Status of CNM RD50 LGAD Project27th RD50 Workshop, CERN 2-4 Dec. 2015 Centro Nacional del MicroelectrónicaInstituto de Microelectrónica de Barcelona Status.

Slides:



Advertisements
Similar presentations
Trapping in silicon detectors G. Kramberger Jožef Stefan Institute, Ljubljana Slovenia G. Kramberger, Trapping in silicon detectors, Aug , 2006,
Advertisements

New approach to simulate radiation damage to single-crystal diamonds with SILVACO TCAD Florian Kassel, Moritz Guthoff, Anne Dabrowski, Wim de Boer.
F.R.Palomo, et al.MOS Capacitor DDD Dosimeter 1/13 RD50 Workshop - CERN – November 2012 MOS Capacitor Displacement Damage Dose (DDD) Dosimeter F.R.
P. Fernández-Martínez – Optimized LGAD Periphery25 th RD50 Workshop, CERN Nov Centro Nacional de MicroelectrónicaInstituto de Microelectrónica.
Giulio Pellegrini 4th SILC Collaboration Meeting, Dec. 2006, Barcelona, Spain Giulio Pellegrini 4th SILC Collaboration Meeting, Dec. 2006,
Ultra-Fast Silicon Detector 1 This report is a summary of what was shown at IEEE. Nicolo Cartiglia, INFN, Torino - UFSD - Timing Workshop CERN 2014 Nicolo.
Characterization of 150  m thick epitaxial silicon pad detectors from different producers after 24 GeV/c proton irradiation Herbert Hoedlmoser (1), Michael.
20th RD50 Workshop (Bari)1 G. PellegriniInstituto de Microelectrónica de Barcelona G. Pellegrini, C. Fleta, M. Lozano, D. Quirion, Ivan Vila, F. Muñoz.
Wide Bandgap Semiconductor Detectors for Harsh Radiation Environments
New Technological Capabilities at CNM25 th RD50 Workshop. CERN, November 19th-21th, 2014 Centro Nacional de MicroelectrónicaInstituto de Microelectrónica.
Charge collection studies on heavily diodes from RD50 multiplication run G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
Haga clic para modificar el estilo de texto del patrón Progress on p-type isolation technology M. Lozano, F. Campabadal, C. Fleta, S. Martí *, M. Miñano.
Charge collection studies on heavily diodes from RD50 multiplication run (update) G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
F.R.PalomoDevice Simulation Meeting 1/22 CERN 7th July New 3D Detectors.
RAD2012 Ultra-Thin 3D detectors Celeste FletaInstituto de Microelectrónica de Barcelona Celeste Fleta Instituto de Microelectrónica de Barcelona Centro.
11 th RD50 Workshop, CERN Nov Results with thin and standard p-type detectors after heavy neutron irradiation G. Casse.
KIT – University of the State of Baden-Wuerttemberg and National Research Center of the Helmholtz Association Institut für Experimentelle Kernphysik
Semi-conductor Detectors HEP and Accelerators Geoffrey Taylor ARC Centre for Particle Physics at the Terascale (CoEPP) The University of Melbourne.
ALBA Synchrotron – 17 June 2010 Centro Nacional de MicroelectrónicaInstituto de Microelectrónica de Barcelona First Measurements on 3D Strips Detectors.
M. Bruzzi et al. Thermal donors in MCz Si, Trento Meeting Rd50 February 28, 2005 Mara Bruzzi, D. Menichelli, M. Scaringella INFN Florence, University of.
1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.
SILICON DETECTORS PART I Characteristics on semiconductors.
Time Resolution of Thin LGADs Results from the Nov 2014 Beam Test at CERN Improvement in hand: Sensor Capacitance Measurements with  Front TCT 1 Hartmut.
INTEGRATED CIRCUITS Dr. Esam Yosry Lec. #4. Ion Implantation  Introduction  Ion Implantation Process  Advantages Compared to Diffusion  Disadvantages.
Silicon detector processing and technology: Part II
Analysis of Edge and Surface TCTs for Irradiated 3D Silicon Strip Detectors Graeme Stewart a, R. Bates a, C. Corral b, M. Fantoba b, G. Kramberger c, G.
Ultra-Fast Silicon Detector 1 Aide memoire: we are exploring the possibility of using silicon detectors with moderate gain to achieve ~ 20 ps time resolution.
Status report on A 2D position sensitive microstrip sensor with charge division. A segmented Low Gain Avalanche Detector for tracking E. Currás, M. Fernández,
CERN, November 2005 Claudio Piemonte RD50 workshop Claudio Piemonte a, Maurizio Boscardin a, Alberto Pozza a, Sabina Ronchin a, Nicola Zorzi a, Gian-Franco.
Haga clic para modificar el estilo de texto del patrón Infrared transparent detectors Manuel Lozano G. Pellegrini, E. Cabruja, D. Bassignana, CNM (CSIC)
25th RD50 Workshop (Bucharest) June 13th, Centro Nacional de MicroelectrónicaInstituto de Microelectrónica de Barcelona IMB-CNM, Barcelona (Spain)
