| © Otto Bock HealthCare Microprocessor Control in Prosthetics & Orthotics. Andreas Kannenberg, MD PhD, Executive Medical Director North America.

Slides:



Advertisements
Similar presentations
Effect of an Unstable Shoe Construction on Lower Extremity Gait Characteristics Nigg, Benno M. Ferber, Reed Gormley Tim Human Performance Laboratory University.
Advertisements

Prosthetic Gait Deviations
Ellen Costello Susan Leach Joyce Maring Elizabeth Ruckert.
Functional Outcomes of Patients Undergoing Anterolateral versus Anteromedial Approaches of the Ankle for Pilon Fractures Tyler J. Jenkins BS, Michael Khazzam.
VARIABLE CADENCE KNEES Overview and Brainstorm of Training Strategies Tony Fitzsimons Peter Spooner-Hart Dr Ian Jennsen.
ASSESSMENT CHAPTER 6. Physical assessment PHYSIOTHERAPY ASSESSMENT session CHAPTER 6 PART
Andreas Kannenberg, MD PhD, Director Medical Affairs
Microprocessor Knee Mechanisms and Advanced Foot/Ankle Systems Gary M. Berke MS, CP, FAAOP Adjunct Clinical Assistant Professor, Department of Orthopaedic.
This article and any supplementary material should be cited as follows: Kannenberg A, Zacharias B, Pröbsting E. Benefits of microprocessor- controlled.
Renee Kitto Port Macquarie Base Hospital
© 2014 American Orthotic & Prosthetic Association All rights reserved.
Walking development in children   Most children walk independently between 11 and 15 months of age.between 11 and 15 months of age   Mature gait pattern.
A Very Quick Update on Research in Amputees. Process  Search of AMED, Medline, EMBASE, Cochrane Central Register of Controlled Trials, Cochrane Database.
Gait Deviations and Prosthetic Knee and Feet Systems
Gait.
● 1.4 million cases of traumatic brain injury (TBI) in the United States annually with 30% having documented gait, coordination, and balance deficits.
Biomechanics of Gait Walking
NATURAL GAIT INDUCING TRANSTIBIAL PROSTHETIC LUCIA MELARA ROBERT SCOTT ALEXIS GARO EML 4551 ETHICS AND DESIGN PROJECT ORGANIZATION FIU DEPARTMENT OF MECHANICAL.
Stance Control Knee Ankle Foot Orthoses (KAFOs)
Determinants of Gait Determinants of Gait.
This article and any supplementary material should be cited as follows: Lemaire ED, Samadi R, Goudreau L, Kofman J. Mechanical and biomechanical analysis.
Transtibial Amputation
OTTO BOCK 3R80 Hydraulic Knee
Lecture 10 Dimitar Stefanov. LOWER-EXTREMITY PROSTHESES socket residual limb (soft tissue and bones) (individually fitted component) Example.
Functional Electrical Stimulation ZAIN SULTAN EE NAEEM HUSSAIN EE
This article and any supplementary material should be cited as follows: Wolf EJ, Everding VQ, Linberg AL, Schnall BL, Czerniecki JM, Gambel JM. Assessment.
Gait development in children. The prerequisite for Gait development Adequate motor control. C.N.S. maturation. Adequate R.O.M. Muscle strength. Appropriate.
POSTECH H uman S ystem D esign Lab oratory Ground reaction forces on stairs: effects of stair inclination and age Alex Stacoff et al. (2005, Switzerland)
COMPARISON OF KINETICS OF RAMP AND STAIR DESCENT Andrew Post, B.Sc. and D.G.E. Robertson, Ph.D., FCSB School of Human Kinetics, University of Ottawa, Ottawa,
Comparison of Loaded and Unloaded Ramp Descent Jordan Thornley, B.Sc. and D. Gordon E. Robertson, Ph.D., FCSB School of Human Kinetics, University of Ottawa,
Examination of balance PTP 565. Quote of the day The greatest crime is not developing your own potential. When you do what you do best, you are helping.
