PAT TESTER CALIBRATION Using the 3200 Electrical Test Calibrator.

Slides:



Advertisements
Similar presentations
As a stand-alone overview of test tools.
Advertisements

LEA Assessor Presentation LEP Results
Understanding Electrical TransmissionDemonstration D1 A Guide to the National Grid Transmission Model Demonstration D1 Power losses in transmission.
Undertake basic electrical tasks
Special Diodes. Describe and analyze the function and applications of:  Zener Diodes.
2- Figure shows a circuit diagram. Determine the current,
The Association of Electrical and Medical Imaging Equipment Manufacturers Understanding GFCIs Developed by the NEMA 5PP Personnel Protection Technical.
Electrical Safety Testing of Electrical Installations and the verification of Electricians Test Tools Michael Bailey Transmille Ltd NCSLi 2014Transmille.
ProCal Calibration Software
Safety Testers (plus more) from Dranetz and Gossen Metrawatt General Presentation.
3200A Electrical Test Equipment Calibrator. Automatic Loop Correction To simplify calibration of loop testers, the 3200A can be fitted with the Auto.
3200A Options / Technical Overview. 3200A Electrical Test Calibrator Innovative design to bring advances in technology to the calibration of Electrical.
‘L’ Work Shop Electrical Testing. 440V ER V ER V ER1-1 ER1-1-1 ER1-1-2 ER1-1-3 Via Tx 115V ER1-1-3 ER ER A SOCKETS 2E 115V.
A fuse contains a thin wire that heats up and melts if too much current passes through it. The rating of a fuse is the maximum current that can pass through.
INSULATION TESTER CALIBRATION Using the 3200 Electrical Test Calibrator.
Electricity. Starter:  What is current?  What is it measured in?  What is it measured by?  Which is the series and parallel circuit? (see board)
Circuits & Electronics
TRANSMILLE PATs The New Alternative To Fast, Easy & Efficient Portable Appliance Testing.
PROEDIT WRITING A PROCEDURE USING THE BUILT-IN PROCEDURE WIZARD.
Four identical resistors, P, Q, R and S are connected as shown. In which of the resistors is the current the same? 1.P and Q only 2.R and S only 3.P, R.
Introduction to Current Electricity, Part 1
RCD TESTER CALIBRATION Using the 3200 Electrical Test Calibrator.
Beath High School - Int 1 Physics1 Intermediate 1 Physics Practical Electricity Glossary ammeter to circuit circuit breaker to consumer unit continuity.
Electrical Resistance and Ohm’s Law Electric circuits are used to convert electrical energy into some other form of energy we need.
Measurements in Electric Circuits Gr. 9 Electricity Unit.
DMM4020 Digital Multimeter Fact Sheet Measurements with the Push of a Button Features Featuring:  5.5 digit resolution  Basic V dc accuracy of up to.
SS2 AND SS3 2014/2015 SESSION. In order to enjoy the various advantages of electricity in premises certain precautionary and method of wiring using appropriate.
Physics Electricity in the home. Direct current (d.c.) is an electric current that always flows in one direction. Made by batteries. Electronic circuits.
Lesson 6 Voltage Do we need to MEASURE it? OR Do we need to DETECT it?
ELECTRICITY AT WORK REGULATIONS THE REGULATIONS DICTATE THAT ALL PORTABLE EQUIPMENT MUST BE INSPECTED REGULARLY AND TESTED TO ENSURE THAT IT IS.
Introduction to Current Electricity, Part 1 Grade 9 Academic Science R.H. King Academy.
Quiz on Domestic Electrical Appliances. 1. A resistance coil is also called a heating coil. a fuse. an earth wire. a live wire.
/1 Standby Power & IEC62301.
Bellringer A standard household outlet has a voltage of what?
Electrical Faults Open Circuit
McGraw-Hill © 2013 The McGraw-Hill Companies Inc. All rights reserved. Electricity Principles & Applications Eighth Edition Chapter 3 Basic Circuits,
Limiting Maximum Current of the Power Supply. Which Meter has almost zero resistance? Current meter R i  0  e.g.,  R i 
3200 Electrical Test Equipment Calibrator The Total Solution to Electrical Test Equipment Calibration.
PORTABLE & TRANSPORTABLE ELECTRICAL EQUIPMENT. Legal Requirement and References Abu Dhabi RSB Electrical Regulations - makes reference to the need to.
4.1 Current and charge Electrical conduction Electrical conduction: * is the movement of charge carriers, eg electrons * the rate of flow of charge is.
16 th Edition Testing FAQ Common Issues With 16 th Edition Testing.
STATE ROAD TRANSPORT INSPECTORATE UNDER THE MINISTRY OF TRANSPORT AND COMMUNICATIONS 2011 m.
Testing of Low Voltage Installations
LOOP TESTER CALIBRATION Using the 3200 Electrical Test Calibrator.
 V s /V p = N s /N p  I p V p = I s V s  I p /I s = V s /V p = N s /N p  V s = (N s /N p )V p  I s = (N p /N s )I p  P = VI; I = P/V (I.
Brandon Portable Appliance Testing & R.C.D. Training The benefits, frequency and procedure for electrical safety testing.
Touch (Leakage) Current
Using electrical Test Equipment To accompany the Georgia Agriculture Curriculum Course: AG-AG-AMII Using Electrical Test Equipment 2010 VGP.
SeaPerch Electrical System. Electrical System Overview Assemble the control box. Make the Cat5 connector. Wire the motors to the tether. Wire the control.
Using sensors with Flowol 2. There are 2 ways that you can use sensors with Flowol 2 software. 1.You can use SIMULATION mode – when you use a MIMIC 2.You.
Jag Mark Name 4 factors that can affect the resistance of a current?
Product Overview Analogue Input, 2fold, SM  Box  Sensor connections
PROTECTION AGAINST INDIRECT CONTACT
SeaPerch Electrical System
What should we do to make sure we use electricity safely?
PTS 3.3 C Portable Test System.
Basic Definitions Power 1 Circuit 2
EARTH-LEAKAGE AND GROUND-INTEGRITY MONITOR
HVI HIPOT TEST SET Pft sERIES.
The Electricity at Work Regulations 1989
Gadget Hub Power (mains) Controller.
Electrical Energy Sources
PROCAL PERFORMING A CALIBRATION ON A MOTECH MIC39 MULTIMETER.
Resistance in Series and Parallel
Click Summary Value Button to Show Source of Integral or Time
Voltage Difference The difference in electrical potential between two places. Unit of measure = V (volts) Voltage causes current to flow through an electric.
ELECTRICITY & MAGNETISM Electrical Resistance (P )
Electrical components and systems
SeaPerch Electrical System
Introduction of the IEC Modification Proposal 61/5925/INF
Presentation transcript:

PAT TESTER CALIBRATION Using the 3200 Electrical Test Calibrator

Dedicated inputs and test buttons for PAT Testers provides safe, convenient connection & operation The 3200 has six functions which can be used for testing of Portable Appliance Testers (PATs) : 1. Earth Bond Resistance measurement 2. Earth Bond Current measurements 3. Insulation testing 4. Load testing 5. Flash Testing 6. Leakage Testing PAT TESTER CALIBRATION Overview

1.CONNECT TESTER TO PAT EARTH BOND TERMINAL AND PAT TEST IEC SOCKET 2.SET EARTH BOND RESISTANCE FUNCTION ON TESTER 3.SET EARTH BOND RESISTANCE RANGE ON 3200, EG. 1 OHM 4.START EARTH BOND MEASUREMENT ON PAT TESTER PAT TESTER CALIBRATION PAT Earth Bond Resistance

PAT TESTER CALIBRATION PAT Earth Bond Current 1.CONNECT PAT TO 3200 EARTH BOND TERMINAL USING SPECIFIC EARTH BOND CURRENT TERMINAL & CONNECT TO PAT TEST IEC SOCKET 2.SET EARTH BOND FUNCTION ON TESTER 3.SET EARTH BOND CURRENT RANGE ON 3200, EG. 10A AND CLICK ‘TEST’ SOFTKEY 4.START EARTH BOND MEASUREMENT ON PAT TESTER – WAIT FOR 5 SECOND TEST INTERVAL

PAT TESTER CALIBRATION PAT Insulation Resistance 1.CONNECT PAT TO 3200 EARTH BOND TERMINAL & CONNECT TO PAT TEST IEC SOCKET 2.SET INSULATION RESISTANCE MEASUREMENT FUNCTION ON TESTER 3.SET PAT INSULATION RANGE ON 3200, EG. 9M OHMS 4.START INSULATION RESISTANCE MEASUREMENT ON PAT TESTER

PAT TESTER CALIBRATION PAT Load Testing 1.CONNECT PAT TO 3200 EARTH BOND TERMINAL & CONNECT TO PAT TEST IEC SOCKET 2.SET LOAD / RUN TEST FUNCTION ON TESTER 3.SET PAT LOAD MODE AS REQUIRED (O/CS/C0.13kVA) 4.START MEASUREMENT ON PAT TESTER

PAT TESTER CALIBRATION PAT Leakage Current 1.CONNECT PAT TO 3200 EARTH BOND TERMINAL & CONNECT TO PAT TEST IEC SOCKET 2.SET LEAKAGE CURRENT MEASUREMENT FUNCTION ON TESTER 3.SET LEAKAGE RANGE ON 3200, EG. 2mA 4.START LEAKAGE MEASUREMENT ON PAT TESTER SUBSTITUTE LEAKAGE MEASUREMENT CAN ALSO BE PERFORMED AT 40V TEST LEVELS USING THE 3200