Make the most of your energy December 2008 HDM Accurate measurement and electrical utility cost allocation for multi-tenants PowerLogic ® High Density.

Slides:



Advertisements
Similar presentations
Installation base of over 25,000 valued installations, Country wide Installation base of over 25,000 valued installations, Country wide Recognised as.
Advertisements

What we do Larotecs Web2M is an off-the shelf, end-to-end, web-based solution designed to manage multiple widely distributed devices.
Emergency Transfer Controls
NEMA. 2 Utility Metering vs. Submetering 10/11/2014 New PowerPoint Template Utility Meter Meter provided by utility with the purpose of measuring.
Introduction Build and impact metric data provided by the SGIG recipients convey the type and extent of technology deployment, as well as its effect on.
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
Total HVAC Control from anywhere Easy control that can save a fortune
Multi Functional Digital Fault Recorder
MIFII DIGITAL FEEDER PROTECTION A Cost Effective Protection Solution for Overcurrent Protection at Any Voltage Level GE Multilin
BFM136 Branch Feeder Monitor April SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.
Feeder and Main Application
PowerLogic® Factory Assembled Enclosures
KW Energy Solutions, LLC Increasing Energy Efficiency Increasing Energy Effectiveness.
What is Energy Monitoring?. Market Direction The lighting control industry being driven to manage energy holistically and to show ROI – Energy costs are.
E-Mon Energy™ Energy Monitoring Software
Make the most of your energy Looking for accurate electric energy metering and simple, easy installation? PowerLogic ® Energy Meter December 2008 Energy.
TECHNOLOGIES AUTOMATED METERING. Proprietary Information Of Energy 2013 MACDILL AFB METERING DOD Implementation Guidance – MAJCOM Energy Mangers shall.
Simple, accurate tenant sub-metering
1. 2 Jamie Caplan Square D by Schneider Electric Energy Solutions – Northwest Tel:
Utility Monitoring System Overview AH&MA Annual Conference & Leadership Forum April 5, 2001 Chicago, IL Brian Burke, CEM Energy Manager.
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
GE Consumer & Industrial Multilin PMCS Energy Management Systems Vincent Thomas.
Make the most of your energy Make the most of your energy SM Add application photo in this area PowerLogic ® Branch Circuit Power Meter for data center.
Make the most of your energy December 2008 PowerLogic Enercept Submetering ….when space is at a premium PowerLogic® Enercept Meter.
Technology I Sub-Metering 101. Proprietary Information Of Energy 2013 Submetering 101 What Federal Facility Managers Need To Know Presented by Steve Kearney.
PowerLogic® Submetering
MIG II DIGITAL FEEDER PROTECTION
ICONICS Worldwide Customer Summit - © 2013 Reduce Energy and Save Money with Energy AnalytiX Milesh Patel, Solutions Architect, UK Ioannis Apostolakis,
Make the most of your energy June 2008 Power Meter 800 PowerLogic ® Power Meter 8ECC.
1 Department of Water and Power City of Los Angeles Automatic Meter Infrastructure Program Mariko Marianes and John Yu.
Today’s Enterprise Energy Management Systems: What to look for…. Mark A. Noyes CEO and President Cambridge, Massachusetts.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
PowerLogic® E5600 power and energy meter 1.
G650 Generator Protection & Control System
1 © Red Lion Controls Inc. Introducing the RAM 9000.
Looking for a more powerful circuit monitor?
October 27, 2011 CONFIDENTIAL © 2011 Better Place CPUC Submetering Workshop EVSP Coalition Recommendations.
SMART METERING SOLUTIONS TO SHAPE OUR ENERGY FUTURE Empowering the Customer Experience Marketing Executives Conference Cranwell Resort Lenox, Massachusetts.
Make the most of your energy Make the most of your energy SM Add application photo in this area Need an easy to use, modular system for revenue metering?
Make the most of your energy December 2008 Advanced Reports Control the cost, reliability and quality of your electric power PowerLogic ® System Manager.
Need to enhance your network?
New IQ300 IQ Data & IQ Generator Replacement. Current Product  IQ Data Measures  Phase Currents  Voltage L-L, L-N  IQ Generator adds  Frequency measurement.
April 2011 November 2010.
1 Monitor System Reliability alarm on demand, sag/surge, and etc. Perform Advanced Power Quality Analysis provide real-time trending. Centralized.
Make the most of your energy December 2008 PM8ECC Need improved Network capabilities out of your meter? PowerLogic ® PM8ECC.
KNX – the benefits. Schneider Electric 2 - IS&C – Aug Content ●Basic arguments ●Added value for: ●Investors ●Wholesalers ●Installers and System.
PowerLogic® PowerView Software
IQ Analyzer 6400/6600 Series Cutler-Hammer Power Management Products High End Metering Capabilities.
Consumer Education Challenge 1000 kwh x rate/kwh = $ Billed Amount When asked about energy usage, the customer receives this…… But really understands this…………
Make the most of your energy December 2008 Multi-Circuit Meter Need to monitor multiple electrical services, which share a common voltage source? PowerLogic.
PowerLogic PowerView v2.0 software
© 2011 QLC Submetering: Evolution, Technologies, Applications.
Energy Family Power Meter Energy Energy Plus & Energy Pro.
1 Powerware kVA The modular, scalable, redundant UPS for midrange applications.
LEADING THE PACK.
EasyLogic PM2000 series The easy choice for quality, value, and simplicity. Customer overview.
DIGITAL MULTIMETER DMG
Avaya VA Line-interactive UPS
De-Ice control devices
Integrated gateway-server
PowerLogic™ offer for the basic metering market
Introduction to the POWERLOGIC® PM700 Series Power Meters
PowerLogic PM5350 High-performance multifunction power meter
Smart Prepayment Solutions for PV/SSEG
PM9, PM9P and PM9C Power Meter
Meet demanding customer expectations with the right energy meter
PowerLogic ION6200 Power and energy meter.
Simple, accurate tenant sub-metering
Power monitoring software
Presentation transcript:

Make the most of your energy December 2008 HDM Accurate measurement and electrical utility cost allocation for multi-tenants PowerLogic ® High Density Metering Enclosures

Schneider Electric 2 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering overview ●PowerLogic® High Density Metering (HDM) products are pre-wired, multi or single meter cabinets that offer a high quality, cost effective solution for submetering/billing, monitoring energy usage or energy cost allocation. ●They are ideal for new and retrofit construction in commercial, residential and industrial facilities and are easy to specify, purchase and install. ●PowerLogic HDM cabinets are available in multiple configurations and can be equipped with a choice of ANSI certified and reliable PowerLogic meters.

Schneider Electric 3 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering overview – cont. ●PowerLogic HDM cabinets are available in 1-meter, 4-meter, 8-meter and 16-meter configurations. ●Type 1 (indoor) – available with 1, 4, 8, & 16 meters ●Type 3R (outdoor) available with 1 & 4-meter enclosures ●A variety of PowerLogic meters are available: 1 & 4-meter 8 & 16-meter ●Optional Modbus TCP/IP when ordered with integrated EGX (8 and 16- meter enclosures). ●Designed for use with a variety of PowerLogic software, including: Tenant Metering software, Tenant Metering Commercial Edition software, SMS or ION Enterprise®.

Schneider Electric 4 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering applications ●Tenant Sub-metering – Accurately bill tenants for their energy usage. ●Benefit – Data can be used to offer reduced lease rates ●Energy cost allocation – Allocate facility energy costs based on actual usage by department, tenant and cost center. ●Benefit – Identify energy conservation measures that won’t heavily impact people or processes ●Demand Control – Discover your facility’s electricity usage patterns, total period energy consumption and peak demand. ●Benefit – Use the data to establish a baseline and reduce demand charges and lower long-term energy costs

Schneider Electric 5 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering customers ●PowerLogic HDM cabinets are ideal for organizations such as government, educational, transportation, property management and entertainment or leisure venues that want to improve energy efficiency and allocate costs or bill tenants within their facilities: Suitable building types include, but are not limited to: ●Office buildings ●Malls and retail operations ●Universities and colleges ●Government facilities ●Multi-use commercial and residential ●Hotels and entertainment venues ●Airports and other transportation facilities

Schneider Electric 6 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering benefits ●Outstanding quality, equipped with full-featured meters with easy to read displays and intuative interfaces ●Cabinets are pre-wired, for easy mounting and installation in new and retrofit applications ●Installation keyholes simplify mounting for 1 and 4 meter enclosures while mounting channels and surface mount flanges enable easy installation for 8 and 16-meter HDM ●Space saving design offers a small footprint for mounting next to an existing panelboard ●Add additional meters to empty slots as your needs change ●Industry standard Modbus communication and available Ethernet

Schneider Electric 7 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering general features ●All configurations ●Extensive voltage input options: ●120/240 volt single phase ●120/208 and 240 volt three phase ●480 volt three phase ●600 volt three phase (4-meter) ●Rugged, lockable steel cabinets provide tamper-resistant security ●Factory-installed shorting block(s) ●Standard RS485 Modbus® communications or available Ethernet Modbus® TCP/IP (not available on 1-meter HDM ●Utilizes 5A CTs (not included with enclosure). Shorting Blocks EGX mounting space Factory installed wiring harnesses UL489 CB

