SWRI C13 Filter base mods for aux cooling system Stand Photo J McCord April 1, 2005.

Slides:



Advertisements
Similar presentations
Water Source Heat Pump Systems
Advertisements

The idea evolved from two different contractor customers who shared with us a better way to perform hydrostatic testing of DWV piping system. Two different,
Engine Cooling And Lubrication
Fluid Mechanics.
Engine & Transport Integrated Cooling Systems. © Alfa LavalSlide 2 Alfa Laval Integrated Cooling Systems, ALICS Integrated marine cooling.
© 2012 Delmar, Cengage Learning Automotive Plumbing: Tubing and Pipe Chapter 24.
HVACR316 - Piping Piping and Fitting.
Refrigeration Components
Reservoirs Covered in Ch. 5 of Vickers Text
Certified Service Training Start Centrifugal Trash Pumps.
Glycol Pumps Operating Pressure: 100 to 1500 psi Circulation Rate: 3 to 450 gph.
Advanced hydraulic solutions
PEUGEOT 206 INSTALLATION 99’— 05’ TU5JP4
HCS Series Screw Compressor Packages. 2 HCS Series.
Spiral Condensors. Working Principle The Spiral Condensor consists of two sheets stainless steel strips which have been wounded from the centre.
Thermosyphon - Free Cooling
NOAA Humidifier – smaller (lower flow) version (yours will have larger tubing and fittings) Ribbon heater Thermal cutoff switch Swagelok reducing union,
Cooling System For Gear Box Gear Box Cooler Air/Oil cooler fan driven Wash down Motor Gear Pump –Moves oil from gear box through cooler –Optional Oil.
Connecting to industry 1. 2 Safety Break-away Couplings.
Hydraulics For The Long Term
Compressed Air Piping Systems by Asahi/America
JHCBC AUTO A/C PERFORMANCE TESTING CHAPTER 3 Page
Glycol Pumps Operating Pressure: 100 to 2000 psi Circulation Rate: 3 to 450 gph.
Connecting to industry. Swivels Dixon Valve & Coupling Company manufactures Swivel Joints that are intended for piping applications. Be sure to contact.
1 Fuel Pumps. 2 Pumps 1.All oil burners for residential heating have pumps A. They are connected to a motor through a coupling 2.Description A. An oil.
Buffer Fluid Reservoirs and equipment. ASME – ANSI – API 610 – API 682.
FEASIBILITY OF COMPONENTS CLARA ECHAVARRIA & JONATHON LOCKE.
Directional Control Valve CV691. Present system New Proposed System with CV691 valve Directional Control Valve CV691 with integrated Flow Control Valve.
Engineer Training Cooler TJ8300 / TJ8500 Cooler. Engineer Training Cooler TJ8300 / TJ8500 Confidential 2 Introduction.
EMISSION PROBE PARTS TUBE: 3/8” OD x wall Stainless Steel Length determined by pipe diameter and placement of connecting end to allow easy connection.
Forging new generations of engineers. Basic Pneumatics.
Tuesday, November 16, 2010G. Favre EN/MME1 PIMS prototype construction experience Details of the construction procedure elaborated by CERN for the PIMS.
SC Project Review of NCSX, April 8-10, 2008 NCSX Coil Services P.L. Goranson Work Package 161.
1 HVACR316 - Piping Copper Tubing and Fittings. 2 2 Safety Refrigerant cylinders should be stored and transported in the upright position to keep the.
R. Than J. Huang P. Orfin T. Tallerico Jan. 19, 2011
FUEL TANKS, LINES, FILTERS, and PUMPS CBCAUTOMOTIVERKCBCAUTOMOTIVERK.
Machinery Cooling Water System Locations and Operations.
Maggie Alvarado Diego Azevedo Raphael Santos Cavalcanti Natalie Levings Richard Robards Bruno Vieira.
Engine Performance BASIC MAINTENANCE AND LIGHT REPAIR.
Page 1 Sapphire by pass line  Design Concept of Cooling Water System : Funnel 10 line Tank 2 10 tones Chiller -20cm tilt - 5cm distance between growers.
T-6B On-Board Oxygen Generation System (OBOGS)
7 A/C System Components, Operation, and Service.
Booster Compressors The rotary screw market is our bread and butter but we do manufacture a line of piston compressors to meet a demand in that market.
Force Feed Lubricator System
EMERGING TECHNOLOGIES AVAILABLE TO REDUCE COMPRESSED AIR DEMAND Double Acting Air Cylinder Double Acting Air Cylinder Air Operated Diaphragm Pumps Air.
Diesel Technology Fittings/ Hoses.
ME444 ENGINEERING PIPING SYSTEM DESIGN
Lubricating system Components
Machinery Auxiliary Systems
Engine Lubrication Systems
Advisor: Dr. Shangchao Lin
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Swivels. Swivels Dixon Valve & Coupling Company manufactures Swivel Joints that are intended for piping applications . Be sure to contact Dixon prior.
UT Integration meeting UT CO2 COOLING DISTRIBUTION SYSTEM
SERVICE TRAINING MANUAL ENGINE LACETTI.
Stainless Steel Hoses Dealers in UAE
C Air Compressor Up-fit and Plumbing Guide For LDI B3
SB Packing Automatic Downpuller Power Unit
Trouble Shooting Hydraulic System Failure
Troubleshooting 11/14/2018 Water King Service Seminar.
Lubricating system Components
Gas Cooling Pumps System
K/QSK19 Liter Pan Adapter Threaded Hole Modification
Instant Electric Heating Tap - Wall Mount or Surface Mount
Water-saving Shower Faucet
Self-sealing Cable Transit Panel Project Update
CRYOMODULE FINAL ASSEMBLY
Connection Types & Sizes BSPT or NPT threaded
P2 25 mm (1") Metal Pump.
Presentation transcript:

SWRI C13 Filter base mods for aux cooling system Stand Photo J McCord April 1, 2005

Filter Base Pictorial View ( ) Oil cooler bypass valve Cooler inlet port Cooler outlet port Cup plug Oil Filter in pressure (includes engine oil cooler) J McCord April 1, 2005

Proposed Filter Base Mods Bead weld a Slip fit aluminum coupling (drill & tap for 1” straight thread) Install an aluminum disc (weld in place) No. 16 straight thread JIC fitting Tap and install a ½” pipe plug. (use silicon to seal plug) From filter J McCord April 1, 2005

Detail of cup plug feature at back end of base Fabricate a 1” straight thread aluminum coupling that will slip into the port. Bead weld the coupling in place. J McCord April 1, 2005

C13 Warm-up Data Steps 1 thru 5 J McCord April 1, 2005

C13 Warm-up Data Steps 1 thru 5 J McCord April 1, 2005

C13 Warm-up Data Steps 1 thru 5 J McCord April 1, 2005

C13 Component Pressure Drop Steps 1 thru 5 J McCord April 1, 2005

C13 Oil Control System Range Test Condition J McCord April 1, 2005

Results Oil gallery pressure appeared stable at 390 kPa. Oil Control System volume: 1300 ml (1080 grams at test temp) Control test conditions: 93.2 C to C –Process water temp ~70 F –Ambient temp ~70 F Pressure Drop –Engine Cooler: 113 kPa –Auxiliary Cooler: 57 kPa –Oil Filter: 70 kPa –System: 240 kPa J McCord April 1, 2005

Parts List In Progress Heat Exchanger: ITT Standard SSCF PN# SN No. 16 Steel braided hose (36 inches max.) 2 - No. 16 straight thread hose fittings 2 – No. 16 NPT thread hose fittings J McCord April 1, 2005