JCM TRAINING OVERVIEW WBA-XX

Slides:



Advertisements
Similar presentations
Robofest 2005 Introduction to Programming RIS 2.0 RCX Code.
Advertisements

DataLogger® Product Training. Index Product Identification Product Set-up Data Logging Procedures Data Analysis Troubleshooting Jump to.
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
JED Microprocessors Pty Ltd Presenting the JED T430 low-cost Projector Controllers Nov 22nd, 2009.
Reprogram the DAGR and Maps Installation
All rights reserved. Copyright © 2008 Argox Information Co., Ltd ISO 9001:2000 F1 Commercial & Light Industry Printer.
Troubleshooting Training Course.  Visual and General Test  Perform System Test (Mode  Perform System Test)  Identify The Error  If you need Technical.
Engineer Training Media Feeder TJ8300 / TJ8500 Media Feeder.
InnoSys Process Sequence. End Effector Components End Effector Prox Switch Load Cell Wire Conduit Crows Foot Nut Runner.
University of Maryland Center for Environmental Science Chesapeake Biological Laboratory IP Phone Training.
 Description of PressurePro System  Identify system components  Display and Operational Modes  Sensor alerts  Checking of tire pressures  Manual.
Unit Test Calibration Training
In this presentation you will:
`SET-UP MANUAL SRM D248 PURPOSE:
4Identifying Leakage Source (Mech/ Elec) 4Mechanical Air Leak- Down 4Mechanical Air Leak- Up 4Electronic Drift- Up/ Down 4Load Cell Operation 4Understanding.
The Handling Camera1 Trainer Training The Handling Camera.
Tool removed during cycle Fault #2 Conditions for setting Tool cocked prox switch goes open during cycle AND force on load cell drops below limit in fault.
KX-NS1000 Initial Set Up For step by step : 16 May,
Syringe Pumps. Topics  Diagrams  Principles of Operation  Applications  Safety  Operation  Preventive Maintenance  Common Failure Modes  Troubleshooting.
KX-NS1000 Version 2 Initial Set Up 1 1.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
Control Panel Overview Key pad: A Qwerty Keypad, used to enter an address. Programmable Features: The programmable features allow you to program.
Training S C A N B O O K Training.
Using the Unity 98 Cordless Response System Directions : Courtesy of IHC public relations.
DataLogger Operation - 1 DataLogger ® Operation Procedures.
Features of CNC Machining Centers
Dr. Hoganson CSIS HC11 Demo Program This is our first lab using the 68HC11 microcontroller. We will “talk” to the microcontroller from a PC, run.
AccuMax Multi-Point Injection Mechanics
The Impulse “Switch” 1Daniel Overman DIS5274/10/2010.
Troubleshooting methods. Module contents  Avaya Wireless tools  Avaya Wireless Client Manager  Avaya Wireless AP Manager  Hardware indicators  Non.
1. 2 LXU800 User’s Manual 1.Installation – Windows XP UI Features Introduction Data Connection & Disconnection.
1.Take holster off phone if applicable 2.Verify antenna is completely inserted 3.To insert antenna slot: 1.Hold antenna button atop phone while inserting.
Paver System Five Control Box Overview Aug 2009 Control Box Overview Paver System Five.
Troubleshooting Hardware Issues Lesson 5. Objectives 2.
Silicon Labs ToolStick Development Platform
ADAM Single Writer User’s Manual ETA Chips Co., Kr, 2011 Rev 1.0.
9000U Quick Guide Marketing & RMA Department XELTEK 8/28/2015.
TRANSMILLE PATs The New Alternative To Fast, Easy & Efficient Portable Appliance Testing.
BASIC Stamp Editor Once installed, the Stamp Editor will be available on your desktop, and as a menu option under Start  Program Files  Parallax Inc.
Available at: – Operate the Tumbler using a Jumper Pin Operate the Tumbler using the jumper pin.
Mercury G3 Service Tool Training Overview
© 2008 Masimo Corporation RAD-57 EMS Carry Case Lightweight: 13 oz. Small: 6.2” x 3.0” x 1.4” Portable: operates on 4 “AA” batteries Supplied with high-visibility,
GCS 300 System Operation Application – Level 1.
Content  1 Component  2 repair instruction  3 How to define problem  4 How to repair  5 How to disassemble  6 PC part  7 Button and Ports.
Mercury G3 Service Tool Training Overview When opening G3 you will start at this screen first import thing to look for is communication.
Front-end Product Training Program –Speed Dome. Table of Contents  Speed dome classification  Speed dome basic information  FAQ  Upgrade.
Basic Input/Output System
JCM TRAINING OVERVIEW DBV-145 Phone # (800) (702) Technical Support # (800) Fax # (702)
3M Touch Systems Mark Roberts Field Application Engineer August 14, 2002 Touchscreen Integration and Troubleshooting.
JCM TRAINING OVERVIEW DBV-200 Phone # (800) (702) Technical Support # (702) Fax # (702)
Chapter 3 Device Monitor Screen Otasuke GP-EX! Chapter 3 Device Monitor Screen Chapter 3 Device Monitor Screen.
JCM TRAINING OVERVIEW DBV-135 Phone # (800) (702) Technical Support # (800) Fax # (702)
Firmware (CLP-310 Series).
InnoSys Park Brake Tool Master Control Panel Screens Revision A, 12Dec /12/20071.
Spring Hill Assembly1 InnoSys Park Brake Tool Master Control Panel Screens 1 3-Mar-2008.
Tool Removed During Cycle Fault #2 Conditions for Setting Tool cocked prox switch goes open during cycle AND force on load cell drops below 5 lbs. Active.
SNG via Webinar. Where’s Webinar??  Double click Aflac 2000 folder  Highlight “SNGWebCommunicator”  Right Click and “Send To - Desktop”
Smart Board Troubleshooting.  The User Guide contains useful information such as installing, connecting, maintaining, and troubleshooting your Smart.
PLC programming Part 3: Problems with solutions. Topics  Every problem is devided into three parts:  Technology description contains the general properties.
All Freezer Advance. When the Freezer is first supplied with power or if a power outage occurs, the display will indicate this by flashing the temperature.
KM SERIES VENDING MACHINES OPERATION MANUAL. ARM Main board & Driver Board DRIVING BOARD MAIN BOARD.
After Construction Name: Per #:.
Fujitsu Training Documentation Hardware Installation
Tool removed during cycle Fault #2
iSERIES PROGRAMMING/LOGGING TRAINING
fischertechnik® RoboPro Software for Gateway To Technology® RoboPro
1. Calibrate all sensors in the machine.
Digital Chart Recorder Operation
The bios.
Presentation transcript:

JCM TRAINING OVERVIEW WBA-XX Phone # (800) 683-7248 (702) 651 0000 Technical Support # (702) 651-3444 Fax # (702) 651-0214 E-mail techsupport@jcm-american.com Web Address http://www.jcm-american.com

Table of Contents Cleaning the Head Calibration Testing Function Testing Head Sensor Test Transport Sensor Test Bill Acceptance Downloading DT-004 DT-104 PC Error Tables Abnormal Codes Test Mode 4 Codes Return Codes Sentry Bezel Part Numbers

CLEANING THE HEAD Perform a preventative maintenance cleaning every 4-6 months Use only soap and water Wipe the lenses, belts, rollers and bill path until clean Use the motor speed test to activate the belts If a lens is altered in any way it must be replaced (scratched, clouded etc) Do not scratch the rollers because they will pick up dirt faster, increasing PM scheduling. If you can see timing marks through the belts, or if they have frayed edges replace the belts If ‘O’ rings are cracked, replace Absolutely NO solvents should be used !!! Do not soak the unit

CALIBRATION MODE Auto calibration mode is entered by turning dip switches 5, 6, 7 and 8, to the “ON” position and powering up the unit. The unit will cycle then stop, waiting to receive the black and white reference paper. Insert the calibration paper black end first. The unit will sample the white paper then the black It will do this 5 or more times and then return the calibration paper. The test LED on power supply or Bezel lamps will blink rapidly if the calibration was successful. If the calibration failed, the test LED/ Bezel lamps, will blink then pause and repeat. The number of blinks between pauses corresponds to an error in the Calibration Error Table. For the WBA use calibration paper part number 501-000032.

