Www.LancasterLabsEnv.com Providing comprehensive scientific resources to environmental clients worldwide. Dissolved Gas Analysis: A Review and Comparison.

Slides:



Advertisements
Similar presentations
Radiochemical Methods and Data Evaluation
Advertisements

Analyze-Immediately Parameters pH Analyze Immediately Within 15 minutes of collection: pH Residual Chlorine Temperature Chlorine Dioxide Dissolved Oxygen.
Why Lab. Certification? Laboratory certification tries to insure that the laboratory is qualified and capable of analyzing the sample and obtaining quality.
LABORATORY CERTIFICATION & DATA QUALITY MICHAEL W. MILLER, Ph.D. NJ-DEP Office of Quality Assurance
Year of Clean Water: National Water Monitoring Day Water Testing Kits.
Instrumental Analysis
UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc.
Sampling: Your data is only as good as your field technicians.
Gas Chromatography: Hydrocarbon Gas Analysis By Ryan Waters November 20, 2006.
Mercury Monitoring The FDEP Laboratory Perspective Timothy W. Fitzpatrick (850)
Boiling points of the alkanes x x x x x x x x x x Temp 0 C This axis shows the number of carbons in the.
Dissolved oxygen and aquatic primary productivity.
SCR-15 Coal Slurry Underground Injection. SCR-15 “That the Department of Environmental Protection and the Bureau for Public Health shall jointly design.
Field-Based Analysis of Chlorinated Volatile Organic Halocarbons Field-Based Analysis of Chlorinated Volatile Organic Halocarbons
Lecture 8. GC/MS.
Lecture 8. Quality Assurance/Quality Control The Islamic University of Gaza- Environmental Engineering Department Environmental Measurements (EENV 4244)
1 Chapter 24 GC Gas Chromatography. 2 GC Mechanism of separation is primarily volatility. Difference in boiling point, vapor pressure etc. What controls.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Partitioning of Volatile Organic Carbon Compoundss.
Partitioning of VOCs: Why do we care? ä Determines how best to treat a site ä vapor extraction ä pump and treat ä remove contaminated soil ä Determines.
Quality Assurance/Quality Control Policy
DRAFT Field Sampling Guidance To be used this field season by DEC and consultants Initial focus on soil, groundwater, and vapor intrusion Future versions.
Monitoring Well Sampling. SAP (Sampling Analysis Plan) SAP (Sampling Analysis Plan) Frequency Frequency Purging Purging Pumps and Bailers Pumps and Bailers.
Presentation of Findings - Dissolved Methane Method Study Shale Network Workshop May 7-8, 2015 State College, PA Presented by Rock J. Vitale, CEAC Environmental.
Solutions and their Behavior Chapter Identify factors that determine the rate at which a solute dissolves 2. Identify factors that affect the solubility.
Understanding and Implementing SWAMP Comparability: Quality Assurance SWAMP Quality Assurance Help Desk Quality Assurance Research.
Status of the WET Program William Telliard Director, Analytical Methods USEPA Office of Science & Technology Office of Water.
Perchlorate Analysis by Ion Chromatography The CA DHS Protocol H.S. Okamoto, D.K. Rishi and S.K. Perera.
Extraction Methods Static Headspace (HS) Dynamic Headspace
ASTM WK Standard Test Method for Dissolved Gases Anne Jurek – Applications Chemist.
Roger Miller, Arkansas Department of Environmental Quality Barry Jackson, USGS Arkansas Water Science Center ARKANSAS EXCHANGE NETWORK FOR GROUNDWATER-QUALITY.
A Single Calibration for Waters and Soil Samples Performing EPA Method 8260 Anne Jurek – Applications Chemist.
1 / 9 ASTM D19 Method Validation Procedures William Lipps Analytical & Measuring Instrument Division July, 2015.
Science This introductory science course is a prerequisite to other science courses offered at Harrison Trimble. Text: Nelson, Science 10 Prerequisite:
Experiment 2 DISTILLATION AND GAS CHROMATOGRAPHY OF ALKANES.
Overbrook Scientific.
Laboratory Certification Update Part 2 Common Findings KWWOA Louisville April 15, 2015 Presented by Frank Hall, Laboratory Certification Coordinator.
Protocol for inter-laboratory calibration of Male’s monitoring network Nguyen Thi Kim Oanh EEM/SERD, AIT Male’ Declaration 4 th Regional Stakeholders-cum-
Lynsay Bensman 06 October 2009 Errors in Sampling/Monitoring in an Internal Corrosion Program NACE Eastern Area Conference.
Biochemistry Clinical practice CLS 432 Dr. Samah Kotb Lecturer of Biochemistry 2015 Introduction to Quality Control.
William Telliard U.S. EPA Office of Science and Technology
(2) Scientific processes. The student uses scientific methods during field and laboratory investigations. The student is expected to: (A) plan and implement.
Proving the Proof USBEVX CONFERENCE 2016 YVETTE GLENN, PHD CHEMIST, BEVERAGE ALCOHOL LABORATORY SCIENTIFIC SERVICES DIVISION February 16 – 18, 2016| Washington,
Chapter 1: The Nature of Analytical Chemistry
The Effects of Eutrophication and Salinization on Methane Production in Urban and Rural Lakes Rebecca Kiekhaefer Dr. Carla Koretsky, Thesis Chair Dr. Alan.
A LOOK AT AMENDMENTS TO ISO/IEC (1999) Presented at NCSLI Conference Washington DC August 11, 2005 by Roxanne Robinson.
Elizabeth Keily, Daniel Boehling, Arif M. Sikder, S
Quality Control and Assurance
Recommended Practices for Baseline Sampling of Dissolved Gases at Water Wells in Areas of Shale Oil & Gas Development Lisa J. Molofsky, Stephen D. Richardson,
Determination of Algae Compounds in Drinking Water
Method Modifications & ATP 40 CFR part and 136.5
Status of EPA Method 1631 for the Determination of Low-Level Mercury
Overview of EPA Method 1631, Revision E By Roy W
Pesticides in Groundwater
EPA Method Equivalency
Making Data Count: Why you need/want a QAPP
Update on Improvements to Dissolved Hydrocarbon Gases in Water Analysis Mark Bruce Ph. D. August 10, 2017.
Improved Accuracy of Dissolved Hydrocarbon Gas Analysis in Water
The Use of Advanced Instrumental Techniques to Address Emerging and Unique Circumstance Contaminants Charles Neslund, Scientific Officer, Eurofins Lancaster.
Have Instrument, make method; How new methods are made and validated
524.3 Purge Flow Study Anne Jurek – Sr. Applications Chemist
Update on ASTM and Standard Methods method development activities
EPA Method Equivalency
Rock J. Vitale, CEAC, David A. Gratson, CEAC
EPA Region 10 Alternate Test Procedures and Method Update Rule
Deyuan Kong, Brian Morlan, Roopa Kamath, and Sara Mcmillen
Sampling Methods for Dissolved Gases
A Field Analysis Technique for the Determination of PFAS Compounds
The Practicality (Necessity) of Use of Clean-up Techniques for the Analysis of D/F and PCB Congeners Charles Neslund, Scientific Officer, Eurofins Lancaster.
A Holding Time Evaluation Study for the Analysis of PFAS in Aqueous Samples Charles Neslund, Scientific Officer, Eurofins Lancaster Laboratories Environmental,
Best Practices for Identification and Quantitation
Presentation transcript:

