The Use of Molecular Beam Spectroscopy to Measure Hyperfine Interactions Sara Fortman, John Nichol, Jimmy Randolph and James Cederberg St. Olaf College.

Slides:



Advertisements
Similar presentations
Investigation of the Use of He-Diatomic Van der Waals Complexes as a Probe of Time Reversal Violation Jacob Stinnett, Dr. Neil Shafer-Ray, and Dr. Eric.
Advertisements

FC-MS from Teledyne Isco CombiFlash ® a Name You Can Rely On.
High Resolution Laser Induced Fluorescence Spectroscopic Study of RuF Timothy C. Steimle, Wilton L. Virgo Tongmei Ma The 60 th International Symposium.
Molecular Bonds Molecular Spectra Molecules and Solids CHAPTER 10 Molecules and Solids Johannes Diderik van der Waals (1837 – 1923) “You little molecule!”
HPLC Coupled with Quadrupole Mass Spectrometry and Forensic Analysis of Cocaine.
3. Capacitance and dielectrics. 3 8 The potential difference between the plates of a 3 μ F capacitor is 100 V. How much energy is stored in.
Mass Spectrometry Introduction:
Cairo University Electrical Engineering – Faculty of Engineering Cyclotrons Yasser Nour El-Din Mohammed Group 2 - Accelerators and Applications Supervisors.
17.1 Mass Spectrometry Learning Objectives:
Mass Spectroscopy Mass Spectrometry ä Most useful tool for molecular structure determination if you can get it into gas phase ä Molecular weight of.
Quantum Computing with Trapped Ion Hyperfine Qubits.
Excitation processes during strong- field ionization and dissociatation of molecules Grad students: Li Fang, Brad Moser Funding : NSF-AMO November 29,
Instrumental Chemistry Chapter 11 Atomic Mass Spectrometry.
Microwave Spectroscopy I
Mass Spectrometry.
Construction of a Laser Frequency Stabilization System for a Magneto Optical Trap Talia Martin and Dr. Edward Deveney Department of Physics, Bridgewater.
K L University 1 By G.SUNITA DEPARTMENT OF PHYSICS.
M.D. Seliverstov February 2013 CERN 1st LA³NET Topical Workshop on Laser Based Particle Sources
Mass Spectrometer Mass spectrometere is a very powerful method to analyse the structure of organic compounds.
DeMille Group Dave DeMille, E. Altuntas, J. Ammon, S.B. Cahn, R. Paolino* Physics Department, Yale University *Physics Department, US Coast Guard Academy.
Electron Paramagnetic Resonance at Hunter College
Electron Spin Resonance Spectroscopy
Anh T. Le and Timothy C. Steimle The electric dipole moment of Iridium monosilicide, IrSi Department of Chemistry and Biochemistry, Arizona State University,
Laboratory for Optical Physics and Engineering MOLECULAR SPECTROSCOPY OF RARE EARTH AND METAL-HALIDE MOLECULES International Symposium on Molecular Spectroscopy.
Effect of Thin Coatings on Surface Plasmon-Enhanced Infrared Spectroscopy using Ni Mesh Microarrays Kenneth R. Rodriguez, Shannon Teeters- Kennedy, Hong.
Mass Spectroscopy 1 Mass Spectroscopy (Mass Spec) Applying Atomic Structure Knowledge to Chemical Analysis.
Atomic Structure HL and SL 2.1 The Atom Atoms were thought to be uniform spheres like snooker balls. Experiments, however, have shown that atoms consist.
FOURIER TRANSFORM MICROWAVE SPECTROSCOPY OF ALKALI METAL HYDROSULFIDES: DETECTION OF KSH P. M. SHERIDAN, M. K. L. BINNS, J. P. YOUNG Department of Chemistry.
The Apparatus…. Ionic target studies…. Neutral target studies…. Queens University Belfast University College London.
MS Intro. MS requires gas-phase ions, why? MS uses magnetic and electric fields to control the path of a compound based on mass to charge ratio (m/z)
In this experiment, C 60 was photoionized with single photons with specified energies between the energy range of 37 to 160eV. The photons used came from.
Simulation of direct space charge in Booster by using MAD program Y.Alexahin, A.Drozhdin, N.Kazarinov.
Mass Analyzers: Quadrupole ion trap?  
63rd Symposium on Molecular Spectroscopy June 18, 2008 Submillimeter Spectroscopy of ZnO (X 1  + ) Lindsay N. Zack Robin L. Pulliam Lucy M. Ziurys Departments.
The Use of Molecular Beam Electric Resonance Technique for High Precision Hyperfine Measurements Charles McEachern, Ben McDonald and Professor James Cederberg.
Secondary Ion Mass Spectrometry A look at SIMS and Surface Analysis.
MC 13.3 Spectroscopy, Pt III 1 Introduction to Mass Spectrometry (cont) Principles of Electron-Impact Mass Spectrometry:  A mass spectrometer produces.
Yan Zhou, Anthony Colombo, David Grimes, Robert Field Cooperative effects in a dense Rydberg gas.
Optical Stark Spectroscopy and Hyperfine study of Gold Chrolride (AuCl) Ruohan Zhang and Timothy C. Steimle International Symposium on Molecular Spectroscopy.
Lecture 33 Rotational spectroscopy: energies. Rotational spectroscopy In this lecture, we will consider the rotational energy levels. In the next lecture,
NUCLEAR MAGNETIC RESONANCE SPECTROSCPY A guide for A level students KNOCKHARDY PUBLISHING.
June 18, nd Symp. on Molec. Spectrosc. Activation of C-H Bonds: Pure Rotational Spectroscopy of HZnCH 3 ( 1 A 1 ) M. A. Flory A. J. Apponi and.
Instrumental Analysis
How do we know? Spectroscopy: Experimental Evidence.
As Unit 1 - Electricity What you need to know..  Current is the rate of flow of charged particles.  In metals these are conduction electrons, most electrons.
Temperature Dependence of Rb + (H 2 O) n and Rb + (H 2 O) n Ar (n=3-5) Cluster Ions Amy L. Nicely OSU International Symposium on Molecular Spectroscopy.
Microwave Transitions Between Pair States Composed of Two Rb Rydberg Atoms Jeonghun Lee Advisor: Tom F. Gallagher Department of Physics, University of.
Equipotential Surfaces A useful way to visualize electric fields is through plots of equipotential surfaces 2-D surfaces where the electric potential is.
Generation of intense few-cycle pulses from the visible to the mid-IR Josh Nelson 1 Danny Todd 2 Adam Summers 3 Derrek Wilson 3 Dr. Carlos Trallero 3 1.
20 Overview current  magnetic field magnetic field  current
The Electromagnetic Spectrum
Rotational spectra of C2D4-H2S, C2D4-D2S, C2D4-HDS and 13CH2CH2-H2S complexes: Molecular symmetry group analysis Mausumi Goswami and E. Arunan Inorganic.
Components of Mass Spectrometer
Acknowledgements Slides and animations were made by Dr. Jon Karty Mass Spectrometry Facility Indiana University, Bloomington.
Starter Complete the quiz and hand in..
Chapter 11 – Analytical Chemistry section
Optical Stark Spectroscopy and Hyperfine study of Gold Sulfide (AuS)
Mass Spectronomer.
Quadropole Mass Analyzer
Electric Potential and Electrical Field
Instrumental Chemistry
Optical Stark Spectroscopy and Hyperfine study of Gold Sulfide (AuS)
New Measurements of the Hyperfine Interactions and Dipole Moment of KI
Mass Spectrometry.
Lecture 22 Introduction to Mass Spectrometry Lecture Problem 7 Due
General Physics (PHY 2140) Lecture 6 Electrostatics
10.6 Fourier Transform Mass Spectrometry
Nat. Rev. Nephrol. doi: /nrneph
Experimental Measurement of the Induced Dipole Moment of an Isolated Molecule in Its Ground and Electronically Excited States. Indole and Indole-H2O.*
Presentation transcript:

The Use of Molecular Beam Spectroscopy to Measure Hyperfine Interactions Sara Fortman, John Nichol, Jimmy Randolph and James Cederberg St. Olaf College June 22, 2006

What we do We use an electric resonance molecular beam spectrometer to study pure hyperfine transitions in diatomic molecules. These transitions are found in the tens of MHz range.

Energy Levels

The Molbeam The molecules travel from the source on the right to the detector on the left.

Source Our source of molecules is a hollow cylinder filled with an alkali-halide salt. We use an effusive oven to vaporize our molecules and send a beam through our spectrometer.

Quadrupole Lens Our quadrupole lenses are made up of four 43 cm electrically charged rods arranged in a diamond. By setting the voltage across the lens,we can focus certain m j states. Molecules in a non-selected state will not be focused by the lens.

Transition Region The transition region contains two long parallel plates. We apply an oscillating RF electric field and an DC field to the plates. We look for second order transitions induced by these fields.

Quadrupole Lens The second quadrupole lens will refocus molecules so that they hit the detector. Molecules that have undergone a transition with a change in the m j state, will not be refocused and will miss the detector.

Detecting Transitions Source Transition Region Detector

For our detector we use a thin strip of tantalum foil to ionize the molecules. A nearby metal blade attracts the positive ions. We can measure the current created by the positive ions.

Raw Data We subtract the RF on value from the RF off value to create a plot like shown above. We can fit these peaks to a Rabi lineshape.

Fitting Data To fit these lines, we use a sum of Rabi lineshapes that take into account the following:  Stark splitting  DC field  RF field  Quadrupole lens voltage

Effect of DC field

Effect of RF field

Effect of Quadrupole Voltage

Fitted Data

Final Calculations After we have observed many transitions and calculated their corresponding frequencies, we imput the data into a program we call spectfit. We then use a singular value decomposition routine to fit for hyperfine coupling constants.

Acknowledgements I would like to thank the St. Olaf College Physics Department, the Whittier endowment, and the American Physical Society for their resources and funding. My colleagues John and Jimmy and my advisor Dr. James Cederberg.