HCII2007-ACI2007-BCI Workshop Beijing, China, July 23, 2007 Development of a Hybrid EEG Sensor Array for Brain-computer Interfaces Leonard J. Trejo, Ph.D.

Slides:



Advertisements
Similar presentations
ACI/HFES, Baltimore, October 1-3, 2007 Sponsored by US Army Research Office SBIR Phase II: Wearable Physiological Sensor Suite For Early Detection Of Cognitive.
Advertisements

ENGN Engineering Design
PLS’09 Beijing, China, September 7, 2009 Sponsored by US Army Research Office STIR: Advanced Estimation of Cognitive Status Contract No. W911NF-08-C-0121.
MIAMI Research Group Electrical and Computer Eng. Dept. MIAMI Medical Instrument Analysis and Machine Intelligence
Semi-invasive biopotential & activity in rodents.
Augmented Cognition International, San Francisco, October 16, 2006 Novel Hybrid Sensors for Unobtrusive Recording of Human Biopotentials Robert Matthews,
IntroductionMethods Participants  7 adults with severe motor impairment.  9 adults with no motor impairment.  Each participant was asked to utilize.
Brain-computer interfaces: classifying imaginary movements and effects of tDCS Iulia Comşa MRes Computational Neuroscience and Cognitive Robotics Supervisors:
Differential Amplifier
Visualization of dynamic power and synchrony changes in high density EEG A. Alba 1, T. Harmony2, J.L. Marroquín 2, E. Arce 1 1 Facultad de Ciencias, UASLP.
NeuroPhone: Brain-Mobile Phone Interface using a Wireless EEG Headset Source: MobiHeld 2010 Presented By: Corey Campbell.
Poster Design & Printing by Genigraphics ® Leonard J. Trejo, Ph. D. Roman Rosipal, Ph. D Pacific Development and Technology, LLC Paul L.
Introduction The aim the project is to analyse non real time EEG (Electroencephalogram) signal using different mathematical models in Matlab to predict.
Artifact (artefact) reduction in EEG – and a bit of ERP basics CNC, 19 November 2014 Jakob Heinzle Translational Neuromodeling Unit.
1 Affective Learning with an EEG Approach Xiaowei Li School of Information Science and Engineering, Lanzhou University, Lanzhou, China
TRADING OFF PREDICTION ACCURACY AND POWER CONSUMPTION FOR CONTEXT- AWARE WEARABLE COMPUTING Presented By: Jeff Khoshgozaran.
EEG Machine By The All-American Boys Featuring Slo- Mo Motaz Alturayef Shawn Arni Adam Bierman Jon Ohman.
Discussion Section: Review, Viirre Lecture Adrienne Moore
BCI Systems Brendan Allison, Ph.D. Institute for Automation University of Bremen 6 November, 2008.
Electromyography: Recording D. Gordon E. Robertson, Ph.D. Biomechanics Laboratory, School of Human Kinetics, University of Ottawa, Ottawa, CANADA.
At-Home Sleep Staging Device Progress Presentation Presented by: Kiron Sukesan Team Members: Matthew Hwang, Yinong Wang Clients: Dr. Lucey and Dr. Ju Mentor:
Emotion Recognition using the GSR Signal on Android Devices Shuangjiang Li.
Normalization of the Speech Modulation Spectra for Robust Speech Recognition Xiong Xiao, Eng Siong Chng, and Haizhou Li Wen-Yi Chu Department of Computer.
Artifacts In Wearable Photoplethysmographs During Daily Life Motions and Their Reduction With Least Mean Square Based Active Noise Cancellation Method.
NeuroPhone : Brain-Mobile Phone Interface using a wireless EEG Headset Ilho nam.
ERP DATA ACQUISITION & PREPROCESSING EEG Acquisition: 256 scalp sites; vertex recording reference (Geodesic Sensor Net)..01 Hz to 100 Hz analogue filter;
Home Health Care and Assisted Living Professor John A. Stankovic Department of Computer Science University of Virginia.
SoundSense by Andrius Andrijauskas. Introduction  Today’s mobile phones come with various embedded sensors such as GPS, WiFi, compass, etc.  Arguably,
Design and Development of a Personal Trainer System Progress Presentation by Emer Bussmann.
1. 2 Abstract - Two experimental paradigms : - EEG-based system that is able to detect high mental workload in drivers operating under real traffic condition.
MARS: A Muscle Activity Recognition System Enabling Self-configuring Musculoskeletal Sensor Networks IPSN 2013 NSLab study group 2013/06/17 Presented by:
Noise Canceling Headphones Team Members Doan Thanh Khiet Tran Jasmine Khadem Kalina Guentcheva.
