Latest progress in PMT development VLVnT11 in October, 2011 Hamamatsu Photonics K.K. Electron Tube Division Yuji Hotta.

Slides:



Advertisements
Similar presentations
Picosecond Timing Workshop 18 November Sales meeting 2005 Discovering the Future.
Advertisements

Selection and performance of PMT candidates for TREND ground array Hou Yueyun 1, Feng Zhaoyang 1, Liu Cheng 1 , Liu Maoyuan 1 1, IHEP 2, Tibet University.
6 April 2005Aussois, France BURLE INDUSTRIES Next Generation Large Area Low Cost PMT UNO Collaboration Robert Caracciolo and Richard Leclercq 6 April 2005.
PID Univ. 31.Aug.2002 Contents 1.Introduction 2.PMT structure & Set up 3.Basic performance 4.Experiment results –Gain –Time resolution.
Time-of-Flight at CDF Matthew Jones August 19, 2004.
Study of Photon Sensors using the Laser System 05/7/12 Niigata University, Japan Sayaka Iba, Editha P. Jacosalem, Hiroaki Ono, Noriko.
Hamamatsu Photonics K.K. Electron Tube Division R for ICECUBE 1.Delivery Record and Plan 2.Specification of R Test Result at Hamamatsu.
Test Results on the Photomultiplier Tubes for the ANTARES Neutrino Telescope Juan-de-Dios Zornoza IFIC (CSIC–Valencia University, Spain) On behalf of the.
The Origins of X-Rays. The X-Ray Spectrum The X-Ray Spectrum (Changes in Voltage) The characteristic lines are a result of electrons ejecting orbital.
Transducers Converts one type of energy into another. Light  Electrical (current, voltage, etc.) What characteristics should we look for in a transducer?
The UC Simulation of Picosecond Detectors Pico-Sec Timing Hardware Workshop November 18, 2005 Timothy Credo.
Demonstration and comparison of photomultiplier tubes operation at liquid Argon Temperature Ettore Segreto LNGS (Italy) On behalf of the WArP Collaboration.
10 Picosecond Timing Workshop 28 April PLANACON MCP-PMT for use in Ultra-High Speed Applications.
Measurement of the absolute efficiency,
Copyright © Hamamatsu Photonics K.K. All Rights Reserved. Oct at NNN07 Workshop Hamamatsu Photonics Electron Tube Division Recent Progress in PMTs.
1 Light Collection  Once light is produced in a scintillator it must collected, transported, and coupled to some device that can convert it into an electrical.
Hamamatsu R7525 HA: outer conductive coating with insulating sleeve CC: convex-concave window mm thick (standard plano-concave: 1mm center, 6.1.
Photon detection Visible or near-visible wavelengths
Latest developments in Hamamatsu Large Format PMTs
Catania VLVnT09 Athens, Greece 1/14 Catania Performances of four super bialkali large area photomultipliers with respect to.
1 Performance of multi-anode PMT employing an ultra bi-alkali photo-cathode and rugged dynodes Takahiro Toizumi Tokyo Institute of Technology S. Inagwa.
Fast Detectors for Medical and Particle Physics Applications Wilfried Vogel Hamamatsu Photonics France March 8, 2007.
Founded in 1906 by Nahum Kolmanok; 1913 – merging with bulb factory “Light”. As a result, “Russian electric lamp” manufacture was established; 1921 –
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
Photodetection EDIT EDIT 2011 N. Dinu, T. Gys, C. Joram, S. Korpar, Y. Musienko, V. Puill, D. Renker 1 Micro Channel plate PMT (MCP-PMT) Similar to ordinary.
WSO/UV-LSS Detector with large dimension MCP Baosheng Zhao* National Astronomical Observatories of CAS *
Improved PMTs for the Cherenkov Telescope Array project Razmik Mirzoyan for the Focal Plane Instrumentation WG Max-Planck-Institute for Physics Munich,
Developments in hemispherical tubes for underwater Neutrinos detection. Bruno Combettes PHOTONIS Group Product Manager PHOTONIS-Brive, France CPPM Meeting.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
LOGO The VSiPMT Project Progress in the realization of a larger prototype Felicia Barbato – University of Naples “Federico II” – Italy.
Bbbbb 1.Introduction to ET Enterprises Ltd 2.Brief History 3.Product Range 4.Main Applications 5.Recent Developments 6.Current and Past projects 7.Summary.
Optimization of Detectors for Time of Flight PET Marek Moszyński, Tomasz Szczęśniak, Soltan Institute for Nuclear Studies, Otwock-Świerk, Poland.
