STAY SAFE!. ELECTRICAL FIRES ARE ALL TOO FREQUENT! -Homes over 40 years of age are at increased risk of fire. -The fire hazards are usually not recognized.

Slides:



Advertisements
Similar presentations
OSHA Region 1 Cooperative and State Programs Electrical Training/Inspection “Roll Up” Extension Cords GFCIs Power tools.
Advertisements

Introducing Electricity and Electrical Safety
Basic House Wiring.
Electrical Risks, Safety and Solutions for Older Homes
Electrical Risks, Safety and Solutions for Older Homes
Electrical Safety.
New Mexico FFA Agricultural Mechanics Career Development Event Electric Power.
Electrical Installation
Basic Electricity.
Electrical Safety Scenarios
Electrical Fire Safety Fire Prevention Week 2012 Electrical Safety Foundation International.
4/30/2015 AFCI 9/01/07 Rev 5 1 Arc Fault Circuit Interrupters For NEMA Field Reps.
Electrical Safety 29 CFR I. Background for the Trainer:
Inspecting Electrical. Inspection Includes:  Service entrance & masthead  Main panel and subpanels (if any)  Branch circuit wiring  Junction boxes,
Better Safe Than Sorry A WORLD THAT STARTS WITH ELECTRICAL HAZARDS AND SAFETY. ELECTRICITY IS A VERY SERIOUS BUSINESS AND THE EFFECTS ON THE HUMAN, ELECTRICAL.
Electrical Safety Month May is electrical safety month and is used to raise awareness of electrical safety issues that could cause harm to people and property.
EET Survey of Electronics
Electrical Power Systems
Residential Wiring Facts
Circuit Protection Electrical circuits require protection to prevent fire or electrocution in the event of a fault. There are two main types of circuit.
Noadswood Science, 2012 Electrical Safety. Electricity Safety To be able identify safety features with electrical components Tuesday, August 11, 2015.
Panels and Subpanels. Main Service Panel aka Load Center The Load Center is the heart and soul of a home’s electrical system. It: – Serves as a distribution.
The Home Inspection Book: A Guide for Professionals By Marcia Darvin Spada Copyright, Thomson/South-Western, 2003, Revised, 2006.
Purpose Power lines Equipment Assured Grounding GFCI Conclusion.
Area of Study 2: Electricity
Electrical Safety INSTRUCTOR’S NOTES:
Hazard Identification at Home. Ground Fault Circuit Interrupters (GFCI’s)  GFCI’s provide protection by turning off the power before a shock occurs 
ELECTRICAL HAZARDS Electricity is an essential of modern life Some work directly with electricity (Engineers, circuit assemblers) Some work indirectly.
Electrical Principles and Wiring Materials. Principles of Electricity n Electricity is a form of energy that can produce light, heat, magnetism, chemical.
Principles of Electricity Ampere The rate of flow of electricity.
Electric Circuits17.4. Electrical Safety Tips Make sure insulation on cords is not worn Do not overload circuits Do not use electrical devices while hands.
Home Electrical Wiring Types of Receptacles and Wiring them for 120v – 15Amp/20Amp.
Electrical Principles and Wiring Materials Unit #31.
Keeps heat indoors in winter and outdoors in summer – means lower heating and cooling bills Rated by it’s R-value. The greater the R- value the better.
The 13 Amp PLUG Fuse Insulating Casing Live Wire Neutral Cable grip Flexible Copper conductors Earth.
Electrical Safety and Electrical Safe Work Practices EHS Course #525 Reference EHS Electrical Safety Procedure
Electrical Principles and Wiring Materials
Electrical Principles and Wiring Materials Original Power Point Created by Casey Osksa Modified by Georgia Agricultural Education Curriculum Office June.
Electrical Safety in the Home 1.Circuit Breakers 2.Fuses 3.Wall Outlets 4.Circuit Breakers 5.GFCI/RCD.
ELECTRICAL FIRES CAN BE PREVENTED! By PowerCheck.
By: Mr. Brock.  Electricity- Source of energy that can be easily converted into light, heat or power  Ampere (Amp)- Unit of measure of the rate of flow.
Electrical Safety, Subpart K
Starting Residential Wiring.  The most important element in wiring. Safety is proper grounding.  Grounding is the connection of all parts of a wiring.
Topic: Electrical Circuits PSSA: B / S8.C.2.1.
Electricity. TYPES OF CIRCUITS Individual electrical circuits normally combine one or more resistance or load devices. The design of the automotive electrical.
Domestic Circuits – Learning Outcomes
Electrical Safety around the Home and farm Jesse Morris \ Spring 2002 Virginia Tech This presentation has not been edited by the Georgia Curriculum Office.
Electric Circuits Chapter 14, Section 4. Circuits consist of an energy source, a load, wires, and in some cases, a switch.
Chapter 2; Lesson 2.1 T.O.C: Charge Needs a Continuous Path to Flow.
Electrical Safety and Safe Work Practices
Unit 3 Lesson 3 Electric Circuits
4.0 DOMESTIC ELECTRICITY Domestic electricity is that electricity which is supplied to homes under specific conditions of current and voltage. Voltage,
Making Circuits Safe SNC1P1 Findlay.
Circuit Protection Unit 9.
Electrical Safety Describe and explain how a fuse works as safety device. Describe and explain how a circuit breaker works as a safety device. Explain.
Starter Review your filament lamp experiment and make corrections (in green pen) Review your test and complete the front cover sheet, correct any mistakes.
Circuits Electrical Wiring.
Energy Consumption: HOME.
Energy Consumption: HOME.
HOME ELECTRICAL SAFETY
Agricultural Systems Technology II
AFCI Protection: AFCI Receptacles and the NEC
Unit 3 Lesson 3 Electric Circuits
Domestic Electricity AIM: To understand the use of domestic electricity and safety features such as fuses, circuit breakers and the earth circuit
The Safe Use of Electricity
Conductor A material, such as copper, that permits the flow of electricity; usually refers to the a wire.
Energy Consumption: HOME.
Click anywhere to get started…
2019 ECR Presentation “HOT SKIN”
Presentation transcript:

STAY SAFE!

ELECTRICAL FIRES ARE ALL TOO FREQUENT! -Homes over 40 years of age are at increased risk of fire. -The fire hazards are usually not recognized by homeowner. -Identification of electrical fire hazards requires a comprehensive examination by qualified personnel.

FOUR AREAS OF THE HOUSE TO EXAMINE 1. Service 2. Panelboard(s) 3. Branch circuits 4. Connected loads Panelboard Branch circuits Electrical devices Service Connected loads

SERVICE PROBLEMS The service brings the power into the house Common problems are due to aging: Tree branches in contact with service conductors Service conductors abrading against newly installed metal gutters Deterioration of service conductors at side of house Service-conductor wire holder being detached from side of house The service grounding is often found to be broken

IN THIS WELL KEPT OLDER HOME…

SERVICE HAD SERIOUS FIRE HAZARD PRESENT, NOT RECOGNIZED BY THE HOMEOWNER On side of house electrical service wires have badly deteriorated Conductors could flash together at any time, creating fire.

IMMEDIATE ATTENTION WAS REQUESTED & HOUSE WAS MADE SAFE Within one hour homeowner had their electrician on site to begin repairs. A new service was required.

IN ANOTHER HOUSE: GROUND HAS BEEN BROKEN DUE TO A DETACHED CLAMP Service ground protects house from fire in the event of lightening, or electrical fault. This house is not protected. It is a 5 minute fix to make safe.

IN THIS HOUSE: GROUND WAS BROKEN DUE TO PLUMBING REPAIRS In is not uncommon to find repairs of the copper pipe done with “PEX” pipe. This breaks the electrical grounding, putting house at increased risk of fire A 5 minute fix to make safe.

IN THIS HOUSE: FUSES IN MAIN DISCONNECT WERE REPLACED WITH METAL BARS, PUTTING HOUSE AT RISK OF FIRE Handyman solved the problem by replacing main fuses with metal bars, creating a fire hazard in the process. Two illegal suites were added to the home. The main fuses would regularly blow as the service size was not sufficient. House was rated Extreme Risk. Metal bars

PANELBOARD PROBLEMS The panelboard is the protection system Problems with panelboards are abundant in older houses. Commonly found: Oversized circuit breakers Panelboard overloading (too many circuits) Add-on circuits hazardously installed Loose connections Panel openings resulting in build up of flammable debris in panel

IN THIS HOUSE, PANELBOARD WAS ILLEGALLY UPGRADED TO 200 AMPS, PUTTING HOUSE AT RISK OF FIRE 200 amp circuit breaker 60 amp wires Handyman installed a 200 amp panel without upgrading the service conductors. The wires overheat and the circuit breaker doesn’t trip. Believe it or not : In about 10% of houses we see, illegal service upgrades are present! House was rated Extreme Risk.

