THE NEW STATIC VAR COMPENSATOR FOR SPS – COMMISSIONING RESULTS based on the CIRED2003 conference paper from K. Kahle, J. Pedersen (CERN) and T. Larsson,

Slides:



Advertisements
Similar presentations
“Power Factor” In Transmission System
Advertisements

ACTIVE POWER FILTER FOR POWER COMPENSATION
Harmonics and reactive power ABB Automation File: netzrück-2.ppt 1Dr. Eulitz Rev 1 This presentation gives a short explanation of harmonics.
QUALITY AND TECHNOLOGY
Proton Driver Magnet Power Supply System Cezary Jach BD/EE Support April 19, 2000.
Presented by: Bikram Choudhury Regd. No. : Department of Electrical And Electronics Engineering FACTS Devices For Smart Grid 2 July 2015.
© ABB Group August 7, 2015 | Slide 1 Variable Shunt Reactors Optimize Transmission Systems Dr. Claes Bengtsson, Global Product Manager, Reactors. PowerGen.
Power Converters and Power Quality Karsten KAHLE, CERN CAS Power Converters 2014, Baden (CH) 2.
ET2105 Electrical Power System Essentials
Example 1 A 9375 kVA, 13,800 kV, 60 Hz, two pole, Y-connected synchronous generator is delivering rated current at rated voltage and unity PF. Find the.
Flexible AC Transmission Systems: Placement, Control, and Interaction
Master in Advanced Power Electrical Engineering © Copyright 2005 Techno-economic aspects of power systems Ronnie Belmans Dirk Van Hertem Stijn Cole.
POWER FACTOR CORRECTION
PQSynergy TM 2011 Harmonic Assessment of PEA North1, Chiangmai’s Customers in North Industrial Estate Chotepong Pongsriwat. M.Eng(EE) Chief of Power.
Applied Harmonics Control of Harmonics
17.March Connection to the CERN Power System of the TT2 mercury target project by Karsten KAHLE (TS-EL)
17-1 Copyright © 2003 by John Wiley & Sons, Inc. Chapter 17 Electric Utility Applications Chapter 17 Electric Utility Applications These applications are.
THYRISTOR BASED FACTS CONTROLLER
Series and Shunt Compensation
POWER QUALITY.
23/04/2017 TITRE PRESENTATION 1.
Institute of Power Electronics 1 Comparison of Series Hybrid Active Power Filters in Medium Power Application Comparison of Series Hybrid Active.
SMART SENSORS FOR A SMARTER GRID BY KAILASH.K AND LAKSHMI NARAYAN.N.
Review of the Project for the Consolidation and Upgrade of the CERN Electrical Distribution System October 24-26, 2012 THE HIGH-VOLTAGE NETWORK OF CERN.
Trieste (IT), 20 may 2008POPCA A novel 60 MW Pulsed Power System based on Capacitive Energy Storage for CERN PS machine Jean-Paul BURNET CERN, European.
Page 1J. Hourtoule, Electricity contract: scope and forecasted consumption, 16/07/2015 © ITER Organization Electricity Supply Contract: For the ITER Site.
Clemson University Electric Power Research Association CHANDANA BOMMAREDDY CLEMSON UNIVERSITY DG VOLTAGE CONTROL IN AN ISLANDING MODE OF OPERATION.
Harmonic Analysis of a DFIG for a Wind Energy Conversion System Lingling Fan, Ph.D., P.E. Assistant Professor Dept. Electrical Engineering University of.
Major power converter issues for the restart of PS & SPS machines and their experimental areas in 2006 Jean-Paul BURNET for AB/PO PS&SPS days January.
Daudi Mushamalirwa Luanda June, 2014 Technical issues of the stability of small size electric systems composed of wind generators and conventional generating.
Synchronous Voltage Reversal control of TCSC – impact on SSR conditions Hailian Xie Lennart Ängquist EME/ETS, Royal Institute of Technology, Stockholm.
