Simulations of Light Collection Efficiency (JLab Hall C 12 GeV Kaon Aerogel Detector) Laura Rothgeb Nuclear Physics Group Catholic University of America.

Slides:



Advertisements
Similar presentations
Stefan Roesler SC-RP/CERN on behalf of the CERN-SLAC RP Collaboration
Advertisements

USE OF GEANT4 FOR LHCB RICH SIMULATION S. Easo, RAL, LHCB AND ITS RICH DETECTORS. TESTBEAM DATA FOR LHCB-RICH. OVERVIEW OF GEANT4 SIMULATION.
1 A DIRC for GlueX Paul Mueller Oak Ridge National Laboratory and Stefan Spanier University of Tennessee, Knoxville BaBar DIRC Collaboration for the GlueX.
1 Deep Sea Neutrino Telescope Detection Principle.
Reflectivity Measurements of Critical Materials for the LUX Dark Matter Experiment Theory My experiment was a cyclic process involving software, engineering,
SANE S pin A symmetries of the N ucleon E xperiment SEEN THROUGH THE EYES OF JOHN GERMAN MASTERS STUDENT FROM NORTH CAROLINA A&T STATE UNIVERSITY. JUNE.
Could CKOV1 become RICH? 1. Characteristics of Cherenkov light at low momenta (180 < p < 280 MeV/c) 2. Layout and characterization of the neutron beam.
Alternative Prototype Detector Design D. Reyna Argonne National Lab.
Mar 31, 2005Steve Kahn -- Ckov and Tof Detector Simulation 1 Ckov1, Ckov2, Tof2 MICE Pid Tele-Meeting Steve Kahn 31 March 2005.
Review of PID simulation & reconstruction in G4MICE Yordan Karadzhov Sofia university “St. Kliment Ohridski” Content : 1 TOF 2 Cerenkov.
In this event 240 eV electron is passing through the MICE Cerenkov detector.
The Tagger Microscope Richard Jones, University of Connecticut Hall D Tagger - Photon Beamline ReviewJan , 2005, Newport News presented by GlueX.
Study of optical properties of aerogel
Update on the Gas Ring Imaging Cherenkov (GRINCH) Detector for A 1 n using BigBite Todd Averett Department of Physics The College of William and Mary Williamsburg,
Special Issues on Neutrino Telescopy Apostolos G. Tsirigotis Hellenic Open University School of Science & Technology Particle and Astroparticle Physics.
1 Tianchi Zhao University of Washington Concept of an Active Absorber Calorimeter A Summary of LCRD 2006 Proposal A Calorimeter Based on Scintillator and.
Nathaniel Hlavin Catholic University of America APS April Meeting 2011, Anaheim, CA April 29,
The Design of a Detector for the Electron Relativistic Heavy Ion Collider Anders Ingo Kirleis 1, William Foreman 1, Elke-Caroline Aschenauer 2, and Matthew.
Central Neutron Detector March ’11 Update Central Neutron Detector March ’11 Update Daria Sokhan IPN Orsay CLAS 12 GeV Workshop Paris, France – 9 th March.
The HERMES Dual-Radiator Ring Imaging Cerenkov Detector N.Akopov et al., Nucl. Instrum. Meth. A479 (2002) 511 Shibata Lab 11R50047 Jennifer Newsham YSEP.
HYP03 Future Hypernuclear Program at Jlab Hall C Satoshi N. Nakamura Tohoku University 18 th Oct 2003, JLab.
Under the Direction of Dr. Tanja Horn 01 Conceptual Studies for the π 0 Hadronic Calorimeter project date 8/19/2011 Rob Macedo and Katya Gilbo Catholic.
A Reconstruction Algorithm for a RICH detector for CLAS12 Ahmed El Alaoui RICH Workchop, Jefferson Lab, newport News, VA November th 2011.
The Poor Man’s RICH Concept: A One-Dimensional Dual Radiator RICH
Particle Production in the MICE Beam Line Particle Accelerator Conference, May 2009, Vancouver, Canada Particle Production in the MICE Beam Line Jean-Sebastien.
Space Instrumentation. Definition How do we measure these particles? h p+p+ e-e- Device Signal Source.
1 Fast Timing via Cerenkov Radiation‏ Earle Wilson, Advisor: Hans Wenzel Fermilab CMS/ATLAS Fast Timing Simulation Meeting July 17,
WP2 meeting, Oct 2006, CPPM Claudine Colnard - NIKHEF Claudine Colnard, Ronald Bruijn, Eleonora Presani, Siemen Meester, Paul Kooijman (presented by Maarten.
Data acquisition techniques and development of testing equipment for the JLab Hall C 12 GeV kaon aerogel detector Nathaniel Hlavin, Mike Metz VSL Presentation.
Special Issues on Neutrino Telescopy Apostolos G. Tsirigotis Hellenic Open University School of Science & Technology Particle and Astroparticle Physics.
Optical performances of CKOV2 Gh. Grégoire 1. Optical elements in relation with beam properties 2. Comparison of optical geometries 4. Electron detection.
