Plot85 A program to plot and analyze energy-dispersive diffraction data Written by Kenneth Baldwin, with contributions from: Donald Weidner (stress calculations)

Slides:



Advertisements
Similar presentations
1. Cable connection - Adjust Gain to make Mn K signal (5.895 keV) around 2 V on oscilloscope. (Full range : 10 V)
Advertisements

WHAT IS ELINK? Thermoflow, Inc.
UNLOCKING THE SECRETS HIDDEN IN YOUR DATA Part 3 Data Analysis.
Multi-DNC Data Collection/Monitoring
Synchrotron Diffraction. Synchrotron Applications What? Diffraction data are collected on diffractometer beam lines at the world’s synchrotron sources.
 Statistics package  Graphics package  Programming language  Can be used to share/reproduce analyses  Many new packages being created - can be downloaded.
PIXE: Data Analysis What the data can (and cannot) tell us. Larry Lamm PIXE Seminar Winter 2008.
T.G. Fawcett, S. N. Kabbekodu, F. Needham, J. R. Blanton, D. M. Crane, J. Faber International Centre for Diffraction Data Using PDF-4+/Organics to discover.
RHESSI/GOES Observations of the Non-flaring Sun from 2002 to J. McTiernan SSL/UCB.
T T20-01 Mean Chart (Known Variation) CL Calculations Purpose Allows the analyst calculate the "Mean Chart" for known variation 3-sigma control.
1 Lab Session-I (A and B) CS-120 Fall 2000 Using Windows Using An Editor Using Visual C++ Using Compiler Writing and Running Programs Lab-1 DUE Fri September.
1 Lab Session-I CSIT120 Spring2001 Using Windows Using An Editor Using Visual C++ Using Compiler Writing and Running Programs Lab-1 continues (Session.
Division Example 2x - 3y + 4z = 10 x + 6y - 3z = 4 -5x + y + 2z = 3 A*X = B where A = B = >> X = A\B X =
EDAX Operation Operation of the Phoenix EDAX system
T T20-00 Range Chart Control Limit Calculations Purpose Allows the analyst to calculate the "Range Chart" 3- sigma control limits based on table.
CS1100: Computer Science and Its Applications Creating Graphs and Charts in Excel.
NextPrevious CFlow+ Calibration Control Software Software upgrade for: Piston Calibrators / Provers Flow Transfer Standard - Gas & Liquid Bell Provers.
NREL is a national laboratory of the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy operated by the Alliance for Sustainable.
1 QED In Vivo USB Input Output Box configuration This tutorial contains a number of instructions embedded in a great deal of explanation. Procedures that.
Is automatic Peak ID infallible: Major constituents (C > 0.1 mass fraction or 10%)? Minor (0.01 < C < 0.1 mass fraction, 1-10%)? Trace (C < 0.01 mass fraction.
DEMONSTRATION FOR SIGMA DATA ACQUISITION MODULES Tempatron Ltd Data Measurements Division Darwin Close Reading RG2 0TB UK T : +44 (0) F :
Adobe Forms THE FORM ELEMENT PANEL. Creating a form using the Adobe FormsCentral is a quick and easy way to distribute a variety of forms including surveys.
2 $ command Command Line Options ls –a –l hello hi Command Arguments.
X-ray Diffraction Outline Crystals and Bragg Diffraction
OPC Data Logger Start Up Instructions. OPC Data Logger For most experiments run in DPCL, data is analyzed from graphs. All process variables shown on.
TrendReader Standard 2 This generation of TrendReader Standard software utilizes the more familiar Windows format (“tree”) views of functions and file.
NR6 Rhinomanometer The following presentation gives an overview of the main functions of the NR6 Rhinomanometer, it’s accessories and normal operational.
Detector noise analysis (DINO) demo Max Mutchler ACS-R Optimization Campaign dry-dryrun 30 January 2009.
Introduction to p:IGI-3 Integrated Geochemical Interpretation Ltd. Hallsannery, Bideford, Devon EX39 5HE, UK.
Internet and Distributed Representation of Agent Based Model by- Manish Sharma.
C++ Basics Structure of a Program. C++ Source Code Plain text file Typical file extension .CPP Must compile the C++ source code without errors before.
Software for economic concrete design Efficient Analysis with the Strand7 API Doug Jenkins - Interactive Design Services.
