High Dynamic Range Beam Imaging with a Digital Optical Mask* Presented by Tim Koeth (UMD) on behalf of R.B. Fiorito, H.D. Zhang, A. Shkvarunets UMD, College.

Slides:



Advertisements
Similar presentations
An Image Filtering Technique for SPIDER Visible Tomography N. Fonnesu M. Agostini, M. Brombin, R.Pasqualotto, G.Serianni 3rd PhD Event- York- 24th-26th.
Advertisements

Observation of beam halo with corona graph
Lecture 11. Microscopy. Optical or light microscopy involves passing visible light transmitted through or reflected from the sample through a single or.
C. Beichman, Dimitra Touli, Gautam Vasisht, Roger Smith Tom Greene
Halo, SLAC, 2014 Towards wire scanner measurements with Large Dynamic Range (> 10 6 ) Pavel Evtushenko, Jefferson Lab.
R Scrivens, CERN, ABI Workshop, 12/2008 The Feschenko Bunch Shape Monitor User experience at CERN Developed by INR, Troitsk. High resolution bunch shape.
Bunch shape monitor for Linac-4 A.V.Feschenko Institute For Nuclear Research (INR), Moscow , Russia.
Chris Tennant Jefferson Laboratory March 15, 2013 “Workshop to Explore Physics Opportunities with Intense, Polarized Electron Beams up to 300 MeV”
Ultrafast XUV Coherent Diffractive Imaging Xunyou GE, CEA Saclay Director : Hamed Merdji.
Optical Diagnostics Hg_jet_meeting, Thomas Tsang tight environment high radiation area non-serviceable area passive components optics only, no.
Optical Diagnostics Thomas Tsang tight environment high radiation area non-serviceable area passive components optics only, no active electronics back.
Generation and Characterization of Magnetized Bunched Electron Beam from DC Photogun for MEIC Cooler Laboratory Directed Research and Development (LDRD)
Beam Diagnostics Collaboration Meeting March 18 th 2015 at Australian Synchrotron Mario Ferianis – Elettra.
1 Welcome to the 2014 Beam-Halo Monitoring Workshop SLAC 2014 September 19 Alan Fisher SLAC National Accelerator Laboratory.
Recent Progress in X-ray Emittance Diagnostics at SPring-8 S. Takano, M. Masaki, and H. Sumitomo * JASRI/SPring-8, Hyogo, Japan SES, Hyogo, Japan *
Accelerator and Detector R&D, August Diagnostics Related to the Unwanted Beam Pavel Evtushenko, Jlab FEL.
BROOKHAVEN SCIENCE ASSOCIATES BIW ’ 06 Lepton Beam Emittance Instrumentation Igor Pinayev National Synchrotron Light Source BNL, Upton, NY.
Optical diagnostics for beam halo (I) Coronagraph (II) OTR halo monitor for J-PARC T. Mitsuhashi, KEK.
S. De Santis “Measurement of the Beam Longitudinal Profile in a Storage Ring by Non-Linear Laser Mixing” - BIW 2004 May, 5th Measurement of the Beam Longitudinal.
05/05/2004Cyrille Thomas DIAMOND Storage Ring Optical and X-ray Diagnostics.
Transverse Profiling of an Intense FEL X-Ray Beam Using a Probe Electron Beam Patrick Krejcik SLAC National Accelerator Laboratory.
Transverse beam size measurement High energy micron electron beam non-invasive diagnostics based on diffraction radiation G.Naumenko*, A.Potylitsyn, L.Sukhikh.
C. Fischer – LHC Instrumentation Review – 19-20/11/2001 Gas Monitors for Transverse Distribution Studies in the LHC LHC Instrumentation Review Workshop.
G5 Beam Instrumentation D. Gassner, E. Pozdeyev 4-09.
Multi-colour sctintillator-based ion beam profiler James Green, Oliver Ettlinger, David Neely (CLF / STFC) 2 nd Ion diagnostic workshop June 7-8 th.
Tests of spectrometer screens Introduction Layout Procedure Results Conclusions L. Deacon, B. Biskup, S. Mazzoni, M.Wing et. al. AWAKE collaboration meeting,
Compact X-ray & Emittance Measurement by Laser Compton Scattering Zhi Zhao Jan. 31, 2014.
G. Ferioli, R. Jung - LHC-BI Review Workshop November 19&20 LHC Screen Profile Monitors G. Ferioli, R. Jung Introduction BTV LHC layout Monitor set-up.
