OVERVIEW OF PMSB INCINERATOR PLANT 1.Primary Chamber 3.Secondary Chamber 4.Heat Exchanger 5.Cooling Tower 7.Rotary Contactor 8.Fabric Filter 9.ID Fan 10.Stack.

Slides:



Advertisements
Similar presentations
Oxidation (Incineration)
Advertisements

Furnaces also called Fired Heaters
MEASURES TO REDUCE NO x EMISSIONS M. Sc. Engineering Policy and Technology ManagementEnergy Management and Policy Por: Miguel Leocádio João Meyer MEASURES.
Energy Efficient Process Heating. Energy Balance on Furnace.
In India 65% of total power is generated by the Thermal Power Stations. Main parts of the plant are 1. CHP.
Heating Control Devices
Fuel System 13 April
Progress in Ca-based CO 2 capture research at Cranfield University Ondřej Mašek, Adina Bosoaga, John Oakey.
Liquid Fuel Burners Oils may be burnt in two ways  it is vaporized before ignition so that it burns like a gas (vaporising burners)  it is converted.
Thermal Power Station Plant. Introduction 150 MW Thermal power station plant, produce 450t/hr steam at full load The max steam pressure is 150 bar with.
THERMAL POWER PLANT.
Pharos University جامعه فاروس Faculty of Engineering كلية الهندسة Petrochemical Department قسم البتروكيماويات PE 330 ENERGY CONSERVATION LECTURE (8) FURNACES.
Control of Sulfur Oxides Dr. Wesam Al Madhoun
European Commission Enterprise and Industry GReening business through the Enterprise Europe Network Linking energy efficiency with environmental protection.
Air Pollution Chapter 5.
Overview: Hazardous Waste Combustion. What is Hazardous Waste? Definition of Hazardous Waste –Hazardous wastes are distinguished from other wastes by:
Engine Systems and Components
Group Meeting #1 January 29 th, 2013 Michael Bentel Jeremy David Erik Peterson Arpit Shah 1.
Industrial Ventilation - A major control measure Dr. AA, UTM.
Steam Power Plant.
Coal Burning System.
Vehicle pollution control
Thermal energy Ch. 6 mostly. Transferring thermal NRG There are three mechanisms by which thermal energy is transported. 1. Convection 2. Conduction 3.
Air Cleaning Devices. 2 Is An Air Cleaner Needed ?  Toxicity of materials discharged  Amount of material to be discharged  Value of material to be.
Lesson 7 Steam Power Plant.
FUEL OIL SYSTEM. 1.FUEL OILS 1.H.F.O. Heavy fuel oil ( residual, blends & crudes ); 2.D.F.O. Diesel fuel oil or M.D.O. Marine Diesel oil or light fuel.
B OILER Presented by: Muhammad Azffar Mohamad Hanif bin Yusof Nor Aminah bt. Mohd Khalil
Gas Turbine Power Plant
Multi-Stage Flash Desalination (MSF)
1 Combustion Oil Fired Equipment. 2 OIL Combustion of oil fired equipment has the same basics of gas. Remember, Oil is a liquid and this must be converted.
Heat Exchanger & Classification Prepared by: Nimesh Gajjar
Plant Utility System (TKK-2210) 14/15 Semester 4 Instructor: Rama Oktavian Office Hr.: M-F
Gas Turbine Theory and Construction
Lecture Objectives: Continue with power generation Learn basics about boilers and furnaces.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
INCINERATION  Define as: Control process for burning solid, liquid and gaseous combustible wastes to gases and residue containing non- combustible material.
FIGURE 12-1 Excess air temperature curve.. FIGURE 12-2 HCl/Cl2 equilibrium.
Fives FICEM APCAC – XXIX Congreso Técnico – Costa Rica - San José – 05/09/2012 Driving Progress The Fives FCB sustainable cement plant.
Heating of the Atmosphere
Design Analysis of Furnace Of A Steam Generator P M V Subbarao Professor Mechanical Engineering Department Perfection of Primary Cause for All that Continues…..
1 HVACR215 – Mechanical for Oil Oil Combustion. 2 Combustion The burning of a substance. Rapid Oxidation The burning of a substance. Rapid Oxidation.
◦ A change in state from a solid to a liquid occurring at a specific temperature.
I.C. ENGINES LECTURE NO: 08 (24 Mar, 2014). Combustion Formulas Combustion is a chemical reaction in which certain elements of the fuel combined with.
Welcome PRESENTATION BY ASHISH MISHRA.
STEAM POWER PLANTS.
A seminar on Practical Training taken at KOTA SUPER THERMAL POWER STATION.
Thermal Power Station.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
General Requirements for a burner  Mixture of fuel with primary air should be within the limits of inflammability  Flame stability should be maintained.
Atomic Absorption Spectroscopy
Using Thermal Energy Mrs. Nell 8 th Grade Physical Science Chapter 6 Review.
AIR POLLUTION. Pollutants VOCs=volatile organic compounds: chemicals used to manufacture and maintain building materials, interior furnishing, cleaning.
1Korea University of Technology and Education 2 Generation Common Rail VGT Variable Swirl 32Bit Computer Elec. Controlled EGR Flap C P F Electronically.
The C.I. Engines Fuel System  The C.I. engine demands that the fuel supplied is –  Timed to inject when the piston is near the end of the compression.
Thermal power plant , panipat
Energy Balance across pulverizer is very critical for satisfactory
Unit 13 Oil-Burning Equipment
Intake & Exhaust Components
Golden Isles Conservation Center
Fulfilled the student of group ФЭ14-01B Zhuk Aleksey
Control of Sulfur Oxides Dr. Wesam Al Madhoun
PERFORMANCE ANALYSIS OF COMBUSTION SYSTEMS
Catalytic Converter and Computer Controlled Emissions
Ch. 10 Heat Transfer in Engines
INCINERATION.
Furnaces (also called Fired Heaters)
OPTIMIZATION OF EXCESS AIR IN COAL FURNACE
Feed Water Treatment for Steam Power plant
OPTIMIZATION OF EXCESS AIR IN COAL FURNACE
Presentation transcript:

OVERVIEW OF PMSB INCINERATOR PLANT 1.Primary Chamber 3.Secondary Chamber 4.Heat Exchanger 5.Cooling Tower 7.Rotary Contactor 8.Fabric Filter 9.ID Fan 10.Stack Outlet 6.Lime & Carbon Feeder 2.Burners Process

BACK DOOR ASH PUSHER Primary chamber The 3 hydraulically operated rams slowly pushed ash through PC depositing ash on the burnout hearth Gaseous product from incomplete combustion discharged from PC are passed into ignition chamber. WASTE BURNED INTO ASH

Pyrolised gases produced are mixed with excess oxygen and completely combusted with temperature of 1100°C in the secondary chamber. The min. residence time in secondary chamber is 2 seconds. The exhaust gases at 1100°C will pass into a heat exchanger and adiabatic gas quench, which reduces the temperature. Secondary chamber

Downpass HE needed to provide preheated combustion air Ceramic tubed HE : to provide hot air for exhaust gas reheat whilst cooling the exhaust gas stream It cannot be let to thermal shock and must clean the HE using compressed air lance through access doors Heat Exchanger CERAMIC TUBE

Its function is to cool the exhaust gases to a acceptable temperature for entry to FF The exhaust gases are contacted with finely atomized water droplets Nozzle use compressed air to ensure the cooling water is finely atomized where liquid evaporated upon contact with hot gases Cooling Tower

Rotary Contactor Lime and carbon contacted quencher outlet gas in rotary contactor Hydrated lime and activated carbon pneumatically injected into drum Fine particle entrained with gas stream whilst the larger one will retain within ball mill Lime and carbon also help to neutralized the gases and trapped larger particles

Also called ‘stoking’ because its function is to trapped any larger particle before gas emission to open space Reactants injected into FF and foam coating in all surfaces Additional contact of exhaust gases through reactants completes the neutralization process Cold spots always occur on the FF casing Fabric Filter FILTER BAG

Provide the energy necessary to overcome the considerable resistance to gas flow in APC Plant It is like ‘heart’ to APC Plant Equipped with vibration sensor to detect any excess vibration Induced Draft Fan

Cleaned incinerator exhaust gases discharged from APC plant through stack at height 20 m above ground level Equipped with test ports and access platform to permit emission testing Exhaust Stack

Burners The incinerator is equipped with a PC ignition burner and 2 SC dual fuel burners PC burner ignites the waste material SC burners maintain desired temperature to burn the pyrolised gas Other parameters i.e O2, CO and CO2 must be monitored to the combustion efficiency BURNERS BURNER AIR FAN