Providing comprehensive scientific resources to environmental clients worldwide. Dissolved Gas Analysis: A Review and Comparison of the Methods and Variables that Impact Analytical Results Chuck Neslund, Technical Director TCEQ – Environmental Trade Fair and Conference May 5-6, 2015

22 Background The analysis for dissolved methane in water is an important parameter in baseline monitoring. Methane can occur naturally in water wells. The analysis of methane and other dissolved gases is important for determining if bioremediation is occurring. Therefore, the assessment of “clean” drinking water or water aquifers is significant.

33 Background Methane Boiling point = -161°C Molecular Weight = g/mol Solubility in Water = 22.7 mg/l

44 Background Several analytical approaches have been used for the analysis of methane (and dissolved gases); RSK-175 PA DEP 3686 PA DEP 9243 EPA 8015 (coupled with 5021) ASTM (proposed)

5 Background Dilemma There are differences between the methods and differences between laboratories performing the “same” method. Statement from MSC Proposal to Investigate Dissolved Methane Methods, “Dissolved methane results from water samples collected from the same source at the same time are comparable when analyzed within an individual laboratory but are not comparable when analyzed by different laboratories.”

66 Methods RSK-175 Originally developed at R.S. Kerr Environmental Research Center, Ada, OK. The method is an EPA Lab SOP. Each version of the procedure contains the following disclaimer; “This standard operating procedure has been prepared for the use of the Ground Water and Ecosystems Restoration Division of the US EPA and may not be specifically applicable to the activities of other organizations. This is not an official EPA approved method.”

