Fire Detection System General Locations and Operation
Description: Salwico Cargo Addressable Fire Detection System The Fire Detection System consists of a single control panel, multiple smoke detectors, pull stations (Manual Call Points or MCPs), annunciator bells, and flashing red indicator strobes or strobe/horns in machinery spaces. The smoke detectors and MCPs are combined into two individual detection loops: Loop 1 for the Machinery Spaces, and Loop 2 for all other areas of the vessel. Loop 1 is divided into three separate zones (each Zone being a separate space. Loop 2 is divided into 10 zones (each Zone being a separate space. Fire Detection System
Description: Control Panel – Wheelhouse Starboard Stack Bulkhead Fire Detection System
Description: Control Panel – Wheelhouse Starboard Stack Bulkhead Fire Detection System Consilium/Salwico Control Panel M 4.3
Description: Manual Call Points (MCPs) – Salwico MCP-A (GB) Part no A Fire Detection System
Description: MCPs Resetting and Testing the MCPs Requires a special plastic key.
Description: Optical Smoke Detector Salwico EV-P Part no Fire Detection System
Description: Fire Alarm Bells Part no. SSM 24-6 Fire Detection System Example: Equipment Room Example: Wheelhouse
Description: Fire Alarm Strobes Part no. SRK Fire Detection System Example: Aft Hold Example: HVAC Room
Description: Strobe/Horn Combination Part no. P2RK Fire Detection System Example: STBD VSP Room
General Locations: Loop 1, Zone 1 VSP Room – (1) MCP – (1) Bell – (2) Detectors – (1) Strobe/Horn Fire Detection System
General Locations: Loop 1, Zone 2 Engine Room – (2) MCPs – (1) Bell – (6) Detectors – (1) Strobe – (1) Strobe/Horn Fire Detection System
General Locations: Loop 1, Zone 3 Aft Hold – (1) MCP – (1) Bell – (1) Strobe Fire Detection System
General Locations: Loop 2, Zone 1 Wheelhouse – (2) MCPs – (1) Bell – (1) Detector Fire Detection System
General Locations: Loop 2, Zone 2 Boat Deck Interior Stairwells – (2) MCPs – (2) Detectors Fire Detection System
General Locations: Loop 2, Zone 3 CIC – (2) MCPs – (1) Bell – (1) Detector Fire Detection System
General Locations: Loop 2, Zone 4 HVAC Room (Boat Deck) – (1) MCP – (1) Detector – (1) Strobe Fire Detection System
General Locations: Loop 2, Zone 5 Boat Deck Interior Passage – (1) MCP – (1) Detector Fire Detection System
General Locations: Loop 2, Zone 6 Main Deck Stair Well – (1) MCP – (1) Detector Fire Detection System
General Locations: Loop 2, Zone 7 Multi-Purpose Room – (3) MCPs – (1) Bell – (2) Detectors Fire Detection System
General Locations: Loop 2, Zone 8 HAZMAT Assessment – (1) MCP Fire Detection System
General Locations: Loop 2, Zone 9 Equipment Room – (2) MCPs – (1) Bell – (1) Detector Fire Detection System
General Locations: Loop 2, Zone 10 EMS Room – (1) MCP – (1) Bell – (3) Detectors Fire Detection System
Operations: For a more in depth explanation of the Fire Detection System operations, go to pages 303 to 312 of the Foss Maritime Fire Boat Operations Manual, or refer to the Consilium/Salwico Cargo Addressable Fire Detection System User Manual.
Fire Detection System Operations: Quick Guide for Control Panel M 4.3. If system detects a fire or fault, hit the mute button to silence, then look at display screen to find out what Loop, Zone and device is alarming.