CALIBRATION ERROR TABLE Number of LED Blinks Description Possible Cause 1 Entrance lever error Check the PLEV/FLEV sensor 2 Solenoid error Check the solenoid in the transport 3 Feed in sensor error Check the entrance sensor in the transport 4 Transport jamming 5 Gain error (White level adjustment error) If the reference paper was fed in correctly, change the upper sensor board 6 Digital/Analog error 7 Bar sensor error Change the upper sensor board 8 Acceptor head removed Check 20 pin connector that connects head to the CPU board 9 Magnetic setting error 10 Write in error 11 Black level error Change the upper or lower sensor board

TEST MODE Entering Diagnostic Mode WBA does not enter diagnostic mode On the CPU Board set dipswitch 8 “ON” and switches 1 thru 7 “OFF”, apply power The test LED/Bezel light will blink at a steady rate, indicating diagnostic mode WBA does not enter diagnostic mode LED constantly OFF or ON CPU problem – Re-flash the unit (WBA 10/12) or change the EPROM (WBA 11/13)

FUNCTIONAL TEST Dipswitch settings chart for performing functional test on the WBA 8 7 6 5 4 3 2 1 Functional Test E/D   X Transfer motor forward rotation test (test light off = motor speed ok) Transfer motor reverse rotation test (test light off = motor speed ok) Stacker motor and pusher mechanism test Acceptor head/stacker test (Use Error Table #2 only) Acceptor stacker test without the head (Use Error Table #2 only) Solenoid test Acceptor head sensor test (PH06) Transport sensor test (PH07) Bill acceptance test without cash box and frame (Error Table 1 or 3) Bill acceptance test with cash box and frame (Error Table 1 or 3) X = ON E/D = Enable/Disable

HEAD SENSOR TEST (PH06) Entering head sensor test Enter diagnostic mode – dipswitch 8, “ON”, apply power Turn dipswitch 6, “ON” and turn dipswitch 8, “OFF” This activates the head sensor test Dipswitch 6 will be used as the enable/disable switch for these tests Use the test LED/Bezel light to check the status of the sensor being tested, either blocked or un-blocked. The LED will light when the light path of the sensor is interrupted (blocked)

HEAD SENSOR TEST DIPSWITCH SETTINGS Dipswitch settings chart for Validator head sensor test (WBA 10/11/12/13) 8 7 6 5 4 3 2 1 Sensor being tested   E/D X PLEV Not Used PT 1 (IR, Left entrance) PT 2 (IR, Right entrance) HPL (Red, IR - Left Sensor) HPR (Red, IR -Right Sensor) HPC (Red, IR - Center Sensor) X = ON E/D = Enable/Disable

HEAD SENSOR LOCATOR Bill feed in direction Bill feed in direction LOWER UPPER Bill feed in direction

TRANSPORT SENSOR TEST (PH07) Entering Transport Sensor Test Enter diagnostic mode – dipswitch 8, “ON” , apply power Turn dipswitch 7, “ON” and turn dipswitch 8, “OFF” This activates the transport sensor test Dipswitch 7 will be used as the enable/disable switch for these tests Use the test LED/Bezel to check the status of the sensor being tested, either blocked or un-blocked. The LED will light when the light path of the sensor is interrupted (blocked)

TRANSPORT SENSOR TEST DIPSWITCH SETTINGS Transport Sensor test chart - Dipswitch settings 8 7 6 5 4 3 2 1 Sensor being tested   E/D X Entrance Sensor Solenoid Lever Sensor Feed Out Sensor Stacker Home Sensor (S1) Cashbox Sensor (S2) Validator Encoder Sensor Stacker Encoder Sensor Acceptor Head Detached X = ON E/D = Enable/Disable

Transport Sensor Location

Bill Acceptance Test Two ways to run the bill acceptance test Just the head and transport Cashbox sensor (S1) and Stacker home sensor (S1) are disabled and not tested The head and transport insert in a frame with a cashbox All sensors and functions are tested

Bill Acceptance Test Modes Entering Bill Acceptance mode Turn dipswitch 8, “ON” and apply power (diagnostic mode) Turn on dipswitches according to the chart The unit will cycle and is now ready to accept and identify bills. Bill Acceptance test chart - Dipswitch settings 8 7 6 5 4 3 2 1 Bill Acceptance Test Activated E/D   X Bill acceptance without cashbox and frame Bill acceptance test with cashbox and frame X = ON E/D = Enable/Disable

Bill Identification in Bill Acceptance Identification is done by counting the flashes on the LED after a bill is validated. 1 flash = $1 2 flashes = $2 (not programmed) 3 flashes = $5 4 flashes = $10 5 flashes = $20 6 flashes = $50 7 flashes = $100 8 flashes = Bar Code Ticket Switch 1 needs to be turned off after bill acceptance test is started to enable Bar Code ticket reading

