Infrastructure for LHCb Upgrade workshop – MUON detector Infrastructure for LHCB Upgrade workshop: MUON power, electronics Muon upgrade in a nutshell LV.

Slides:



Advertisements
Similar presentations
M.PEGORARO Grounding Workshop 24th Jan 08 DT GROUNDING & SHIELDING Presented by A. BENVENUTI.
Advertisements

Bagby L0 Workshop L0 Infrastructure  Mapping  Installations u Horseshoe Area s Adapter Card u Cathedral s Low Voltage Fuse Panel u Platform s.
Tullio Grassi ATLAS–CMS Power Working Group 31 March 2010 DC-DC converters and Power Supplies requirements for CMS HCAL Phase 1 Upgrade.
Power supply planning for upgrade OT  Scintillating Fibre Wilco Vink On behalf of the SciFi group 19 May 2014.
TRT DCS overview Elzbieta Banas Zbigniew Hajduk Jolanta Olszowska (INP PAS Cracow) ID Week /TRT Operation1.
Experimental Area Meeting V. Bobillier1 Good connection to earth (in many points) of every metallic parts to be installed in the cavern is very.
Infrastructure for LHCb Upgrade workshop – MUON detector Infrastructure for LHCB Upgrade workshop: MUON power, electronics, cable Muon upgrade in a nutshell.
Low Voltage Power Requirement of TOF FEEs. Maximum tray. Low Noise:  Periodic and Random Distortion (PARD) < few mV RMS Floating.
The High Voltage, Monitoring and Control systems of the Hadronic and Electromagnetic calorimeters are essentially slow control based, and therefore are.
ECS for Front-End crates MARATON. 2 Introduction Front-End crates are powered by MARATON power supplies, located on the platform, at the back of each.
Saverio Minutoli INFN Genova 1 1 T1 Electronic status Electronics Cards involved: Anode Front End Card Cathode Front End Card Read-Out Control card VFAT.
Readout electronics for the MUV detectors R. Fantechi 28/3/2012.
LHCb F. Murtas Servizio elettronica G. Corradi D.Tagnani P.Ciambrone HV_GEM per LHCB M1R1 HV power supply Introduction Introduction HV_GEM Technical specification.
Anatoli Konoplyannikov Design and integration of HV, LED monitoring and calibration system for HCAL Overview of the subsystems design High voltage.
LKr Calorimeter Control and monitoring R. Fantechi 19/02/2010 R. Fantechi.
Status of NA62 straw electronics and services Peter LICHARD, Johan Morant, Vito PALLADINO.
1 5 December 2012 Laurent Roy Infrastructure / Electronics Upgrade -Cabling (long distance) -Rack and Crate (space, electrical distribution, cooling) -Detector.
ALICE DCS Workshop 28/29 May 2001 Vito Manzari, INFN Bari SSD (Silicon Strip Detector) SDD (Silicon Drift Detector) SPD (Silicon Pixel Detector) Detector.
Straw Electronics status and preparation for the technical run NA62 workshop Siena.
Alex Madorsky University of Florida/Physics Track Finder production readiness review, Rice, August 2004 Track Finder Crate, Backplane and Parts Alex Madorsky.
Problems with Muon System N. Bondar O.Maev
Goals: - To get experience in assembling MWPC on the Wall and prevent possible problems; - To check functionality and stability of different chambers at.
ECS for Front-End crates MARATON. 2 Introduction Front-End crates are powered by MARATON power supplies, located on the platform, at the back of each.
Muon Electronics Upgrade Present architecture Remarks Present scenario Alternative scenario 1 The Muon Group.
Paolucci INFN-Napoli Muon Annul Review Cern 15 September 2003 RPC cabling HV & LV cables Signal cables Position and composition of racks in UXC and USC.
NUMI Off Axis NUMI Off Axis Workshop Workshop Argonne Meeting Electronics for RPCs Gary Drake, Charlie Nelson Apr. 25, 2003 p. 1.
Status of NA62 straw electronics Webs Covers Services Readout.
CARDIAC meeting – 30 Sept 05 M3R3-M5R3-M5R4 FEE status.
cm 150 cm The Al foil is large as the M3 wall  we can put 1 raw (5 chambers) or 2 raws There is an insulating material (varnish) on the.
