Francesca Bisello, Prague 23-06-2015, IV ARDENT Workshop IV ARDENT Annual Workshop 22-26/06/2015 Prague Francesca Bisello ESR 10.

Slides:



Advertisements
Similar presentations
MOSFET Dosimeters for 50 kVp Electronic Brachytherapy with the Xoft Axxent Source Steve Axelrod, PhD Tom Rusch, PhD Xoft, Inc., Fremont, CA
Advertisements

Design and Experimental Considerations for Multi-stage Laser Driven Particle Accelerator at 1μm Driving Wavelength Y.Y. Lin( 林元堯), A.C. Chiang (蔣安忠), Y.C.
1 Annealing studies of Mimosa19 & radiation hardness studies of Mimosa26 Dennis Doering* 1, Samir Amar-Youcef 1,3,Michael Deveaux 1, Melissa Domachowski.
Quality Control in Diagnostic Radiology
Ionization Chamber Array for External Beam Radiotherapy
IMAGE QUALITY.
RapidArc plan verification using ArcCHECK™
Alexander Klyachko, IU Cyclotron, PTCOG51, Seoul, South Korea, May 17-19, 2012 A.V. Klyachko 1, D.F. Nichiporov 1, L. Coutinho 2, C.-W. Cheng 2, 3, M.
IMAGE QUALITY NOISE LINEARITY CROSS-FIELD UNIFORMITY IMAGE ARTIFACTS.
The TrueBeam System ™ Clinic Name Presenter’s name Clinic location
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
SOIPD Status e prospective for 2012 The SOImager2 is a monolithic pixel sensor produced by OKI in the 0.20 µm Fully Depleted- Silicon On Insulator (FD-SOI)
1 Kimberly Manser Process Development for Double-Sided Fabrication of a Photodiode Process Development of a Double-Sided Photodiode (for application.
Dosepix – a detector for quality assurance in Medical Imaging
A pixel chamber as beam monitor for IMRT S. Belletti 4, A.Boriano 6, F.Bourhaleb 5,7, R. Cirio 6, M. Donetti 5,6, B. Ghedi 4, E. Madon 2, F. Marchetto.
Quality Control Rad T 110.
Derek Liu E. Poon, M. Bazalova, B. Reniers, M. Evans
Results The measured-to-predicted dose ratio criteria used by the RPC to credential institutions is , however for this work, a criteria of
Michele Togno ARDENT ESR 11 – 2D Ionization Chambers Array for Clinical Applications Michele Togno – ARDENT midterm review preparatory meeting, CERNJune,
Erik Fröjdh CERN, Mid Sweden University. Characterization of hybrid pixel detectors Applications for dosimetry in mixed radiation fields.
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 19.03: Optimization of protection in Mammography.
The 6th International Workshop on Radiation Imaging Detectors, July 2004, Glasgow Digital X-ray portable scanner based on monolithic semi-insulating.
In vivo dosimetry Eirik Malinen Eva Stabell Bergstrand Dag Rune Olsen.
Applications of a Pixellated Detection System to Digital Mammography
11 th RD50 Workshop, CERN Nov Results with thin and standard p-type detectors after heavy neutron irradiation G. Casse.
Online Radiation Dose Measurement System for ATLAS experiment I. Mandić a, representing ATLAS collaboration a Jožef Stefan Institute, Jamova 39, Ljubljana,
M. Silari - The ARDENT ITN project 1CNAO, Pavia, 19 October 2012 ARDENT February 2012 – January 2016 Advanced Radiation Dosimetry European Network Training.
Protect, Enhance, and Save Lives III ARDENT Annual Workshop 29/09-02/10/2014 IBA Dosimetry Francesca Bisello ESR 10.
M. Silari - The ARDENT ITN project 1EURADOS, Vienna, 7-10 February 2012 ARDENT February 2012 – January 2016 Advanced Radiation Dosimetry European Network.
S. Mattiazzo 1,2, M. Battaglia 3,4, D. Bisello 1,2, D. Contarato 4, P. Denes 4, P. Giubilato 1,2,4, D. Pantano 1,2, N. Pozzobon 1,2, M. Tessaro 2, J. Wyss.
Application of a 2-D ionization chamber array for dose verification of dynamic IMRT with a micro-MLC Fujio ARAKI, PhD 1, S. TAJIRI 2, H. TOMINAGA 2, K.
Institute for Advanced Radiation Oncology
Imaging and spectroscopic performance studies of pixellated CdTe Timepix detector Dima Maneuski Vytautas Astromskas, Erik Fröjdh, Christer Fröjdh, Eva.
Factors affecting CT image RAD