This article and any supplementary material should be cited as follows: Raja B, Neptune RR, Kautz SA. Quantifiable patterns of limb loading and unloading.
Clinical Outcomes Measures for scKAFO
FUNCTIONAL OUTCOMES IN PROSTHETICS
© 2014 American Orthotic & Prosthetic Association All rights reserved.
The MIT Leg Lab: From Robots to Rehab.
THE FUTURE OF TOMORROW TODAY
The Future of Knee Bracing Standards of Care The REHABILITATOR™ System of Knee Bracing.
Active Ankle-Foot Orthotic: Tethered Air Muscle P13001 Project Members: Nathan Couper- Mechanical Engineering Bob Day- Mechanical Engineering Patrick Renahan-
This article and any supplementary material should be cited as follows: Meier MR, Hansen AH, Gard SA, McFadyen AK. Obstacle course: Users’ maneuverability.
Comparison of Patient-Oriented Outcomes Between Wearing No Orthosis, a Conventional Orthosis, & Dynamic Bracing Solutions (DBS) Orthoses Marny Eulberg,
Patient Mobility - Ambulation
Part 1: Assessment for Prosthetic Use & Stump Management.
Author name here for Edited books chapter Assessing Balance and Designing Balance Programs chapter.
Falls in the Elderly Judith Harris, DNP, FNP-BC Deborah Doerfler, Ph.D., PT.
Chapter 42 Lower Extremity Amputation
This article and any supplementary material should be cited as follows: Kahle JT, Highsmith MJ. Transfemoral sockets with vacuum-assisted suspension comparison.
SPINE ORTHOSES Michael Zlowodzki MD University of Minnesota Department of Orthopaedic Surgery.
Prosthetics & Orthotics 단국대학교 일반대학원 물리 · 작업치료전공 강권영.
Upon completion of this lecture student will be able to:  Identify different parts of transfemoral prosthesis.  Differentiate between Quadrilateral.
Running Gait.
Functional Electrical Stimulation (FES) of the Ankle
Lifting Analysis-2 Dr Hafiz Sheraz Arshad.
Date of download: 10/16/2017 Copyright © ASME. All rights reserved.
Date of download: 10/17/2017 Copyright © ASME. All rights reserved.
Transfemoral/Transtibial patient prognosis predictors
Date of download: 10/23/2017 Copyright © ASME. All rights reserved.
The Efficacy of Ankle-Foot Orthoses on Improving the Gait of Children With Diplegic Cerebral Palsy: A Multiple Outcome Analysis  Andrew J. Ries, MS, Tom.
Date of download: 11/2/2017 Copyright © ASME. All rights reserved.
Amputee Mobility Predictor
Normal Gait.
ERGOnomics TECHnologies
The Efficacy of Ankle-Foot Orthoses on Improving the Gait of Children With Diplegic Cerebral Palsy: A Multiple Outcome Analysis  Andrew J. Ries, MS, Tom.
Immediate Effects of a New Microprocessor-Controlled Prosthetic Knee Joint: A Comparative Biomechanical Evaluation  Malte Bellmann, Dipl-Ing, Thomas Schmalz,
Comparative Biomechanical Analysis of Current Microprocessor-Controlled Prosthetic Knee Joints  Malte Bellmann, Dipl-Ing, Thomas Schmalz, PhD, Siegmar.
Evaluation of Function, Performance, and Preference as Transfemoral Amputees Transition From Mechanical to Microprocessor Control of the Prosthetic Knee 
Walking Development in Children
Energy Expenditure and Activity of Transfemoral Amputees Using Mechanical and Microprocessor-Controlled Prosthetic Knees  Kenton R. Kaufman, PhD, PE,
Energy expenditure and gait characteristics of a bilateral amputee walking with C-leg prostheses compared with stubby and conventional articulating prostheses 
Chapter 26: Ambulatory Aids.
Presentation transcript:

| © Otto Bock HealthCare Microprocessor Control in Prosthetics & Orthotics. Andreas Kannenberg, MD PhD, Executive Medical Director North America

| © Otto Bock HealthCare 2 I © Otto Bock HealthCare Disclosure Andreas Kannenberg is a full-time employee of Otto Bock HealthCare LP, a manufacturer of prosthetic and orthotic components.

| © Otto Bock HealthCare Non-microprocessor controlled prosthetic knees 3 Knee flexion during weight bearing NoLimited Unlimited (yielding) Knee mechanism(s)  locked knee,  friction brake knee,  4-bar polycentric knee  polycentric knees with more than 4 axes,  knees with bouncing adapter  fluid control knees (mechanical or microprocessor-controlled) Terrains supported (+) or not supported (-) for negotiation  walking on level ground -no support of stance flexion for -shock absorption -walking on uneven ground -alternate slope and stair descent  walking on level ground,  stance flexion for shock absorption  walking on slightly uneven terrain  alternate descent of shallow slopes (≤5°) -no support of negotiation of heavily uneven terrain -no support of alternate descent of steeper slopes (>5°) -no support of alternate descent of stairs  walking on level ground,  stance flexion for shock absorption  walking on uneven terrain  alternate descent of slopes and stairs Stability*Function Stability ≠ Safety Safety = stability during level walking, + stability during walking on uneven terrains, slopes, stairs + toe clearance + stumble recovery *stability = prevention of knee collapse during level walking K1 / K2K2 / K3K3 / K4

| © Otto Bock HealthCare 4 Sensors to provide input for gait control software  Knee angle (+ velocity)  Ankle moment  Axial load  Knee moment  Shank inclination (+ velocity)  3D linear accelerations MP controlled Prosthetic Knees: examples

| © Otto Bock HealthCare 5 I © Otto Bock HealthCare MPK research (55 English language publications)  24 clinical trials with 290 patients  18 biomechanical studies with 168 patients  5 patient surveys with 368 patients  3 health-economic studies with 146 patients in 3 countries  2 systematic reviews

| © Otto Bock HealthCare 6 Safety of the C-Leg – Summary of systematic review “Five of these seven studies provide consistent, statistically significant findings of improvements in self-reported reduction of stumbles and falls and improved balance. Additional non-statistically significant improvements support the latter findings and include knee stability in conditions resulting in collapse of other knees and improved balance confidence.“ “In total, these seven studies provide a grade “B“ recommendation.“ Highsmith MJ, Kahle JT, Bongiorni DR, Sutton BS, Groer S, Kaufman KR: Safety, energy efficiency, and cost efficacy of the C-leg for transfemoral amputees: A review of the literature. Prosthet Orthot Int 2010, 34 (4):

| © Otto Bock HealthCare 7 Kahle JT, Highsmith MJ, Hubbard SL: Comparison of non-microprocessor knee mechanism versus C-leg on Prosthesis Evaluation Questionnaire, subles, falls, walking tests, stair descents, and preference. JRRD 2008, 45 (1): 1-14 Stumbles and falls on NMPKs vs. MPKs Average number of stumbles in 60 days on non-MP knee7 ± 3 on the MPK3 ± 4 (significant improvement, p=0.006) Average number of falls in 60 days on non-MP knee3 ± 3 on the MPK1 ± 2 (significant improvement, p=0.03)

| © Otto Bock HealthCare 8 non-MPK in the clinic MPK, 3 months later Courtesy of Michael Leach, CPO, Ottobock

| © Otto Bock HealthCare 9 Systematic review of MPK studies in K2 patients Kannenberg A, Zacharias B, Pröbsting E: Benefits of microprocessor prosthetic knees to limited community ambulators: A systematic review. J Rehabil Res Dev 2014; 51 (10):

| © Otto Bock HealthCare Safety outcomes of MPKs in K2 amputees 10 StudyKahle et al. (2008)Hafner et al. (2009)Burnfield et al. (2012) Safety related outcome measures Number of stumbles and falls VAS on number and frequency of stumbles and falls, confidence while walking and frustration with falls Timed up and go test (TUG), Activity-specific Balance Confidence Scale (ABC scale) Results with statistical significance (p<0.05) in favor of the MPK Number of falls decreased 81% from 2.1±1.5 to 0.4±0.7 (p=0.05)*. Stumble frequency decreased 15.8% (p=0.05). Number of falls decreased 80% (p=0.01). Falls frequency decreased 4.5% (p=0.01). TUG decreased 28% from 24.5 s to 17.7 s (p=0.018). Balance (ABC) improved 26% from 60.1 to 75.7 (p=0.001). Results with statistical trend (p<0.10) in favor of the MPK none Confidence while walking improved 12% (p=0.08). Frustration with falls decreased 23.4% (p=0.06). none No statistical difference between MPK and NMPK Number of stumbles Embarrassment with falls Number of stumbles Frequency and number of semicontrolled falls none Results with statistical significance (p<0.05) or trend (p<.10) in favor of the NMPKs none *post-hoc statistical analysis of published raw data using the Wilcoxon signed rank test Kannenberg A, Zacharias B, Pröbsting E: Benefits of microprocessor prosthetic knees to limited community ambulators: A systematic review. J Rehabil Res Dev 2014; 51 (10):

