1/13 Tatsuya KUME Mechanical Engineering Center, High Energy Accelerator Research Organization (KEK) ATF2-IN2P3-KEK kick-off meeting (Oct. 9, 2006) Mount.

Slides:



Advertisements
Similar presentations
New Non-Contact, Laser-Based Gauge for Measuring Length and Speed of Gypsum Board Stuart Manser Beta LaserMike.
Advertisements

Passive isolation: Pre-isolation for FF quads A. Gaddi, H. Gerwig, A. Hervé, N. Siegrist, F. Ramos.
ATF2 Interaction Point Beam Size Monitor (Shintake Monitor) Status T. Yamanaka, M. Oroku, Y. Yamaguchi, S. Komamiya ( Univ. of Tokyo ), T. Suehara, Y.
Vibration issues for SuperKEKB M. Masuzawa, R. Sugahara and H. Yamaoka (KEK) Vibration issues for SuperKEKB (IWAA2010)
1/8 T. Kume, Y. Honda, and T. Tauchi High Energy Accelerator Research Organization (KEK) T. Suehara, H. Yoda, M. Oroku, T. Yamanaka and Y. Kamiya The univ.
1 Laser Beam Coherence Purpose: To determine the frequency separation between the axial modes of a He-Ne Laser All sources of light, including lasers,
Wed 15 Jul 2009 ATF2 weekly meeting Oxford MONALISA 1 MONALISA at ATF2 First installation report 15 July 09.
ILC roles Interferometry Results 2009 / 2010 Mon 20 Apr :00 JST (01:00 UTC) MDI TILC09 – Tsukuba OXFORD MONALISA 1.
Final Doublet Stability and in-detector Interferometry MONALISA David Urner Oxford University.
Sta bilization of the F inal F ocus : Stabilization with Nano-Meter Precision.
Wire Position System LCLS Undulator Alignment and Motion Review, Oct. 22, Franz Peters Wire Position System The Undulator.
StaFF: Motion Stabilization with Nano-Meter Precision Proposed experiment conducted within framework of StaFF (Stabilization of Final Focus for ILC). Funded.
Stability of Mechanical Systems S. Sharma and V. Ravindranath.
Status of IPBSM Improvement N. Terunuma, KEK 2012/July/13 ATF2 Weekly Meeting.
ATF2 Status and Plan K. Kubo ATF2, Final Focus Test for LC Achievement of 37 nm beam size (Goal 1) – Demonstration of a compact final focus.
1 ATF2 project: Investigation on the honeycomb table vibrations Benoit BOLZON 33rd ATF2 meeting, 24th January 2007 Laboratories in Annecy working on Vibration.
ATF2 week meeting: Impact of cooling water on the final doublets vibrations Benoît BOLZON Laboratories in Annecy working on Vibration Stabilization 15/10/08.
Vibration measurements on the final doublets and the Shintake Monitor Benoît BOLZON7th ATF2 project meeting, 16/12/08.
Tue 22 Sept 2009 Stabilization Day 7 Oxford MONALISA 1 MONALISA update Could the messenger of bad vibration news be the cause of it? beam pipe Shintake.
1.Beam Tuning Simulation 2.IP Beam Position Stability 2-1 ) Magnet Vibration 2-2 ) IP position jitter subtraction for 2 nd bunch with FONT feedback 2-3.
Concepts for Combining Different Sensors for CLIC Final Focus Stabilisation David Urner Armin Reichold.
Laser interferometer Su-Jin Kim, GNU & Xiaoyu Ding.
Installation of FD in September A.Jeremie, B.Bolzon, N.Geffroy, G.Gaillard, J.P.Baud, F.Peltier With the help of KEK, SLAC, KNU and CERN colleagues For.
IPBSM status and plan ATF project meeting M.Oroku.
ATF2 ILC Final Focus Test Beam Line at KEK-ATF References : ATF2 Proposal, KEK Report ATF2 Proposal Vol.2, KEK Report ホームページ:
IPBSM - Stability of the laser system - Nobuhiro Terunuma Feb. 12 th 2014, KEK, 17 th ATF2 project meeting.
Taikan SUEHARA, 3 rd ATF2 project KEK, 2006/12/18 Status of Shintake-monitor Optics (focused on phase stabilization) Taikan SUEHARA The University.
ATF2 meeting LAPP; David Urner 1 David Urner Paul Coe Matthew Warden Armin Reichold Geoffrey Rayner MPhys alumnus MONALISA Monitoring, Alignment.
Vibration Measurement on the Shintake Monitor and Final Doublet Takashi Yamanaka (Univ. of Tokyo) Benoît Bolzon (LAPP) ATF2 weekly meeting 26 November,
MONALISA an Update David Urner Paul Coe Matthew Warden Armin Reichold Monitoring, Alignment & Stabilisation with high Accuracy.
Modern Optics Lab Lab 6 Part 2: Interference Experiments  Observe interference by plane-parallel plates: Measure the thickness of the plates based on.