Munich-Centre for Advanced Photonics A pixel detector system for laser-accelerated ion detection Sabine Reinhardt Fakultät für Physik, Ludwig-Maximilians-Universität.
ARDENT Advanced Radiation Dosimetry European Network Training initiative WP1: Gas Detectors S. Rollet.
Araki F. Ikegami T. and Ishidoya T.
Historical Review and Modalities in Diagnostics
Passive detectors (nuclear track detectors) – part 2: Applications for neutrons This research project has been supported by the Marie Curie Initial Training.
ERIK FRÖJDH – ESR 2 Mid Sweden University, CERN 14th October 20132nd ARDENT Workshop1.
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Geant4 User Workshop, Catania, Italy, 15th October, 2009
Somvilai Mayurasakorn, MD. Division of Therapeutic Radiology and Oncology, Faculty of Medicine, Chiang Mai University Somvilai Mayurasakorn, MD. Division.
The development of the readout ASIC for the pair-monitor with SOI technology ~irradiation test~ Yutaro Sato Tohoku Univ. 29 th Mar  Introduction.
Part No...., Module No....Lesson No
Activities within the ARDENT- project: November 2012 – June 2013 Benedikt Bergmann Institute of Experimental and Applied Physics, Czech Technical University.
A silicon microdosimeter for radiation quality assessment (1) INFN, Sezione di Milano, via Celoria 16, Milano, Italy. (2) Politecnico di Milano,
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 19.04: Optimization of protection in Mammography.
ICT 1 SINTEF Edge-On Sensor with Active Edge Fabricated by 3D-Technology T. E. Hansen 1), N. Ahmed 1), A. Ferber 2) 1) SINTEF MiNaLab 2) SINTEF Optical.
A New Inner-Layer Silicon Micro- Strip Detector for D0 Alice Bean for the D0 Collaboration University of Kansas CIPANP Puerto Rico.
Based on a paper which will appear on Med. Phys. Issue of Dec. 05 Introduction Contrast cancellation algorithm Experimental setup Experimental images:
DESCRIPTION OF PIXIRAD  The PIXIRAD Imaging Counter is an INFN-Pisa Spin-off  It works in photon counting  Pulse discrimination with two thresholds.
Basis of Mammography F. Milano Dept. Clinical Physiopathology University of Florence
Equalization of Medipix2 imaging detector energy thresholds using measurement of polychromatic X-ray beam attenuation Josef Uher a,b, Jan Jakubek c a CSIRO.
V.Aulchenko 1,2, L.Shekhtman 1,2, B.Tolochko 3,2, V.Zhulanov 1,2 Budker Institute of Nuclear Physics, , Novosibirsk, Russia Novosibirsk State University,
Protect, Enhance, and Save Lives Characterization of a new Photon counting Detector with XRF (X-ray fluorecense) Francesca Bisello, IBA-Dosimetry.
MCS overview in radiation therapy
Adapting A Clinical Medical Accelerator For Primary Standard Dosimetry
CONFIDENTIAL MATERIAL Michele Togno - II Annual ARDENT Meeting, Milan – October, 14 th D Ionization Chambers Array for Clinical Applications.
Study of the Radiation Damage of Hamamatsu Silicon Photo Multipliers Wander Baldini Istituto Nazionale di Fisica Nucleare and Universita’ degli Studi di.
IEAP – CTU Prague Measurement of neutron flux during irradiation in NPI Řež T. Slavíček, V. Linhart, S. Pospíšil Institute of Experimental and Applied.
0 Ion Beam Facilities at KOMAC Chan Young Lee on behalf of KOMAC Chan Young Lee on behalf of KOMAC ICABU2014, November 12~14,
Semiconductor Detectors and Applications on X-ray imaging Natalie Diekmann Particle Physics 1 NIKHEF.
Francesca Bisello Dosepix Midterm Review Preparatory Meeting ARDENT Project June 13th, CERN.
6:th IWORID, Glasgow, Scotland, July 2004 Energy Dependence in Dental Imaging with Medipix 2 Börje Norlin & Christer Fröjdh Mid Sweden University.
M. C. Veale1, S. J. Bell1,2, D. D. Duarte1,2, M. J. French1, M
The Silicon Drift Detector of the ALICE Experiment
一种基于晶体间光分享原理的深度测量PET探测器
Effects of tube voltage, filtration, and dose rate on the color difference of the indicator. Effects of tube voltage, filtration, and dose rate on the.
Presentation transcript:

Francesca Bisello, Prague , IV ARDENT Workshop IV ARDENT Annual Workshop 22-26/06/2015 Prague Francesca Bisello ESR 10

Francesca Bisello, Prague , IV ARDENT Workshop Outline: -Research Activities -Dosepix detector -1D monolithic silicon array -Trainings, Conferences, Outreach -Future Activities -Conclusions

Research Activity: Semiconductor detectors in clinical QA in radiotherapy and diagnostics Francesca Bisello, Prague , IV ARDENT Workshop

Dosepix: QA in Diagnostics- kVpmeter Francesca Bisello, Prague , IV ARDENT Workshop Non invasive kVp-meter: closely spaced photodiodes filtered by different thickness and materials : time consuming calibration curves Detector : Performed studies: 1. Chip Characterization 2. kVp-meter in Mammography (22-35 kV) by the analysis of the impinging spectrum -Single photon counting detector -16 x 16 pixels -Pixels size: 220x220 μm, 55x55 μm -Sensor material : 300 μm silicon -Time-over-Threshold -Programmable front end settings -16 Digital Thresholds /pixel

Dosepix: QA in Diagnostics- kVpmeter Francesca Bisello, Prague , IV ARDENT Workshop Detector characterization I mm Cu additional filtration to prevent spectra distortion due to analog pile up Tube setting: 30 kV, 20 mAs Mo-Mo Big Pixels

Dosepix: QA in Diagnostics- kVpmeter Francesca Bisello, Prague , IV ARDENT Workshop Detector characterization II -Source of instability for temperature fluctuation: PLL circuit

Dosepix: QA in Diagnostics- kVpmeter Francesca Bisello, Prague , IV ARDENT Workshop Detector characterization III Radiation Tolerance studies -Radiation tolerance of the assembly -kVp-meter in radiology based on calibration curves (50 Gy /calibration curve) -Stability of Spectrum (Binning Mode) -Irradiation: 40kV photons, X-Ray tube, W-anode -200 Gy, 50Gy/step, 3 days annealing Mean Quantile Position 60keV photopeak

Dosepix: QA in Diagnostics- kVpmeter Francesca Bisello, Prague , IV ARDENT Workshop Detector characterization Radiation Tolerance studies 50 Gy 100 Gy 150 Gy

Dosepix: QA in Diagnostics- kVpmeter Francesca Bisello, Prague , IV ARDENT Workshop Detector characterization Radiation Tolerance studies Conclusion -Additional filtration reduce influence of analog pile up ( mm Cu) -Source of instability vs external temperature: PLL circuit Radiation tolerance studies: -Higher cumulated dose to stabilize the electronics -Deviation within 2%: regulation limit -Re-calibration recovers damages due by radiation -Tests on going: One chip: 5kGy cumulated dose, 1 months annealing

Dosepix: QA in Diagnostics- kVpmeter Francesca Bisello, Prague , IV ARDENT Workshop kVpmeter Algorithm Reference detector: -MagicMax Universal, IBA Dosimetry GmbH, Schwarzenbruck (DE) Method: -Find the quantile who minimizes the difference with reference detector Operation Voltage 22 – 35 kV Current·s20 mAs Inherent Filtration 0.3mm Mo Dose mGy Dose Rate mGy/s Additional filtration 0.1 mm Cu