Forced Download - Dipswitch settings FORCED DOWN LOAD MODE Select the appropriate download speed (see chart) Connect the WBA per the download tool requirement Power up the WBA For multiple WBA download refer to the Multi-Download Adapter Kit Users Manual Forced Download - Dipswitch settings 8 7 6 5 4 3 2 1 Download Speed Selected X   9,600 Baud - WBA 10 or WBA 12 19,200 Baud - WBA 10 or WBA 12 38,400 Baud - WBA 12 X = ON

DT-004 Downloading Connect the DT-004 to the PS15-006 power supply Or at game use adapter harness (p/n 400-100068 for WBA 10 or p/n 400100069 for WBA 12) Install the appropriate master EPROM chip in the DT-004 The default speed for downloading a single unit is 19200 baud Connect the data harness to the WBA, turn on the DT-004 On the DT-004 the Power light and Ready lights will illuminate The LEDS on the WBA CPU will flash alternately Press Start, the Ready light will start to flash indicating download in progress The OK light will light and the DT-004 will beep when completed To verify, press reset and version If version between the EPROM and the WBA verified, the OK led will light

DT-104 Downloading Connect the data cable to the WBA Insert the proper Master EPROM into the DT-104 socket Power on the DT-104 Scroll the screen to “SETUP” and verify the correct download speed – change if needed Ensure multi-mode is “OFF” Press Menu Button until “Program Menu” is displayed CPU lights on the WBA should be alternating Press “GO” If no error “Device Ready” will be displayed Press ”Start” WBA will show download LED sequence on CPU LEDS The display panel on the DT-104 will count down from the highest memory location “Download Successful” will display on the panel when the download is completed successfully

PC Downloading Connect the PS15-006 power supply with a serial connection to the WBA and connect the 9 pin serial connection to the PC com port. Set the WBA dipswitches for the download speed to be used. Ensure the download program “DWN211.EXE” and the data file are in the same PC directory Enter the following command line from a DOS window <Drive> \ <Folder> \ DWN211.EXE <filename.extension> b 252 246 n, then hit enter Filename.extension = name of the data file to be downloaded b = baud rate (0 = 9600, 1 = 19200, 2 = 38400) 252 = Address (always use 252) 246 = packet size ( this is the largest possible packet size) n = the COM port used (1 or 2) Now press <shift> F to begin download When complete press <shift> V to verify CRC information on the WBA

ERROR TABLE 1 – ABNORMAL CODES Error No. Description Possible Causes Follow-up Test   1 CASHBOX FULL STACKER ENCODER #3 - STACKING, #7 TRANSPORT SENSORS 2 STACKER JAM OR PUSHER UNIT TROUBLE STACKER ENCODER OR PUSHER HOME SENSOR (S1) 3 TRANSPORT COVER OPEN OR SOLENOID LEVER TROUBLE TRANSPORT ENTRANCE SENSOR OR SOLENOID LEVER SENSOR #7 TRANSPORT SENSORS 4 BLOCKED BILL PATH SENSOR ALL HEAD AND TRANSPORT SENSORS #6 - HEAD SENSORS, #7 TRANSPORT SENSORS 5 THE ACCEPTOR HEAD IS DETACHED, NOT CALIBRATED OR INCORRECT TYPE CLEAN AND CALIBRATE. CHECK ALL HEAD SENSORS AND HEAD DETACHED TEST #6 - HEAD SENSORS, #7 - ACCEPTOR HEAD DETACHED 6 TRANSPORT MOTOR TROUBLE OR THE SIGNAL IS NOT SENT FROM THE ENCODER TRANSPORT MOTOR. TRANSPORT ENCODER #1 TRANSPORT MOTOR, #7 VALIDATOR ENCODER SENSOR 8 SOLENOID LEVER TROUBLE LEVER ASSY OR LEVER SENSOR #5 - SOLENOID TEST, #7 SOLENOID LEVER SENSOR 10 CASHBOX NOT FULLY SEATED CASHBOX SENSOR (S2) #7 CASHBOX SENSOR