Andy Cormack Sensor Development Director Graham Sperrin European Sales Manager ET Enterprises Limited 45 Riverside Way Uxbridge UB8 2YF United Kingdom.
Timing properties of MCP-PMT K.Inami (Nagoya university, Japan) - Time resolution - Lifetime - Rate dependence Photon Detector Workshop at Kobe,
1 LAPPD Team meeting 6/10/2010 Ossy Siegmund, Experimental Astrophysics Group, Space Sciences Laboratory, U. California at Berkeley Bialkali Photocathode.
Techniques for Nuclear and Particle Physics Experiments By W.R. Leo Chapter Eight:
8 April 2005Aussois, France BURLE INDUSTRIES Recent Photomultiplier and Device Developments NNN05 Robert Caracciolo 8 April 2005 BURLE INDUSTRIES.
Development of Multi-Pixel Photon Counters(MPPC) Makoto Taguchi Kyoto University.
Catania Study on large area photomultipliers with superbialkali photocathode E. Leonora 1, S. Aiello 1, D. Lo Presti 2, V. Giordano 1 1 INFN, section of.
R. Pani Department of Experimental Medicine and Pathology University of Rome La Sapienza-Italy. Flat Panel PMT: advances in position sensitive photodetection.
Catania 11 ICATPP october, 2009 Como 1/12 Catania Comparative measurements of the performances of four super bialkali large.
1/27/2016Katsushi Arisaka 1 University of California, Los Angeles Department of Physics and Astronomy Katsushi Arisaka XAX 10.
Large Format PMTs from Hamamatsu Photonics
TIMING COUNTER: status report Giorgio CECCHET, PSI July 11th, 2003.
CMS HF PMT SYSTEM By Y. ONEL U. of Iowa, Iowa City, IA CMS HCAL at Fermilab Feb 6-8, 2003.
CMS HF PMT SYSTEM By Y. ONEL U. of Iowa, Iowa City, IA HF-RBX PRR CERN Apr 3-4, 2003.
Characterization of the QUartz Photon Intensifying Detector (QUPID) Artin Teymourian UCLA Dark Matter Group Dept. of Physics and Astronomy.
Basic Measurement of the Hamamatsu 10 inch PMT at –40 degree –40 degree Hiroko Miyamoto Dept. of Physics CHIBA University The Uniformity measurement of.
Three inch PMTs. Manufacturers ETEL 72 mm photocathode tube ready Passes all specifications (has higher than wished afterpulse rate: this is being fixed.
The VSiPMT: A new Generation of Photons Detectors G. Barbarino 1,2, F. C. T. Barbato 1,2, R. de Asmundis 2, G. De Rosa 1,2, F. Di Capua 1, P. Migliozzi.
Status of NEWCHOD E.Guschin (INR), S.Kholodenko (IHEP), Yu.Kudenko (INR), I.Mannelli (Pisa), O.Mineev (INR), V.Obraztsov (IHEP), V.Semenov(IHEP), V.Sugonyaev.
G. Kieft Nikhef Amsterdam Electronics- Technology PMT tubes PMT bases PMT asic’s Automatic tester for PMT bases Camac test set-up for PMT tubes LeCroy.
Characterization of Hamamatsu R12199 PMTs Oleg Kalekin KM3NeT Meeting CPPM, Marseille
CaMoO 4 at low temperature - LAAPD and PMTs - Woonku Kang, Jungil Lee, Eunju Jeon, Kyungju Ma, Yeongduk Kim Sejong University for KIMS collaboration Double.
1 Development of a Large Area Photodetector with a Fast Phosphor Anode Toru Iijima Kobayashi-Maskawa Institute Nagoya University Open Meeting for the Hyper-Kamiokande.
The photomultiplier tubes selection for KM2A electromagnetic particle detectors (EDs) hou chao IHEP The 2nd workshop of air shower detection at high altitudes.
M.Taguchi and T.Nobuhara(Kyoto) HPK MPPC(Multi Pixel Photon Counter) status T2K280m meeting.
Candidate light sensors for CTA High precision measurements of ultra-low light level detectors for CTA project: PMTs and SiPMs Matthias Kurz Max-Planck-Institute.
Performance of 1600-pixel MPPC for the GLD Calorimeter Readout Jan. 30(Tue.) Korea-Japan Joint Shinshu Univ. Takashi Maeda ( Univ. of Tsukuba)
1 SuperB-PID, LNF 4/4/2011 MAPMTsSilvia DALLA TORRE COMPASS experience with HAMAMATSU MAPMTs S. Dalla Torre.
Status procurement of PMTs Oleg Kalekin KM3NeT WPF/L General Meeting Amsterdam
CMS HF PMT SYSTEM By Y. ONEL U. of Iowa, Iowa City, IA HF-RBX PRR CERN Apr 3-4, 2003.
Characterization of the ETEL and HZC 3+ inch PMTs
PMT characterisation for the KM3NeT Project
Sebastian Kuch University Erlangen-Nürnberg
Large Area MCP-PMT and its Application at JUNO
Department of Physics and Astronomy,
Deng Ziyan Jan 10-12, 2006 BESIII Collaboration Meeting
Recent Progress in Large Format PMTs
Development of hybrid photomultiplier for Hyper-Kamiokande
Presentation transcript:

Latest progress in PMT development VLVnT11 in October, 2011 Hamamatsu Photonics K.K. Electron Tube Division Yuji Hotta

1. Profile of Hamamatsu 2. 3 inch PMT Development for KM3NeT inch PMT Development Contents

1. Profile of Hamamatsu

Hamamatsu is a name of a city. HONDA, YAMAHA and SUZUKI (famous motor cycle companies) are located in the same area. Population : 818K (as of October 1, 2011) KAWAI ROLAND Where we are located

JAPAN Japanese Standard MAP Europe USA (Subsidiaries) Global Network of Hamamatsu

Established : Sept 29, 1953 Employees : 4,167 (Group) (As of Jun 2011) Net Sales : \91B (€830M) (FY2010) Electron Tube Division Solid Sate Division Systems Division Laser Group Central Research Lab Hamamatsu Photonics K.K.

2. 3 inch PMT Development for KM3NeT

Requirements for KM3NeT Quantum Efficiency at 404 nm : 32% min. Inhomogenity of cathode response : 10% max. Supply Voltage : 1400 V max. Gain : 5E+06 Dark count rate at 15 degree C : 3 kHz max. Transit Time Spread : 2 ns max. (sigma) => 4.7 ns max. (FWHM) Peak to valley ratio : 3.0 min. Length : 105 mm max. Effective area : 72 mm diameter min. Convex input window : 198 mm radius Price : Cheap Production capability : High

Hamamatsu 3 inch PMTs R6233R6091

Hamamatsu 3 inch PMTs ParameterRequirementR6233R6091 QE32% min. at 404 nm 30% typ. at peak 26% typ. at peak Gain5 x x 10 5 typ.5 x 10 6 typ. TTS (FWHM)4.7 ns max.12.2 ns typ.2 ns typ. Effective area (Diameter) 72 mm min.70 mm min.65 mm min. Length105 mm max.87 mm +/- 1 mm137 mm +/- 2mm PriceCheap Not Cheap Mass ProductionPossible Not Possible Need to improve! Important!

3 inch PMT Development R (Standard)R MOD Number of Dynode Stages 8 Stages => 10 Stages Window Shape Flat => Concave-Convex Outer : R198

R MOD Test Result TTS => slow Effective area => small Gain => low

Effective area => large New 3 inch PMT Development Electrodes need to be changed. Shape of Glass bulb needs to be changed. PMT has to be cheap and has to be suitable for mass production. TTS => fast Gain => high

3 inch PMT Development R (Standard)R MODR12199 (New!)

