Refrigerator and Freezer Decommissioning: Deemed Measure Review and Update Regional Technical Forum June 1 st, 2010.

Slides:



Advertisements
Similar presentations
New Paradigms for Measuring Savings
Advertisements

©2011 Navigant Consulting, Inc. Confidential and proprietary. Do not distribute or copy. ENERGY DISPUTES & INVESTIGATIONS ECONOMICS FINANCIAL ADVISORY.
E3 Calculator Revisions 2013 v1c4 Brian Horii June 22, 2012.
1 Analysis of Cost and Savings Values for Revised Energy Star Freezers and Refrigerators June 6, 2006 Revised August 8, 2006.
Residential Refrigerators and Freezers UES Measure Update Regional Technical Forum October 14, 2014.
Direction on Guidelines Savings Definition Path Results of straw vote and proposed decisions for elements of the savings definition Regional Technical.
The Saga Continues: Measure Interactions for Residential HVAC and Wx measures Regional Technical Forum April 23, 2014.
Heat Pump Water Heaters Provisional UES Proposal Regional Technical Forum October 4 th, 2011.
Grocery Measure: LEDs for Reach-In Display Cases Regional Technical Forum July 21 st, 2015 Mohit Singh-Chhabra.
LED Case Lighting With and Without Motion Sensors Michele Friedrich – Sr. Engineer PECI 1/5/2010.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Savings of Specialty CFLs and LED Downlights Danielle Gidding Bonneville Power Administration.
BPA Pre-Pilot, Monmouth  14 homes with installed DHP, single zone, single compressor.  11 Monmouth, 2 Moses Lake, 1 Tacoma  Savings.
Overview of the 2009 LIEE Impact Evaluation Workshop 1: “Overview of Lessons Learned” October 17, 2011.
Residential Refrigerator & Freezer Decommissioning Measure Update May 13 th,
Night Covers on Open Vertical Cases Provisional UES Proposal Presentation to the Regional Technical Forum August 30,
Advanced Power Strips (APS) Planning UES Measure Proposal Regional Technical Forum August 20, 2013.
Implementer’s Group April 2015 Meeting Debrief and Upcoming Meeting Prep April 24, 2015.
Methodology for Energy Savings claim for Incentive Programs and Codes & Standards(C&S) accounting Presented by: Armen Saiyan P.E. For the California Technical.
Plans to bring Out-of-Compliance UES Measures back into Compliance: 1. Agricultural Irrigation Hardware UES 2. Agricultural Motors UES Regional Technical.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Residential Appliance Measure Updates Danielle Gidding Bonneville Power Administration.
Capacity Impacts of Energy Efficiency What We Know and What We Don’t Know March 11, 2014.
Overview of the Regional Technical Forum Guidelines January 22, 2013.
Non-Residential Network Computer Power Management UES Measure Update Regional Technical Forum July 16, 2013.
Pre-Rinse Spray Valve Small Saver UES Measures Regional Technical Forum September 17, 2013.
Scientific Irrigation Scheduling provisional analysis and research plan BPA December 2014.
Residential Behavior Programs RTF Subcommittee Ryan Firestone September 17, 2015.
Northwest Power and Conservation Council Slide 1 Direct Use of Natural Gas Economic Fuel Choices from the Regional Power System and Consumer’s Perspective.
Out-Of-Compliance Grocery UES Measure Recommendations Regional Technical Forum March 18, 2014.
Grocery Measure: EC Motors for Display Cases Regional Technical Forum July 21 st, 2015 Mohit Singh-Chhabra.
Grocery Measure: EC Motors for Display Cases Regional Technical Forum June 16 th, 2015 Mohit Singh-Chhabra.
Development and Deployment of A Standardized Savings and Economic Valuation System for Tracking Conservation Resource Acquisitions in the PNW Presented.
Strip Curtains for Refrigerated Walk-in Boxes Michele Friedrich, PE – Sr. Engineer Eric Mullendore – Energy Analyst PECI 8/3/2010.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Residential Appliance Measure Updates Danielle Gidding Bonneville Power Administration.