1 The EDIT Program The Edit program is a full screen text editor that allows you to: Create text files Create text files Edit an existing text files Edit.
Introduction to Engineering MATLAB – 6 Script Files - 1 Agenda Script files.
Reporting in Version 5 Application Reports AKA: In Context or Right Click AKA: In Context or Right Click Export to Excel from Listing pages Management.
Arrays, File Access, and Plotting
DATA, SITE AND RESOURCE MANAGEMENT SOFTWARE. A Windows application software designed for use with Stylitis data loggers. EMMETRON consolidates resources,
Getting Started with MATLAB 1. Fundamentals of MATLAB 2. Different Windows of MATLAB 1.
Displaying the results of an XPS Depth Profile Laura Blair.
OL Series 750 Automated Spectroradiometric Measurement System The OL Series 750 is an extremely versatile spectroradiometric measurement system capable.
Computer Literacy BASICS: A Comprehensive Guide to IC 3, 5 th Edition Lesson 19 Organizing and Enhancing Worksheets 1 Morrison / Wells / Ruffolo.
1 SIeve+ Introduction SIeve+ is a Plug-In module to the DDView+ software which is integrated in the PDF-4 products. SIeve+ is licensed separately at an.
Jos de Bruijne Relativity and Reference Frame Working Group Meeting ESTEC, June 2004 Gaia Parameter Database
Editors And Debugging Systems Other System Software Text Editors Interactive Debugging Systems UNIT 5 S.Sharmili Priyadarsini.
Algorithms  Problem: Write pseudocode for a program that keeps asking the user to input integers until the user enters zero, and then determines and outputs.
Chapter 1 – Matlab Overview EGR1302. Desktop Command window Current Directory window Command History window Tabs to toggle between Current Directory &
Miscellaneous 1 Miscellaneous 2 Slide ShowEditingGraphics
FROM IMAGES TO ANSWERS Live Cell Imaging - Practical Issues Silver Spring & San Diego, June 2005.
AESuniversity Ad hoc Reporting Version 5. for the special purpose or end presently under consideration concerned or dealing with a specific subject, purpose,
Offline and Monitoring Software for the EMEC+HEC Combined Run Combined Test Beam and LArg Software and Performance 11 September 2002 Rob McPherson University.
Running GC.
Using SPSS Note: The use of another statistical package such as Minitab is similar to using SPSS.
Page: Clarity PDA Extension Date: Code: P001/28A.
UNC to NCDOJ Banner Student Accounts Interface Fayetteville Fort Bragg.
April 9 th, Saturday PDP N° Malik Koné. I. Cells A. The Concept B. Properties, Types and Formats II. Spreadsheets A. Spreadsheet’s Elements B. Selection.
SAS ® 101 Based on Learning SAS by Example: A Programmer’s Guide Chapters 14 & 19 By Tasha Chapman, Oregon Health Authority.
Authors: Dmitrii Pereima, ITEP; Dmitry Golubkov, ITEP; Iouri Gouz, IHEP; Victor Egorychev, ITEP. Visualization of HCAL 137 Cs calibration data 1 CALO +
Solvency II Tripartite template V2 and V3 Presentation of the conversion tools proposed by FundsXML France.
Microsoft Excel Illustrated Introductory Workbooks and Preparing them for the Web Managing.
Performance Margins for Snowmaking
Software for Crystallographic and Rietveld Analysis
Electron probe microanalysis EPMA
Using SPSS Note: The use of another statistical package such as Minitab is similar to using SPSS.
A Step-by-Step Procedure for Preparing BBS Sheets with Manual Entry of Each Bar is shown here Select BarBeQue 2009 Icon From Desktop Start Program BarBeQue.
Amos Introduction In this tutorial, you will be briefly introduced to the student version of the SEM software known as Amos. You should download the current.
Animated PowerPoint Template
5/8/2019 3:20 AM bQuery-Tool 3.0 A new and elegant way to create queries and ad-hoc reports on your Baan/Infor ERP LN data. This Baan session is a query.
Put the title here Here is the sub-title.
Put the title here Here is the sub-title.
Using SPSS Note: The use of another statistical package such as Minitab is similar to using SPSS.
Presentation transcript:

Plot85 A program to plot and analyze energy-dispersive diffraction data Written by Kenneth Baldwin, with contributions from: Donald Weidner (stress calculations) Kurt Leinenweber (implementation of the Decker EoS) Wayne Dollase (peak search) Robert Downs and Kurt Bartelmehs (Xpow) Charlie Prewitt (Celrf) David Cox, Warren Hamilton, Larry Finger and others (GPLS)

What can Plot85 do? Graphically display energy-dispersive diffraction data for multiple detectors and different 2 q s Fit peaks using least-squares (GPLS) Calibrate such data using known diffraction, fluorescence, and radioactive source information Measure stress/strain present in the data Adjust reference data for pressure and/or temperature Do all these things fairly easily All of these things could also be done manually, using multiple programs such as PeakFit, Excel, but here there are all done in one package.

Basic Operating Parameters Written in Fortran, compiled to run under Windows (any recent version including Vista) Reads ASCII files in several formats: – Native MED format from NSLS or APS sources – MCA format defined at NSLS – X-Y data – Scintag text file – GSAS format – Spring8 format Each of these formats has one channel of data per line, with (optional) headers The MED (multi-element detector) format has as many data points per line as there are detector elements.

Typical Format for MED and APS Files the only difference is the format of the file specification – the extension of APS files is.nnn, (the file sequence number) while that for MED files is.MED, (the file sequence number is in the filename). Parameters listed in Green are read in by Plot85 and used for some calculations. VERSION: 3.1 version number for the MED data collection software (EPICS) ELEMENTS: 4 number of detector elements DATE: FEB 10, :31: CHANNELS: 2048 ROIS: number of Regions of Interest for each detector REAL_TIME: data collection time LIVE_TIME: data collection time CAL_OFFSET: e e e e-002 } CAL_SLOPE: e e e e-002 } energy calibration parameters CAL_QUAD: e e e e-008 } TWO_THETA: ROI_0_LEFT: ROI_0_RIGHT: ROI_0_LABEL: wad240 & wad240 & wad240 & wad240 & ENVIRONMENT: X17B2:OperatorName.VAL="E6351 Y8040 E6351 U7703 J7501 U7659" ( ) ENVIRONMENT: X17B2:SampleName.VAL="hot-pressed MgO" ( ) ENVIRONMENT: X17B2:ExperimentComment1.VAL=" " ( ) ENVIRONMENT: X17B2:ExperimentComment2.VAL=" " ( ) ENVIRONMENT: X17B2:ExperimentComment3.VAL=" " ( ) ENVIRONMENT: X17B2:ExperimentComment4.VAL="MgO" ( ) ENVIRONMENT: X17B2:ExperimentComment5.VAL="MgO" ( ) ENVIRONMENT: X17B2:LVP_furnace_calcs.G="-0.000" (main pump pressure Keithley channel 9 Heise gauge) ENVIRONMENT: X17B2:LVP_tc1_calcs.I=" " (Thermocouple1 Temperature) ENVIRONMENT: X17B2:LVP_furnace_calcs.D="0.002" (Heater power) many more ENVIRONMENT:X17B2 variables DATA: number of counts in channel 0 for each of the four detectors number of counts in channel 1 for each of the four detectors number of counts in channel 2 for each of the four detectors Continues for a total of 2048 channels of data

Reference Files (“Standards” Files) Accessory files and information can be included in the plots. These include: Standard.hkl *.jcpds *.pow X-ray fluorescence (built in)

Standard.hkl A list of up to 40 diffraction standards, with up to 20 lines each NaCl name of standard, any text up to 20 characters long ,,,,,,1 unit cell dimensions, plus a sample identifier (sample identifier non-zero for NaCl and MgO only) 1,1,1,3.26,13.,2 h, k,l, d, intensity, peak orientation identifier, for 1st peak 2,0,0,2.821,100.,1 h, k,l, d, intensity, peak orientation identifier, for 2nd peak 2,2,0,1.994,55.,3 2,2,2,1.628,15.,2 4,2,0,1.261,11.,4 999,0,0,0,0 terminating line Al2O ,4.758,12.99,90.,90.,120.,0 0,1,2,3.4802,75. 1,0,4, ,90. 1,1,0,2.3796,40. 1,1,3,2.0855,100. 0,2,4,1.7401,45. 1,1,6,1.6015,80. 1,2,4,1.4046,30. 0,3,0,1.3739,50. 1,0,10,1.2391,35. 1,1,9,1.2343,8. 2,2,0,1.1898,8. 2,2,3,1.1470,6. 3,2,1,1.1255,6. 2,0,10,1.0990,9. 0,0,12,1.0831,4. 1,3,4,1.0781,8. 2,2,6,1.0426,14. 2,1,10,0.9976, ,0,0,0,0

MgO.jcpds (versions 1 & 4) One diffraction standard, with up to 20 lines each VERSION: 4 COMMENT: MgO (JCPDS , EOS from Jackson) K0: K0P: SYMMETRY: CUBIC A: ALPHAT: DIHKL: DIHKL: DIHKL: DIHKL: DIHKL: DIHKL: DIHKL: DIHKL: DIHKL: DIHKL: MgO (JCPDS , EOS from Duffy et al, 95) , 177.0, d (A) I/I0 h k l

Most of the operations occur within the graphics window (shown above), but much of the output is in the text window Some of the output is put into text files.

Running the program creates two windows, a text window and a graphics window.

Description of Plot After the file is plotted, the following are displayed (next slide): The diffraction spectrum in terms of channel number Calibration information used, including 2 q Reference spectrum, for “standard” listed Two “Titles” – in our operations, Title 1 applies to the entire data set, and Title 2 applies to the current file only Filename and Path of displayed file Detector element number