111 EMC CONFIDENTIAL—INTERNAL USE ONLY Mail Home Munira Manasawala NetWorker 7.3 TOI July 19, 2005
22 EMC CONFIDENTIAL—INTERNAL USE ONLY Agenda Overview Architecture Functional Description Immediate Mail Home Alerts Mail Home Events NSR Resource Modifications Notification Resource Modifications
33 EMC CONFIDENTIAL—INTERNAL USE ONLY Overview Targeted for EDM converted Premier customers Forwards critical alerts to Legato/EMC support via Assist in the transition of EDM customers to NetWorker Helps Legato support be more proactive and assist in identifying critical events Not available in evaluation mode
44 EMC CONFIDENTIAL—INTERNAL USE ONLY Architecture Uses existing event notification architecture Pre-configured notification resources monitor and critical events to customer support All mail home notifications are initially disabled and need to be manually enabled NW Application nsrd NetWorker Client/ Storage Node NetWorker Server RPC event sent to nsrd Mail Home
55 EMC CONFIDENTIAL—INTERNAL USE ONLY Functional Description Feature not enabled via Enterprise Enabler Requires a Mail Home enabler alerts are configured to be sent out immediately (Immediate Alerts) subject line –MH – NW –Company name truncated to 32 characters contents –Company name, Site-Id, Phone number, address –Description of event recipients –Legato/EMC support –Customer’s NetWorker administrator –Additional recipients specified by customer
66 EMC CONFIDENTIAL—INTERNAL USE ONLY Immediate Mail Home Alerts Alert created and ed when an event occurs. After sending the alert the notification for this event is disabled. –Avoid multiple alerts for same event Notification needs to be manually re-enabled –Customer must re-enable notification, or no further detection/notification can occur
77 EMC CONFIDENTIAL—INTERNAL USE ONLY Immediate Alert
88 EMC CONFIDENTIAL—INTERNAL USE ONLY Mail Home Events Resource file corruption Bootstrap backup failure Unsatisfied mount media request Backup device(s) that were automatically disabled Core NetWorker daemons not running (nsrindexd/nsrmmdbd)
99 EMC CONFIDENTIAL—INTERNAL USE ONLY NSR (Server) Resource Modifications Support address –Specifies customer support address for mail home s –Read-Write –Initially set to Site Id –Identifies the NetWorker server at customer sites –Required to enable mail home notifications –Read-Write
10 EMC CONFIDENTIAL—INTERNAL USE ONLY Notification Resource Modifications Mail Home –Identifies Mail Home Notifications –Read-Only, Hidden, Values Yes/No Enabled –Used to Enable/Disable Notifications –Read-Write, Values Yes/No Additional Recipients –Specifies additional recipients for Mail Home s –Read-Write Immediate –Not supported in this release –Read-Only, Hidden Mail Home Day –Not supported in this release –Read-Only, Hidden Pending Event Information –Not supported in this release –Read-Only, Hidden