NEWATLASPIX: Development of new pixel detectors for the ATLAS experiment upgrade Giulio Pellegrini.
1 Nicolo Cartiglia, INFN, Torino - RD50 - Santander, 2015 Timing performance of LGAD-UFSD 1.New results from the last CNM LGAD runs 2.A proposal for LGAD.
Charge Collection and Trapping in Epitaxial Silicon Detectors after Neutron-Irradiation Thomas Pöhlsen, Julian Becker, Eckhart Fretwurst, Robert Klanner,
Experience with 50um thick epi LGAD
RD50 funding request Fabrication and testing of new AC coupled 3D stripixel detectors G. Pellegrini - CNM Barcelona Z. Li – BNL C. Garcia – IFIC R. Bates.
1/14 Characterization of P-type Silicon Detectors Irradiated with Neutrons M.Miñano 1, J.P.Balbuena 2, C. García 1, S.González 1, C.Lacasta 1, V.Lacuesta.
9 th “Trento” Workshop on Advanced Silicon Radiation Detectors Genova, February 26-28, 2014 Centro Nacional de MicroelectrónicaInstituto de Microelectrónica.
TCT measurements with SCP slim edge strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko.
Ljubljiana, 29/02/2012 G.-F. Dalla Betta Surface effects in double-sided silicon 3D sensors fabricated at FBK at FBK Gian-Franco Dalla Betta a, M. Povoli.
Celso Figueiredo26/10/2015 Characterization and optimization of silicon sensors for intense radiation fields Traineeship project within the PH-DT-DD section.
The Sixth International "Hiroshima" Symposium Giulio Pellegrini Technology of p-type microstrip detectors with radiation hard p-spray, p-stop and moderate.
Time Resolution of UFSD 1 Hartmut F.-W. Sadrozinski, UFSD Timing RD50 Hartmut F.-W. Sadrozinski Z. Galloway, B. Gruey, H. Grabas, Z. Liang, S. N. Mak,
Study on and 150  m thick p-type Epitaxial silicon pad detectors irradiated with protons and neutrons Eduardo del Castillo Sanchez, Manuel Fahrer,
PH-DT-DD Meeting – PH-DT-DD: SSD-Solid State Detectors The team today (CERN & visitors): R&D: Development of radiation tolerant silicon detectors.
Giulio Pellegrini 27th RD50 Workshop (CERN) 2-4 December 2015 Centro Nacional de MicroelectrónicaInstituto de Microelectrónica de Barcelona 1 Status of.
6th Trento Workshop on Advanced Silicon Radiation Detectors1/16 J.P. BalbuenaInstituto de Microelectrónica de Barcelona IMB-CNM (CSIC) J.P. Balbuena, G.
Simulation of new P-Type strip detectors 17th RD50 Workshop, CERN, Geneva 1/15 Centro Nacional de MicroelectrónicaInstituto de Microelectrónica de Barcelona.
Claudio Piemonte Firenze, oct RESMDD 04 Simulation, design, and manufacturing tests of single-type column 3D silicon detectors Claudio Piemonte.
P. Fernández-Martínez – Optimized LGAD PeripheryRESMDD14, Firenze 8-10 October Centro Nacional de MicroelectrónicaInstituto de Microelectrónica de.
Trench detectors for enhanced charge multiplication G. Casse, D. Forshaw, M. Lozano, G. Pellegrini G. Casse, 7th Trento Meeting - 29/02 Ljubljana1.
Giulio Pellegrini Actividades 3D G. Pellegrini, C. Fleta, D. Quirion, JP Balbuena, D. Bassignana.
G. PellegriniInstituto de Microelectrónica de Barcelona Status of LGAD RD50 projects at CNM28th RD50 Workshop (Torino) 1 Status of LGAD RD50 projects at.
June T-CAD Simulations of 3D Microstrip detectors a) Richard Bates b) J.P. Balbuena,C. Fleta, G. Pellegrini, M. Lozano c) U. Parzefall, M. Kohler,
Giulio Pellegrini 12th RD50 - Workshop on Radiation hard semiconductor devices for very high luminosity colliders, Ljubljana, Slovenia, 2-4 June 2008 Report.
3D Simulation Studies of Irradiated BNL One-Sided Dual-column 3D Silicon Detector up to 1x1016 neq/cm2 Zheng Li1 and Tanja Palviainen2 1Brookhaven National.
Radiation damage studies in LGAD detectors from recent CNM and FBK run
Radiation Damage TCAD Analysis of Low Gain Avalanche Detectors
Characterization and modelling of signal dynamics in 3D-DDTC detectors
First production of Ultra-Fast Silicon Detectors at FBK
Radiation Damage TCAD Analysis of Low Gain Avalanche Detectors
Irradiation and annealing study of 3D p-type strip detectors
Graeme Stewarta, R. Batesa, G. Pellegrinib, G. Krambergerc, M
RD50 Workshop June 2016, Torino, Italy
Hartmut F.-W. Sadrozinski, UFSD, 28th RD50 Meeting
Replacing Boron with Gallium
Report from CNM activities
Vladimir Cindro, RD50 Workshop, Prague, June 26-28, 2006
Forward-bias operation of FZ and MCz silicon detectors made with different geometries in view of their applications as radiation monitoring sensors J.
Enhanced Lateral Drift (ELAD) sensors
Presentation transcript:

Status of CNM RD50 LGAD Project27th RD50 Workshop, CERN 2-4 Dec Centro Nacional del MicroelectrónicaInstituto de Microelectrónica de Barcelona Status of LGAD RD50 projects G. Pellegrini, M. Baselga, M. Carulla, P. Fernández, D. Flores, S. Hidalgo, A. Merlos D. Quirion Instituto de Microelectrónica de Barcelona (IMB) Centro Nacional de Microelectrónica (CNM-CSIC) Barcelona, Spain

Status of CNM RD50 LGAD Project27th RD50 Workshop, CERN 2-4 Dec Centro Nacional del MicroelectrónicaInstituto de Microelectrónica de Barcelona RD50 Institutes Participating The aim of the project was to fabricate the first segmented LGAD in thin (epytaxial) substrates.

Status of CNM RD50 LGAD Project27th RD50 Workshop, CERN 2-4 Dec Centro Nacional del MicroelectrónicaInstituto de Microelectrónica de Barcelona

Status of CNM RD50 LGAD Project27th RD50 Workshop, CERN 2-4 Dec Centro Nacional del MicroelectrónicaInstituto de Microelectrónica de Barcelona Different Measurements  Diamond light source (Glasgow)  CERN TCT setup  Santa Cruz TCT setup  IBIC Sevilla (CNM) Results presented at different RD50 workshops M. Baselga´s PhD thesis. Presented at the Trento Workshop in 2015.

Status of CNM RD50 LGAD Project27th RD50 Workshop, CERN 2-4 Dec Centro Nacional del MicroelectrónicaInstituto de Microelectrónica de Barcelona This project aims to fabricate, test and irradiate thin LGAD sensors. Thin sensors offer many attractive features such as higher charge collection efficiency, short drift time, and a signal that is both shorter and steeper while retaining a large amplitude due to the multiplication mechanism.

Status of CNM RD50 LGAD Project27th RD50 Workshop, CERN 2-4 Dec Centro Nacional del MicroelectrónicaInstituto de Microelectrónica de Barcelona High-granularity Timing Detector could be placed in front of LAr Calorimeter endcap. See Hartmut and Nicolo´s talks. The production will have geometries that can be used to evaluate the application of LGAD sensors in forthcoming LHC experiments such as TOTEM, HGTD and CT-PPS.