Electromagnetic Compatibility Test for CMS Experiment. Authors C. Rivetta– Fermilab F. Arteche, F. Szoncso, - CERN.
A Trust Based Distributed Kalman Filtering Approach for Mode Estimation in Power Systems Tao Jiang, Ion Matei and John S. Baras Institute for Systems Research.
Jean-Paul BURNET, AB/PO ATC-ABOC days, 22 January 2007 PS Main Power System: What has been done from June 2006? What will be the situation in 2007? PS.
Optimal Power Flow- Basic Requirements For Real Life.
J. Pedersen, ST/EL Consolidation of the CERN technical infrastructure and civil engineering. J. Pedersen ST 6 th ST workshop, Thoiry, 1 – 3 April 2003.
Power Quality Karsten KAHLE Electric Power Converter Group (TE-EPC) High Power Converter Section Review of CERN’s Electrical Power Network October.
A common 400 Hz AC Power Supply Distribution System for CMS FEE. Authors C. Rivetta– Fermilab. F. Arteche, F. Szoncso, - CERN.
Static Var Compensator Status (SVCs for Booster and SPS) Situation in 2009 Karsten KAHLE, TE-EPC ATOP days March 2009.
ABOC/ATC days Electrical Network: Selectivity and Protection Plan José Carlos GASCON TS–EL Group 22 January 2007.
LARSSON SE Session 2 – Block 2 Barcelona May The new 150 Mvar, 18 kV SVC at CERN – background, design and commissioning K. Kahle, J Pedersen,
A second Thyristor Controlled Static Var Compensator for SPS
Virtual Resistance Line conditioner Block Diagram:
POWER QUALITY AND NETWORK DISTURBANCES in CERN’s electrical network K. KAHLE, TS-EL Diploma students R. Sternberger, M. Neubert 1 st TS Workshop Archamps,
TECHNICAL PAPER ON SIMULTANEOUS AC-DC POWER TRANSMISSION
Carlos A. Martins ESS – Accelerator Division - RF Electrical Power Systems June 2 th, 2014 Design, construction and measurement.
New prototype modulator for the European XFEL Project (DESY) Pulse Step Modulator (PSM) Technology for long pulse applications.
POPS: Power for PS A novel 60 MW Pulsed Power System based on Capacitive Energy Storage Jean-Paul Burnet June 2010.
RECENT TRENDS IN POWER SYSTEMS
HP-PS beam acceleration and machine circumference A.LachaizeLAGUNA-LBNO General meeting Paris 18/09/13 On behalf of HP-PS design team.
A DSP based on on-line UPS R.Padamaja G.Mamatha Reddy EEE EEE S.V.C.E S.V.C.E BY.
J.PRAKASH.  The term power quality means different things to different people.  Power quality is the interaction of electronic equipment within the.
Power Quality Issues Power Electronics Group.
 The common type of wind power generators are squirrel cage induction generator (SCIG),doubly fed induction generator (DFIG)  For more secure and.
Harmonic Issues of AEP Welsh HVDC System Bob Malek Kiril Andov Richard Gutman Ben Mehraban 10/12/2015.
Effects of Harmonics on Capacitors Electrical System
Situation of the Static Var Compensators at CERN.
CHAPTER 6 SPECIAL TRANSFORMERS Electrical Machines.
FACTS BY SVC, FLEXIBLE AC TRANSMISSION
SIMULATION AND IMPLEMENTATION OF FC-TCR
Presented By Deepak Kumar Bari Regd. No
M.KARTHIK (10F41D4307) Under the esteemed guidance of
SPS activities during LS2 TE-EPC (Power Converter Group)
Transmission Solutions
UNIFIED POWER QUALITY CONDITIONER
ECEN 460 Power System Operation and Control
Connecting the London underground to the public grid: solutions for safeguarding of power quality R Grünbaum, M Noroozian, A Palesjö, ABB Presented by.