Abel Blazevic GSI Plasma Physics/TU Darmstadt June 8, 2004 Energy loss of heavy ions in dense plasma Goal: To understand the interaction of heavy ions.
Christoph Gabor, ASTeC HIPPI—Meeting (WP 5) 26 th – 28 th September 2007 Non—destructive transverse emittance measurement device The Front End Test Stand.
Beam/ Halo Diagnostics R. Fiorito, A. Shkvarunets, H. Zhang Institute for Research in Electronics and Applied Physics University of Maryland Presented.
M. Hosaka a, M. Katoh b, C. Szwaj c, H. Zen b M. Adachi b, S. Bielawski c, C. Evain c M. Le Parquier c, Y. Takashima a,Y. Tanikawa b Y. Taira b, N. Yamamoto.
Y. Roblin, D. Douglas, F. Hannon, A. Hofler, G. Krafft, C. Tennant EXPERIMENTAL STUDIES OF OPTICS SCHEMES AT CEBAF FOR SUPPRESSION OF COHERENT SYNCHROTRON.
Beam Halo Monitoring using Optical Diagnostics Hao Zhang University of Maryland/University of Liverpool/Cockcroft Institute.
NON-INTERCEPTING DIAGNOSTIC FOR HIGH BRIGHTNESS ELECTRON BEAMS USING OPTICAL DIFFRACTION RADIATION INTERFERENCE (ODRI) A. Cianchi #1,2, M. Castellano 3,
Beam dynamics in IDsBeam-based Diagnostics, USPAS, June 23-27, 2003, J. Safranek Beam Size Measurement m Survey of beam size measurement techniques and.
Taikan SUEHARA et al., LCWS2007 & DESY, 2007/06/01 R&D Status of ATF2 IP Beam Size Monitor (Shintake Monitor) Taikan SUEHARA, H.Yoda, M.Oroku,
SL/BI 16/05/1999DIPAC’99 -- JJ Gras -- CERN SL/BI -- Adaptive Optics for the LEP 2 SR Monitors G. Burtin, R.J. Colchester, G. Ferioli, J.J. Gras, R. Jung,
Awake electron beam requirements ParameterBaseline Phase 2Range to check Beam Energy16 MeV MeV Energy spread (  ) 0.5 %< 0.5 % ? Bunch Length (
Measurements of Intense Proton Beams using Optical Transition Radiation Vic Scarpine, Fermilab TIPP 2011 Chicago, IL June 10, 2011.
Adaptive Optical Masking Method and Its Application to Beam Halo Imaging Ralph Fiorito H. Zhang, A. Shkvarunets, I. Haber, S. Bernal, R. Kishek, P. O’Shea.
LARP Additions to the LHC Synchrotron-Light Monitors Alan Fisher SLAC National Accelerator Laboratory LARP CM18 Fermilab 2012 May 8.
Will Stem Resonant Excitation of Envelope Modes as an Emittance Diagnostic in High-Intensity Circular Accelerators.
What did we learn from TTF1 FEL? P. Castro (DESY).
Wir schaffen Wissen – heute für morgen PSI, March 2013 Paul Scherrer Institut PSI / DESY / KIT Mini-Workshop on Longitudinal Diagnostics for FELs.
Nonlinear Dynamics with Space-Charge in a Small Electron Recirculator Santiago Bernal on behalf of UMER group, IREAP, University of Maryland, College Park,
Optical Diagnostics State of the art and Future Trends Prof. Carsten P. Welsch.
ESLS Workshop Nov 2015 MAX IV 3 GeV Ring Commissioning Pedro F. Tavares & Åke Andersson, on behalf of the whole MAX IV team.
G. Trad on the behalf of the BSRT team Emittance meeting 04/11/2015.
Astronomical Spectroscopic Techniques
Emittance measurements for LI2FE electron beams
Date of download: 10/20/2017 Copyright © ASME. All rights reserved.
Gas jet based diagnostics for beam monitoring
E-beam scanner experience at FNAL
Analysis of optical IPM data
Summary of experience with Tevatron synchrotron light diagnostics
AVA Liverpool Carsten Welsch.
Lebanese Teacher Programme 18/04/2017
OTR based measurements for ELI-NP Gamma Beam Source
UCLA/ATF chicane compression experiments
Time-Resolved Images of Coherent Synchrotron Radiation Effects
Profile measurements at CTF
Diagnostics overview and FB for the XFEL bunch compressors
Transverse emittance measurements
Beam size diagnostics using diffraction radiation
UCLA/ATF chicane compression experiments
High Level Physics Applications for LCLS Commissioning
Injector Experimental Results John Schmerge, SSRL/SLAC April 24, 2002
Experience with photoinjector at ATF
CLIC luminosity monitoring/re-tuning using beamstrahlung ?
Presentation transcript:

High Dynamic Range Beam Imaging with a Digital Optical Mask* Presented by Tim Koeth (UMD) on behalf of R.B. Fiorito, H.D. Zhang, A. Shkvarunets UMD, College Park, Maryland S. Zhang, S. V. Benson, D. Douglas, F. G. Wilson JLAB, Newport News, Virginia *Work Funded by US ONR, DOD JTO and DOE Office of HEP 1 DITANET Beam Diagnostics Conference November 9-11, 2011, Seville, Spain

Outline Introduction Motivation and Challenges of Halo Measurements Current diagnostic techniques New Adaptive Halo Imaging Technique using Digital Micromirror Device (DMD) Experimental Results University of Maryland Electron Ring (UMER) JLAB FEL Future Plans 2

Motivation and Challenges Negative effects of Beam Halo Beam Loss Activation of Beam line components Emittance Growth Emission of Secondary Electrons Increased Noise in Detectors 3 Challenges to diagnostics of halos Need high dynamic range: >~10 5 Adaptive to variable beam core

Wire Scanner and Scraper Assembly Low-Energy Demonstration Accelerator - LANL DR: 10 5 T.P.Wangler, et. al., Proc. PAC01 Ionization beam profile monitor DR: 10 3 P. Cameron, et al. Proc. of PAC99: , 1999 Previous Experimental Methods 4 High Dynamic Range Camera Spectra-Cam CID $$ DR >10 5 measured with laser C.P. Welsch, et., Proc. SPIE 6616,9 (2007). Passive Spatial Filtering solar coronagraphy applied to beams DR: T. Mitsuhashi, EPAC Imaging Techniques

Digital Micro-mirror Device* 12 0 *DLP TM Texas Instruments Inc. 5 Array dimensions: 14 x 10 mm Pixels: 1024 x 768, Pixel dimension: 14x14  m Switching rate: 9600 fps Individual pixel addressable Used in HD TV & Projectors Available as development ‘kits’ Optimized to visible, IR, UV

Beam Halo Imaging System using DMD developed at UMD * Computer Mirror Source Halo Light Core Light DMD Camera Sensor L3 L4 L1 L2 Computer Camera Sensor L3 Mirror Source L1 DMD L2 L4 Image 2 Image 1 Mask Frames 32 mm 900 Frames 32 mm *R.Fiorito, H.Zhang, A. Shkvarunets, et. al. Proc. BIW2010 Beam optical radiation Pixels near saturation DR >10 5 Two compensations are needed, DMD rotated 45 o & path length

DMD mirror Target Image on DMD Lens Incident light re flected light Scheimpflug compensation 7 Micro- mirrors θφ Image on DMD Image on CCD Lens focus length f Scheimpflug intersection vu

Beam Image on e.g. 512x512 pixel CCD Generate and apply Mask to DMD Magnify x0x0 y y0y0 x y’ x’ x0’x0’ y0’y0’ Dx Dy 1024 pixel 768 pixel DMD coordinates Y’’ X’’ Re-image beam (a) (b) (c) (d) (e) Mask Generating Algorithm 8

Screen DMD Imaging Experiments on University of Maryland Electron Ring (UMER) Energy (keV)10 Pulse width (ns)100 Repetitive rate (Hz)20-60 Beam current (mA)0.6, 6, 21,80 9 Screen

Dynamic Range measurement of imaging system 10 Integration Frames: 20 Phosphor screen image of 21 mA beam mm pixel

11 Dynamic Range Measurement at UMER 32mm Log I/I mm

Spatial Filtering Ability of DMD Beam on, DMD all onBeam on, DMD all off mA beam 32mm

DMD all on (with Scheimplug compensation) Simple Mirror (no compensation) DMD all floating (no compensation) Comparison of Images obtained with DMD and Mirror 13

Quadrupole Screen Quadrupole Induced Halo Experiments on UMER 14 Screen

x y (a) (b) IQIQ %I Q 66.3%I Q 49.7%I Q Demonstration of adaptive threshold masking Quadrupole Current 32mm 15

Bending Magnet Non Interceptive Beam/Halo Imaging at JLAB using Optical Synchrotron Radiation 16 Quadrupoles

500 G 300 G0G -500 G -700 G G G 0 G G G G 4 mm Quadrupole Scan Using OSR with Tune-up Beam (E=135 MeV, I= 0.32mA: 2Hz rep-rate,  s macro, 4.68MHz micro, 135pC/micro ) Quad strength

11.6 mm 0.04 s0.18 s 1.6 s 6.5 s 42 s OSR Halo Imaging of JLAB CW beam with DMD threshold mask (I = 0.63 mA, 4.68MHz, 65pc/micropulse,  654nm x 90nm, ND=0.4 )

Measurement of Dynamic Range of imaging system

Measurement of Dynamic Range of 0.6 mA CW Beam

( ) J max ( ) J max Reconstructed intensity distribution J(x,y) and calculated total radiant energy E Total ( ) J max

Summary Results Developed and tested high-dynamic range ( DR ~10 5 ) halo diagnostic imaging system using a phosphor screen + DMD at UMER Developed a non interceptive OSR DMD imaging system to observe beam halo at JLAB FEL under CW operating conditions; with measured DR > Performed quad scan of JLAB tune-up beam using OSR Future plans UMER: Do time-resolved halo imaging and multi-turn halo evolution studies at UMER using DMD to study/mitigate factors effecting halo JLAB: Short terms: Verify and possibly improve DR >~10(5) of present system 1a) Improve background measurements and verify halo is not due to stray light from upstream internal sources 1b) decrease optical magnification onto DMD and /or increase current density via current, focusing/tune; Long term: Extend DR of halo measurement to limit: 1) add Lyot and/or apodizing stops to decrease effect of diffraction 2) improve optical transport with enclosures and antireflection coating on optics port to further reduce any external stray light Compare emittance measurements using OTR and OSR quad scans Explore possibility of using DMD to measure halo/core emittances and to do optical phase space mapping (optical analogy of pepper pot technique)