High rate studies of TRD at GSI (update) D. Gonzalez-Diaz, GSI 27-02-2008.

Slides:



Advertisements
Similar presentations
GEM Chambers at BNL The detector from CERN, can be configured with up to 4 GEMs The detector for pad readout and drift studies, 2 GEM maximum.
Advertisements

Pressure and Kinetic Energy
General Characteristics of Gas Detectors
Radiation Detection ionization chambers (dosimeters, pulse chambers, particle track chambers) scintillation detectors semiconductor detectors photographic.
RPC2010- Darmstadt- 9/12-Feb p.1 M. Abbrescia – University and INFN Bari New gas mixtures for Resistive Plate Chambers operated in avalanche mode.
Drift velocity Adding polyatomic molecules (e.g. CH4 or CO2) to noble gases reduces electron instantaneous velocity; this cools electrons to a region where.
Maximilien Chefdeville NIKHEF, Amsterdam RD51, Amsterdam 17/04/2008
Simulation of the spark rate in a Micromegas detector with Geant4 Sébastien Procureur CEA-Saclay.
Aging, High Rate and Shielding L. Lopes Lip-Coimbra.
1 Gas processes in OTP straw  Questions: HV limit SQS mode Gas gain ??? Location- O:\Data\Osotr1\Presentation3.ppt and O:\Data\Osotr1\chargestudy.ps V.
Proportional Counters
Ionization. Measuring Ions A beam of charged particles will ionize gas. –Particle energy E –Chamber area A An applied field will cause ions and electrons.
1 Seventh Lecture Error Analysis Instrumentation and Product Testing.
1 Alhussein Abuhoza, S. Biswas, U. Frankenfeld, J. Hehner, Ch. Schmidt GSI, Darmstadt, Germany and H.R. Schmidt University of Tübingen, Germany Study of.
Chapter 5 Diffusion and resistivity
Measurement of gas gain fluctuations M. Chefdeville, LAPP, Annecy TPC Jamboree, Orsay, 12/05/2009.
Large-amplitude oscillations in a Townsend discharge in low- current limit Vladimir Khudik, Alex Shvydky (Plasma Dynamics Corp., MI) Abstract We have developed.
Tests with JT0623 & JT0947 at Indiana University Nagoya PMT database test results for JT0623 at 3220V: This tube has somewhat higher than usual gain. 5×10.
Linear Collider TPC R&D in Canada Bob Carnegie, Madhu Dixit, Dean Karlen, Steve Kennedy, Jean-Pierre Martin, Hans Mes, Ernie Neuheimer, Alasdair Rankin,
1 Ankit D. Mohapatra, Dr. Marcus Hohlmann Florida Institute of Technology, Melbourne, Florida Barry University, 8-9 March, 2013.
Systematic studies on the rate capability of MWPC operated in Xe/CO 2 D. Gonzalez-Diaz for the CBM-TRD group March, 2008.
TRD R&D at GSI  Results from test beam 2004  Plans for test beam Feb. 06  Measurements with X-ray stand C. Garabatos, GSI.
Energy-Dispersive X-ray Microanalysis in the TEM Anthony J. Garratt-Reed Neil Rowlands.
LRT2004 Sudbury, December 2004Igor G. Irastorza, CEA Saclay NOSTOS: a spherical TPC to detect low energy neutrinos Igor G. Irastorza CEA/Saclay NOSTOS.
Özkan ŞAHİN & Tadeusz KOWALSKI Uludağ University, Physics Department, Bursa – TURKEY Faculty of Physics and Applied Computer Science, AGH University of.
Özkan ŞAHİN & Tadeusz KOWALSKI Uludağ University, Physics Department, Bursa – TURKEY Faculty of Physics and Applied Computer Science, AGH University of.
Charmonium feasibility study F. Guber, E. Karpechev, A.Kurepin, A. Maevskaia Institute for Nuclear Research RAS, Moscow CBM collaboration meeting 11 February.
The dynamic behaviour of Resistive Plate Chambers
LNF, 26 gennaio Test Beam 2003 Data Analysis and MonteCarlo Studies M. Barone Software and Analysis Meeting ATLAS/Frascati.
Sheffield : R. Hollingworth, D. Tovey R.A.L. : R.Luscher Development of Micromegas charge readout for two phase Xenon based Dark Matter detectors Contents:
Diego González Díaz - Gesselschaft fur Schwerionenforschung (GSI) 1 M.A. Fernandez-Morales, J.A. Garzón, D. González-Díaz.
Geant4 Simulation of Neutrons interaction with GEM-foil and gas Gabriele Croci, Matteo Alfonsi, Serge Duarte Pinto, Leszek Ropelewski, Marco Villa (CERN)
