Customer Driven Solutions2 Background Gearboxes with High Power –Duty Cycle Issue How to stabilize temperature? Modular cooling package for stationary applications Pat Laake at Flo
Customer Driven Solutions3 Challenges High Viscosity Gear Lube –Cooler pressure drop –Circulation pump –Cold oil startup Energy Management Control Logic –How to keep simple? Goal of small footprint Electric motor specs Each system different
Customer Driven Solutions4 Origional Concept
Customer Driven Solutions5 Cooling Circuit
Customer Driven Solutions6 Electrical Logic Enable signal from customer’s machine Motor starters, 2HP & 3 HP Turn system on every 5? minutes to circulate oil. If measured temperature is too high, continue running until cool. Pressure switch: shut down if pressure drops = leak. Include time delay after startup so system can pressurize. Lack of cooling fault: If system doesn’t cool in x period of time then activate alarm. Power light Service disconnect
Customer Driven Solutions7 Cooler
Customer Driven Solutions8 Components Will add more images Waiting for info from Pat Laake
Customer Driven Solutions9 Quote from Flo FGI Custom Frame/Drip Pan Baldor CM3558T 2 HP 1800 RPM 230/460V 3 PH TEFC with Base and C-Face Vescor P/M Adapter and Lovejoy Coupling Set Eckerle EIPS2019 Internal Gear Pump 19.3 CC/Rev Pall UR 219 CA16++20ZA9 Filter Head Pall UE219AN20Z Element Pall RC860MZ084Z Visual Indicator FluFlo Relief Valve VS4RHS-US Thermal Transfer AOVH-40-3 PH Air/Oil Heat Exchanger GEM Electric Control Box NEMA 12 Relay Logic Barksdale 9600 Series Pressure Switch Wika Temperature Transducer Labor, Test, Paint Misc. Fittings and Hardware to Complete $8, The Flodraulic Group Inc Pat Laake
Customer Driven Solutions10 Questions?