Malory J. Faust ∙ Mechanical Option ∙ Senior Thesis 2007.

Slides:



Advertisements
Similar presentations
DOUG BOSWELL MECHANICAL OPTION APRIL 16, 2008 Temple University Tyler School of Art.
Advertisements

Kevin Edstrom Mechanical Option 2011 Senior Thesis April 12 th, 2011 Georgetown University New Science Center Washington, DC.
Chilled Beam Presentation
The Hearst Tower 959 Eighth Avenue New York, NY
STEM Center Delaware County Community College – Media, PA Thesis Final Presentation Dan Saxton Mechanical Option.
Passive Heating and Cooling
The Medical Office Building Brendon Burley Structural Option April 11, 2005 Advisor: Dr. Thomas Boothby.
Energy in Focus Energy Savings with Water Based Systems By Maija Virta Specialist of Indoor Environment Technology.
Jeremiah Ergas AE 482 – 5 th Year Senior Thesis Structural Option April 15 th, 2008 Faculty Consultant: Dr. Ali Memari Northside Piers – Brooklyn, NY Structural.
Jacksonville, FL The Pennsylvania State University Department of Architectural Engineering Zachary Polovchik Mechanical Option Advisor – Dustin Eplee Duval.
WESTINGHOUSE ELECTRIC NUCLEAR ENGINEERING HEADQUARTERS DANIEL AUGHENBAUGH - MECHANICAL OPTION Westinghouse Nuclear Engineering Headquarters Daniel Aughenbaugh.
Coppin State University Physical Education Complex Kaylee Damico – Mechanical Option April 12 th, 2011 Presentation Outline Project Team Project Overview.
Integration of Mechanical System Redesign Geothermal Heat Pump Redesign Wesley S. Lawson Architectural Engineering Mechanical Option Pennsylvania State.
Energy use in buildings Dr. Atila Novoselac Associate Professor Department of Civil, Architectural and Environmental Engineering, ECJ
Building Systems Integration - Energy and Cost Analysis The Milton Hershey School New Supply Center Justin Bem AE Senior Thesis – Spring 2007 Mechanical.
Bowie State University Fine and Performing Arts Center Zachary Lippert Faculty Advisor: Dr. Stephen Treado.
The Edward St. John Student Center Zachary Haupt Faculty Advisor: Dr. William Bahnfleth 11 April 2011.
BEM CLASS 5 Building Thermodynamics – 2 Air-conditioning Load Calculation – latent heat, solar and internal gains.
North Pocono High School
DEA Clandestine Laboratory Training Center Penn State University Architectural Engineering Mechanical Option David M. Potchak.
Energy use in buildings Dr. Atila Novoselac Associate Professor Department of Civil, Architectural and Environmental Engineering, ECJ
CENTRAL HIGH SCHOOL Central High School MID-ATLANTIC REGION ADAM BROWN MECHANICAL OPTION SPRING 2014 Introduction Existing Mechanical System Thesis Proposal.
Presentation Outline Introduction System Optimization Analysis Acoustical Breadth Conclusion Acknowledgements Questions Thesis Final Presentation Army.
National Institutes of Health Building 37 Modernization Katie L. McGimpsey Mechanical Option The Pennsylvania State University Department of Architectural.
Kennedy Krieger Institute Outpatient Medical Center Baltimore, Marylan d Katie Sennett Construction Management Dr. Messner Spring 2008.
Architectural Engineering Mechanical Option Ft. Detrick Defense Medical Logistics Center Building Systems Redesign April 16, 2008 Senior Thesis Presentation.
Ray & Joan Kroc Corps Community Center Mathias Kehoe | Mechanical Option April 09, 2012.
Hilton Hotel at BWI Airport Nathan Patrick The Pennsylvania State University Architectural Engineering – Mechanical Option.
UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA DALE E. HOUCK MECHANICAL OPTION.
VIMS Seawater Research Laboratory Dan DiCriscio AE Senior Thesis Mechanical Option 2007.
Bronx School for Law Government & Justice Yulien Wong Mechanical Option 2006 Senior Thesis Bronx, New York.
Tri-Valley Jr./Sr. High School Hegins, PA Senior Thesis, Spring 2004 Studying The Feasibility of a Dedicated Outdoor Air System.
Architectural Engineering Senior Thesis Mechanical System Redesign Saint Joseph Medical Center Chris Nicolais.
Energy conservation strategies Buildings energy consumption depends on building envelop, efficiency of HVAC and lighting systems, amount of required fresh.
Spring 2007 Senior Thesis Justin D. Schultz Mechanical Option The Hauptman-Woodward Medical Research Institute Dedicated Outdoor Air Applications at the.
APPELL LIFE SCIENCES York College of Pennsylvania Joshua Martz | Dr. Srebric | April 11, 2011 Image Courtesy of RLPS, Ltd.
University of Maryland’s Gossett Field House College Park, MD Jason Borowski Architectural Engineering Mechanical Option Pennsylvania State University.
The Sunshine Elementary School Redesign Proposal Pennsylvania State University AE Senior Thesis Nicholas Scheib Mechanical Option- IP.
Jonathon Gridley Senior Thesis – Spring 2007 Mechanical Option Energy Efficient Mechanical System Alternatives South Jefferson High School S OUTH J EFFERSON.
University of Delaware Center for the Arts Newark, DE Karen Schulte Mechanical Option Spring 2006.
Greenbriar East Elementary School Fairfax, Virginia Michelle L. Siano Mechanical Option Spring 2005 Senior Thesis.
Straumann USA 60 Minuteman Road Andover, MA Kevin Kaufman Mechanical Option The Pennsylvania State University Architectural Engineering.
Building Systems Integration - Energy and Cost Analysis The Milton Hershey School New Supply Center Justin Bem AE Senior Thesis – Spring 2007 Mechanical.
200 Minuteman Drive New Design for Additional Floors and Vibration Sensitive Equipment Brent Ellmann Structural Option Dr. Linda Hanagan - Consultant.
Twin Rivers Elementary/Intermediate of McKeesport Area School District Tessa Bauman Mechanical Option Technical Consultant: Laura Miller 1600 Cornell St.,
Britt Kern Mechanical Option Advisor: Dr. Treado Hunter’s Point South School Queens, New York.
Jesse A. Fisher Mechanical Option Spring 2005 Riverpark Corporate Center, Phase 1 Salt Lake City, Utah.
Hamot Women’s Hospital Erie, PA Michael Galleher Mechanical Option l AE-Senior Thesis l April 12, 2011 l Advisor Dr. Jelena Srebric.
The School District of Philadelphia Administration Headquarters Shell and Core Renovations 440 North Broad Street Philadelphia, PA Jayme Antolik Architectural.
ANTONIO DESANTIS VERNE STRUCTURAL OPTION ADVISOR: PROF. PARFITT APRIL 14, 2008 BRIDGESIDE POINT II PITTSBURGH, PA “BUILDING SYSTEM OPTIMIZATION” THE DEPARTMENT.
Manoa Elementary School Amanda Cronauer Faculty Advisor: Dr. William Bahnfleth 14 April 2010.
Michael Reilly, Jr. – Mechanical Option Advisor – James Freihaut, PhD & Dustin Eplee The Pennsylvania State University Nassau Community College Life Sciences.
ENVIROCENTER PHASE II JESSUP, MD
Eastern High School Baltimore, MD
David Anderson Mechanical Option
Heating, Ventilating, and Air Conditioning
Grunenwald Science and Technology Building
Types of HVAC Technology Used in Business Establishments
Eastern Pennsylvania Laboratory Facility
Acterna Headquarters John M Sekel, EIT Germantown, Maryland
Munters DOAS, Chilled Beams and VRV
Energy Efficiency in District Coiling System
Heating, Ventilating, and Air-Conditioning
Chilled Beam Performance:
Biobehavioral Health Building, University Park, PA
LONGWOOD AT OAKMONT HEALTHCARE CENTER
Senior Thesis Presentation
Frenger “Radiant” chilled beam performance at 1 Shelly St - Sydney
Located at Tufts University in Boston, Massachusitts
RiverView Condominiums II Chicago, IL
Presentation transcript:

Malory J. Faust ∙ Mechanical Option ∙ Senior Thesis 2007

1050 K Street Topics of Discussion Building Introduction Chilled Beam Analysis Solar Shading Analysis Daylighting Analysis Conclusions

1050 K Street Chilled Beam Analysis Solar Shading Analysis Conclusions Building Introduction Daylighting Analysis Project Team Owners: The Lenkin Company The Tower Companies Contractor: The Lenkin Company Architect: Hickok Cole Architects Structural Engineer: Tadjer Cohen Edelson Associates MEP Engineer: Vanderweil Engineers Civil Engineer: Timmons Group Curtain Wall Consultant: CDC

1050 K Street Chilled Beam Analysis Solar Shading Analysis Conclusions Building Introduction Daylighting Analysis Building Site Located on the corner of 11 th & K Streets Streets on the North & West facades Alleys on East & South facades

1050 K Street Chilled Beam Analysis Solar Shading Analysis Conclusions Building Introduction Daylighting Analysis Architectural Background 11 story office building 4 levels below ground for parking Retail on the first level Curtain Wall – North & West facades Green Roof

1050 K Street Chilled Beam Analysis Solar Shading Analysis Conclusions Building Introduction Daylighting Analysis System Summary Energy Recovery Unit (ERU) – 30,000 CFM Enthalpy Wheel – Cooling Coil AHU with cooling on each level VAV System with terminal reheat Chiller Plant – (3) 115 ton rotary screw chillers – (2) Cell, Induced draft open cell cooling tower – Waterside free cooling HX All heating done by enthalpy wheel and electric reheat

