OSHA Office of Training & Education1 Electrical Safety - Construction.

Slides:



Advertisements
Similar presentations
Electrical Safety.
Advertisements

OSHA Region 1 Cooperative and State Programs Electrical Training/Inspection “Roll Up” Extension Cords GFCIs Power tools.
Electrical Safety 1926 Subpart K ‑ Electrical
Electrical Safety Program. How Electricity Works Operating an electric switch is like turning on a water faucet. Behind the faucet or switch there must.
OSHAX.org - The Unofficial Guide To the OSHA
OSHA Office of Training and Education - Revised by TEEX 12/05/07
Electrical Subpart S This presentation is designed to assist trainers conducting OSHA 10-hour General Industry outreach training for workers. Since workers.
Electrical Safety.
Workplace Electrical Safety Training BIDMC EOC 64 and EOC 17 Policy
Electrical Safety 29 CFR I. Background for the Trainer:
CHEM 521 Safety Presentation. Hazard Symbols You Must Know.
By: Aseem Aggarwal. Causes of Electrocution Fatalities Contact with Overhead Power lines Contact with Live Circuits Poorly Maintained Extension Cords.
OSHA Office of Training and Education
Young Worker Safety Resource Center, adapted from OSHA Office of Training and Education Electrical Safety.
Electrical Safety Awareness Un-Qualified
ELECTRICAL SAFETY Safety Training for the Non-Qualified.
OSHA Office of Training and Education
Electrical Safety - Construction
 Recognize the scope and structure of the OSHA standards.  Identify the common electrical hazards in long term care settings.  Discuss electrical safety.
Systems of Safety Applied to Focus Four Hazards USDOL-OSHA Susan Harwood Grant SHT21005SH0.
Occupational Safety and Health Course for Healthcare Professionals.
Union College EHS Training 1 Electrical. 2 Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical.
Electrical Safety 29 CFR Concerned About Electricity? How many sets of Christmas lights do you plug into one extension cord? Do you still use.
Electrical Safety Program
Hazard - Inadequate Wiring
Electrical Safety - Construction. Electricity - The Dangers About 5 workers are electrocuted every week Causes 12% of young worker workplace deaths Takes.
Electrical Safety - Construction
Purpose Power lines Equipment Assured Grounding GFCI Conclusion.
BUILDING TRADE SAFETY ELECTRICAL SAFETY.
Electrical Safety Safety Training Series
Safety Training For The Non-Qualified
ELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S
ADVANCED ELECTRICAL SAFETY AWARENESS February 9, 2008 Guest Palace Hotel Doha, Qatar Engr. Amado B. Taduran Philippine Association of Safety Engineers.
Electrical Safety.
Electrical Safety INSTRUCTOR’S NOTES:
Electrical Safety. Defective Insulation To protect you, electrical wires are insulated by a plastic.
Electrical Safety Training
Electrical Safety Preventing Electrical Shock. Shocking Statistics!  1,200 Industrial Fatalities Per Year  1 of 30,000 Accidents in General is Fatal.
Electrical This presentation is designed to assist trainers conducting OSHA 10-hour General Industry outreach training for workers. Since workers are.
Electrical Safety INSTRUCTOR’S NOTES:
ELECTRICAL HAZARDS Electricity is an essential of modern life Some work directly with electricity (Engineers, circuit assemblers) Some work indirectly.
1 Electrical Safety. 2 Electrical Hazards & OSHA 29 CFR (b)(1) requires: “Electrical equipment shall be free from recognized hazards that are.
Electrical Safety INSTRUCTOR’S NOTES:
Creating and Implementing the Absorb-Type Activity: “Electrical Hazards” Robert L. Czewski Ashford University – Online EDU652 Instructional Design and.
Electrical Safety.
Electrical Safety in Construction. Objectives In this course, we will discuss the following: Common electrical hazards Standards relating to those hazards.
Copyright  Progressive Business Publications Electrical Safety.
1 Electrical. 2 Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:  Electrocution.
Electricity. Electricity Electric shock happens when a person becomes part of an electrical circuit and the current flows through their body. When an.
1a.  Exposed part  Live or energized part  De-energized part 1a.
Electrical Safety Electrical Injuries Hazards Protective Measures.
1 Electrical Safety This material was produced under grant number SH F-18 from the Occupational Safety and Health Administration, U.S. Department.
Electrical Safety, Subpart K
Electrical. Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical injuries: –Electrocution.
1 AS OF:141330DEC15 UNCLASSIFIED OPR: 8A 8A Safety Electrical Safety Awareness Training Note: This training meets the General Electrical Safety Awareness.
ELECTRICAL SAFETY. OSHA Office of Training & Education Electrical Safety.
CHEM 421 Safety Presentation. Hazard Symbols You Must Know.
Electrical Safety OSHE 382, Spring 2016
Electrical Safety OSHE 112, Spring 2016
ELECTRICAL SAFETY! It’s shocking! OSHA 29 CFR
OSHA Office of Training and Education
Electrical Safety.
Personal Protective Equipment
Electrical Safety Review Compliance Assistance Region IV
Electrical Safety.
OSHA Office of Training and Education
OSHA Office of Training and Education
OSHA Office of Training and Education
OSHA Office of Training and Education
OSHA Office of Training and Education
Presentation transcript:

OSHA Office of Training & Education1 Electrical Safety - Construction

OSHA Office of Training & Education2 Electricity - The Dangers About 5 workers are electrocuted every week Causes 12% of young worker workplace deaths Takes very little electricity to cause harm Significant risk of causing fires

OSHA Office of Training & Education3 Electricity – How it Works Electricity is the flow of energy from one place to another Requires a source of power: usually a generating station A flow of electrons (current) travels through a conductor Travels in a closed circuit

OSHA Office of Training & Education4 Electrical Terms Current -- electrical movement (measured in amps) Circuit -- complete path of the current. Includes electricity source, a conductor, and the output device or load (such as a lamp, tool, or heater) Resistance -- restriction to electrical flow

OSHA Office of Training & Education5 Electrical Terms Conductors – substances, like metals, with little resistance to electricity that allow electricity to flow Grounding – a conductive connection to the earth which acts as a protective measure Insulators -- substances with high resistance to electricity like glass, porcelain, plastic, and dry wood that prevent electricity from getting to unwanted areas

OSHA Office of Training & Education6 Electrical Injuries There are four main types of electrical injuries: Direct:  Electrocution or death due to electrical shock  Electrical shock  Burns Indirect - falls

OSHA Office of Training & Education7 Electrical Shock An electrical shock is received when electrical Current passes through the body. You will get an electrical shock if a part of your Body completes an electrical circuit by… Touching a live wire and an electrical ground, or Touching a live wire and another wire at a different voltage.

OSHA Office of Training & Education8 Shock Severity Severity of the shock depends on:  Path of current through the body  Amount of current flowing through the body (amps)  Duration of the shocking current through the body, LOW VOLTAGE DOES NOT MEAN LOW HAZARD

OSHA Office of Training & Education9 Dangers of Electrical Shock Currents above 10 mA* can paralyze or “freeze” muscles. Currents more than 75 mA can cause a rapid, ineffective heartbeat -- death will occur in a few minutes unless a defibrillator is used 75 mA is not much current – a small power drill uses 30 times as much * mA = milliampere = 1/1,000 of an ampere Defibrillator in use

OSHA Office of Training & Education10 Burns Most common shock-related injury Occurs when you touch electrical wiring or equipment that is improperly used or maintained Typically occurs on hands Very serious injury that needs immediate attention

OSHA Office of Training & Education11 Falls Electric shock can also cause indirect injuries Workers in elevated locations who experience a shock may fall, resulting in serious injury or death

OSHA Office of Training & Education12 Electrical Hazards and How to Control Them Electrical accidents are caused by a combination of three factors:  Unsafe equipment and/or installation,  Workplaces made unsafe by the environment, and.  Unsafe work practices.