Application of non-linear Wavelet De-noising
 An eye tracking system records how the eyes move when a subject is sitting in front of a computer screen.  The human eyes are constantly moving until.
EWatch: A Wearable Sensor and Notification Platform Paper By: Uwe Maurer, Anthony Rowe, Asim Smailagic, Daniel P. Siewiorek Presenter: Ke Gao.
Last lecture: Design Standards for biomedical devices Device Certification File Formats and Data Transfer Standards.
IntroductionMethods Participants  7 adults with severe motor impairment performed EEG recording sessions in their own homes.  9 adults with no motor.
Automatic Gain Control Response Delay and Acquisition in Direct- Sequence Packet Radio Communications Sure 2007 Stephanie Gramc Dr. Noneaker.
1 Methods for detection of hidden changes in the EEG H. Hinrikus*, M.Bachmann*, J.Kalda**, M.Säkki**, J.Lass*, R.Tomson* *Biomedical Engineering Center.
Graz-Brain-Computer Interface: State of Research By Hyun Sang Suh.
EEG Biofeedback Device Ashley Anderson, Michelle Lorenz, Shikha, Ryan Thome, Chris Wegener Client: Dr. Daniel MullerAdvisor: John Webster.
ICRA2009 Evaluation of a robot as embodied interface for Brain Computer Interface systems E. Menegatti, L. Tonin Intelligent Autonomous System Laboratory.
Frequency-response-based Wavelet Decomposition for Extracting Children’s Mismatch Negativity Elicited by Uninterrupted Sound Department of Mathematical.
1 Distribution Statement “A” (Approved for Public Release, Distribution Unlimited)5/15/2012 Advanced Radio Frequency Mapping (RadioMap) Dr. John Chapin.
EECE 252 PROJECT SPRING 2014 Presented by: Peizhen Sun Nor Asma Mohd Sidik.
Scaling to several dancers… High Speed Sensor Fusion Vocabulary of features Capacitive proximity to 50 cm 6-axis IMU - 1 Mbps TDMA radio 100 Hz Full State.
Analysis of Movement Related EEG Signal by Time Dependent Fractal Dimension and Neural Network for Brain Computer Interface NI NI SOE (D3) Fractal and.
FREQUENCY-TAGGING EEG TEST FOR MEASURING SPATIAL ATTENTION IN QIGONG RESEARCH Howe Lin* §¶, Andrew Schneider #, Ramesh Srinivasan +§, and Shin Lin* §¶.
BCI I: EEG-Based Cognitive Status Monitoring Scott Makeig & Tzyy-Ping Jung University of California San Diego November 13, 2007.
What is EEG ? An electroencephalograph (EEG) is the recorded electrical activity generated by the brain. In general, EEG is obtained using electrodes placed.
Principal components analysis (PCA) as a tool for identifying EEG frequency bands: I. Methodological considerations and preliminary findings Jürgen Kayser,
Prototype Sensor Status and Measurements u Sensor Response Measurements u Mechanical Response u Noise Expectations u DAQ Status.
Feel the beat: using cross-modal rhythm to integrate perception of objects, others, and self Paul Fitzpatrick and Artur M. Arsenio CSAIL, MIT.
HOT CAR BABY DETECTOR Group #20 Luis Pabon, Jian Gao ECE 445 Dec. 8, 2014.
Wearable health systems: from smart technologies to real applications Lymberis A, Gatzoulis L European Commission, Information Society and Media Directorate-
GridEEG – User training
[Ran Manor and Amir B.Geva] Yehu Sapir Outlines Review
Robert Lahmann VLVnT – Toulon – 24-April-2008
* the sampling rate and filter bandwidth were set to 500Hz and 1-10 Hz, respectively. * an additional 60Hz notch filter was employed to avoid the power-line.
Adaptive Automation NINA project
Neurofeedback of beta frequencies:
When to engage in interaction – and how
Brain Interface Design for Asynchronous Control
Volume 69, Issue 3, Pages (February 2011)
How to Build Smart Appliances?
Perceptual Echoes at 10 Hz in the Human Brain
Progress Seminar 권순빈.
Machine Learning for Visual Scene Classification with EEG Data
Anh Nguyen, Raghda Alqurashi, Zohreh Raghebi
Feature Selection in BCIs (section 5 and 6 of Review paper)
Presentation transcript:

HCII2007-ACI2007-BCI Workshop Beijing, China, July 23, 2007 Development of a Hybrid EEG Sensor Array for Brain-computer Interfaces Leonard J. Trejo, Ph.D. Quantum Applied Science and Research International Workshop on Brain-Computer Interface Technology and Second BCI2000 Workshop Beijing, China, July 23-24, 2007