Heat Pump Water Heater Request for Feedback on a proposal to add UES measures with a “Retail – any installation location” delivery mechanism Regional Technical.
Refrigerator Decommissioning: Measure Status Update Regional Technical Forum October 16, 2013.
Experience you can trust Refrigerator and Appliance Recycling Program Evaluation CALMAC/MAESTRO Meeting San Francisco, CA July 26, 2006 Tami Rasmussen.
Anti-Sweat Heater Control Small Saver UES Measure Regional Technical Forum September 17, 2013.
Deemed Savings Update: ECMs in Display Cases Ben Cartwright PECI January 5, 2009.
UES Measure Updates: Refrigerator and Freezer Recycling Adam Hadley Regional Technical Forum June 16, 2015.
An Approach to Adjust ERCOT’s Long-Term Load Forecast for Utility Energy Efficiency Programs Jay Zarnikau Frontier Associates LLC June 10, 2013.
BPA M&V Protocols Overview of BPA M&V Protocols and Relationship to RTF Guidelines for Savings and Standard Savings Estimation Protocols.
Experience you can trust. Phase 1: Cataloguing Available End-Use and Efficiency Load Data September 15, 2009 End-Use Load Data Update Project.
Ben Chou NRDC Water Program Clothes Washer Recycling Work Paper Abstract California Technical Forum October 23, 2014.
1 Proposed Deemed Savings Values for Residential Refrigerator Recycling Programs June 7, 2005.
EMV Results for online Energy Education Study conducted by Lei Wang, PhD October 2011.
Integration Issues for RTF Guidelines: Savings, Lifetimes and Cost/Benefit October 24, 2012 Regional Technical Forum Presented by: Michael Baker, SBW.
High Efficiency Evaporator Coils for Medium Temperature Cases Dustin Bailey, Engineer PECI Jan 5, 2010.
Guidelines Revisions Defining What RTF Means by “Savings” December 17,
T12 to HPT8 Change-outs Small/Rural request for development May 15, 2012.
M o n t r e a l P r o t o c o l M O P - 2 6, N o v e m b e r , P a r i s 1 TEAP XXV/8 Task Force Report SUPPLEMENT to the Assessment of.
Residential: Appliances Refrigerator/Freezer Decommissioning: Early Retirement and Recycling May 15, 2012 Measure Status Change Recommendation.
Refrigerator Recycling UES Measure Subcommittee Adam Hadley Subcommittee of the RTF September 1, 2015.
Utilities’ Update on Energy Savings Assistance Program Studies Ordered in D LIOB Meeting August 21, 2013 Sacramento, California.
Scientific Irrigation Scheduling Subcommittee Thursday, August pm – 3pm, PDT.
Regional Technical Forum Recommissioning commercial retail facilities: A whole building approach to energy savings April 7th, 2009 Presented by: Jeremy.
Experience you can trust. Californial Industrial Energy Efficiency Potential CALMAC/MAESTRO Meeting San Francisco, CA July 27, 2006 Fred Coito
Residential Refrigerator UES Measure Update Regional Technical Forum April 16, 2013.
ENERGY STAR Commercial Refrigerators and Freezers Regional Technical Forum January 21 st, 2016 Mohit Singh-Chhabra.
D EEMED M EASURE U PDATES May 3, 2011 Regional Technical Forum Presented by: Bob Tingleff SBW Consulting, Inc.
1 Summary of Reviews: Workpapers Approved by the California Technical Forum Part 2 Meeting: California Technical Forum January 28, 2016 Jeff Hirsch/Kevin.
Non-Residential Network Computer Power Management Christian Douglass Regional Technical Forum January 21, 2016.
Residential Single Family Clothes Washer UES Measure Update Regional Technical Forum September 16, 2014.
Exterior LED Area Lights
Residential Behavior-based Programs Measure Development Update Ryan Firestone Regional Technical Forum March 15, 2016.
DNV GL © 2016 SAFER, SMARTER, GREENER DNV GL © 2016 HVAC 3 Quality Maintenance Program Year Impact Evaluation.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat UES Measure Update Regional Technical Forum June 17, 2014.
Existing Condition Baseline Programs & Codes and Standards
Behavior Modification Report with Peak Reduction Component
EM&V Planning and EM&V Issues
Presentation transcript:

Refrigerator and Freezer Decommissioning: Deemed Measure Review and Update Regional Technical Forum June 1 st, 2010

Overview of Measure Measure Description – Early retirement of residential refrigerators and freezers curbside-pickup: main method retailer-pickup: programs beginning to explore this option Measure Requirement – Must be in working condition (makes cold) – At least 10 ft 3 in capacity – Must be decommissioned and its components recycled History – Originally, RTF established a deemed calculator – June 2005 – RTF established deemed savings for residential refrigerator recycling – April 2007 – RTF established deemed savings for residential freezer recycling Scale & Available PNW Data – 7 PNW Utilities’ 2009 programs recycled 34,000 units Translates to nearly 4 aMW using current RTF values – Data collected by JACO in the following utility programs: Avista, ETO, Snohomish, Tacoma, Seattle, PSE, and Idaho Power Current Deemed Measures: 2

Measure’s Relationship to 6 th Plan Reason(s) it's not in the Plan The Plan already accounts for savings from natural replacement of the existing stock. – The baseline condition is "standard practice" efficiency of new equipment at the start of the Plan (2010). – With a 20-year life, all refrigerators get replaced during the planning period with at least the baseline condition efficiency. Savings from refrigerator decommissioning only last until the unit would be replaced on normal burnout, something well short of 20 years. – The savings from existing equipment efficiency to current standard practice efficiency are already "locked in" since codes/standards/standard practices are not assumed to go backward. – There is no additional savings potential over the long-term from decommissioning. The Plan acknowledges it does not provide an exhaustive list of all the available cost-effective measures that can be performed over the next 20 years. Reason(s) utilities can claim "early retirement" savings Decommissioning saves energy. Decommissioning gets the Region to the long-term target early (speeds up natural replacement) – Assuming the savings are cost-effective, this adds value to the Region. – Cost-effectiveness depends on a number of factors how programs are structured, the natural replacement cycle, the age distribution of the stock being decommissioned, the cost of the decommissioning, the timing and depth of future improvements in standards, etc. Note: Since savings from refrigerator decommissioning are much like the savings achieved with code/standard changes, we have to take care not to count them twice when reporting regional savings in the regional roll-up. 3

Measure Analysis Overview Energy Savings = (kWh old )×(F partuse ) ×(Net adjustment ) kWh old : Average Annual Energy Use of Recycled Refrigerators (and Freezers) F partuse : Part-Use Factor Takes into account units that would have been operated part of the year, or not at all Net adjustment : Net Savings Adjustments – Takes into account units that would have been taken out of service without the program Measure Life = Remaining Useful Life of the Equipment Measure Cost = Collection Cost + Recycle Cost 4

“It is clear that, despite over a decade of practice, evaluations of appliance recycling programs continue to suffer from significant uncertainty in key performance parameters.” [Eric Daly, Val Jensen, and Bruce Wall] “Evaluation of the Energy and Environmental Effects of the California Appliance Early Retirement and Recycling Program,” Energy Program Evaluation Conference, Seattle,

Site/Lab Factor: Adjustment for DOE test lab performance to in situ performance kWh at-manufacture: AHAM (extrapolated) average annual energy use for model year kWh degradation: Increased energy use from efficiency degradation over time (kWh degradation i = unit age i x performance degradation factor) n: # units recycled in 2009 (JACO 2009 PNW data) C: correction factor to adjust 2009 data to a deemed value for Energy Savings Determining kWh old

Site/Lab Factor = ReportSummaryResults (Ratio of In-situ to Lab Energy Use) Notes Peterson, John et. al. “Gross Savings Estimation for Appliance Recycling Programs: The Lab Versus In situ Measurement Imbroglio and Related Issues.” 2007 IEPEC 202 units were tested both In- situ (2 weeks) and in the lab (following DOE protocol) 0.81Chose results for “cooler” CA climate to crosswalk to PNW climates. (Table 12) Cadmus, et. al. “Residential Retrofit High Impact Measure Evaluation Report”. For the CPUC. 2/8/2010 Added sites to above. In situ monitoring (166) and lab monitoring (137). 0.81Simple average of “cool” CA climates (Table 123) Issue: DOE Lab Test at 90 deg ambient, empty, no door openings.

Energy Savings Determining kWh old kWh At-Manufacture AHAM Energy Use Data – Average manufacturer-reported at-manufacture energy use, by year of production. – Data back to 1970’s; extrapolated beyond that – These are the data used by the current RTF analysis JACO Energy Use Data (not used in savings calc) – At-manufacture energy use by model – Data available for some, but not all 8

AHAM: Market Average, with extrapolation in earlier years; JACO: Average of models with a match 9

10

AHAM: Market Average, with extrapolation in earlier years; JACO: Average of models with a match 11

12

ReportSummaryResultsNotes ADM. “2009 Second Refrigerator Recycling Program NV Energy – Northern Nevada Program Year 2009; M&V Report.” Feb 2010 Reference to Cadmus data on CA program (2/2010 report) 1.25% per year Methodology not described Miller and Pratt, “Estimates of Refrigerator Loads in Public Housing Based on Metered Consumption Data”, October 1998 Metered 104 existing & 17 new units. Developed a regression function, with age as a variable. 1.37% per Year 1998 KEMA. “2003 EM&V RARP Study: Verification, Degradation & Market Potential Analysis”. For SCE. Dec Using data from 136 lab (DOE) metered “old” units, compared to new consumption data, tried to find a relationship. (93% of the units showed increased usage) Couldn’t provide a quantitative conclusion ICF Consulting. “Evaluation of the Energy and Environmental Effects of the California Appliance Early Retirement and Recycling Program” for CPUC Referenced in SnoPUD evaluations (did not find original report) 0.6% per year Energy Savings Determining kWh old Performance Degradation Factor = 1.25%/year 13