Nathaniel Hlavin Catholic University of America Mentor: Tanja Horn In collaboration with: CUA, FIU, SCU, MSU, JLab, and Yerevan Jefferson Lab, Newport.
EIC Detector – JLab – 04/June/2010 Cisbani / HERMES RICH 1 HERMES: Forward RICH Detector Evaristo Cisbani / INFN-Rome Sanità Group Most of the slides from.
Electromagnetic Calorimeter for the CLAS12 Forward Detector S. Stepanyan (JLAB) Collaborating institutions: Yerevan Physics Institute (Armenia) James Madison.
MiniBooNE Michel Sorel (Valencia U.) for the MiniBooNE Collaboration TAUP Conference September 2005 Zaragoza (Spain)
RICH SIMULATION USING GEANT4 S.EASO, RAL OBJECTIVES OF THE SIMULATION. CURRENT STATUS AND PLANS. INTEGRATION WITH LHCb SOFTWARE. SUMMARY.
Aerogel counter with a Fresnel lens
work for PID in Novosibirsk E.A.Kravchenko Budker INP, Novosibirsk.
NESTOR SIMULATION TOOLS AND METHODS Antonis Leisos Hellenic Open University Vlvnt Workhop.
Latifa Elouadrhiri Jefferson Lab Hall B 12 GeV Upgrade Drift Chamber Review Jefferson Lab March 6- 8, 2007 CLAS12 Drift Chambers Simulation and Event Reconstruction.
Dual Target Design for CLAS12 Omair Alam and Gerard Gilfoyle Department of Physics, University of Richmond Introduction One of the fundamental goals of.
Brief Overview of a new experiment for JLab Hall C Nathaniel Hlavin Stephen Rowe Catholic University of America Catholic University of America, Washington,
NP group meeting 14 June Tanja Horn, CUA Colloquium Group meeting, 14 June 2011.
RICH simulation for CLAS12 Contalbrigo Marco INFN Ferrara Luciano Pappalardo INFN Ferrara Hall B Central Detector Forward Detector M. Contalbrigo1 JLAB12.
RICH Simulation in LHCb LHC Detector Simulation Workshop S.Easo, RAL, On behalf of LHCb–RICH group.
Aerogel Cherenkov Counters for the ALICE Detector G. Paić Instituto de Ciencias Nucleares UNAM For the ALICE VHMPID group.
Radia Sia Syracuse Univ. 1 RICH 2004 Outline:  The CLEO-III RICH Detector  Physics Requirements  CLEO-III RICH at work… Performance of the CLEO-III.
RICH simulation for CLAS12 Contalbrigo Marco INFN Ferrara Luciano Pappalardo INFN Ferrara Hall B Central Detector Forward Detector M. Contalbrigo1JLAB12.
1 Melynda Brooks, “Understanding the Origin of the Nucleon Spin” Understanding the Origin of the Nucleon Spin Andi Klein, P-23, Melynda Brooks P-25, Pat.
17-19 Oct, 2007Geant4 Japan Oct, 2007Geant4 Japan Oct, 2007Geant4 Japan 2007 Geant4 Collaboration.
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
Photon Transport Monte Carlo September 27, 2004 Matthew Jones/Riei IshizikiPurdue University Overview Physical processes PMT and electronics response Some.
RICH studies for CLAS12 L. Pappalardo1 Contalbrigo Marco Luciano Pappalardo INFN Ferrara CLAS12 RICH Meeting – JLab 21/6/2011.
Aerogel detector revisited Sokolov Oleksiy, UNAM, progress report, 20 Sept 2006 E int = M – wall reflectivity є – PMT relative area Belle geometry (traditional):
Geant4 Simulation for KM3 Georgios Stavropoulos NESTOR Institute WP2 meeting, Paris December 2008.
Struttura del nucleone: TMD Il RICH e HD-Ice per CLAS12 Marco Mirazita (LNF)
FARICH status E.A.Kravchenko Budker INP, Novosibirsk, Russia.
Focal Plane Scanner Jie Pan * + for the scanner working group Laura Cobus*, Anna Micherdzinska* Jeff Martin*, Peiqing Wang + * University of Winnipeg /
PhD thesis: Simulation & Reconstruction for the PANDA Barrel DIRC Official name: Open charm analysis tools Supervisor: Prof. Klaus Peters Maria Patsyuk.
Focusing Aerogel RICH Optimization A.Yu.Barnyakov, M.Yu.Barnyakov, V.S.Bobrovnikov, A.R.Buzykaev, V.V.Gulevich, S.A.Kononov, E.A.Kravchenko, A.P.Onuchin.
SHMS Aerogel Detector Construction is complete
“Performance test of a lead glass
Focusing Aerogel RICH with SiPM Photodetectors
KM2A Electron Detector Optimization
Particle Identification in LHCb
RICH simulation for CLAS12
… continue with realistic particle
Scintillation Counter
RICH simulation for CLAS12
PbWO4 Cherenkov light contribution to Hamamatsu S8148 and Zinc Sulfide–Silicon avalanche photodiodes signals F. KOCAK, I. TAPAN Department of Physics,
Presentation transcript:

Simulations of Light Collection Efficiency (JLab Hall C 12 GeV Kaon Aerogel Detector) Laura Rothgeb Nuclear Physics Group Catholic University of America August 19, 2011

Generalized Parton Distributions (GPD, model of the momenta of quarks within particle) are used to understand the internal structure of nucleons. Using hard scattering meson electroproduction we can construct the GPD of the proton and find the form factor of the kaon. To construct GPDs these data must conform to the model of hard QCD scattering. Overview : Additional Flavor Degree of Freedom in K + Production

Kaon Aerogel Cherenkov Detector Detects kaon particles via Cherenkov radiation Uses Photomultiplier Tubes (PMTs) to collect the light and convert to electrical signal via the photoelectric effect Some design considerations Ideal refractive index of aerogel Optimum number/placement of PMTs Effect of light guides on light collection efficiency

SimCherenkov FORTRAN Monte Carlo simulation written to model the Kaon Aerogel Cherenkov Detector for Jefferson Lab to optimize conceptual design components Allows for multiple configurations including options for manipulating detector geometry, placement and sizes of PMTs, variety of reflective surfaces and refractive indices of aerogel Tracks photons emitted by the Cherenkov radiation in the simulated detector and relays the total number of photoelectrons produced based on the characteristics of the detector determined by the user

Experimental Setup Implements extension volume to study effect of a large, asymmetrical light guide μ γe-e- Aerogel Casing Light Diffusion Box Extension Volume PMT

Light Guide Simulations Wrote new loop configuration: EXTENSION Width, length and height of the extension box can be modified to simulate various light guide geometries Surface of extension box can be changed to compare effects of various reflective materials Aerogel Casing Light Diffusion Box PMT Extension Box Volume

Maximum: EXTENDW = 0cmExperimental Setup: EXTENDW = 11.6cm Efficiency: 23% EXTENDH = 11.6 EXTENDL = 11.6 μ γe-e-

Maximum: EXTENDH = 15cmExperimental Setup: EXTENDH = 11.6 Efficiency: 90% EXTENDW = 11.6 EXTENDL = 11.6

Maximum: EXTENDL = 12cmExperimental Setup: EXTENDL = 11.6cm Efficiency: 99% EXTENDH = 11.6 EXTENDW = 11.6

Efficiency: Photon Loss ~37% of the total photons are absorbed in the extension box Aerogel Initial Light Guide (0cm) Light Box (millipore) Extension Box (mylar) PMT Window Returns to Light Box Aerogel Light Box Extension Box PMT Window Returns to Light Box

Results Geometry of light guides have a drastic effect on the efficiency of Aerogel Cherenkov detectors: light is lost mainly due to increased surface area in which the photons are absorbed Decreased efficiency shown empirically with experimental set-up at JLab, confirms simulation results Next, implementing a model of the detector into a detailed GEANT4 Monte Carlo simulation