ERROR TABLE 2 – TEST MODE 4 ONLY ERROR NO DESCRIPTION POSSIBLE CAUSES FOLLOW-UP TEST   2 SOLENOID LEVER TROUBLE SOLENOID SENSOR OR LEVER JAM #5 SOLENOID TEST, #7 SOLENOID LEVER SENSOR 3 BLOCKED HEAD SENSOR CLEAN AND CALIBRATE HEAD SENSORS #6 - ACCEPTOR HEAD SENSORS 4 BLOCKED TRANSPORT SENSOR TRANSPORT SENSORS #7 - TRANSPORT SENSOR TEST 5 CASHBOX FULL STACKER ENCODER #3 STACKER TEST, #7 STACKER ENCODER SENSOR 6 PUSHER UNIT TROUBLE IN THE CASHBOX STACKER ENCODER OR PUSHER HOME SENSOR (S1) #7 STACKER ENCODER, #7 - STACKER HOME SENSOR 7 ACCEPTOR HEAD DETACHED, NOT CALIBRATED OR WRONG TYPE CLEAN AND CALIBRATE. CHECK ALL HEAD SENSORS AND HEAD DETACHED TEST #6 - HEAD SENSORS, #7 ACCEPTOR HEAD DETACHED

ERROR TABLE 3 - RETURN CODES ERROR NO DESCRIPTION POSSIBLE CAUSES FOLLOW-UP TEST 1 CROOKED INSERTION ENTRANCE SENSORS #6 - ENTRANCE SENSORS 2 MAGNETIC PATTERN ERROR CENTER CENTER MAG SENSOR   3 DETECTED A BILL IN THE PATHWAY AT IDLE HPL, HPR ,HPC, OR TRANSPORT ENTRANCE SENSOR #6 - HEAD SENSORS, #7 ENTRANCE 4 DATA AMPLITUDE ERROR ALL IR SENSORS (POSSIBLE POWER SUPPLY) #6 - HEAD SENSORS, #7 TRANSPORT 5 TIMING ERROR, THE BILL DID NOT REACH THE SENSORS WITHIN THE SPECIFIED PERIOD OF TIME HPL, HPR, HPC OR TRANSPORT ENTRANCE SENSOR OR ENCODER SENSOR #6 - HEAD SENSORS, #7 TRANSPORT ENTRANCE SENSOR, VALIDATOR ENCODER 7 ERROR IN PHOTOSENSOR CLEAN AND CALIBRATE #6 - HEAD SENSORS, #7 TRANSPORT SENSORS 8 LEVEL ERROR, THE BILL WAS UNUSUALLY DIRTY OR TWO OVERLAPPING BILLS #6 - HEAD SENSORS 9 RETURN COMMANDED BY DIPSWITCH CHECK DIPSWITCHES 10 RETURN COMMANDED BY THE HOST CHECK MACHINE SETTINGS 11 SOLENOID LEVER TROUBLE SOLENOID LEVER OR SOLENOID SENSOR #5 - SOLENOID TEST, #7 SOLENOID SENSOR 12 THE SENSORS DETECT MOVEMENT IN THE WRONG DIRECTION DURING TRANSFER TO THE CASHBOX HPL, HPR, HPC, OR TRANSPORT ENTRANCE SENSOR #6 - HEAD SENSORS, #7 TRANSPORT ENTRANCE SENSOR 13 THE BILL IS OF A LENGTH OTHER THAN SPECIFIED HPL, HPR #6 - HEAD SENSOR 14 COLOR PATTERN ERROR HPL, HPR, HPC (Red Component) 15 MAGNETIC PATTERN ERROR LEFT OR RIGHT LEFT OR RIGHT MAG SENSOR

Sentry Bezel The Sentry Bezel offers a visual display of validator operations Three indicator panels display information Runway lights Acceptable denominations and last bill inserted Diagnostic Icons for troubleshooting

Normal Operations Runway Lights Denomination lights Flashing in an insertion mode – ready to receive bill Flashing side to side, bill inserted and being validated Denomination lights The denomination panel displays acceptable denominations by illuminating the denomination light in green Un-acceptable denomination lights are not lit The last bill denomination received and validated will be displayed in orange

Performance Indicators Ambulance – BLUE Validator shut down – communication loss or requires immediate attention Key – RED Problem requires cash box access Crossed Circle – RED ROM Verification error or jammed motor – shop repair required Eye – RED Possible cheat attempt If eye lit only – multiple bill rejects in a short period of time

Performance Indicators, cont. Cross Hammer & Wrench – RED Minor service required at the machine JCM Logo – RED Cash box full indicator

WBA PART NUMBERS 550-100042 - PS15-006 Power Supply 400-100040 - WBA 10/11 Extension Cable 400-100110- WBA 12/13 Extension Cable 400-100109 - Adapter Cable WBA 10/11 to WBA 12/13 501-000032 - WBA Calibration Paper TM0100 - WBA Manual 960-000027 - WBA Quick Reference Manual 950-100063 – Sentry Quick Reference Card 960-000014 – Parts Catalog CD