1 TRD-prototype test at KEK-FTBL 11/29/07~12/6 Univ. of Tsukuba Hiroki Yokoyama The TRD prototype is borrowed from GSI group (thanks Anton).
Ionization Detectors Basic operation
2nd RD51 Collaboration Meeting, Paris, October PENNING TRANSFERS Ozkan SAHIN Uludag University Physics Department Bursa -Turkey 2nd RD51 Collaboration.
Experimental and Numerical studies on Bulk Micromegas SINP group in RD51 Applied Nuclear Physics Division Saha Institute of Nuclear Physics Kolkata, West.
Preliminary results of a detailed study on the discharge probability for a triple-GEM detector at PSI G. Bencivenni, A. Cardini, P. de Simone, F. Murtas.
Muon Drift Tube Gases Chris Clark Advisors: Rachel Avramidou, Rob Veenhof.
I. Giomataris NOSTOS a new low energy neutrino experiment Detect low energy neutrinos from a tritium source using a spherical gaseous TPC Study neutrino.
Diego González-Díaz (GSI-Darmstadt) GSI, now R3B!
The effect of surface roughness
TCPD test measurement 1 TCPD (TGEM CCC Photon Detector) test measurement ELTE, MTA KFKI RMKI, REGARD Group (Budapest, Hungary): Levente Kovács G. Hamar,
EUDET Meeting, Munich – October 18, Ongoing activities at Saclay David Attié D. Burke; P. Colas; E. Delagnes; A. Giganon; Y. Giomataris;
Özkan ŞAHİN & Tadeusz KOWALSKI Uludağ University, Physics Department, Bursa – TURKEY Faculty of Physics and Applied Computer Science, AGH University of.
Özkan ŞAHİN & Tadeusz KOWALSKI Uludağ University, Physics Department, Bursa – TURKEY Faculty of Physics and Applied Computer Science, AGH University of.
Construction and Characterization of a GEM G.Bencivenni, LNF-INFN The lesson is divided in two main parts: 1 - construction of a GEM detector (Marco Pistilli)
MPGD (RD-51) Workshop Nikhef, Amsterdam, April Penning Effect on Gas Amplification Factor Ozkan SAHIN Uludag University Physics Department.
meeting, Oct. 1 st 2015 meeting, Oct. 1 st Gas Pixel: TRD + Tracker.
Calibration of energies at the photon collider Valery Telnov Budker INP, Novosibirsk TILC09, Tsukuba April 18, 2009.
1 A two-phase Ar avalanche detector with CsI photocathode: first results A. Bondar, A. Buzulutskov, A. Grebenuk, D. Pavlyuchenko, R. Snopkov, Y. Tikhonov.
Özkan ŞAHİN Uludağ University Physics Department Bursa – TURKEY Survey of transfer rates using Zaragoza (Xe – TMA) and Krakow (Ar – CO 2 ) measurements.
Penning transfers: survey of available data, life-time of excited states, pressure dependence Ozkan SAHIN Uludag University Physics Department Bursa -TURKEY.
Single GEM Measurement Matteo Alfonsi,Gabriele Croci and Bat-El Pinchasik June 25 th 2008 GDD Meeting 1.
Endplate meeting – September 13, Gas issues for a Micromegas TPC for the Future Linear Collider David Attié D. Burke; P. Colas;
Particle identification by energy loss measurement in the NA61 (SHINE) experiment Magdalena Posiadala University of Warsaw.
R&D Collaboration, CERN – September 10, Micromegas Performance and Ageing studies David Attié MPGD. Towards an R&D Collaboration,
14/02/2008 Michele Bianco 1 G.Chiodini & E.Gorini ATLAS RPC certification with cosmic rays Università del Salento Facoltà di Scienze MM.FF.NN.
RPCs with Ar-CO2 mix G. Aielli; R.Cardarelli; A. Zerbini For the ATLAS ROMA2 group.
R&D on Hadron Blind detector, recent results Issues addressed: - gain limits in CF 4 with heavily ionizing particles - operation.
1 straw tube signal simulation A. Rotondi PANDA meeting, Stockolm 15 June 2010.
Part-II Wire type detectors 1. Single wire counters.
Activities on straw tube simulation
Secondary avalanches in gas mixtures
Saikat Biswas, A. Abuhoza, U. Frankenfeld, C. Garabatos,
Numerical simulations on single mask conical GEMs
p0 life time analysis: general method, updates and preliminary result
Ionization detectors ∆
THGEM report – january, 22nd 2009
Gain measurements of Chromium GEM foils
Presentation transcript:

High rate studies of TRD at GSI (update) D. Gonzalez-Diaz, GSI

Experimental setup

Fit to exponential curves and determination of the glow discharge voltage. glow discharge

Slopes of the gain curve

The onset of the glow discharge

chamber unstable (not understood yet) maximum gain roughly constant maximum gain depends on the fraction of quencher

● Chamber parameters: s=4 mm, h=3 mm. ● Fit parameters: μ noble and μ CO2 combined by assuming the Blanc's additive law (with f being the fraction of noble gas): Global fit to the Mathieson formula

Xenon A. Kalweit

Argon G.Hamar

Neon

After obtaining the parameters of the fit (2x3 mobilities), the rate capability r at arbitrary gain drop F can be re-obtained as: Rate capability.

systematic error Rate capability. A handy representation. ΔE = 6.7 keV~2 ΔE mips CBM goal

Beam size dependence r [mm] Preliminary A. Kalweit Therefore: the rate capability is overestimated by the same factor (an independent measurement with de- focused beam points also to a factor around 0.6).

very conservatively one can assign a systematic uncertainty of up to a factor 2x2 [maximum] in the rate capability (more systematic measurements are on the way!)

Some scalings

Gap h (~1/h 2 )

Wire pitch s (~1/s)

Gain drop F (~F)

Gain M o (~M o )

Conclusions. ● Existing data (from different measurements conducted at GSI) on gain and rate capability was compiled and re-analized by using a common framework. A rate capability of 100x2 Hz/cm 2 for mips at M o =10 4 and F=5% drop was demonstrated on 3 mm gap chambers with 4 mm pitch. ● The uncertainty coming from the finite beam size and partially inconsistent sets of data is conservatively below a factor 4. ● The rate capability improves linearly with M o F. Therefore, operation of this geometry at gains below 10 4 provides a safe margin regarding the rate capability required by CBM (100 Hz/cm 2 ), a wide dynamic range for primary ionizations (glow discharge at M o ~ for Xenon) and reduced ageing. ● Measurements will continue in order to reduce the systematic uncertainties and to extract the ion mobilities and compare with existing data. ● Hopefully next meeting we can show the final picture!

Appendix

Experimental procedure for gain measurements. ● The rate was monitored with a CAMAC scaler and corrections for the system dead-time applied. In these measurements this correction is at most 13%. ● The current was measured with a power supply of 1 nA resolution. At low gains, a Keithley picoamperemeter with resolution below pA was used. ● The pressure and temperature were monitored continuously, and the operating voltage re-normalized to the corresponding voltage at P=1000 bar and T=20 o C, to account for changes in density. ● The rate over the chamber was kept at the level of 10 kHz for gains M>10 5 and at the level of 120 kHz for gains M<10 5 (this reduces the space-charge at high gains, simplifying the theoretical description). This was achieved for all the gas mixtures studied, by accommodating the different X-ray conversion probabilities with changes in the current of the tube. ● Measurements for s = 2, 3, 4 mm and gas mixtures of Ne,Ar,Xe/CO 2 at concentrations of noble gas f = 0, 10, 20, 40, 60, 80, 90, 99 were performed

X-ray tube vs (reference) Fe 55 source (I). The energy distributions are very similar but, in the case of the source, the measured distribution is dominated by the detector resolution and in the case of the tube it is dominated by the shape of the primary X-ray distribution. Ar/CO 2 (80/20) escape peak

SO: Once calibrated in energy, the tube was used for the whole data taken X-ray tube vs (reference) Fe 55 source (II). Good mutual agreement (below 5%) between both!

