Metering Standards and Impact on Shrinkage Issue for Consideration 1 October 2009 for Gas Transmission Workstream.

Slides:



Advertisements
Similar presentations
Place your chosen image here. The four corners must just cover the arrow tips. For covers, the three pictures should be the same size and in a straight.
Advertisements

EU 3 rd Package Clarification of points raised at Transmission Workstream 3/12/2009.
Place your chosen image here. The four corners must just cover the arrow tips. For covers, the three pictures should be the same size and in a straight.
1 Use of commingling to avoid propane addition at biomethane injection points  Objective of the measurement regime for CV  Protect downstream customers.
Place your chosen image here. The four corners must just cover the arrow tips. For covers, the three pictures should be the same size and in a straight.
Information Transparency Proposal Transmission Workstream 2 nd November 2006 Presentation by Abid Sheikh, energywatch and Angela Love, Poyry Energy.
Place your chosen image here. The four corners must just cover the arrow tips. For covers, the three pictures should be the same size and in a straight.
KEY CONSULTATIONS an overview Louise Masters InnogyOne, Innogy UK Offshore Wind 2003.
Orifice Plate Meter Error Stuart Gibbons, Extraordinary Offtake Arrangements Workstream Meeting: 16 October 2009.
Accuracy of CV determination systems for calculation of FWACV Dave Lander.
UNC Modification Proposal 0116 Reform of the NTS Offtake Arrangements Transmission Workstream 5 th October 2006.
Operating Margins. 2 Competitive Provision of Operating Margins Change to National Grid Gas’s Transporter Licence which:  Introduced Special Condition.
The economic regulation of gas processing services Key issues and initial thoughts Ofgem presentation 18 June 2007.
NTS to LDZ Meters – Audits & Validations Created by Alison Chamberlain on behalf of Transporters, for meeting 6 th August, 2010, 31 Homer Road Solihull.
Moving the QSEC and AMSEC Auctions National Grid NTS, Transmission Workstream.
Energy Networks Association Flow Weighted Average Calorific Value Options Biomethane Campaign Working Group 7 th August 2014 The Voice of the Networks.
Offtake Metering Errors Stephen Skipp Asset Manager (Transmission and Storage)
Mod 0445 – Amendment to the Arrangements for Daily Metered Supply Point Capacity Ofgem Direction to Provide Further Evidence National Grid Distribution.
Entry Capacity Release Methodology Statement Transmission Workstream, 4 th May 2006.
SO Incentives from April 2010 John Perkins. 2 Gas System Operator (SO) Incentives National Grid operates the high pressure Gas Transmission System in.
Sunday, 04 October 2015 UNC Mod Action WG0505: Provide for discussion/development the potential categories of connection offer and associated timescales.
Accuracy of CV determination systems for calculation of FWACV Dave Lander Update 12 th October 2011.
Review Group 291 – Balancing Arrangements Default Cashout Workshop 3 – 21 st June 2010.
Provision of third party access to licence exempt electricity and gas networks Andy Pace 4 October | Energy Networks Association - DCMF.
Mod 0333: Update of default System Marginal Prices Review Group August 2010 Transmission Workstream 07/10/2010.
UNC Proposal 329 – Review of Industry Charging & Contractual Arrangements - DM SHQs and DM SOQs Joel Martin – 21/09/10.
Offtake Arrangements Document – An Overview Paul Roberts 12 th May 2005.
UNC modification proposal 0407 : Standardisation of notice periods for offtake rate changes for all National Grid NTS Exit Users Transmission Workstream.
1 Operating Margins – Request for Proposals Transmission Workstream 6 th April 2006 Dave Smith, National Grid NTS.
Force Majeure - Capacity Transmission Workstream 2 July 2009.
Modification proposal 0073 ‘Revision to the Notice Period regarding the implementation of changes to Transportation charges’ Transmission Workstream, 2.
Exit Capacity Substitution and Revision Transmission Workstream meeting, 3 rd December 2009.
1 Transmission Work Group 1 st November 2012 Gas Security of Supply SCR Proposals Credit Implications for GB Gas Market EBCC Response Summary Mark Cockayne.
DN Operation Iain Ward DNCC Manager. Responsibilities  Licence Holder  Obligation For 1 In 20 Capacity  DNCC Operates Networks Under Direction of The.
Place your chosen image here. The four corners must just cover the arrow tips. For covers, the three pictures should be the same size and in a straight.
Modification Proposal 0395 & 0398 – Limitation on Retrospective Invoicing and Invoice Correction 1 st December 2011.
Customer Charge On behalf of all DNs 25 October 2010.
Emergency Cashout Prices and Emergency Curtailment Quantity (ECQ) Adjustment Ritchard Hewitt Gas Code Development Manager.
Draft Modification Proposal: Population and Maintenance of Market Sector Code within Sites & Meters Simon Trivella –25 th February 2010 Distribution Workstream.
Code Governance Review UNC Modification Proposals Beverley Viney - National Grid NTS.
Transmission workstream 6 April Overview of TPCR Third Consultation UNC transmission workstream – 6 April Mark Feather.
Place your chosen image here. The four corners must just cover the arrow tips. For covers, the three pictures should be the same size and in a straight.
Facilitating Release of Non-obligated Entry Capacity Draft – for discussion purposes only 22 November 2007.
“Amendment of Network Entry Provisions at the European Interconnector NTS sub- terminal at Bacton" Transmission Workstream 1 st December 2005.
Mark Dalton 4 February 2010 Transmission Workstream Discussion slides.
RIIO Gas Transmission Workshop - 5 th Sept Supplementary information 1 Hypothetical examples to illustrate the impact of combining the constraint management.
Energy Market Issues for Biomethane Projects Workshop - 31 October 2011 RIIO-GD1 Environmental Incentives.
Review Group -140 Thoughts on additional information requirements.
Review of Offtake Arrangements Document Section I - NTS Operational Flows 10 th June 2010 – Offtake Arrangements Workstream.
23 February 2011 IGTRP0030 Potential impacts on Parties of changes to NExA Table.
System Operator information transparency. As Transmission System Transporter National Grid Gas undertakes responsibility for safe, effective and efficient.
Stuart Forrest, Network Planning Manager, Scotia Gas Networks 19 th October 2010 MOD Review of Industry Charging & Contractual Arrangements in Relation.
Horndon Temperature Error (SMER)
Modification Proposal 0283 Update
Code Governance Review UNC Modification Proposals
Transmission Workstream 4th July 2007
Action 0002: Meter Error Notifications
UNC Review Group 0251 Metering Issue for Consideration
Amendment to NEA & NExA Measurement Provisions Change Process
0291 – NTS Licence Special Condition 27 – Balancing Arrangements
LDZ Offtake Meter Orifice Plate Error
Exit Capacity Substitution and Revision
Long Term Non Firm Capacity Update
Modification Proposal Amendment of IUK’s Minimum Wobbe Limit
Transmission Workstream 6th November 2008
Information Provision for Transitional Exit Capacity
CAM: Next Steps UNC Transmission Workgroup Lisa Martin 9 January 2014.
Stefan Leedham Transmission Workstream 2nd November 2006
Commercial Arrangements For Gas Quality Service – Introduction
Gas Customer Forum 28 July 2008
Presentation transcript:

Metering Standards and Impact on Shrinkage Issue for Consideration 1 October 2009 for Gas Transmission Workstream

2 Metering - Governance Background Metering is Governed by DECC and Ofgem DECC: offshore (terminals); Ofgem: networks Regulations provide prescriptive arrangements (GCOTE 1997) Metering predominately Orifice plates (120 GDNs / 60 NTS) Purpose for metering developed over time; originally network balancing, system control

3 Ofgem Governance Provided for within the GCOTE Scope for CV and metering Requires sites to be directed, setting out performance requirements and Letter of approval Charging areas defined by industry Declared or FWACV can be operated FWACV seeks to protect consumers (1MJ/m^3 c2.5%)

4 Metering Standards Orifice plates standard ISO 5167 UNC OAD appendix D sets out requirements 1.1 % on volume Disconnect between entry and exit 1991 Vs 2003 Supplementary agreements allow greater uncertainty? –0 to 30% of flow, +/- 3.6% –30 to 100 % of flow, +/- 2.1%

5 ISO 5167 ISO standards updated approximately every 5 years Changes to ISO 5167 – 2003 –1. Discharge Coefficient –2. Expansibility Factor –3. Permanent Pressure Loss –4. Upstream Temperature Considered that 1991 overstates when compared to 2003 by approximately 1%, depending upon meter configuration

6 Other Factors and consideration Fixed factors for –Pressure –Temperature on%20document%2027%2012.pdf

7 Moving the debate forward To what extent does the difference in standards and range of uncertainty contribute to shrinkage Winners and losers Are localised factors more applicable –Offtake –Consumers meters This is an area for further work and investigation