force is applied, it is preferable to use a high permittivity, dielectric in a coaxial capacitor design. In Capacitive based sensors sensor, as the size is reduced to increase the spatial resolution, the sensor’s absolute capacitance will decrease. With the limitations imposed by the sensitivity of the measurement techniques, and the increasing domination of stray capacitance, there is an effective limit on the resolution of a capacitive array.

Capacitive sensors contd…….. The figure shows the cross section of the capacitive touch transducer in which the movement of a one set of the capacitors' plates is used to resolve the displacement and hence applied force. The use of a highly dielectric polymer such as poly vinylidene fluoride maximizes the change capacitance.

Optical Sensors The operating principles of optical-based sensors are well known and fall into two classes: Intrinsic: where the optical phase, intensity, or polarization of transmitted light are modulated without interrupting the optical path Extrinsic: where the physical stimulus interacts with the light external to the primary light path. Touch and tactile optical sensors have been developed using a range of optical technologies: Modulating the intensity of light by moving an obstruction into the light path. Photoelasticity

Modulating the intensity of light by moving an obstruction into the light path. The force sensitivity is determined by a spring or elastomer. To prevent cross-talk from external sources, the sensor can be const-ructed around a deformable tube. In the reflective touch sensor below, the distance between the reflector and the plane of source and the detector is the variable. The intensity of the received light is a function of distance. The U shaped spring was manufactured from spring steel, leading to a compact overall design.

Contd… A reflective sensors can be constructed with source-receiver fibre pairs embedded in an solid elastomer structure. As in the shown figure the fibre is a layer of clear elastomer topped with a reflective silicon rubber layer. The amount of light reflected to the receiver is determined by applied force, that changes the thickness of the clear elastomer.

Applications Much attention is given to tactile sensing in minimally invasive surgery(MIS), keyhole surgery. MIS involves humans in the feedback loop and hence does not cover all needs for performing intelligent robotic manipulation. Combining humanoids with advanced grasping and manipulation capabilities, robots could be used pretty much any place in which it can be cumbersome or dangerous to use humans; as 24-hour household help, for fire-fighting, in deep space missions orfor ABC warfare clean-up.