| © Otto Bock HealthCare Performance-based function and mobility outcomes 11 *post-hoc statistical analysis of published raw data using the Wilcoxon signed rank test StudyKahle et al. (2008)Hafner et al. (2009)Theeven et al. (2011)Theeven et al. (2012) Study outcome measures related to function and mobility Walking tests on level and uneven ground, stairs performance (MRPP), MFCL Walking tests on hills and stairs, dual task performance, Amputee Mobility Predictor (AMP) Performance in ADLs (ADAPT test) Daily activity Results of outcome measures of interest with statistical significance (p<.05) in favor of the MPK Fastest possible walking speed on 75m level ground increased 14.4% (p=0.01)*. Walking speed on 38m uneven terrain increased 19.9% (p=0.008)* Stair descent improved 62.8% (p=0.04)*. Stair descent (Stair Assessment index) improved 273% (p=0.008). Hill descent (Hill Assessment Index) improved 38.9% (p=0.008). Downhill walking speed increased 29.4% (p=0.002). Obstacle course walking speed increased 11.3% (p=0.02). Attention walking speed increased 12% (p=0.02) Performance time in standing activities requiring adequate balance (AS1) decreased with C-Leg and C-Leg Compact in the total group (p= and p=0.002), in high MFCL-2 (p=0.01 and p=0.019) and in intermediate MFCL-2 (p=0.004 and p=0.008). Performance time in activities requiring sitting down and standing up (AS2) decreased in intermediate MFCL-2 with C-leg (p=0.016). Performance time in ambulation activities heavily depending on the patient´s prosthesis related skills (AS3) decreased in high MFCL-2 with C-Leg Compact (p=0.023). none

| © Otto Bock HealthCare Summary of outcome measures 12 Total number of outcome measures Significant benefit of MPK No difference between MPK and NMPKs Significant benefit of NMPKs Safety13 6 (46%) +trend in 2 (15%) 5 (39%) 0 Performance- based function and mobility (55%) 22 (43%) 1 (2%) Biomechanical parameters (45%) 22 (55%) 0 Self-reported function and mobility outcomes (23%) 74 (77%) 0 Kannenberg A, Zacharias B, Pröbsting E: Benefits of microprocessor prosthetic knees to limited community ambulators: A systematic review. J Rehabil Res Dev 2014; 51 (10):

| © Otto Bock HealthCare Discussion 13 Based on the walking speed or AMP scores of the patients on their NMPK prosthesis in the reviewed studies, the following statements can be made:  Individuals walking slower than.5 m/s have not yet been studied using MPKs.  Individuals walking between.5 and.75 m/s may benefit from using an MP stance control knee in safety and activities required for community ambulation such as walking slopes, uneven terrain, and stairs.  Individuals walking faster than.75 m/s may benefit from using an MP stance and swing control knee in safety and activities of community AND multidirectional indoor ambulation. Kannenberg A, Zacharias B, Pröbsting E: Benefits of microprocessor prosthetic knees to limited community ambulators: A systematic review. J Rehabil Res Dev 2014; 51 (10):

| © Otto Bock HealthCare Safety and function of MP stance and swing controlled prosthetic knees 14 Safety reduced stumbles and falls reduced indicators for risk of falling improved balance improved confidence Function and mobility improved ability to perform activities of community ambulation improved ability to perform ADLs important to independence improved satisfaction >90% of amputees prefer an MPK +

| © Otto Bock HealthCare Non-MP and MP controlled hydraulic ankles 15

| © Otto Bock HealthCare Hydraulic and MP-controlled ankles 16 + Evidence Safety Increase in minimal toe clearance and reduction of the risk of tripping over an unseen obstacle in below-knee amputees Socket residual limb interface Reduction of soft tissue loading and pressure during walking, especially while walking on slopes, uneven terrain, and stairs Level walking Reduction of braking forces during level walking, reduction of the perception to have to “climb over the foot” at loading response, significant increase in self-selected walking speed in both below- and above-knee amputees Slope and stair ambulation More symmetrical and physiological movement patterns with reduction of compensatory movements and loading of the sound side in below-knee amputees