Energy Savings Determining kWh old C Factor = Issue – JACO data represent mix of models recycled in 2009; however, deemed savings are for 2010 and beyond (proposed 2-year sunset date) Suite of units recycled are expected to be of newer vintages (and therefore, more efficient) over the course of program delivery as older units are removed from circulation through the program and naturally. So, kWh old should be expected to fall over time. Solution – C Factor Adjusting the 2009 model years by +1, +2, and +3 years, results in: – Refrigerators: 97% (2010) to 91% (2012) of savings calculated for 2009 – Freezers: 98% (2010) to 92% (2012) of savings calculated for 2009 Assumes same recycled model age distribution as occurred in 2009 – Sunset Date: 2 years Adjust savings based on most recent program model year data

Energy Savings Determining F partuse Part Use Factor = 0.91 Based on participant surveys (Cadmus, 2010) Simple Average combined factor for the three utilities =

Source: SnoPUD Evaluation – What consumer would have done References to: ICF 2003, Heschong Mahone 2002, ICF 2003, and City of Fort Collins 2005 – Whether replaced JACO data collected through program Where replaced with a new unit, new unit’s consumption is subtracted – This reduces the NTG to 57% (assuming error is fixed) Uncovered an error or two – Energy use of models newer than the average (1980) are not included in the average UEC – NTG is not summed properly 16 Current RTF Energy Savings Determining Net adjustment

What would have happened to the Refrigerator or Freezer without the Program? 17 Energy Savings Determining Net adjustment 1.Would have kept, but not used 2.Would have discarded, and unit destroyed 3.Would have kept and used 4.Would have discarded, but unit still in use - Net Adjustment is typically determined through participant and non-participant surveys. - Analysis can be complicated and varies. Subject to a Net Adjustment Not Subject to a Net Adjustment

18 Energy Savings Determining Net adjustment Net adjustment = 57% (refrigerators); 68% (freezers)

19 Energy Savings Issue/Discussion Proposed Net Adjustment method assumes a 1-for-1 reduction in the # of refrigerators remaining in the population. (Less refrigerators per household) This assumption causes an overstatement of savings. -In some cases, units that are recycled would have been used* in a “required” situation. Because of the program, the user* is forced to acquire an alternative unit. -On average, we would expect the efficiency of the alternative unit to be higher than the efficiency of the recycled unit -In these cases, savings should be kWh RecycledUnit – kWh AlternativeUnit, not simply kWh RecycledUnit However, there are no data to support an adjustment. -Example: Existing RTF method subtracts the new unit’s energy use for all units reported by program participants as “replaced with a new unit”; and assigns 0 kWh/yr savings to all units reported as “replaced with a used unit”. Issue: Program participant responses are mostly irrelevant to this issue; whether the subsequent user* would have used the unit in a “required” situation is relevant (and unknown). -What value to use for kWh AlternativeUnit ? Solution: (?) Likely a small effect, so ignore it. * The “user” in this case could be the program participant, or the next would-be owner of the unit.

Energy Savings Recap & Results 20 Energy Savings = (kWh old )×(F partuse ) ×(Net adjustment )

Measure Life Continue using RTF’s relationship of age to measure life (graph) – Updated to 2010 as start year – Prior to 1975, remaining life constant at 6.1 years Apply measure life to all 2009 JACO data to develop a weighted average 21

Measure Cost Current RTF assumed measure cost: $140/unit – $110 for implementation Pickup costs Recycling costs Data collection and tracking – $30 customer incentive Proposed updated measure cost (incremental): $90/unit – $90 for implementation Costs have come down (per JACO and Phil Sisson) – Remove the customer incentive from the RTF measure cost 22

Proposed Measures (Results) Proposed Measure Sunset: 2 years Decision? 23

Other Questions Utilities are starting programs to recycle appliances collected by New Appliance Dealers (not curb-side pickup). – Should these be handled as a separate deemed measure? – Net-to-Gross could be different for these types of programs. – NTG may be expected to be lower for retail-pickup programs than curb-side pickup programs since retailers often offer this service already – However, recent survey results in ComEd territory showed higher NTG (small sample size) – Proposal: Provisionally deem these with the same values. (no distinct measure) Evaluation suggested. Review in 2 years. (likely to have more data from national sources) Should Residential-style refrigerators from non-residential buildings be allowed? JACO reports some utilities allow these, but they’ve only come in in very small numbers. Proposal: Yes, allow them. 24