OVERSIZED BREAKERS: COMMON IN OLD HOUSES PUTTING HOUSE AT RISK OF FIRE If a circuit blows due to overloading, often homeowners will replace the breaker with a larger circuit breaker. This is a dangerous action as it defeats the function of the circuit breaker. Common with kitchen counter outlets. The correct repair is to provide an additional outlet circuit. 15 amp circuit breaker 30 amp circuit breaker

OBSOLETE BREAKERS ARE OFTEN FOUND PUTTING HOUSE AT RISK OF FIRE Older circuit breakers (pre mid- 1960s), such as, “Square D, Type XO” may not trip quickly when needed. Modern breakers, such as “Square D, Type QO” feature internal components to trip quickly. If these older circuit breakers are identified in homes, they should absolutely be replaced.

BRANCH CIRCUIT PROBLEMS Old houses typically did not have enough circuits to meet modern needs. Thus in old houses renovations, upgrades & additional circuits are sure to be present. If the renovations, upgrades and additional circuits have all been done by licensed contractors there should be no concerns. However the vast majority of older houses have some degree of illegal add-ons hazardously installed (aka. “Handyman add-ons”). These illegal add-ons can and do result in fires.

CONNECTIONS NOT IN BOXES If the connections become loose they will spark & create fire. In this home, a handyman added an outlet in the basement. Connections were twisted together and pinched behind the wooden moulding. Hazardous connections such as this are most common in old houses.

IN OLDER HOUSES FIRE HAZARDS ARE ABUNDANT These holes provide easy access for spiders and rodents seeking the warmth in an electrical box. Should sparks occur at the connections in the box, the debris can easily ignite. Sometimes boxes are full of debris. Holes can easily be sealed with metal caps. Open holes in boxes are common with handyman work

LAMP HOLDER HAZARDOUSLY INSTALLED Handyman failed to install a junction box behind this lampholder. Electrical connections can get loose over time. A junction box prevents sparks from loose connections from starting a fire.

IN OLD HOUSES HANDYMAN ADD-ON CIRCUITS ARE ABUNDANT An electrical box is required behind all outlets and switches, to prevent sparks from loose connections from starting a fire. This installer failed to install an electrical box behind this dryer outlet. To install a box is a 15 minute fix.

CABLES INSTALLED WITHOUT PROTECTION Where a metal cable meets the box a protective bushing (aka. Anti-short) is required to protect the sharp edge of the metal casing from cutting the wire. Installer failed to install an “Anti-short” on this cable to a new furnace, putting house at increased risk of fire” Anti-shorts take seconds to install.

HAZARDOUS BASEBOARD HEATER INSTALLATION Installer failed to install a “box connector” to protect cable from being cut on sharp edge of heater opening, putting house at increased risk of fire Installing a box connector to make it safe takes only minutes

INDOOR CABLES INSTALLED OUTDOORS DETERIORATE OVER TIME Old indoor cables installed outdoors have deteriorated, now taped with duct tape by occupant. House is now at increased risk of fire. These cables will need to be removed and replaced with new.

COMMONLY FOUND IN BASEMENTS: ELECTRICAL WIRES DANGLING AND LIVE! Often found in the basement near gas pipe, due to old electric water heater now replaced with gas. House at risk of fire. Live electrical wires found millimeters from gas pipe, could cause sparks Disconnecting the live cable from the panelboard takes only minutes

KNOB AND TUBE HAS CONCERNS Key concern: Knob-&-tube is not compatible with standard modern outlets.

KNOB AND TUBE HAS SOLUTIONS This is an excellent and safe solution; and relatively inexpensive. It can be made compatible by replacing the outlet with a GFCI, or providing GFCI protection at the panel.

ALUMINUM WIRE ALSO HAS CONCERNS Key concern: Aluminum wire is not compatible with standard modern outlets

ALUMINUM WIRING HAS SOLUTIONS In this example, the incorrect wire connectors were used, creating a Fire Hazard Condition Copper pigtailing is an excellent solution, if done correctly. It entails short pieces of copper wire from the aluminum wire to the outlet. Correct wire connectors are essential. Incorrect wire connector has resulted in burned out conductors

SOME TIDY-UPS DONE BY HOMEOWNERS CREATE SERIOUS FIRE HAZARDS Metal staples are commonly found securing extension cords and Christmas lights. Over time the metal staples can easily cut through the cord insulation resulting in sparks and fire.

SOME ACTIONS BY OCCUPANTS PUT HOUSE IN FIRE HAZARD CONDITION

A POWERCHECK EXAMINATION IS COMPREHENSIVE, IMPARTIAL AND NON- INVASIVE. IT TAKES APPROXIMATELY 90 MINUTES IN A TYPICAL OLDER HOME.

STAY SAFE For further information or to arrange an appointment CONTACT PowerCheck at , or