Total Cross Section, Elastic Scattering and Diffraction Dissociation at the LHC January 17, 2003TOTEM plenary meeting -Marco Bozzo1 CSC detectors for T1.
K.WyllieElectronics meeting 29/05/061 RICH Power Supplies & Grounding Thanks to Johan Morant Paolo Baesso Xavier Le Gouard.
DT Shifter Training Infrastructure A. Benvenuti, M.Giunta 07/07/2010.
CSC ME1/1 Patch Panel Interconnect Board (PPIB) Mikhail Matveev Rice University February 27, 2013.
Connector Differential Receiver 8 Channels 65 MHz 12 bits ADC FPGA Receive/buffer ADC data Format triggered Events Generate L1 Primitives Receive timing.
Muon Piquet Training V.0 W Baldini, E.Furfaro, O. Maev June 11-th 2015.
9/18/2003Safety Review Electronics Electronics design LV, HV power supply Fusing Heat.
9/17/2008TWEPP 2008, R. Stringer - UC Riverside 1 CMS Tracker Services: present status and potential for upgrade Robert Stringer University of California,
Could we abandon the HW LLT option and save money (and allow possible further improvements to the upgraded muon system)? Alessandro Cardini of behalf of.
IB PRR PRR – IB System.
SPD VFE installation and commissioning (status and plans) I.Summary of VFE installation II.Stand alone VFE test: noise & offset III.Stand alone test: LED.
Distributed Low Voltage Power Supply System for Front End Electronics of the TRT Detector in ATLAS Experiment E.Banaś a, P.Farthouat b, Z.Hajduk a, B.Kisielewski.
Summary of FEE-Integration Meeting LNF, Summary of the Frascati meeting on chamber & front-end integration on 10 September 2003, provided.
CERN – 7 Oct 04 1 LHCb Muon Grounding Anatoli Katchouk CERN Alessandro Balla, Paolo Ciambrone, Maurizio Carletti, Giovanni Corradi, Giulietto Felici, Rosario.
TOF status and LS1 plansTOF status and LS1 plans 27/06/2012.
DCS workshop,march 10th P.Saturnini, F. Jouve Slow control trigger of the muon arm Muon trigger of the muon arm Low voltage VME Crate External parameters.
1 DCS Meeting, CERN (vydio), Jun 25th 2013, A. Cotta Ramusino for INFN and Dip. Fisica FE Preliminary DCS technical specifications (v1.0) for the Gigatracker.
1 Chamber Interfaces Adalberto Readout-, I2C-, HV-, LV-, Gas- and chamber support interface. Space issues.
Faculty of Physics, University of Belgrade Collaboration meeting, Budapest 15 th of May, ToF-L/R detector HV upgrade Jovan Puzović, Faculty of Physics,
Faculty of Physics, University of Belgrade Collaboration board meeting 31 th of January, ToF-L/R detector HV upgrade Jovan Puzović, Faculty of Physics,
Martin van Beuzekom, Jan Buytaert, Lars Eklund Opto & Power Board (OPB) Summary of the functionality of the opto & power board.
2 Dec 1998F Harris LHCb Trigger Meeting L0 Trigger - ‘Real Estate’ Considerations Current thinking for the size and location of L0 trigger electronics,
Faculty of Physics, University of Belgrade Collaboration meeting, Dubna 8 th of April, ToF-LR Upgrade Jovan Puzović, Faculty of Physics, Belgrade.
Belle-II bKLM RPC Readout Power & Ground Discussion 12 th Belle II General Meeting Gerard Visser Indiana University CEEM 7/24/2012.
HF ROBOX PRR3 Apr 2003E. Hazen HF Front-End Electronics ● System Description – Overview – PMT Board, ROBOX, Patch Panel – Signal Cable, Front-end boards.
LHCb Outer Tracker Electronics 40MHz Upgrade
Cabling for LHCb Upgrade
LKr status R. Fantechi.
Rack Design Proposal as of 01/03/2013
Upgrade activities at Clermont-Ferrand
General aspects: Optical links :
T1 Electronic status Conclusions Electronics Cards:
ALICE Muon Tracking Upgrade EDR Answers
Electronics for RPC Upscope
To do list production organization and commitments
Pierluigi Paolucci - I.N.F.N. Naples
RPC HV&LV status Introduction HV power supply tender
Overview of T1 detector T1 is composed by 2 arms
Track Finder Crate, Backplane and Parts
RPC Detector Control System: towards the final system
Pierluigi Paolucci & Giovanni Polese
Presentation transcript:

Infrastructure for LHCb Upgrade workshop – MUON detector Infrastructure for LHCB Upgrade workshop: MUON power, electronics Muon upgrade in a nutshell LV power scheme HV power scheme Optical fibers connections Conclusions

Infrastructure for LHCb Upgrade workshop – MUON detector Remove M1 station Preserve the present MWPCs and their front-end electronics in M2-M5 stations –to improve the detector performances at high luminosity, the replacement of the innermost chambers of M2 and M3 with high granularity detectors is under study Maintain the present Intermediate Board (IB) system (with the exception of M5R4) to generate the logical channels Use new Off Detector Electronics (nODE) boards for an efficient 40 MHz –Back compatible with the current off detector electronics and crates –Based on new custom ASIC (nSYNC), GBT and versatile link components Replace the Service Board (SB) system –Efficient chamber pulsing (nPDM) and control (nSB) via GBT and versatile link components Muon upgrade in a nutshell 2 19/02/2015

Infrastructure for LHCb Upgrade workshop – MUON detector Based on Maraton System –Primary rectifiers and Remote Controllers in a safe environment (behind the wall) –Long cables + patch panels (in a fixed position) + movable cable chain –Power boxes on each rack of the muon towers Front-end electronics (FEE) powering scheme –Maraton power box + patch panel (rack) + linear regulator (on detector) Each FEE power box has V/55A (330 W maximum) –8 FEE power boxes installed (2 for M1, 4 for M2-M3, 2 for M4-M5) Present maximum power consumption per power box ~ 2kW Present maximum power (current) consumption per channel –~ 172 W (43A) in M4-M5 –~ 130 W (34A) in M2-M3 Current LV power scheme: FEE 3 19/02/2015

Infrastructure for LHCb Upgrade workshop – MUON detector Off detector electronics powering scheme –1 Maraton power box per rack Up to 4 crates (IB, ODE, SB) per power box Each power box has –2 2..7V/110A (660 W) –8 2..7V/55 A (330 W) –10 off detector electronics power boxes installed (2 for M1, 4 for M2-M3, 4 for M4-M5) Present maximum power consumption per power box ~ 500 W Current LV power scheme: off det. Electronics 4 19/02/2015

Infrastructure for LHCb Upgrade workshop – MUON detector Upgraded power system will use the current Maraton System components and cables –M1 will be removed All system components can be used as spares –M2-M5 FEE power boxes No changes foreseen –6 FEE power boxes + 6 patch panels required (in the racks of the muon towers -UXB) –Enough margin to handle a potential power increase with the rate In case of innermost M2-M3 chambers replacement 2 more power boxes should be foreseen –M2-M5 off detector electronics power boxes No changes foreseen –8 power boxes required (in the racks of the muon towers- UXB) –The new nODE, nSB and nPDM boards will use the current rack power lines and they will generate internally the new required voltages –Current power is enough »A local (rack level) power line reshuffling for the high power channels could be needed –14 (+2) AD/DC primary rectifiers in 4 power boxes (in the rack behind the wall – UXA-B) No changes foreseen –14 RCM (+2) controller modules in 2 VME like crates (in the rack behind the wall – UXA-B) No changes foreseen –Current cabling can be maintained In case of innermost M2-M3 chambers replacement 2 more power and control cables should be installed Upgraded LV power scheme 5 19/02/2015

Infrastructure for LHCb Upgrade workshop – MUON detector No changes are foreseen in the high voltage systems and cabling (just remove the M1 components) –CAEN EASY 3000 In a safe environment –1 SY1527LC Mainframe –2 A1676 branch controllers –2 A V Power supplies –1 Local patch panel On detector –2 cavern patch panels + cable chain –4 EASY3000 crates –18 A3535 HV modules Upgraded HV power scheme 6 19/02/2015

Infrastructure for LHCb Upgrade workshop – MUON detector Present Conditions 7 19/02/2015 *Present power requirements* Front-end Electronics: * 8 maraton power boxes: 2 for M1, 4 for M2-M3, 2 for M4-M5 * maximum power consumption per power box ~ 2kW Off detector electronics * 10 maraton power boxes (1 per racks): 2 for M1, 4 for M2-M3, 4 for M4-M5 * maximum power consumption per power box ~ 500 W o each ODE ~ 23 W (56% of max power box consumption) o each SB ~ 2,5W (9% of max power box consumption) o each IB ~ 3W (35% of max power box consumption)

Infrastructure for LHCb Upgrade workshop – MUON detector Upgrade Conditions 8 19/02/2015 Front-end Electronics: No changes foreseen Off detector electronics * estimated max power consumption o each nODE +17% --> + 48 W per rack (worst case) o each nSB +60% --> +27 W per rack (worst case) o each IB ~3W (No changes foreseen) Therefore we could have an increase of max 75 W per rack (but this is a worst case estimation, because we don't know the correct nSYNC requirements) * HV Power requirements* We do not expect to have an increase in power requirements, since the system will not be changed

Infrastructure for LHCb Upgrade workshop – MUON detector No change required in crates and racks on the muon towers No major change foresees for LV power system –Re-use present Maraton components for frond-end electronics and off detector electronics power supply –Existing electrical power seem enough –Present cabling could be maintained –2 new power boxes and cables should be installed in case of innermost M2-M3 chambers replacement No change foresees for HV power system Conclusions 9 19/02/2015