Schneider Electric 8 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering 1-meter HDM features ●Versatile 1-meter HDM is available in Type 1 (indoor) or Type 3R (outdoor) ●Can be equipped with high quality PowerLogic PM210, PM750 or ION6200 meters. ●Comes with the meter you choose pre-installed and wired ●Energy and power accuracy ●PM210 = ANSI C Accuracy Class ●PM750 = ANSI C Accuracy Class ●ION6200 = ANSI C Accuracy Class

Schneider Electric 9 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering 1-meter HDM dimensions

Schneider Electric 10 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering 4-meter HDM features ●4-meter HDM is available in Type 1 (indoor) or Type 3R (outdoor), requires minimal wall space ●Comes with the meter you choose pre-installed and wired for field termination ●Voltage disconnect for phase voltages & auxiliary control power ●Energy and power accuracy ●PM210 = ANSI C Accuracy Class ●PM750 = ANSI C Accuracy Class ●ION6200 = ANSI C Accuracy Class ●Utilizes 5A CTs ●Standard RS485 Modbus®

Schneider Electric 11 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering 4-meter HDM dimensions

Schneider Electric 12 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering 8 and 16-HDM features ●Standard power meters mounted in a Type 1 enclosure ●Factory-installed wiring harness for each row of meters ●The panel is prewired to terminal block for easy field connections ●Integral power circuit protection (UL489) on 8 and 16-meter enclosures ●Energy and power accuracy ●PM210 = ANSI C Accuracy Class ●PM750 = ANSI C Accuracy Class ●Utilizes 5A CTs ●Standard RS485 Modbus® or optional Modbus TCP/IP

Schneider Electric 13 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering 8 and 16-meter HDM dimensions 8-meter cabinet 16-meter cabinet

Schneider Electric 14 - Marketing – HDM – December 2008 PowerLogic ® High Density Metering Cabinets meter selections ●Meter selections for all cabinets: ●PowerLogic® PM210 Entry-level meter, ideal for single phase or three-phase applications ●PowerLogic® PM750 Full-featured, high accuracy device with I/O, THD, min/max & more ●Additional meter option for 1 and 4-meter cabinets ●PowerLogic® ION6200 Exclusively for 600 volt for applications, it offers an LED display, and extended operating temperature range for outdoor applications PM210 PM750 ION6200

Schneider Electric 15 - Marketing – HDM – December 2008 PowerLogic® High Density Metering Cabinets meter comparison chart FeaturesPM210PM750ION6200 Energy and power accuracyANSI C ANSI C Instantaneous RMS values Current, Voltage, Frequency Power Real, Reactive, Apparent, PF total Energy values Active, reactive, apparent energy Demand Current, power (active, reactive, apparent) Power quality measurements Harmonic distortion (current, voltage)– Data recording Min/max of instantaneous values– – Display and I/O Backlit LCD display LED Display Pulse output–12 Pulse input–2– Communication RS485 port with Modbus protocol Alarms –

Schneider Electric 16 - Marketing – HDM – December 2008 Software for a Total Solution: PowerLogic ® billing software ●Two cost effective, easy-to-use software options to choose from ●Common benefits include: ●Automatically collect meter data ●Support electricity, gas and water meters ●Generate customized tenant billing and account statements

Schneider Electric 17 - Marketing – HDM – December 2008 Software for a Total Solution: PowerLogic ® billing software ●Two cost effective, easy-to-use software options to choose from ●Common benefits include: ●Automatically collect meter data ●Support electricity, gas and water meters ●Generate customized tenant billing and account statements ●PowerLogic Tenant Metering – Commercial Edition ●Billing based on interval data ●Real & reactive energy ●Flat & tiered rates ●Demand & power factor ●Seasonal rates ●Time of Use ●Miscellaneous charges ●PowerLogic Tenant Metering ●Real energy ●Flat & tiered rate ●Billing based on total consumption (kWh)

Schneider Electric 18 - Marketing – HDM – December 2008 Software for a Total Solution PowerLogic ® Tenant Metering software ●Low-cost, easy-to-use ●Automatically collects meter data ●Support electricity meters (real energy) ●Generate customized tenant billing and account statements or use the Export Tool for data integration with third party billing services

Schneider Electric 19 - Marketing – HDM – December 2008 PowerLogic® Tenant Metering Commercial Edition ●TMSCE is built on a utility-grade billing engine and offers more functionality and flexibility for demanding billing applications ●Invoicing based on consumption, TOU (Time Of Use), seasons, demand, & PF ●WAGES support ●Ability to allocate meters across tenants ●Ability to assign multiple meters to a single tenant ●Virtual meter support ●Customizable billing cycles ●Load profile reporting