Cold Neutron Spectroscopy on MACS  Virtues and limitations of INS  Enhancing INS at the NCNR  Description of MACS  Science on MACS  Integration of.

Slides:



Advertisements
Similar presentations
Focusing monochromators/analyzers Asymmetric diffraction geometry of the monochromator Dispersive double crystal monochromator Two wavelength sandwich.
Advertisements

Exploring Quantum Magnetism through Neutron Scattering  What is Quantum Magnetism?  Where do we find it?  Why is it interesting?  Summary & Prospects.
Sub-picosecond Megavolt Electron Diffraction International Symposium on Molecular Spectroscopy June 21, 2006 Fedor Rudakov Department of Chemistry, Brown.
Overview of the ARCS Project Plan: The View at One Year Doug Abernathy ARCS Instrument Scientist ARCS IDT Meeting Lujan Center, LANL September 30, 2002.
IPCMS-GEMME, BP 43, 23 rue du Loess, Strasbourg Cedex 2
ARCS software meeting 3/15/02 Experimental Planning, Visualization, and Analysis for Condensed Matter Physicists Collin Broholm Johns Hopkins University.
Diagnostics for Benchmarking Experiments L. Van Woerkom The Ohio State University University of California, San Diego Center for Energy Research 3rd MEETING.
LCLS Studies of Laser Initiated Dynamics Jorgen Larsson, David Reis, Thomas Tschentscher, and Kelly Gaffney provided LUSI management with preliminary Specifications.
Transmission Electron Microscopy (TEM) By Austin Avery.
III. Analytical Aspects Summary Cheetham & Day, Chapters 2, 3 Chemical Characterization of Solid-State Materials Chemical Composition: Bulk, Surface, …
Polarized Beams Using He-3 at the NCNR Triple-Axis Spectrometers Ross Erwin Tom Gentile Wangchun Chen Sarah McKenney.
Progress on the New High Intensity Cold Neutron Spectrometer, MACS C. Broholm 1,2, T. D. Pike 1,2, P. K. Hundertmark 1,2, P. C. Brand 2, J. W. Lynn 2,
Conceptual Design: MACS is designed to maximize the efficiency for energy resolved surveys of Q-space in the sub-thermal energy range. Two innovations.
Small Angle Neutron Scattering SANS (Neutron scattering) by Samuel Ghebru.
Impurities and finite temperature effects in a one-dimensional spin-1 antiferromagnet Coherent excitations in Y 2 BaNiO 5 Loss of coherence for T>0 Chain-end.
R2D2 fast overview Sept version This document is a short description of the R2D2 test beam line at the JEEPII reactor at IFE, Norway. (Contact: Isabel.
HYSPEC HYSPEC INSTRUMENT DESIGN – OUTLINE  The two “models” considered for HYSPEC – inside & outside (Mark)  A breakdown of the components of the two.
Proposal for a High Intensity Chopper Spectrometer at LANSCE Science requiring high sensitivity neutron spectroscopy Limitations of current instrumentation.
MACS –a New High Intensity Cold Neutron Spectrometer at NIST February 17, 2003Timothy D. Pike1 Developing MACS A Third Generation Cold Neutron Spectrometer.
Incommensurate correlations & mesoscopic spin resonance in YbRh 2 Si 2 * *Supported by U.S. DoE Basic Energy Sciences, Materials Sciences & Engineering.
Understanding typical users for this instrument Graduate studentGraduate student –not an X-ray expert but wants to make a spatially resolved measurement;
X-Ray Diffraction Dr. T. Ramlochan March 2010.
PHYS 430/603 material Laszlo Takacs UMBC Department of Physics
Lars Ehm National Synchrotron Light Source
Structure and dynamics of spin polarons induced by doping a Haldane spin-1 chain Collin Broholm * Johns Hopkins University and NIST Center for Neutron.
Solving Impurity Structures Using Inelastic Neutron Scattering Quantum Magnetism - Pure systems - vacancies - bond impurities Conclusions Collin Broholm*
Choosing the Right Neutron Spectrometer Dan Neumann NIST Center for Neutron Research
Why Diffraction, Why Neutrons? J. A. Dura Neutron Small Angle Scattering and Reflectometry NCNR Summer School on June 26, 2006.
Building MACS  Goals of the MACS project  Funding and time line  Technical overview  Possible IDG contributions  Process for IDG involvement in MACS.
HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.
Introduction to Neutron Scattering Jason T. Haraldsen Advanced Solid State II 2/27/2007.
1 Data Acquisition What choices need to be made?.
Managed by UT-Battelle for the Department of Energy Dynamically Polarized Solid Target for Neutron Scattering Josh Pierce, J.K. Zhao Oak Ridge National.
Finite Temperature Spin Correlations in Quantum Magnets with a Spin Gap Collin Broholm* Johns Hopkins University and NIST Center for Neutron Research *supported.
Polarized Neutrons in ANSTO – From LONGPOL to Pelican, Taipan, Sika, Platypus and Quake Dehong Yu and Shane Kennedy Bragg Institute, ANSTO, Australia.