2.1. Measurements on gain.

Typical measurements (Xenon). Curves fitted to the phenomenological expression

Typical measurements (Argon). Curves fitted to the phenomenological expression

Gain systematics as a function of the fraction of Xenon and chamber pitch s.

Gain systematics as a function of the gas mixture.

2.2 The glow-discharge.

The glow discharge. Photon or ion feedback may result in re-generation of electrons close to the cathode that causes a self-sustained current in the detector (glow-discharge). A. Battiato In this kind of mixtures and at this temperature and pressure conditions, it is the main cause of gain limitation of the detectors

Maximum gain before the onset of the glow discharge for Xenon. The maximum achievable gain is rather independent on the quencher, being suggestive of the presence of ion feedback. PRELIMINARY!

Maximum gain in Neon and Argon mixtures depend strongly on the quencher, being suggestive of photon feedback. Maximum gain before the onset of the glow discharge for different gas mixtures. PRELIMINARY!

Comparison with models (Magboltz). Meta-stable Ar * always appear during the avalanche process. If Ar * finds a CO 2 molecule, it can be de-excited upon ionization of it (Penning effect). The fraction of Ar * atoms that undergoes Penning or ‘Penning fraction’ is a free parameter, but can be constrained by our data since it depends only on the mixture. C. Garabatos Ar/CO 2 (80/20) PRELIMINARY!

2. Measurements on rate capability.

Experimental procedure for rate capability measurements. ● The gain was measured as a function of the primary rate. The dead-time of the system was estimated (and corrected) by making use of the proportionality between the current of the X-ray tube and the primary rate, and using a phenomenological model with only 1 free parameter. ● The area of illumination has been measured by exposing a Polaroid film. ● The current was measured through the power supply. ● The rate was measured with a NIM scaler.

Rate capability. The ‘standard model’ (I). E. Mathieson, NIM A 249(1986)413 In the particular case where, the dependence of the gain with rate is given by the transcendental equation: Where n o is the initial number of clusters, φ the primary flux in [Hz/cm 2 ], C l is the capacitance per unit length, μ the ion mobility, s the wire pitch and h the gap between anode and cathode.

Rate capability. Data and model. XENON. A. Kalweit Xenon/CO 2 (90/10)

A. Kalweit Rate capability. Data and model. XENON. Xenon/CO 2 (80/20)

Rate capability. Data and model. ARGON. G. Hamar

Rate capability. Data and model. ARGON. G. Hamar

Rate capability. Data and model. NEON.

Rate capability. The ‘standard model’ (2). From expression: The flux at arbitrary drop in gain (F), can be obtained: That we denote as ‘rate capability’

Parameters of the model: ● For the mobility it is assumed that it is the CO 2 who actually drifts and the Blanc’s additive law is valid. The values of the mobility in pure gases are then obtained from existing tables. For simplicity, the mobility at zero field is taken and assumed to be constant. ● For the primary ionization, the values reported in Sauli’s yellow paper are used. ● The mobility of CO 2 + in Xe has not been directly measured (up to my knowledge) so I took as an ansatz that the mobility of Xe + in Xe scales to the one of CO 2 + in Xe in the same way that Ar + in Ar scales to CO 2 + in Ar. Rate capability. The ‘standard model’ (3).

Rate capability. All in one. PRELIMINARY! required by CBM

Conclusions. ● The gain and rate capability has been measured for several chambers and gases, and seems to be reasonably well described by transport models (Magboltz). ● The maximum operating gain in Xenon mixtures is systematically below Argon and Neon. ● The rate capability of the chambers has been measured and is well described within 20% for Xenon, Argon and Neon mixtures by using the Mathieson formula. The good agreement gives some confidence on how to extrapolate to different geometries, mixtures and primary ionization. ● Given the energy loss for mips in Xe (ΔE~5 KeV/cm), it seems that the rate capability in Xe/CO 2 based mixtures for 4 mm chambers and M=10 4 fits to the CBM requirements. Drops in gain are expected to be below 5%.

Outlook. ● Improve the quality of the analysis of the existing data on rate capability under X-ray illumination. In particular, the existing data has been analyzed independently by different people. ● An assessment of the dependence of the rate capability with the beam size must be pursued before extracting further conclusions. ● Analysis of data under illumination with ionizing particles will be pursued in short term.