Ductwork Systems and Supply Arch 432. What You Need To Know Become familiar with the materials sizing ductwork Understand sizing units.

Slides:



Advertisements
Similar presentations
Formulas.
Advertisements

COOLING AIR © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
BUILDING AIR CONDITIONING
Heating, Ventilating, and Air-Conditioning
Five star hotel in Nablus
Heating, Ventilating, and Air-Conditioning
TYPES OF MECHANICAL SYSTEMS
Heating, Ventilating, and Air-Conditioning (HVAC)
Key HVAC Design Concepts. Agenda Discuss relevance of thermal enclosure system to HVAC system. Present the three major steps to design an HVAC system.
Components of HVAC System
HVAC: heating, ventilating, and air conditioning this is a thermostat: it sends signals to the heating/cooling system.
Heating and Air Conditioning I
Innovative Air Distribution for Healthcare Facilities.
Ductwork Design Arch 432. Attendance The Empire movie theater in Montgomery, Alabama holds the distinction of having the first temperature controlled.
BASICS OF HVAC Ivy Tech Community College. Definitions – Page 862 HVAC systems are made up of the mechanical equipment such as the furnace, air conditioner,
Chilled Beam Presentation
Heating and Air Conditioning I
Objectives Finish with ducts and fans Define project topics.
Airflow Properties & Measurement
System Sizing. Proper System Design Load Calculation Equipment Selection Duct Layout Branch runs Terminations Start ups Customer checks.
Conduction Cooling Loads
ARCH-4372/6372 HVAC Distribution & Sizing HVAC Distribution Systems
Heat Loss & Gain Calculations 1. How Heat Moves in Homes Conduction is the transfer of heat through solid objects, such as the ceilings, walls, and floors.
Energy Conserving Alternatives HVAC 15a CNST 305 Environmental Systems 1 Dr. Berryman.
Active beams versus VAV with Reheat Analysis of May 2013 ASHRAE Journal article Ken Loudermilk Vice President, Technology & Developement.
AIR CONDITIONING SYSTEMS 1. All Air Systems An all-Air System is defined as a system providing complete sensible and latent cooling capacity in the cold.
Refrigeration and Heat Pump Systems Refrigeration systems: To cool a refrigerated space or to maintain the temperature of a space below that of the surroundings.
HVAC523 Heat Gain. Heat First law of thermal dynamics states that HEAT TRAVELS FROM HOT TO COLD. 95 degree outside air will flow through the building.
PSU Building Thermal and Mechanical Systems Laboratory Environment A/E Kurt M. Shank, M.S. & Stanley A. Mumma, Ph.D., P.E. College of Engineering Department.
Lecture 16: Zone Air Paths and Air Distribution Units
 a machine that moves heat from a location to another location, using mechanical work.
Copyright Mestek, Inc What’s High Velocity Air Conditioning?
Important variables Water: Air: Conversion:
Announcements Midterm Project Prepare groups of 3 to 4 students You can submit the list at the end of next class Midterm Exam 03/09/10 - In class Exam:
Lecture Objectives: Finish with HVAC Systems Discuss Final Project.
Basics Air Flow Basics -Air is invisible -Everyone assumes adequate airflow -Frequently airflow is 30%-50% low -Cooling – 400 CFM per ton -Heating.
Ductwork Systems and Supply Arch 432. What You Need To Know Become familiar with the materials sizing ductwork Understand sizing units.
Air Handler Terminology
Drugs Addicts Rehabilitation Center
Air Handler Terminology
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
MECHANICAL ENGINEERING FOR SYSTEM BALANCE ASHRAE MEETING 2/15/2007 NORTHERN NEVADA CHAPTER 126 MATT BRENNAN, TBE.
Objectives Analyze processes in AHU and buildings.
Drafts and Duct System Sizing
HEATING AND COOLING SYSTEMS
IMPROVING THE EFFICIENCY GEOTHERMAL or GROUND SOURCE HEAT PUMPS.
Introduction to Energy Management. Week/Lesson 13 Control Strategies for Occupant Comfort.
Design What is the first step in designing a high-performance building? Would it be: Identify synergies Select the correct HVAC system Design around human.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Row Cooling.
Elbow Sound Attenuator (UPC-26C) Outlet (UPC-56B) Plenum Supply Tubing (UPC-25) Blower Modules (2430,3642, 4860) Heating Module (MH2430, MH3660) Cooling.
Chapter 32 Heating, Ventilation, and Air Conditioning.
HCB 3-Chap 19A: All-Air Systems_Single Zone 1 Chapter 19A: ALL-AIR SYSTEMS: SINGLE ZONE AND SINGLE DUCT Agami Reddy (July 2016) 1)Introduction and common.
Design & Analysis of Psychrometric Processes Various ways of Generating A Comfort… BY P M V Subbarao Associate Professor Mechanical Engineering Department.
Electric-Heat Equipment
Section 6: Air-Conditioning (Heating And Humidification)
Maria’s Restaurant Chapter 1 Section 3
Technology in Architecture
HVAC Basics Arkan Arzesh HVAC – Heating, Ventilation, Air-conditioning.
Psychrometric Chart Basics. Basic Concepts Saturation Line.
Brian Wallingford, Applications Engineer
Chilled Beam Performance:
HCB 3-Chap 19A: All-Air Systems_Single Zone
EMPTY BIN TREATMENTS Mimoun Abaraw.
Frenger “Radiant” chilled beam performance at 1 Shelly St - Sydney
High Performance HVAC Installation
Mandatory Design Requirements
FBE03: Building Construction & Science
Objectives Duct Design AND Diffuser Selection.
Maria’s Restaurant Chapter 1 Section 3
Presentation transcript:

Ductwork Systems and Supply Arch 432

What You Need To Know Become familiar with the materials sizing ductwork Understand sizing units

Ductwork Considerations Shape Size Aspect ratio Velocity Static Pressure of the system Space conflicts

Terms Balanced VAV CV RSH Aspect ratio Velocity Static Pressure of the system

Formulas Btu H / 1.08 (TD) = CFM What is the 1.08? It is the number of Btu H required to increase the temperature of 1 CFM o f air by 1 0 F

Just the Facts One ton of air conditioning capacity is defined as a heat removal rate of 12,000 Btu H Each ton of air-conditioning load usually includes sensible component of 8,000 to 9,000 Btu H. Air handlers typically circulate about 400 CFM for each ton of capacity.

Four Steps for Air Distribution 1) Multiply total tons by 400 to estimate total CFM. 2) Distribute CFM in proportion to floor area. 3) Adjust CFM to reflect anticipated variations in RSH due to specific building conditions. 4) Round off air supply for each room to nearest 25 CFM.

Example A room has a peak winter sensible heat loss of 20,000 Btu H. How much F air must be supplied to maintain room temperature at 70 0 F? The 130 o is off the coils. BTU H/[(1.08)(TD)] = CFM 20,000/[1.08 (130-70)] = CFM 20,000 / 64.8 = = 325 CFM

Example The same room has a peak summer sensible heat gain of 10,000 Btu H. How much 55 0 F air must be supplied to maintain room temperature at 72 0 F? The 55 o is off the coils BtuH/[(1.08)(TD)] = CFM 10,000/[1.08 (72-55)] = CFM 10,000 / = = 550 CFM

Pharmacy Btu H Heat Loss 146,029 Btu H Btu H Heat Gain (Cooling) Sensible 107,200 Btu H Latent 42,339 Btu H

Pharmacy Btu H Heat Loss 146,029 Btu H Btu H/[(1.08)(TD)] = CFM 146,029/[1.08 (130-70)] = CFM 146,029 / 64.8 = 2, = 2,250 CFM Please not that this is one big zone. Need a duct size of 20 x 16 W D

Pharmacy Btu H Heat Gain (Cooling) Sensible 107,200 Btu H Latent 42,339 Btu H RSH/[(1.08)(TD)] = CFM 107,200/[1.08 (72-55)] = CFM 107,200/18.36= 5,839 = 5,850 CFM Please not that this is one big zone. Need a duct size of 24 x 26 W D

Pharmacy Btu H Heat Gain (Cooling) Sensible 107,200 Btu H 107,200/18.36= 5,839 = 5,850 CFM Duct size of 24 x 26 governs Size of Cooling Unit per tons 107,200 / 12,000 per ton = 8.9 or 9 tons

Pharmacy 9 Ton unit x 400 CFM per ton = 3,600 CFM Duct size of 20 x 24

Pharmacy Duct size of 20 x 24 - or - Duct size of 24 x 26 “Velocity pressure is the directional push of an air stream due to its speed” Trost So we trade static pressure and velocity pressure by changing duct size.

Pharmacy Duct size 20 x 24 or Duct size 24 x 26 Static plus Velocity = Total Pressure A decrease in duct size forces air speed and velocity pressure to increase as static pressure decreases. Enlarging a duct will cause air speed and velocity pressure to decrease as static pressure increases.

Facts Insulation ½” 1” or 2” Add two times the thickness of the duct insulation specified. Size return air ducts 2” larger than supply ducts. Reserve 4% of the total building floor area to accommodate air handlers. Reserve 2% of the total building floor area for boilers, chillers, pumps, and electrical switchgear.

Rectangular Lower aspect ratios More energy efficient Use less ductwork Velocity and Area have an inverse relationship to the CFM (CFM = V x A) Velocity and Pressure Drop have a direct relationship Duct dimensions are inside of duct. W D Aspect ratio = W / D 1 to 1

Prof. Kirk’s one-of-a-kind, surefire process guaranteed to result in a mind-numbing law suit.

When Things Go Wrong Mechanical Contractor required to certify that duct plenums were adequately protected

When Things Go Wrong