SHUNT ACTIVE FILTER It is a voltage-source converter connected in shunt with the same ac line and acts as a current source to cancel current distortions,
I Alexander Nass for the JEDI collaboration
FACTS BY SVC, FLEXIBLE AC TRANSMISSION
Presentation transcript:

THE NEW STATIC VAR COMPENSATOR FOR SPS – COMMISSIONING RESULTS based on the CIRED2003 conference paper from K. Kahle, J. Pedersen (CERN) and T. Larsson, M. M. Oliveira (ABB) CERN - European Organization for Nuclear Research K. Kahle April 20036th ST Workshop, THOIRY Design The new Static Var Compensator for the SPS, CERN Prevessin Background Calculations before installation Measurements after installation Calculated harmonics performance The SVC is an outdoor installation covering an area of about 2500 m 2. It also includes a prefabricated building for the high voltage thyristor valves, the cooling system and the SVC control system. The remaining space is used for the harmonic filters. The SVC consists of a TCR rated at 150 Mvar and eight harmonic filters tuned to 100, 150, 250, 350, 550, 650 Hz and two damped high-pass filters. The filters generate a total reactive power of 130 Mvar. Measured harmonic performance Measured 18 kV bus voltage Measured load current during a SPS pulse Results of 18 kV voltage calculations: The EMTDC computer simulations modeled the behavior of the SPS power converters, of the Static Var Compensator and of the interaction between them. The main purpose of the Static Var Compensator is to stabilize the 18 kV voltage, therefore the resulting 18 kV network voltage was calculated for a complete SPS pulse. Small variations of the 18 kV voltage were expected at the transition points from the rising slope of the power pulse to the flat top and from the flat top to the pulse descent. Results of 18 kV harmonic measurements:  Total Harmonic Distortion 0.74 %  no individual harmonic exceeding 0.5 % The measurements correspond closely to the calculated values. Results of 18 kV voltage measurements: The voltage response was recorded and the data post-processed with MATLAB. The comparison of the calculated 18 kV voltage with the measured response shows large similarities. All voltage notches, both up and down, are identical. Only the first notch at t=9 s of the measurement is critical, while the second, larger variation at t=10.5 s has no major significance for the physics performance of the SPS accelerator. Some discrepancies were found in the amplitude of the notches, where the measurements show larger voltage variations than the calculations predicted. Here the computer model needs to be improved in the future. Conclusions Following a long history of SVC projects at CERN since 1974, the new 150 Mvar 18 kV Static Var Compensator was successfully installed and tested in During the project there was a unique opportunity to compare and verify comprehensive computer studies with the results of extensive measurements. Following the actual performance tests, the correct operation of the SVC, together with the SPS accelerator, was successfully proven over a period of several months. This project also shows the excellent SVC performance, which can be achieved for fast changing rectifier loads, by using conventional TCR technology, combined with passive filtering. Computer calculations: a) active and reactive power b) resulting 18 kV voltage c) TCR susceptance reference d) TCR firing angle e) reactive power from 400 kV network The The SPS electrical network currently consists of: 3 transformers 400/18 kV 3 Static Var Compensators (1974, 1976 and 2002) 2 main groups of SPS power converters The new Static Var Compensator (SVC) was required: to have a third redundant supply group (3 transformers and 3 SVC’s) to facilitate the renovation of the two existing Static Var Compensators to cover the load increase due to the LHC injection tunnels TI2 / TI8. Purpose of the Static Var Compensator (SVC): The electrical current in the SPS magnet is pulsating between zero Ampere and 4500 Ampere every 14 seconds. A Static Var Compensator: compensates for the reactive power stabilizes the 18 kV voltage (variation: 14% without SVC, 0.75 % with SVC) eliminates the harmonics created by the pulsating load (harmonic distortion: 20% without SVC, 0.74 % with SVC) Results of 18 kV harmonic calculations:  Total Harmonic Distortion < 0.8 %  no individual harmonic exceeding 0.35 % The studies confirmed that eight harmonic filters were needed to achieve the required excellent performance. Existing SVC BEQ1Existing SVC BEQ3 New SVC BEQ2 SPS Impedance diagram Simplified layout of the SPS electrical network Layout of the SVC