CLIC MDI Working Group Vibration attenuation via passive pre- isolation of the FF quads A. Gaddi, H. Gerwig, A. Hervé, N. Siegrist, F. Ramos.
Stabilization of Focus at ATF2 David Urner University of Oxford.
Commissioning Status of Shintake Monitor (IP-BSM) T. Yamanaka, M. Oroku, Y. Yamaguchi, Y. Kamiya, S. Komamiya (Univ. of Tokyo), T. Okugi, N. Terunuma,
Taikan Suehara, 2008/03/05 Shintake monitor in ATF2: status, performance and prospects Taikan Suehara (The Univ. of Tokyo) M.
1/10 Tatsuya KUME Mechanical Engineering Center, High Energy Accelerator Research Organization (KEK) ATF2-IN2P3-KEK kick-off meeting (Oct. 10, 2006) Phase.
CLIC08 workshop CLIC module layout and main requirements G. Riddone, on behalf of the CMWG Home page of the TBM WG:
ATF2 Commissioning Toshiyuki Okugi 2008 / 7 /9 ATF2 beam commissioning meeting, KEK.
Plan in summer shutdown Magnet -SF1FF -Swap of QEA magnet - Multipole field of Final Doublet IP-BSM improvement.
ATF2 background and beam halo study D. Wang(IHEP), S. Bai(IHEP), P. bambade(LAL) February 7, 2013.
NLC - The Next Linear Collider Project Mike Woods May 1999 Vibrations and the NLC IR Welcome to the NanoWorld !
FD support Andrea JEREMIE N.Geffroy, B.Bolzon, G.Gaillard.
T. Suehara, H. Yoda, T. Sanuki, Univ. of Tokyo, T. Kume, Y. Honda, T. Tauchi, High Energy Accelerator Research Organization (KEK) ATF2-IN2P3-KEK kick-off.
How high frequency we care if we need the stabilization of 1nm level?
IP instrumentation configuration for Autumn 2010 ATF2 runs Toshiyuki OKUGI, KEK 2010 / 7/ 1 10 th ATF2 project meeting.
1 ATF2 Project Meeting December 2006 Ground Stabilisation with the CERN STACIS 2000 Stable Active Control Isolation System LAViSta Laboratories in.
Taikan SUEHARA, IN2P3-KEK collaboration meeting on ATF2, Annecy, 2007/10/15 Shintake Monitor: Installation and Commissioning Schedule Taikan SUEHARA, The.
Passive isolation: Pre-isolation for FF quads A. Gaddi, H. Gerwig, A. Hervé, N. Siegrist, F. Ramos.
Superconducting final doublet Support A.Jeremie. SC magnet steps Motivation: have an active stabilisation as planned in ILC and CLIC => need to evaluate.
MONALISA Update David Urner ATF2 Meeting Dec
IPBSM Operation 11th ATF2 Project Meeting Jan. 14, 2011 SLAC National Accelerator Laboratory Menlo Park, California Y. Yamaguchi, M.Oroku, Jacqueline Yan.
Vibrations studies for the nominal optics and the ultra-low beta optics Benoît BOLZON 1 B. Bolzon, A. Jeremie (LAPP) P. Bambade, Y. Renier (LAL) A. Seryi.
Taikan SUEHARA et al., LCWS2007 & DESY, 2007/06/01 R&D Status of ATF2 IP Beam Size Monitor (Shintake Monitor) Taikan SUEHARA, H.Yoda, M.Oroku,
IP diagnostics Toshiyuki Okugi 2008 / 6 /19 ATF2 Software mini-workshop LAL, Orsay.
ATF2: final doublet support Andrea JEREMIE B.Bolzon, N.Geffroy, G.Gaillard, J.P.Baud, F.Peltier With constant interaction with colleagues from KEK, SLAC.
Progress of Shintake Monitor (ATF2 IP-BSM) KEK site meeting 2008/10/31 Takashi Yamanaka.
Design for a New Optical Table of the Shintake Monitor Takashi Yamanaka The University of Tokyo ATF2 weekly meeting 2007/9/26.
Taikan SUEHARA, Joint Meeting of PRPPC in Honolulu, Hawaii, 2006/10/30 Laser Fringe Stabilization of 35nm IP Beam Size Monitor (Shintake monitor) for ATF2/ILC.
Progress of Shintake Monitor (ATF2 IP-BSM) ATF2 weekly meeting 2008/9/3 Takashi Yamanaka The University of Tokyo.
1 A_RD_2A_RD_2 Design of the linear collider machine-detector interface and ATF-2 at KEK Ph.Bambade, J.Brossard, O.Dadoun, C.Rimbault, M.Alabau Pons, A.Jeremie,
Alignment and stability session
Summary FD Support System
Vibration issues at Linear Colliders:
A.Jeremie, B.Bolzon, N.Geffroy, C.Girard, (G.Gaillard)
Topics on Vibration Issues
Laboratories in Annecy working on Vibration Stabilization
ATF2: final doublet support
Background With new accelerators delivering beams always smaller and more energetic, requirements for very precise beam alignment become more and more.
What Environmental Effects Can An Interferometer Detect?
IP configuration session
Presentation transcript:

1/13 Tatsuya KUME Mechanical Engineering Center, High Energy Accelerator Research Organization (KEK) ATF2-IN2P3-KEK kick-off meeting (Oct. 9, 2006) Mount stabilization for Shintake monitor

2/13 Contents About Shintake monitor and results in FFTB Stability expected for Shintake monitor Proposal for mount of Shintake monitor (2 kinds of proposals) –Individual rigid mount –Stabilized common table mount

3/13 Schematics of Shintake Monitor Laser fringe(/Compton) beam size monitor Interference fringes as a reference Electron beam to be measured Scanning electron beam  -ray modulated by interference fringes

4/13 System schematics of Shintake monitor in Final Focus Test Beam (FFTB) Controller Light source (Nd:YAG) Final magnet Girder (with active position control of 0.1Hz, 50nm) Interferometer Gamma ray Gamma detector Electron beam (toward beam dump) Steering magnet Laser table ~20 m of Laser beam transfer line Electron beam (from beam source)

5/13 Results of Shintake monitor in FFTB ( ) Experimentally measure size of the converged electron beam to be 70 nm in radius (  ). Measure beam size with/without active guider control* (*0.1Hz-speed, 50nm-torelance for compensation of position change by temperature drift) cf. N. Ishihara, et.al., “Position control table for FFTB lenses”, XVth International Conference on High Energy Accelerators, July 20-24(1992), Hamburg, Germany Measure beam size without any anti vibration equipments (active control, air suspension table, etc.)

6/13 System performance expected for Shintake monitor in ATF2 project Measure size of electron beam converged to 37 nm of radius (  ) Measures to realize expected performance Use shorter (1064->532 nm) wavelength of laser ->Obtain higher modulation of  -ray for narrower (60->37nm-in design) electron beams Observe and control interference fringes ->Stabilize phase and visibility of interference fringes Analyze structure and mount of interferometer ->Stabilize and improve rigidity for mount and body of interferometer

7/13 Interferometer of Shintake monitor using table (1.6×1.5×0.11 m) to mount optics, total weight of ~740kg Photograph of the interferometer laid for adjustment, The optical table is supported vertical in usage. Photo angle Optical path Optical table is consisted of 5~6 mm-t top and bottom plate made of stainless steel and ~100 mm-t aluminum honeycomb core (AL3/ ) Measurement position (IP)

8/13 Floor vibration of assembly hall for ATF/ATF2 cf. M.Masuzawa, et.al., “Floor tilt and vibration measurements at the ATF,” Second Mini-workshop on Nano Project at ATF, 11 Dec Table. Amplitudes of floor vibration at assembly hall (integrated value of measurements of acceleration meter) Frequency range Amplitude [  m] (Horizontal) Amplitude [  m] (Vertical) >1Hz~1 >5Hz~0.05~0.07 >10Hz~0.01~0.04 Floor condition for vibration seems equal to (~ a little worse? than) FFTB in SLAC

9/13 Stabilize interference fringes and electron beam How stabilize relative position between interference fringes (as a reference) and electron beam (to be measured) for accurate(=low deviation) measurement? Interferometer Final magnet (mount table) Electron beam Floor Coherent Detect and stabilize relative position Active stabilizer Passive stabilizer Interference fringes Stabilizing by phase control

10/13 Problems in case adopting individual mount stabilizers Difficult to know/align relative position between interferometer and magnet How to decide (define) datum (=position references) on both instruments? How to measure distance with sufficient accuracy (~nm?) for distance of ~m in sufficient speed (~Hz?) ? How to align interferometer and magnet in initial alignment? Interferometer Final magnet (mount table) Electron beam Floor Interference fringes

11/13 Proposal1 :Rigid mount on floor Mount both interferometer and magnet rigidly on floor without any stabilizer Interferometer Final magnet (mount table) Electron beam Floor Interference fringes Rigid mount Confirm rigidity of interferometer body Confirm rigidity of mount Estimate effects of magnet originated vibration Advantage Tolerant for slow (coherent: ~0.1Hz?) floor motion Simple & low cost Disadvantage Affected by high-speed (incoherent:1Hz~?) floor motion Affected by distortion of Interferometer body and mounts Affected by magnet (including cooling water, etc.) vibration

12/13 Proposal2: Mount on common stabilized table Mount interferometer and magnet on common stabilized table Interferometer Final magnet (mount table) Electron beam Floor Interference fringes Rigid mount Rigid mount Confirm rigidity of interferometer body Confirm rigidity of mount Common stabilized table Confirm rigidity of table body Estimate effects of magnet originated vibration Advantage Tolerant for both slow (~0.1Hz) and high-speed (1Hz~) floor motion Disadvantage Affected by distortion of Interferometer body, common table, and their mounts Affected (?) by magnet (including cooling water, etc.) vibration High cost -> needs modification of CLIC table

13/13 Subjects to be studied Analysis for rigidity of interferometer body. Mount design and analysis for mount rigidity of interferometer in case 1 (rigid mount) and case 2 (common table mount). Estimation of effects caused by floor motion (vibration) for interferometer body, common table, and their mount rigidities. Estimation of magnet originated (including cooling water, etc.) vibrations and their effects.