HCII2007-ACI2007-BCI Workshop Beijing, China, July 23, 2007 Research Team Robert Matthews Neil McDonald Harini Anumula

QUASAR Breakthroughs in Sensor Technology for Applications from Minerals to Medicine

Our Vision for Brain-Computer Interaction Truly deployable unobtrusive biosensors –Nearly invisible to the user –Seamlessly integrated with clothing and appliances End-to-end systems for operational biosensing –Broad application spectrum (e.g., EEG, EOG, ECG and EMG) –Low-power, long lasting, wireless electronics –Robust algorithms tolerant of noise and sensor dropout –Intelligent systems adapt for situational or individual differences Focus of this presentation: Hybrid EEG Sensors NO ADHESIVES NO WIRES NO PREP NO GELS

Barriers to Truly Deployable EEG Sensors Large common mode signals Frequent user motion will generate signal artifacts Sensor harness physicality issues –Lack of user compliance –Possible incorrect application of sensors –Fitting sensors into wearable garments –Variability over subjects –Hygiene Battery power issues Size and weight issues Long-term usability and reliability

QUASAR EEG Sensor Technologies QUASAR Capacitive sensors (on skin EEG, EOG, ECG) QUASAR Next Gen sensors (standoff detection) QUASAR Hybrid sensors (through hair) Validation Studies Completed Fingers

Pros and Cons of Current EEG Sensors Conductive sensors –Generally good signal quality, low noise –Most require some skin preparation –Produce skin irritation and risk of infection –Micro- or nano- needle sensors break off and remain in skin –Cannot be worn for extended periods of time (electrode drying) Capacitive sensors –Sensitive to static charges, stray E-fields, and motion artifacts –No skin preparation, electrolyte drying or skin irritation

Hybrid EEG Biosensors (the best of both worlds) Capacitive QUASAR (IBE) EEG sensors –Presently record high-quality EEG signals on bare skin –Through-hair EEG sensing is not currently feasible –Through-hair will be feasible with next-gen technology Advanced QUASAR capacitive sensors systems make new hybrid EEG sensor technology possible –Hybrid sensors use ultra high resistive contact in conjunction with capacitive contact –Hybrid sensors do not modify or invade the skin and consequently do not cause skin irritation –Hybrid sensors are a new option for wearable EEG arrays

Deployable EEG/EOG Sensor Concepts QUASAR Hybrid EEG Electrodes Audio Headset EOG/EEG Glasses QUASAR Capacitive Electrodes

Initial Hybrid Sensor Demo (3/2006) QUASAR and wet electrode in the C z position – filtered in 5-15 Hz bandwidth Test set up – standard electrode positions Correlation between two sensors Trial for an outside entity Sensor used (old) New sensor

Four HCI contexts tested with side-by-side “wet” electrodes and QUASAR Hybrid EEG sensors 1.Baseline: Eyes Open/Closed (desynchronization of EEG alpha rhythm) –30 s open / 30 s closed; repeated 3x over session 2.Real/Imaginary Button-press (desynchronization of EEG  -Rhythm) –Reach and press key on keyboard; repeat with imaginary motion 3.Visual Oddball (modulation of P300 ERP component) –Count the number of visual targets (row or column of matrix) 4.Memory/Cognition (modulation of EEG alpha and theta rhythms) –Count backwards from 100 by ones or sevens for 60 s All conditions: recorded Fz, C3, Cz, C4, referred to right ear Ag-AgCl disc electrodes, QUASAR IBE, and hybrid sensors

QUASAR Headband System

EEG Eyes Open/closed: Correlation of Signals over 30-s Long Segments Eyes-closed EEG task, signals normalized to zero mean and unit standard deviation, displaced vertically to allow comparisons. From the top down: QUASAR Cz, wet Cz, QUASAR Fz, wet Fz, QUASAR C3, wet C3, EOG, and ECG. Red and blue lines are for the QUASAR sensor and wet electrode recordings, respectively.

EEG Eyes Open/closed: Distribution of Correlation Coefficients for 1-s Segments Histogram of correlations over consecutive 30 1-s segments for QUASAR Fz - wet Fz. In 26/30 segments the QUASAR-wet correlation was 0.80 or higher. EEG signal band-limited to 0-40 Hz.