MACS Concept and Project Status Making best use of CW source MACS-imizing incident flux MACS-imizing detection efficiency From concept to reality Collin.
HYSPEC HYSPEC: A High Performance Polarized Beam Hybrid Spectrometer at the SNS Beamline 14B I.Zaliznyak 1, S. Shapiro 1, L. Passell 1, V. Ghosh 1, W.
The NCNR Spin-Polarized Triple-Axis Spectrometer (SPINS) The SPINS instrument is located at the heart of the cold neutron guide hall of the NIST Center.
The Magnetic phase transition in the frustrated antiferromagnet ZnCr 2 O 4 using SPINS Group B Ilir Zoto Tao Hong Yanmei Lan Nikolaos Daniilidis Sonoko.
Shielding Helium Cold neutron source Shutter Cooled filters Radial Collimators Variable Aperture Focusing monochromator on translation stage Focusing monochromator.
Spin Polarized Inelastic Neutron Scattering NIST Summer School on Neutron Spectroscopy Seung-Hun Lee Peter Gehring Sungil Park Alina Visinoiu Gokhan Caliskan.
Neutron Probes for the Hydrogen Economy David Jacobson, Terry Udovic, and Jack Rush, Muhammad Arif, National Institute of Standards & Technology (NIST)
NCNR and NIST Neutron research and probing matter with cold neutrons OR Neutrons ignored no longer!
Collin Broholm Johns Hopkins University and NIST Center for Neutron Research Quantum Phase Transition in a Quasi-two-dimensional Frustrated Magnet M. A.
MACS –a New High Intensity Cold Neutron Spectrometer at NIST September 24, 2002Collin L. Broholm Timothy D. Pike 1 Scientific Program and Requirements.
Conceptual design and performance of high throughput cold spectrometer : MACS Why MACS Layout and key elements Performance Data collection Scientific program.
Past and Future Insights from Neutron Scattering Collin Broholm * Johns Hopkins University and NIST Center for Neutron Research  Virtues and Limitations.
Neutron Scattering Group February, 2001 A High Performance Instrument for the Single Crystal Spectroscopy at the Pulsed SNS. n What is the spectrometer.
NMI3 meeting, ISIS, September 26-29, 2005 Contents: Overview of new capabilities of the RESTRAX software Numerical optimizations of TAS parameters Virtual.
A New High Intensity Cold Neutron Spectrometer at NIST J. A. Rodriguez 1,3, P. Brand 3, C. Broholm 2,3, J.C. Cook 3, Z. Huang 3, P. Hundertmark 3, J. Lynn.
Magnetized States of Quantum Spin Chains
An electron/positron energy monitor based on synchrotron radiation. I.Meshkov, T. Mamedov, E. Syresin, An electron/positron energy monitor based on synchrotron.
Collin Broholm Johns Hopkins University and NIST Center for Neutron Research Quantum Phase Transition in Quasi-two-dimensional Frustrated Magnet M. A.
Frustrated magnetism in 2D Collin Broholm Johns Hopkins University & NIST  Introduction Two types of antiferromagnets Experimental tools  Frustrated.
Neutron Scattering Group March, 2001 A High Performance Hybrid Spectrometer for the Single Crystal Spectroscopy at the Pulsed SNS  Scientific case and.
HYSPEC IDT HYSPEC: Our Instrument at the Spallation Neutron Source. Outline Spallation Neutron Source (SNS) and the BNL Overview of the SNS instrument.
Structure and dynamics of spin polarons induced by doping a Haldane spin-1 chain Collin Broholm * Johns Hopkins University and NIST Center for Neutron.
HYSPEC IDT Polarized Beam Mode for the Hybrid Spectrometer (HYSPEC) at the Spallation Neutron Source. Outline Polarization analysis and the HYSPEC place.
October, 2001 Hybrid Spectrometer for Single Crystal Studies at the Pulsed SNS: an update. n Principal features of the proposed hybrid spectrometer. n.
One Dimensional Magnetic Systems Strong Fluctuations in Condensed Matter Magnetism in one dimension Pure systems Doped systems Magnetized states Conclusions.
Collin Broholm Johns Hopkins University and NIST Center for Neutron Research Quantum Phase Transition in Quasi-two-dimensional Frustrated Magnet M. A.
Collin Broholm * Johns Hopkins University and NIST Center for Neutron Research Y. Chen LANL M. Kenzelmann JHU & NIST C. P. LandeeClarke University K. Lefmann.
Solving Impurity Structures Using Inelastic Neutron Scattering Quantum Magnetism - Pure systems - vacancies - bond impurities Conclusions Collin Broholm*
© 1997, Angus Rockett Section I Evaporation.
D. S. Darrow Princeton Plasma Physics Laboratory
ESS Freia Scope Setting ESS - Lund - 17/10/2016.
MIRACLES budget: Summary of the 3 configurations
High Level Physics Applications for LCLS Commissioning
X-ray Correlation Spectroscopy Instrument
Scope Setting Meeting MIRACLES
Presentation transcript:

Cold Neutron Spectroscopy on MACS  Virtues and limitations of INS  Enhancing INS at the NCNR  Description of MACS  Science on MACS  Integration of MACS in CHRNS  Summary Collin Broholm Johns Hopkins University and NIST Center for Neutron Research

CHRNS 1/5/05 Neutron Spectroscopy  A central tool in condensed matter physics - Unique information about dynamic correlations - Model independent access to interaction strength - Access microscopic structure of dynamic systems  Limited scope on current instruments - Need cm 3 sized crystals - Need weeks of beam time - Need neutron scattering expert  Increased sensitivity will broaden impact - Comprehensive surveys to test theory - Parametric studies - Smaller samples

CHRNS 1/5/05 Interesting samples come in all sizes Cu 2 (quinox) 2 Cl 4 ZnCr 2 O 4 Cu(C 4 D 4 N 2 )(NO 3 ) 2 Y 2 BaNiO 5 ≈ 40 mm ≈ 10 mm ≈ 4 mm ≈ 0.1 mm Bound spinons in spin-1 chainFree spinons in spin-1/2 chain Frustrated Magnetism Bound spinons in spin-1/2 ladder Need high sensitivity to access physics in small samples

CHRNS 1/5/05  Q and E resolved spectroscopy:  Energy scale J varies more than length scale a Resolution requirements to probe magnets Need range of E resolution at fixed Q resolution

CHRNS 1/5/05 Comparing TOF to TAS Large detector solid angle is possible E-scan without moving parts Can use spallation source peak flux Large detector solid angle is possible E-scan without moving parts Can use spallation source peak flux Can focus neutrons with Bragg optics Freely select range of energy transfer Can use reactor CW flux Can focus neutrons with Bragg optics Freely select range of energy transfer Can use reactor CW flux TAS like TOF like

CHRNS 1/5/05 TOF/TAS complementarity TOF Data from MAPS/ISIS TAS Data from NIST 10% Ca doped Y 2 BaNiO 5 Xu et al science (2000)

CHRNS 1/5/05 Unique Opportunities for INS at the NCNR 10 3  /  0 Brightness through cooling Steradian view of ≈ 250 cm 2 cold source

CHRNS 1/5/05 Characteristics of a TAS at NG0  Wave vector resolution using full beam:  Energy Resolution:  Flux on sample:  Incident Energy Range meV Ideal conditions for probing slowly propagating excitations in hard condensed matter Collin Broholm NIM (1996)

CHRNS 1/5/05 Maximizing the potential for new science  Beam delivery system - Focus full beam onto small sample - High rejection rate for non-E i neutrons - Variable Q and E i resolution  Detection system - Maximize solid angle of detection system - Offer variable resolution - Maximize S/N through shielding and geometry  User interface - Fast, accurate, and safe setup - Data Acquisition Planning Tools - Click for access to all features - Comprehensive visualization and analysis tools

CHRNS 1/5/05 Overview of MACS Shielding Helium Cold Source Shutter Cooled filters Radial Collimators Variable Aperture Focusing monochromator on translation stage Focusing monochromator on translation stage 6.2 m Focusing supermirror Aperture Attenuator Monitor Aperture Attenuator Monitor Sample position 40 channel detection system

CHRNS 1/5/05 MACS beam shutter Four position rotating shutter 1.Closed: 70 mm thick neutron shielding 2.50 mm vertical slit 3.Conical full opening mm vertical slit

CHRNS 1/5/05 Cooled Incident Beam filters Reject non-E i neutrons  E i < 5 meV : 10 cm beryllium  E i <15 meV : 5 cm PG  E i <20 meV : 8 cm Sapphire  Cold filters move in vacuum  Pneumatic actuation in <15 s

CHRNS 1/5/05 The Monochromator Cask Collimators to control E-resolution Doubly focusing monochromator Aperture to control Q-resolution Translation Stage to vary incident energy

CHRNS 1/5/05 Four-position Radial collimator Open 40’ 20’ 60’ Control source size hence   Gd 2 O 3 coated Stainless foils  Two aligned segments: 4 settings  Pneumatic actuation in <15 s