77 Methods RSK-175 (cont’d) Method (“sop”) uses headspace for sample introduction. Gas Chromatography with Flame Ionization Detection (GC/FID) is determinative step. Multi-point calibration with gas standards. Use of Henry’s constants Samples collected in serum bottles of unspecified volume. Practice is to use 40 ml VOA vials. Analysis technique set-up to accommodate several dissolved gases in addition to methane including ethane, ethene, propane, butane and acetylene

88 Methods RSK-175 (cont’d) Recommends use of acid preserved vials, which allows a sample holding time of up to 14 days Sample handling by helium displacement Samples warmed to “room temperature” for analysis

99 Methods PA DEP 3686 Developed by PA Bureau of Laboratories (BOL). Revision 0 date April of 2012, but in-house version in use for several years prior. Headspace GC/FID. Multi-point calibration with aqueous standards. Aqueous standards prepared by bubbling gas into laboratory water until water is saturated. Only a single compound can be calibrated at a time. Listed as applicable to methane, ethane and propane.

10 Methods PA DEP 3686 (cont’d) Holding time of 7 days in unpreserved 40 ml vial Samples handled/transferred by opening 40 ml sample vial Presentation at NEMC in Washington, DC substantiating handling technique Dilutions prepared in headspace vials, able to be stored up to 7 days at <6°C

11 Methods PA DEP 9243 Developed by PA BOL in conjunction with an instrument manufacturer (Tekmar) Revision 0 from October of 2012 Uses Purge and Trap (P&T) with GC/FID Multi-point calibration using aqueous standards prepared similar to Only a single compound can be calibrated at a time. Method makes several references to “sequestering” of methane within the system.

12 Methods PA DEP 9243 (cont’d) As written, method applicable to methane, ethane, ethene and propane Requires maintaining sample temperature at <10°C while handling for analysis Holding time of 7 days in an unpreserved 40 ml vial

13 Methods EPA 8015/5021 Very generic EPA method Headspace GC/FID Multi-point calibration Preparation of calibration standards defined by laboratory SOP Based on use of gas standards or gas injected into water standards, multiple compounds calibrated for at same time

14 Methods ASTM (proposed) Uses headspace GC/FID Multi-point calibration using an instrument manufacturer’s (EST) equipment for the sample handling Calibration based on use of aqueous standards. Only a single compound calibrated for at a time. Handling of sample automated by instrument Method applicable to analysis of methane, ethane, ethene and propane

15 Methods ASTM (proposed) Holding time of 7 days in unpreserved 40 ml vials Samples allowed to warm to “room temperature” prior to handling and analysis

Example 16 ELLE Sample NumberRSK 175DL PA-3686DL%D % % % % % % % % % % Comparison of Methane Results – RSK-175 vs PA-3686

So Why the Differences? 1. Sample Handling What is the sample collected in? How is it transferred to the analytical system? At what temperature is the analysis performed? 2. Calibration/Calibration Standards How are calibration standards prepared? What calibration range is covered? 17

Example 18 Parameter RSK 175 PA3686 Conc% Error Conc% Error Calibration level 15 ppb-6% % Calibration level 215 ppb-0.9% % Calibration level 360 ppb7.3% % Calibration level 4100 ppb5.9% % Calibration level 5150 ppb4.1% % Calibration level 6500 ppb3.3% % Calibration level 7na % Calibration level 8na % Calibration level 9na % Avg % Error 4.60% 10.00% Coefficient of Determination Evaluation of Calibration Types

So Why the Differences? 3. Surrogate Standard Use Is a surrogate standard used? How is it introduced? 4. Specifics of Sample Analysis Does chromatographic system discriminate methane from other dissolved gases? How are dilutions performed? Is sample injection manual or automated 19

So Why the Differences? 5. Sample Collection How is sample collected? Is a preservative used? What is timeframe for analysis? 20

Next Steps Marcellus Shale Coalition (MSC) has conducted an inter-laboratory study for the analysis of dissolved gases, specifically methane. Goal is to identify the critical values that lead to variability in results between laboratories. Try to identify a consensus standard for the analysis of light gases in groundwater. 21

Acknowledgement Elizabeth Marin (Eurofins Lancaster Laboratories Environmental) Susan Goshert (Eurofins Lancaster Laboratories Environmental)

Thank you