EEG Eyes Open/closed: Correlations of Power Spectra. Power spectral density functions of 30-s EEG recordings during eyes-closed session and following eyes-open session (Welch’s method, window = 2 s, overlap = 1 s, FFT length = 1024, sampling rate = 100 Hz). QUASAR-Wet Correlations Eyes closed: Eyes open:

Button-press Tasks: Sample Power Spectra (Hybrid Sensors only). PSDs EEG recordings at Cz during button-press (60 s), imaginary button-press (60s), and eyes-open tasks (30 s). Pearson r values for QUASAR-wet sensor pairs at Cz, Fz, and C3 ranged from to

Counting tasks: Sample Power Spectra PSDs of 30-s EEG recordings during easy and hard levels of counting task. Easy-hard spectral differences appear in the theta (4-7), alpha (8-12), and SMR (14-16 Hz) bands of the EEG spectrum. Inter-sensor correlations between QUASAR and wet sensors at Cz in the easy and hard conditions were and , respectively. r =.9993 r =.9987

Visual Oddball Task: Sample ERP Averages Oddball (P300) Task: count deviant stimulus (row or column; P = 1/7) Post-stimulus Time (ms)

QUASAR hybrid sensor EEG signals correlate extremely well with simultaneously recorded wet electrodes. –QUASAR – wet sensor correlations in the time domain were typically at 0.8 or better (interchannel correlations of wet sensors ranged from ) –Correlations of QUASAR - wet frequency spectra within the EEG band of 0-40 Hz were typically above QUASAR hybrid sensors can gauge EEG important for AugCog & HCI –modulation of EEG rhythms, such as alpha, theta, and SMR –detection of P300 ERPs for discrete stimuli Conclusions from Sensor Tests

Development of an Integrated Neurocognitive Sensor Array Through clothing ECG On skin EOG On skin EEG Through hair EEG sensor Algorithms to classify even in noisy environments Fully deployable Bio monitoring system Data Acquisition Sensor Suite AUGCOG & others Aberdeen SBIR Fully Deployable Bio monitoring system Unfunded Sensor Harness Phase II program

QUASAR-Wadsworth NIH SBIR Project (2008)

Specific Aims Design a dry EEG sensor array and amplifier system tailored for use as a new front-end for the existing brain-computer spelling system. Show that the existing brain-computer interface can operate effectively with the new sensor array as the front end. Compare the dry EEG sensor array to the standard wet electrode array in eight able-bodied human subjects who will operate the brain-computer interface speller in a controlled experiment. Ensure that the dry EEG sensor array is easy to apply and comfortable when worn for an extended period of time.

Specific Aims (cont’d) Using standardized rating scales, we will compare the comfort of the dry EEG sensor array with the existing wet EEG electrode array. Perform controlled experiments and administer a battery of questionnaires regarding the two systems pre- and post-test. Our hypotheses are that a) subjects’ perceived comfort of the dry EEG sensor array matches or exceeds the comfort of the existing wet EEG sensor array, b) that subjects’ self-reported mood during sessions performed with the dry EEG sensor array, matches or is improved over subjects’ self-reported mood during sessions performed with the existing wet EEG sensor array.

10-Channel EEG Prototype DAQ Module 10 channel EEG Ultra low power (2 days on 2 AA batteries) Over 80dB common mode rejection Up to 1kHz sample rate Advanced Wireless A/D System

Wireless Device uC + Radio (nRF24E1) 50 ohm Matching Network Regulator (LTC ) Chip Antenna (AN9520) Dual MOSFET (NTHD4508N ) Tri-Axial Accelerometer + Temp Sensor (H34C) Interface Flex. PCB High bandwidth device low power optimized for duty cycling

Algorithm Development* On-line classifier using adaptive KPLS feature extraction and adaptive classification networks −Can adapt for individual or situational differences in features and feature mappings −Applications tested: − On-line cognitive fatigue assessment (3.5 s update rate) − Multimodal real-time advisory system for human-automation reliability (2 s update rate) − Brain-computer interface (2 s update rate) Basic advances in signal processing (denoising, kernel methods, software/hardware artifact removal) *QUASAR & Partners: NASA, Pacific Development & Technology

Real-time EEG/Mental State Classifier

PLS Algorithm in BCI Moving Map Application (2005)

EEG-based Classification with Low-density Arrays or Low-SNR Signals Robust algorithm applied to mental fatigue classification using multichannel EEG spectra Trained KPLS-DLR classifier in Air Force pilots using 19 electrodes Corrupted signal from SNR of 0 dB to -18 dB Reduced density from 19 to 4 electrodes Preserved >80% accuracy with -9 dB SNR and four electrodes

Multimodal Assessment of Cognitive Overload EEG Probe ERP ECG Cognitive overload algorithm Real-time alert or advisory signal KPLS-LDA classification of 20-ch EEG spectra from 2-s epochs