CHRNS 1/5/05 Variable incident beam aperture Control beam envelope hence  Q  Independent control of Q-resolution  Trim beam to match monochromator  Full range actuation in 5 s  10 cm moderating+absorbing shutters B4CB4C High density Polyethylene 10 cm

CHRNS 1/5/05 The MACS monochromator Rotation Stage Translation Stage 10 B:Al shielding 3 × Hollow aluminum posts 357×4 cm 2 PG(002) platelets with adjustable surface normal 357×4 cm 2 PG(002) platelets with adjustable surface normal 45 cm 35 cm

CHRNS 1/5/05 Worlds brightest neutron beam Y. Qiu and Y. Dong (2004)  (10 8 n/cm2/s) ’ 40’ 60’ open IN14

CHRNS 1/5/ Channel MACS detection system Cryo-filters to reduce background Collimators to vary resolution 20 × spectroscopic detectors 20 × double x-tal PG analyzers 20 × double x-tal PG analyzers 20 × diffraction detectors

CHRNS 1/5/05 The Double Crystal Analyzer Unit  Variable energy 2.5 meV<E<15 meV  Vertically focusing “compound lense”  Background suppressing collimator  Motion controlled by a single motor  Patent pending for Tim Pike’s design PG not yet mounted

CHRNS 1/5/05 Multi Analyzer Crystal Spectrometer

CHRNS 1/5/05 Constant energy transfer slice kiki kfkf Q

CHRNS 1/5/05 Assembling slices to probe Q-E volume 2 meV 1 meV 0 meV

CHRNS 1/5/05 Data Acquisition Planning with DAVE  User indicates part of Q-E space to cover - Click and drag graphical input on Q-E space slices  DAVE generates script for optimal settings - Point spacing determined by calculated resolution - With full awareness of limits of motion - Reports actual volume covered  Script is executed by instrument control program  DAVE provides real time images of data

CHRNS 1/5/05  Expand the scope for Inelastic scattering from crystals: —0.5 mm 3 samples —Impurities at the 1% level —Extreme environments: pressure and fields to tune correlated systems —Complete surveys to reveal spin-wave-conduction electron interactions  Probing short range order —Solid ionic conductors, spin glasses, quasi-crystals, ferroelectrics, charge and spin polarons, quantum magnets, frustrated magnets.  Excitations in artificially structured solids —Spin waves in magnetic super-lattices —Magnetic fluctuations in nano-structured materials  Weak broken symmetry phases —Incommensurate charge, lattice, and spin order in correlated electron systems Elements of Scientific Program for MACS Saxena et al. (2000) Schreyer et al (2000) Lee et al. (2002) Matsunada et al. (2002) J. Rodriquez et al (2004)

CHRNS 1/5/05 Funding MACS InstitutionFunds NIST$3.9M NSF-MRI$1.7M JHU$1.3M MACS$6.9M

CHRNS 1/5/05 White Beam Conditioning System (NCNR) Monochromating system (JHU-IDG) Get Lost pipe (NCNR) Monochromatic beam transp. Sample positioning system Detection System Building MACS

CHRNS 1/5/05 Schedule for MACS MilestoneDate Installation of beam line components requiring long shutdownSept First monochromatic beam to sample positionSpring 2005 Instrument ready for commissioning experimentsFall 2005 Instrument ready for general users through CHRNSSummer 2006

CHRNS 1/5/05 Integration of MACS in CHRNS  Broad scientific impact requires CHRNS users - Partial support for 1 senior+2 junior scientists to operate MACS for users - Software development through DAVE - Amplify the MACS educational program through the CHRNS summer school  Partial support of maintenance - Miscellaneous repairs and upgrades - Computer hardware and software  Distribution of beam time - 20% NIST - 20% JHU - 60% CHRNS users

CHRNS 1/5/05 Summary  MACS makes use of unique aspect of the NBSR: large solid angle access to intense cold neutron source  MACS will be a formidable tool to probe nano-scale dynamics in hard condensed matter - Most intense cold neutron beam in the world - Multi-channel low background detection system - seamless access to advanced features through DAVE  Ability to tailor energy range and resolution makes MACS complementary to TOF spectrometers  An active user program through CHRNS is needed to realize the scientific potential of MACS

CHRNS 1/5/05 Contributors to MACS project NIST Center for Neutron Research: G. Baltic, P. C. Brand, C. Brocker, M. English, P. D. Gallagher, C. J. Glinka, P. Kopetka, J. G. LaRock, J. W. Lynn, J. Moyer, N. Maliszewskyj, D. J. Pierce, M. Rowe, J. Rush, and others Johns Hopkins University: R. Barkhouser, C. Broholm, R. Hammond, P. K. Hundertmark, R. Lavender, J. Orndorff, T. D. Pike, G. Scharfstein, S. A. Smee, and others