| © Otto Bock HealthCare 17 I © Otto Bock HealthCare Orthotics SCO Locked KAFO Posterior off-set KAFO C-Brace

| © Otto Bock HealthCare 18 Paresis of Knee Stabilizing Muscles A paresis of the muscles stabilizing the knee may be caused by various diseases or injuries (e.g. polio, post-polio, lumbar disc herniation, injury to the femoral nerve, spinal cord injury, stroke). I © Otto Bock HealthCare

| © Otto Bock HealthCare 19 KAFO technologies Locked KAFO locked (stiff) knee joint during stance and swing Posterior off-set KAFO knee locked during stance due to GRF acting anterior of the knee, free swing Stance Control Orthoses (SCO) locked knee (fully extended or slightly flexed) during stance, free swing All standard KAFO/SCO technologies do not allow for  stance yielding  knee flexion during weight bearing (required for alternate ramp and stair descent) I © Otto Bock HealthCare

| © Otto Bock HealthCare 20 Orthotic technologies Locked KAFOStance Control Orthosis I © Otto Bock HealthCare

| © Otto Bock HealthCare foot part C-Leg® hydraulic unit orthotic knee unit w/ knee angle sensor AFO with carbon fibre strut and integrated ankle moment sensor (intelligent AFO) 21 Orthotronic Walking Device: C-Brace® …allows for stance yielding and knee flexion during weight bearing as known from MP stance controlled prosthetics, allowing for reciprocal ramp and stair descent. I © Otto Bock HealthCare

| © Otto Bock HealthCare 22 Results: Level walking kinematics Stance knee flexion  only relative movement between limb and orthosis with SCO/LKAFO  nearly physiologic knee stance flexion in 4/6 pts. with C-Brace (11° ± 5.6°) Swing knee flexion  SCO: undampened knee flexion higher than normal (74° ± 6.4° compared to 65° [normal]  C-Brace: close to normal (66° ± 8.5°) C-Brace SCO able-bodied subjects Schmalz T, Bellmann M, Pröbsting E, Blumentritt S: A functional comparison of conventional KAFOs and a microprocessor-controlled leg orthosis system based on biomechanical parameters. Prosthet Orthot Int, published online 23 September 2014, DOI: /

| © Otto Bock HealthCare 23 I © Otto Bock HealthCare

| © Otto Bock HealthCare 24 Questionnaires used for the survey Challenge There are no validated outcome measures for KAFO/SCO fitting and use. Therefore, outcome measures had to be developed:  Orthosis Evaluation Questionnaire (OEQ) based on the validated Prosthesis Evaluation Questionnaire (PEQ): 81 questions to be answered on a Visual Analague Scale (VAS), resulting in a total score and 9 sub-scores I © Otto Bock HealthCare

| © Otto Bock HealthCare 25 Orthosis Evaluation Questionnaire (OEQ) p=.02 I © Otto Bock HealthCare 68.9 ± ± 6.7

| © Otto Bock HealthCare I © Otto Bock HealthCare 26 OEQ subdomains with significant benefits of C-Brace® 63.5±20.6 vs. 85.1± ±20.2 vs. 88.5± ±28.1 vs. 81.3± ±33.3 vs. 86.9±23.7 p=.003 p=.02 p=.008

| © Otto Bock HealthCare I © Otto Bock HealthCare 27 OEQ subdomains with insignificant benefits of C-Brace® 71.6±115 vs. 72.6± ±35.1 vs. 80.3± ±20.5 vs. 86.4± ±27.5 vs. 70.4±33.2

| © Otto Bock HealthCare I © Otto Bock HealthCare 28 OEQ subdomains with insignificant benefits of KAFO/SCO 83.4± ±18.1

| © Otto Bock HealthCare 29 Conclusions The differences in technology between standard KAFOs/SCOs and the MP controlled orthotronic walking device result in improved perceived orthotic function and ease of performing many activities of daily living that patients consider important for their everyday lives. These improvements may create a good basis for further improvement of participation in familiy, social, and professional life. I © Otto Bock HealthCare

Thank you for your attention.