Peter Hobson - Brunel University, UK3 July 2003 VPT faceplate testing  Samples of faceplate glass are irradiated to approximately 20 kGy gamma ray dose.

Slides:



Advertisements
Similar presentations
Richard Young Optronic Laboratories Kathleen Muray INPHORA
Advertisements

PPRP September 2002 UK CMS 1 CMS Endcap Electromagnetic Calorimeter and Global Calorimeter Trigger, Physics & Computing Presented by Peter Hobson, Brunel.
Vacuum Phototriodes for the CMS Electromagnetic Calorimeter Endcap
CMS ECAL Annual Review - CERN Sept 2001 R M Brown - RAL 1 Test results from 500 preproduction VPTs R M Brown RAL - UK CERN 19 September 2001.
STFC RAL EE at SLHC CERN 15/04/08 R M Brown - RAL 1 EE at SLHC What do we expect at SLHC? EE Layout VPT vulnerability to radiation - Faceplate darkening.
The visible-UV spectrometer we use permits the quantitative determination of the absorption and transmission of light in the wavelength range 200 nm*
Spectroscopy and Beer’s Law
Outline This Presentation contains slides appropriate for all the sections of the activity. – White slides are included (but hidden from the Slideshow)
Gamma irradiation Gamma cell model 220, series 142 from Atomic Energy of Canada Limited. Doses of 25, 50, 75, 100 and 500 kGy (dose rate of 4.3 kGy/h ).
1 William N MacPherson, Robert RJ Maier, James S Barton, Julian DC Jones Heriot-Watt University, EPS, Applied Optics and Photonics, Edinburgh, UK Alberto.
1 Molecular Luminescence Spectroscopy Lecture 31.
Characterization of primed state of CVD diamond by light and alpha particles C. Manfredotti Experimental Physics Department University of Torino INFN-
CMS ECAL Laser Monitoring System Toyoko J. Orimoto, California Institute of Technology, on behalf of the CMS ECAL Group 10th ICATPP Conference on Astroparticle,
CMS ECAL Laser Monitoring System Toyoko J. Orimoto, California Institute of Technology, on behalf of the CMS ECAL Group High-resolution, high-granularity.
Photons of Light The smallest unit of light is a photon A photon is often called a particle of light The Energy of an individual photon depends on its.
Lecture 2b. Electromagnetic Spectrum Visible range: = nm Ultraviolet: = nm Low energyHigh energy.
B W Kennedy, CCLRC Rutherford Appleton Laboratory VPTs for the CMS experiment B W Kennedy CCLRC Rutherford Appleton Laboratory St Petersburg, 26 April.
Introduction A modification of the Fricke solution system to make it suitable for low-level dosimetric studies was proposed about three decades ago [1].
The Effect of Light Wave Length on Algae Growth
Status of the PiN diodes irradiation tests B. Abi( OSU), R. Boyd (OU), P. Skubic (OU), F. Rizatdinova (OSU), K.K. Gan (Ohio State U.)
TÍTULO DO TRABALHO NOMES DOS AUTORES ENDEREÇOS E DOS AUTORES INTRODUTION Gammacell 220 Series 39 is a irradiation device purchased by CDTN/CNEN in.
CMS Week, CERN, 2002 R M Brown - RAL 1 Performance Characteristics of Production VPTs R M Brown, B W Kennedy, P R Hobson (with crucial input from D J A.
Scholar: Abdul Aziz Abdul Rehman Al-Muqhim Supervisor: Prof. Dr. Abdul Majid Department of Physics, College of Science Majmaah University (Zulfi Campus)
Peter Hobson - Brunel University, UK3 July 2003 VPT 4 Tesla testing  An automated characterisation facility based at Brunel has been commissioned to handle.
PSD8 September 2008, Glasgow.P R Hobson, Brunel University 1 Avalanche Photodiodes and Vacuum Phototriodes for the Electromagnetic Calorimeter of the CMS.
TIPP A Testable Conventional Hypothesis for the DAMA-LIBRA Annual Modulation Signal David Nygren LBNL.
UV-Vis Absorption Spectroscopy
CMS SLHC workshop, D.J.A. Cockerill (RAL)1 CMS SLHC Workshop The CMS ECAL Detector at SLHC D Cockerill RAL
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 19 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Do Now: How many frames are in a Pixar animated movie such as The Incredibles? [What would you need to know? Explain your reasoning and show your work.]
Do Now: How many frames are in a Pixar animated movie such as The Incredibles? [What would you need to know? Explain your reasoning and show your work.]
Microspectrophotometry Calibration. Calibration Calibration ensures that the instrument is functioning to an acceptable level. Before carrying out calibration.
Light, Color, Spectral Lines Spectrum of light Photon energy Atomic structure Spectral lines Elements in stars How the eye sees color Temperature and color/spectrum.
Effects of Electromagnetic Waves
© 2010 Pearson Education, Inc. Range of Visible Light Our eyes can see from 400 (blue/purple) to 700 (red) nm. Nm = nanometers = meters Our eyes.
CMS ECAL Laser Monitoring System Christopher S. Rogan, California Institute of Technology, on behalf of the CMS ECAL Group High-resolution, high-granularity.
DEVELOPING A SOLAR RADIOMETRIC CALIBRATION SYSTEM USING SPECTRAL SYNTHESIS. Peter Fox (HAO/NCAR) We present quantitative information on how we estimate.
B W Kennedy, CCLRC Rutherford Appleton Laboratory Vacuum Phototriodes for the CMS Electromagnetic Calorimeter Endcaps K.W.Bell, R.M.Brown, D.J.A.Cockerill,
August 99 E.Auffray CMS/ECAL STATUS on PWO crystals from Bogoroditsk after one year of preproduction for CMS-ECAL Etiennette Auffray SCINT 99, 16 August.
Tools of Modern Astronomy
Nanoscale Cr 4+ Doped Olivine Crystallites Used In Optical Amplifiers and Lasers Presentation by: Victor Ortiz Mentor: Dr. Alexei Bykov Mentor: Dr. Alexei.
Slide 1 5th LHC RADIATION WORKSHOP, CERN, , Jochen Kuhnhenn, Fraunhofer INT Radiation tolerant fibres for LHC controls and communications.
Space Radiation Environment Tests on HOEs Geary Schwemmer* NASA GSFC Work Supported by NASA and IPO *new affiliation: Science and Engineering Services,
RESMDD02 July , Florence, A.Singovski, University of Minnesota1 Radiation hardness of the Avalanche Photodiodes for ECAL CMS detector at CERN.
Remembering PWO Radiation hardness studies at IHEP, Protvino Y. Kubota.
Journal #22 What is the purpose of a barometer? What is the most commonly used barometer?
Apatity, Bogoroditsk and Shankhai PWO Crystals under Gamma Irradiation (PRELIMINARY RESULTS) Apatity IHEP Khurchatov North Crystals CMS + BTeV Alice Presented.
1 Optical fiber irradiation tests 1.Results from ATLAS LAr 2.Narrow down to Germanium doped GRIN fiber 3.Preliminary tests 4.Tests in the plan Jingbo Ye.
Radiation Tests on optical fibres for the LHC machine T. Wijnands, D. Ricci CERN EN department Fraunhofer INT.
Motivation The knowledge of tissue optical properties is necessary for the development of the novel optical technologies of photodynamic and photothermal.
Presented by Jianghua Kyungpook National University 5 th Seminar on Dark Matter Search and Double beta decay, Sept 22-23, 2011, Yangyang, Korea.
Measurements and modeling of water vapor from solar spectral irradiance during ATTREX Bruce Kindel, Peter Pilewskie, Sebastian Schmidt, Troy Thornberry,
The Study of Light.
HEP2001, Budapest, July 2001 R M Brown - RAL 1 The Vacuum Phototriodes for the CMS Electromagnetic Calorimeter P R Hobson, D C Imrie, O Sharif Brunel University,
Date of download: 7/9/2016 Copyright © ASME. All rights reserved. From: Solar Radiation Conversion With Mesoporous Silica Activated by Rare-Earth Ions.
SPECTROPHOTOMETRY White light contains all wavelengths of light in the visible region of the EM. A substance appears colored because it absorbs light.
Properties of Recent SIC Crystals
Status of VPT Delivery and Testing
HEP2001, Budapest, July R M Brown - RAL
Studies of the effect of the LHC cycle on
SPECTROSCOPY.
Lecture 2b Beer’s Lambert Law.
Studies of the effect of the LHC cycle on
CMS ECAL Endcaps: Fluence/Dose (500 fb-1)
Radiation tolerant fibres for LHC controls and communications
Scheme 1. Scheme of the quartz sample holder.
Ensuring Reliability June 2013 Paul Beaumont.
Matthew Rose - Emission Spectra of Bicron Scintillators
Ultraviolet A Irradiation of C57BL/6 Mice Suppresses Systemic Contact Hypersensitivity or Enhances Secondary Immunity Depending on Dose  Scott N. Byrne,
Matthew Rose - Emission Spectra of Bicron Scintillators
Presentation transcript:

Peter Hobson - Brunel University, UK3 July 2003 VPT faceplate testing  Samples of faceplate glass are irradiated to approximately 20 kGy gamma ray dose in our facility at Brunel.  At least 3 faceplate samples per glass batch are tested.  Samples are irradiated in the dark, at a temperature around 20°C, at a dose rate of abour 300 Gy per hour.  Induced absorption is measured within two hours of irradiation.  Irradiated samples are stored in the dark at 20±1°C.  Spectrophotometer is recalibrated every 12 months.

Peter Hobson - Brunel University, UK3 July 2003 VPT faceplate testing  We use the latest measured PbWO 4 emission spectrum appropriate for end-cap crystals  This is convolved with the induced absorption over the wavelength range 350 nm to 610 nm  The integrated transmission after irradiation must be > 90% of the unirradiated transmission for all sample in one batch.

Peter Hobson - Brunel University, UK3 July 2003 VPT faceplate testing  Irradiated causes the growth of an absorption band centred around 330 nm. This band is well known in the literature for borosilicate glasses.  Even after 20 kGy dose there is no induced absorption at 800 nm. This allows a measurement consistency check.  The induced absorption shape is very similar in different batches, peak height does however vary.

Peter Hobson - Brunel University, UK3 July 2003 VPT faceplate testing  Recent faceplates (June 2003) were generally very good quality, but note batch Glass Post irradiation internal transmission (%) after 20.0 kGy

Peter Hobson - Brunel University, UK3 July 2003 VPT faceplate testing  One sample from batch showed very poor radiation tolerance.

Peter Hobson - Brunel University, UK3 July 2003 VPT faceplate testing  Long term annealing (in dark at 20°C) shows increase in absorption in the band centres at 330 nm.

Peter Hobson - Brunel University, UK3 July 2003 Summary  Pre-testing of faceplate glass is an essential part of ensuring that production tubes will be able to operate over the full lifetime of CMS.  We have a standard protocol for determining which glass batches can be used.  A new Hitachi U4100 spectrophotometer, used for all glass batches in the production run, has improved our measurement accuracy repeatability.  Recent glass batches have been very good.  The anomalous result for one sample of a batch (29992) is unique – all other batches have shown very little variation between samples.