1050 K Street Chilled Beam Analysis Solar Shading Analysis Conclusions Building Introduction Daylighting Analysis System Summary Energy Consumption

1050 K Street Chilled Beam Analysis Solar Shading Analysis Conclusions Building Introduction Daylighting Analysis System Summary Initial Cost

1050 K Street Chilled Beam Analysis Solar Shading Analysis Conclusions Building Introduction Daylighting Analysis Alternate Mechanical System Design Goals – Lessen annual energy consumption – Flexible system layouts & capacities – Aesthetically responsive

1050 K Street Chilled Beam Analysis Solar Shading Analysis Conclusions Building Introduction Daylighting Analysis Chilled Beam Background Air Conditioning system providing cooling & heating Uses principles of induction and free convection Can significantly reduce energy costs Aesthetic benefits

1050 K Street Chilled Beam Analysis Solar Shading Analysis Conclusions Building Introduction Daylighting Analysis Chilled Beam Background Active – Integrated with outdoor air supply – Utilizes air flow to induce room air – Can provide heating when requirements are low Passive – Typically used parallel to another system – Do not supply outdoor air – Rely on natural convection for cooling – May be provided in addition to active beams in high cooling spaces

1050 K Street Chilled Beam Analysis Solar Shading Analysis Conclusions Building Introduction Daylighting Analysis Calculation Procedure eQuest – Core & Shell design did not require room by room analysis – Zoning 4 perimeter zones (15’) 1 core zone

1050 K Street Chilled Beam Analysis Solar Shading Analysis Conclusions Building Introduction Daylighting Analysis Calculation Procedure eQuest – Modeled as one large chilled beam per zone – Each beam modeled as a fan coil unit, removing the fan – Utilized “OA-From-System” command to provide ventilation to units – Attached all latent load to ERU dummy zone to decouple the space cooling loads

1050 K Street Chilled Beam Analysis Solar Shading Analysis Conclusions Building Introduction Daylighting Analysis Simulation Results Energy Consumption 10 % reduction in energy consumption Overall savings of KWh/year

1050 K Street Chilled Beam Analysis Solar Shading Analysis Conclusions Building Introduction Daylighting Analysis System Design Summary Chilled Beam Sizing – Used Halton Hit Design Program – Maintained ventilation requirements – Uphold aesthetic appeal of office spaces

1050 K Street Chilled Beam Analysis Solar Shading Analysis Conclusions Building Introduction Daylighting Analysis System Design Summary

1050 K Street Chilled Beam Analysis Solar Shading Analysis Conclusions Building Introduction Daylighting Analysis System Design Summary Chilled Beam Layout – Perimeter zones East & West – (2) rows of 15 South & North – (2) rows of 9 All additional cooling by passive – Internal 11 rows to line up with perimeter active beams

1050 K Street Chilled Beam Analysis Solar Shading Analysis Conclusions Building Introduction Daylighting Analysis System Design Summary Chilled Beam System Cost – Cost of Beams: $200/ LF – 1985 Beams total – 735 MBH Electric Boiler

1050 K Street Chilled Beam Analysis Solar Shading Analysis Conclusions Building Introduction Daylighting Analysis Solar Shading Background Blocks 75% of incoming radiation Absorbs up to 15 % of incoming radiation Prevents 25% of internal heat from escaping in heating conditions Transparent Reduces glare

1050 K Street Chilled Beam Analysis Solar Shading Analysis Conclusions Building Introduction Daylighting Analysis Design Summary Apply shades to 100% of curtain wall North and West facades 8’-9” floor to ceiling height 235 LF of shades (517) 5x8.75 shades

1050 K Street Chilled Beam Analysis Solar Shading Analysis Conclusions Building Introduction Daylighting Analysis Energy Consumption 6% reduction in cooling energy 7% reduction in pump energy Design Summary

1050 K Street Chilled Beam Analysis Solar Shading Analysis Daylighting Analysis Building Introduction Conclusions Daylighting Background Daylight sensors installed in perimeter zones Utilize sunlight when sufficient Decrease lighting energy consumption Sophisticated, dynamic controls Require calibration

1050 K Street Chilled Beam Analysis Solar Shading Analysis Daylighting Analysis Building Introduction Conclusions Design Summary Energy Consumption 25% reduction in lighting energy consumption

1050 K Street Chilled Beam Analysis Solar Shading Analysis Conclusions Building Introduction Daylighting Analysis Conclusions Regardless of energy savings the chilled beam system is not more economical solution than the VAV system due to drastic initial cost differences

1050 K Street Chilled Beam Analysis Solar Shading Analysis Conclusions Building Introduction Daylighting Analysis Thank You All AE Faculty and Staff My classmates, especially Erin & Patrick My family and friends Professionals at Vanderweil Engineers, especially Brandon Harwick and Sam Bohsali

1050 K Street Chilled Beam Analysis Solar Shading Analysis Conclusions Building Introduction Daylighting Analysis Questions