OSHA Office of Training & Education13 Hazard – Exposed Electrical Parts Cover removed from wiring or breaker box

OSHA Office of Training & Education14 Control – Isolate Electrical Parts Use guards or barriers Replace covers Guard live parts of electric equipment operating at 50 volts or more against accidental contact

OSHA Office of Training & Education15 Control – Isolate Electrical Parts - Cabinets, Boxes & Fittings Conductors going into them must be protected, and unused openings must be closed

OSHA Office of Training & Education16 Control – Close Openings Junction boxes, pull boxes and fittings must have approved covers Unused openings in cabinets, boxes and fittings must be closed (no missing knockouts) Photo shows violations of these two requirements

OSHA Office of Training & Education17 Hazard - Overhead Power Lines Usually not insulated Examples of equipment that can contact power lines:  Crane  Ladder  Scaffold  Backhoe  Scissors lift  Raised dump truck bed  Aluminum paint roller

OSHA Office of Training & Education18 Control - Overhead Power Lines Stay at least 10 feet away Post warning signs Assume that lines are energized Use wood or fiberglass ladders, not metal Power line workers need special training & PPE

OSHA Office of Training & Education19 Hazard - Inadequate Wiring Hazard - wire too small for the current Example - portable tool with an extension cord that has a wire too small for the tool  The tool will draw more current than the cord can handle, causing overheating and a possible fire without tripping the circuit breaker  The circuit breaker could be the right size for the circuit but not for the smaller-wire extension cord Wire Gauge WIRE Wire gauge measures wires ranging in size from number 36 to 0 American wire gauge (AWG)

OSHA Office of Training & Education20 Control – Use the Correct Wire Wire used depends on operation, building materials, electrical load, and environmental factors Use fixed cords rather than flexible cords Use the correct extension cord Must be 3-wire type and designed for hard or extra-hard use

OSHA Office of Training & Education21 Hazard – Defective Cords & Wires Plastic or rubber covering is missing Damaged extension cords & tools

OSHA Office of Training & Education22 Hazard – Damaged Cords Cords can be damaged by:  Aging  Door or window edges  Staples or fastenings  Abrasion from adjacent materials  Activity in the area Improper use can cause shocks, burns or fire

OSHA Office of Training & Education23 Control – Cords & Wires Insulate live wires Check before use Use only cords that are 3-wire type Use only cords marked for hard or extra-hard usage Use only cords, connection devices, and fittings equipped with strain relief Remove cords by pulling on the plugs, not the cords Cords not marked for hard or extra- hard use, or which have been modified, must be taken out of service immediately

OSHA Office of Training & Education24 Permissible Use of Flexible Cords Stationary equipment-to facilitate interchange DO NOT use flexible wiring where frequent inspection would be difficult or where damage would be likely. Flexible cords must not be... run through holes in walls, ceilings, or floors; run through doorways, windows, or similar openings (unless physically protected); hidden in walls, ceilings, floors, conduit or other raceways.

OSHA Office of Training & Education25 Grounding Grounding creates a low- resistance path from a tool to the earth to disperse unwanted current. When a short or lightning occurs, energy flows to the ground, protecting you from electrical shock, injury and death.

OSHA Office of Training & Education26 Hazard – Improper Grounding Tools plugged into improperly grounded circuits may become energized Broken wire or plug on extension cord Some of the most frequently violated OSHA standards

OSHA Office of Training & Education27 Control – Ground Tools & Equipment Ground power supply systems, electrical circuits, and electrical equipment Frequently inspect electrical systems to insure path to ground is continuous Inspect electrical equipment before use Don’t remove ground prongs from tools or extension cords Ground exposed metal parts of equipment

OSHA Office of Training & Education28 Control – Use GFCI (ground-fault circuit interrupter) Protects you from shock Detects difference in current between the black and white wires If ground fault detected, GFCI shuts off electricity in 1/40 th of a second Use GFCI’s on all 120-volt, single- phase, 15- and 20-ampere receptacles, or have an assured equipment grounding conductor program.