Dosepix: QA in Diagnostics- kVpmeter Francesca Bisello, Prague , IV ARDENT Workshop kVpmeter Algorithm Conclusions: -Experimental method for kVp reconstruction in mammography within regulation -Long term stability on going

1D Silicon Array: QA in Radiotherapy Francesca Bisello, Prague , IV ARDENT Workshop Needs in Radiotherapy: High spatial resolution Large sensitive area Radiation Tolerance Low sensitivity changes with dose-rate ( dose per pulse) Detector : Facilities: IBA Dosimetry, ICC Doselab, schwarzenbruck, Germany Azienda Ospedaliera Universitaria Careggi, Florence, Italy Perelman Center for Advanced Medicine, Philadelphia, PA, USA True Beam and Clinac iX, Varian Medical System, Palo Alto, CA Pennsylvania Hospital, Philadelphia, PA, USA CyberKnife G4 Accuray Inc., Sunnyvale, CA -Epitaxial monolithic Silicon diodes -1mm pitch -24 cm length -sensitivity changes with dose (0.2%/kGy) -dose per pulse changes (±1% in the range 0.1–2.3 mGy/pulse)

1D Silicon Array: QA in Radiotherapy Francesca Bisello, Prague , IV ARDENT Workshop 1. IMRT and SBRT Patient Plan Verification: 6 clinical cases Comparison with TPS, film and diode array SBRT, 6MV, clinical site: Liver, SDD : 99.3 cm 1D Array—Film (%)2D diode array—Film (%)

1D Silicon Array: QA in Radiotherapy Francesca Bisello, Prague , IV ARDENT Workshop 2. Machine Quality Assurance Commissioning of an Iris Collimator for robotic radiosurgery: physical properties -6 degree freedom -Collimator 5 to 60 mm -Constant tumor tracking - Used in clinics : fields > 10 mm

1D Silicon Array: QA in Radiotherapy Francesca Bisello, Prague , IV ARDENT Workshop Commissioning routine for small photon field Iris collimator beam profiles: -1D array -Scanning diode

1D Silicon Array: QA in Radiotherapy Francesca Bisello, Prague , IV ARDENT Workshop Characterization of Iris collimator Circularityσ (mean radius) 1D Array0.61% (0.18 mm) Echner et al.0.8% (0.25mm) G.Echner et al. Phy.Med. Biol. 54 (2009) Transmission 1D Array0.09% Echner et al.0.05%

1D Silicon Array: QA in Radiotherapy Francesca Bisello, Prague , IV ARDENT Workshop Conclusions -Good performance in dose plan verification of conformational radiotherapy compared with commercial solution -The characterization of Iris collimator provide goods results compared with radiographic films. -Poster Presentation, 57 th AAPM Annual Meeting, Anaheim, CA “ Characterization of a novel high resolution 1D Silicon monolithic array for small field commissioning and quality assurance”

Francesca Bisello, Prague , IV ARDENT Workshop B&A Training : ST Microlectronics January B&A topics ( see Michele´s presentation) -Technical topics: -Steps involved in the wafer processing (Photolithography, Ion Implantation, Wet etching…) -Visit at production lines

Francesca Bisello, Prague , IV ARDENT Workshop Conferences 57 th AAPM annual meeting, July 12-16, Anaheim, CA - AAPM DIAGNOSTIC PHYSICS REVIEW COURSE - Small photon field Dosimetry Outreach - Presentation for high school students part of Educational guidance activities “Physiscs in Medicine: Research and Application”, January 8, 2015

Francesca Bisello, Prague , IV ARDENT Workshop Conclusions -Dosepix detector has been characterized in the mammography flux and energies -An experimental method for the kVp reconstruction has been established -Planned activity: simulation of analog pile up in the chip front end -1D monolithic silicon array has been characterized as machine and quality assurance tool -Good agreement with commercial and reference detectors -Next Acitivities: PhD Thesis

Francesca Bisello, Prague , IV ARDENT Workshop Thank you for your attention

Backup

Dosepix: QA in Diagnostics- kVpmeter Francesca Bisello, Prague , IV ARDENT Workshop Detector characterization Radiation Tolerance studies