New 3 inch PMT Development 80 mm +/-2 mm 97 mm +/-2 mm Type Number : R12199 Window Shape : Concave-Convex Window Material : Borosilicate Glass Photocathode Material : Bialkali Number of Dynode Stages : 10 Outer Diameter : 80 mm Length : 97 mm

R12199 Quantum Efficiency Need to improve! Preliminary

R12199 Uniformity (X-Axis) Preliminary

R12199 Uniformity (Y-Axis) Preliminary

R12199 Pulse Height Distribution Preliminary

R12199 Transit Time Spread Preliminary

R12199 Time Response Preliminary 1250 V 3.6 ns 3.3 ns 6.2 ns 5.4 ns 7.2 ns 6.0 ns

R12199 Characteristics ParameterRequirementR12199 QE32% min. at 404 nm % at peak Gain5 x x 10 6 TTS (FWHM)4.7 ns max.3.5 – 4.5 ns Effective area (Diameter) 72 mm min.74 mm. P/V ratio3 min.3 Dark Count3000 max.To be measured Length105 mm max.97 mm +/- 1 mm PriceCheap Mass ProductionPossible Preliminary

R12199 Development -We are now trying to find optimal production condition for R12199 (New 3 inch PMT). - Samples will be available soon.

Tentative Delivery Schedule

3. Development of 12 inch PMT

8 inch10 inch 13 inch 20 inch Large Format PMT Lineup We have 13” Between 10” and 20”. It has Metal Flange (special part). Limited production rate & higher cost !! It’s necessary to have a similar size of PMT with conventional structure for less cost and mass-production. => 12-inch PMT was developed !! Metal Flange 26

10 inch R inch R11780 Φ253 mm 12-inch PMT has larger effective area ratio. Φ305 mm RoundShape MushroomShape Higher Pressure-resistance Φ220 mm Φ280 mm Comparison of Dimension between 10-inch and 12-inch PMT 27 Diff.=33 mm Diff.=25 mm Comparison between R11780 & R7081 Effective Area: 1.62 Price: less than 1.5 “Price per unit area” is lower than R7081.

Items R inch PMT R inch PMT Diameter305 mm253 mm Effective Area280 mm min.220 mm min. Effective Area Ratio84.3%74.6% Tube Length385 mm300 mm DynodesLF/10-stage GAIN 1.0E+07 at2000V 1.0E+07 at 1500V T.T.S. (FWHM)2.7 ns 2.9 ( 3.4 ) ns P/V Ratio ( 2.8 ) Dark Counts10,000 cps7,000 cps Comparison of Characteristics 28

R11780 Ebb & Dark Counts Samples: 43 tubes Dark Counts at Ebb (1E+07) Average: 10.6 kcps STDEV: 5.6 kcps Min.: 2.0 kcps Max.: 30.5 kcps Ebb for Gain of 1E+07 Average: 1890 V STDEV: 157 V Min.: 1660 V Max.: 2320 V Percentage of these tubes could be reduced in future. 2000V 10 kcps 29

R11780 TTS & PV Ratio PV Ratio at Ebb (1E+07) Average: 3.00 STDEV: 0.48 Min.: 1.70 Max.: 3.90 TTS at Ebb (1E+07) Average: 2.70 ns STDEV: 0.16 ns Min.: 2.35 ns Max.: 3.13 ns Samples: 43 tubes 2.7 ns

R11780 QE Improvement High QE Trials Standard Low QE was observed at the beginning of trial production. Improvement effort was made from Apr We called it High QE trials. As a result, QE becomes better. 31

R11780 QE CURVES High QE Trials Standard Average QE at 380 nm HQE Trials : 30.7 % (27 tubes) Standard : 22.8 % (10 tubes) 32

R11780 Further Improvement QE has to be improved further. R7081-HQE select : QE = 32 % min. at 380nm R11780-HQE Trials: QE = 30.7 % ave. at 380nm After Pulse is larger than our expectation. R11780 standard : 10% (0.1~16u sec) R11780-HQE Trials : 15% (0.1~16u sec) R7081: 2% (0.1~16u sec) Those characteristics can be improved with suitable production conditioning, especially in the activation process. 33

High QE Bialkali Photocathode

Definition of SBA/UBA R9880 New TO-8 type Metal Package R7600/R inch Square Metal Package

R11780 with 17” Glass Sphere R inch PMT Some space for divider 17-inch Glass Sphere

R11780 PHD and TTS Dark Counts 10K cps typ. TTS (FWHM) 2.7 ns typ. P/V ratio 3.0 typ. Prime features of R11780

R11780 Uniformity

R11780 Waveform (Rise Time) RISE TIME: 4 ns Transit Time: 70 ns Supply Voltage: 2000V

R11780 Gain vs Voltage 1E+07 at 2000V