OSHA Office of Training & Education29 Control - Assured Equipment Grounding Conductor Program Program must cover:  All cord sets  Receptacles not part of a building or structure  Equipment connected by plug and cord Program requirements include:  Specific procedures adopted by the employer  Competent person to implement the program  Visual inspection for damage of equipment connected by cord and plug

OSHA Office of Training & Education30 Hazard – Overloaded Circuits Hazards may result from: Too many devices plugged into a circuit, causing heated wires and possibly a fire Damaged tools overheating Lack of overcurrent protection Wire insulation melting, which may cause arcing and a fire in the area where the overload exists, even inside a wall

OSHA Office of Training & Education31 Control - Electrical Protective Devices Automatically opens circuit if excess current from overload or ground-fault is detected – shutting off electricity Includes GFCI’s, fuses, and circuit breakers Fuses and circuit breakers are overcurrent devices. When too much current:  Fuses melt  Circuit breakers trip open

OSHA Office of Training & Education32 Power Tool Requirements Have a three-wire cord with ground plugged into a grounded receptacle, or Be double insulated, or Be powered by a low-voltage isolation transformer

OSHA Office of Training & Education33 Tool Safety Tips Use gloves and appropriate footwear Store in dry place when not using Don’t use in wet/damp conditions Keep working areas well lit Ensure not a tripping hazard Don’t carry a tool by the cord Don’t yank the cord to disconnect it Keep cords away from heat, oil, & sharp edges Disconnect when not in use and when changing accessories such as blades & bits Remove damaged tools from use

OSHA Office of Training & Education34 Preventing Electrical Hazards - Tools Inspect tools before use Use the right tool correctly Protect your tools Use double insulated tools Double Insulated marking

OSHA Office of Training & Education35 Temporary Lights Protect from contact and damage, and don’t suspend by cords unless designed to do so.

OSHA Office of Training & Education36 Clues that Electrical Hazards Exist Tripped circuit breakers or blown fuses Warm tools, wires, cords, connections, or junction boxes GFCI that shuts off a circuit Worn or frayed insulation around wire or connection

OSHA Office of Training & Education37 Lockout and Tagging of Circuits Apply locks to power source after de- energizing Tag deactivated controls Tag de-energized equipment and circuits at all points where they can be energized Tags must identify equipment or circuits being worked on

OSHA Office of Training & Education38 Safety-related Work Practices To protect workers from electrical shock:  Use barriers and guards to prevent passage through areas of exposed energized equipment  Pre-plan work, post hazard warnings and use protective measures  Keep working spaces and walkways clear of cords

OSHA Office of Training & Education39 Safety-Related Work Practices Use special insulated tools when working on fuses with energized terminals Don’t use worn or frayed cords and cables Don’t fasten extension cords with staples, hang from nails, or suspend by wire.

OSHA Office of Training & Education40 Preventing Electrical Hazards - Planning Plan your work with others Plan to avoid falls Plan to lock-out and tag- out equipment Remove jewelry Avoid wet conditions and overhead power lines

OSHA Office of Training & Education41 Avoid Wet Conditions If you touch a live wire or other electrical component while standing in even a small puddle of water you’ll get a shock. Damaged insulation, equipment, or tools can expose you to live electrical parts. Improperly grounded metal switch plates & ceiling lights are especially hazardous in wet conditions. Wet clothing, high humidity, and perspiration increase your chances of being electrocuted.

OSHA Office of Training & Education42 Preventing Electrical Hazards - PPE Proper foot protection (not tennis shoes) Rubber insulating gloves, hoods, sleeves, matting, and blankets Hard hat (insulated - nonconductive)

OSHA Office of Training & Education43 Preventing Electrical Hazards – Proper Wiring and Connectors Use and test GFCI’s Check switches and insulation Use three prong plugs Use extension cords only when necessary & assure in proper condition and right type for job Use correct connectors

OSHA Office of Training & Education44 Training Deenergize electric equipment before inspecting or repairing Using cords, cables, and electric tools that are in good repair Lockout / Tagout recognition and procedures Use appropriate protective equipment Train employees working with electric equipment in safe work practices, including:

OSHA Office of Training & Education45 Summary – Hazards & Protections Hazards Inadequate wiring Exposed electrical parts Wires with bad insulation Ungrounded electrical systems and tools Overloaded circuits Damaged power tools and equipment Using the wrong PPE and tools Overhead powerlines All hazards are made worse in wet conditions Protective Measures Proper grounding Use GFCI’s Use fuses and circuit breakers Guard live parts Lockout/Tagout Proper use of flexible cords Close electric panels Training

OSHA Office of Training & Education46 Summary Electrical equipment must be:  Listed and labeled  Free from hazards  Used in the proper manner If you use electrical tools you must be:  Protected from electrical shock  Provided necessary safety equipment