Status of CNM RD50 LGAD Project27th RD50 Workshop, CERN 2-4 Dec Centro Nacional del MicroelectrónicaInstituto de Microelectrónica de Barcelona Status of the project  Simulation of the different geometries already concluded.  Design of the mask in progress.  Fabrication will start in January 2016.

Status of CNM RD50 LGAD Project27th RD50 Workshop, CERN 2-4 Dec Centro Nacional del MicroelectrónicaInstituto de Microelectrónica de Barcelona Mask design The mask will include standard pads and test structures

Status of CNM RD50 LGAD Project27th RD50 Workshop, CERN 2-4 Dec Centro Nacional del MicroelectrónicaInstituto de Microelectrónica de Barcelona The project aims to replace Boron with Gallium Dopants such as Ga or Al form complexes with radiation-induced defects, which may have less impact on device performance, when compared to the boron related defect (B i -O i ) complex. This study demonstrates that using gallium as dopant in Si instead of boron can reduce carrier removal effect. 1.G. Kramberger et al., “Radiation effects in Low Gain Avalanche Detectors after hadron irradiations”, 2015 JINST 10 P A. Khana, et al., “Strategies for improving radiation tolerance of Si space solar cells'', Solar Energy Materials & Solar Cells 75 (2003) 271.

Status of CNM RD50 LGAD Project27th RD50 Workshop, CERN 2-4 Dec Centro Nacional del MicroelectrónicaInstituto de Microelectrónica de Barcelona Simulation of other p-layer doping ions: Gallium Gallium has lower penetration than Boron, but higher diffusion (with annealing) Simulation predicts that Gallium Implantation (Dose=1.3e13, Energy=60) through 35 nm SiO2 is enough to obtain a similar doping profile than Boron Implantation Gallium Implantation. Silvaco TCAD Simulation Active Gallium Substrate Doping Active Boron Active Gallium Substrate Doping Active Boron

Status of CNM RD50 LGAD Project27th RD50 Workshop, CERN 2-4 Dec Centro Nacional del MicroelectrónicaInstituto de Microelectrónica de Barcelona Gallium Implantation. Electrical Characterization. C(V). 1/C 2 C(V): On Wafer LGAD devices with Gallium Multiplication Layer have similar C(V) characteristics than PiN Detectors. We do not observe the multiplication layer depletion

Status of CNM RD50 LGAD Project27th RD50 Workshop, CERN 2-4 Dec Centro Nacional del MicroelectrónicaInstituto de Microelectrónica de Barcelona Gallium Implantation. GEANT4 Simulation 60 keV z mean = 19,58 nm (mpv ≈ 22 nm) 100 keV z mean = 39,46 nm (mpv ≈ 48 nm) 120 keV z mean = 51,22 nm (mpv ≈ 61 nm) 180 keV z mean = 90,87 nm (mpv ≈ 107 nm) 35 nm SiO 2 Si

Status of CNM RD50 LGAD Project27th RD50 Workshop, CERN 2-4 Dec Centro Nacional del MicroelectrónicaInstituto de Microelectrónica de Barcelona 35 nm SiO 2 60 keV Geant4 final position vs SRIM range 19,58 vs 46,6 nm Active Gallium Substrate Doping Active Boron GEANT4 SILVACO SRIM

Status of CNM RD50 LGAD Project27th RD50 Workshop, CERN 2-4 Dec Centro Nacional del MicroelectrónicaInstituto de Microelectrónica de Barcelona Work plan for Ga implantations  New fabrication run.  Pad diodes with P-junction made of Ga  Test structures to calibrate simulation and ion implantation and diffusion.  Different ion implantation energies will be used.

Status of CNM RD50 LGAD Project27th RD50 Workshop, CERN 2-4 Dec Centro Nacional del MicroelectrónicaInstituto de Microelectrónica de Barcelona Conclusions  1st project on LGAD fabricated in epitaxyal wafers can be considered concluded.  2nd project on thin LGAD detectors is in progress. Designing the mask.  3rd project on LGAD detectors fabricated with Ga will be submitted in this workshop

Status of CNM RD50 LGAD Project27th RD50 Workshop, CERN 2-4 Dec Centro Nacional del MicroelectrónicaInstituto de Microelectrónica de Barcelona Thank you for your attention !!!!