MEDT8002 Ultralyd bildediagnostikk Faglærer: Hans Torp Institutt for sirkulasjon og bildediagnostikk Hans Torp NTNU, Norway.

Slides:



Advertisements
Similar presentations
TV/TVM Tissue Doppler … Introducing Tissue Doppler What is it ?
Advertisements

MEDT8002 Blood flow measurement by Doppler technique Hans Torp Institutt for sirkulasjon og medisinsk bildediagnostikk Hans Torp NTNU, Norway.
TTK 4165 Signalbehandlingsteknikker i medisinsk bildediagnostikk
MEDT8007 Simulering av ultralydsignal fra spredere i bevegelse Hans Torp Institutt for sirkulasjon og medisinsk bildediagnostikk Hans Torp NTNU, Norway.
Doppler Echocardiography
Doppler Echocardiography
Doppler Ultrasound: Principles
Non-linear acoustics in Ultrasound Imaging Hans Torp Department of Physiology and Biomedical Engineering NTNU NTNUNorway Hans Torp NTNU, Norway.
7. Radar Meteorology References Battan (1973) Atlas (1989)
إعداد : أ. بلسم فهد صوفي 1 Ultrasound in Medicine Ch.3 Ultrasound pictures of the body.
Handbook of Medical Informatics
Mostafa Eladawy MD,AFSA Basics of Echocardiography.
إعداد : أ. بلسم فهد صوفي،،،المصدر:محاضرات د.حنان 1 Ultrasound in Medicine Ch.4 Ultrasound pictures of the body.
1 Hough transform Some Fourier basics: –Nyquist frequency: 1/2 , with  the difference between time samples. If signal is bandwidth limited below Nyquist.
Hospital Physics Group
ECE 501 Introduction to BME
Specular reflectorquasi-specular reflector quasi-Lambert reflector Lambert reflector Limiting Forms of Reflection and Scatter from a Surface.
- Doppler Ultrasound & Obstetrical Ultrasound
Ultrasound Imaging Atam Dhawan.
ECHO/ DOPPLER CARDIOGRAPHY A diagnostic Study that reveals information about: The structure and function of the heart Cardiac hemodynamics of the heart.
Radar: Acronym for Radio Detection and Ranging
Welcome.
DOPPLER SONOGRAPHY By Dr/ Dina Metwaly.
THE ULTRASOUND IMAGE: GENERATION AND DISPLAY
Doppler Radar From Josh Wurman NCAR S-POL DOPPLER RADAR.
Doppler Radar From Josh Wurman Radar Meteorology M. D. Eastin.
Ultrasonography.
Profilers. Wind profilers are phased array radars that measure the wind as a function of height above a fixed location. Characteristics: Wavelength: 33.
Your Name Your Title Your Organization (Line #1) Your Organization (Line #2) Week 4 Update Joe Hoatam Josh Merritt Aaron Nielsen.
Decomposition of flow signals into basis functions: Performance advantages, disadvantages, and computational complexity Hans Torp and Lasse Løvstakken.
Radar equation review 1/19/10. Radar eq (Rayleigh scatter) The only variable is h, the pulse length Most radars have a range of h values. Rewrite the.
Ultrasound. Sound waves Sounds are mechanical disturbances that propagate through the medium Frequencies
Display of Motion & Doppler Ultrasound
Resident Categorical Course
1 March 2013 PGI Chandigarh Dr Sarvesh Natani.
BMI 1 FS05 – Class 8, “US Instrumentation” Slide 1 Biomedical Imaging I Class 8 – Ultrasound Imaging II: Instrumentation and Applications 11/02/05.
Display of Motion & Doppler Ultrasound
Review of Ultrasonic Imaging
One Specific Velocity Color Mapping of Flows with Complex Geometry Biomedical Engineering, Tambov State Technical University, Russia S.G.Proskurin, A.Yu.Potlov,
Sarah Gillies Ultrasound Sarah Gillies
Ultrasound Imaging Basic Principle: sound wave pulse emitted at >20 kHZ, some reflected, and some transmitted. Reflection from single signal – A-scan Reproduced.
Doppler Ultrasound Dr Mohamed El Safwany, MD.. Introduction The Doppler Effect refers to the change in frequency that results when either the detector/observer.
Saudi Board of Radiology: Physics Refresher Course Kostas Chantziantoniou, MSc 2, DABR Head, Imaging Physics Section King Faisal Specialist Hospital &
Quantifying Cardiac Deformation by strain (-rate) imaging Hans Torp NTNU, Norway Hans Torp Department of Circulation and Medical Imaging Norwegian University.
Phonocardiography, External Pulse Recordings, and Echocardiography
TTK4165 Color Flow Imaging Hans Torp Department of Circulation and Medical Imaging NTNU, Norway Hans Torp NTNU, Norway.
S.Frasca on behalf of LSC-Virgo collaboration New York, June 23 rd, 2009.
Oelze - ECE 571 Lecture 4 Biological Measurement 1 BIOE 571.
Ultrasound Basis Michel Slama Amiens.
Artifacts Ultrasound Physics George David, M.S.
Performance Issues in Doppler Ultrasound 1. 2 Fundamental Tradeoffs In pulsed modes (PW and color), maximum velocity without aliasing is In pulsed modes,
1 Opto-Acoustic Imaging 台大電機系李百祺. 2 Conventional Ultrasonic Imaging Spatial resolution is mainly determined by frequency. Fabrication of high frequency.
Cardiac Shear Wave Elastography Using a Clinical Ultrasound System
BME 312 BIOMEDICAL INSTRUMENTATION II LECTURER: ALİ IŞIN
Doppler Spectral Analysis
Lecture on Ultrasonography
Ultrasound.
Visit for more Learning Resources
Clutter filtering in color flow imaging
MTI RADAR.
Doppler Radar Basics Pulsed radar
“How To” record uterine artery Doppler at 11–13 weeks
MCQs (1) – Questions Ultrasound propagates through the medium as a transverse wave Ultrasound velocity is equal to the product of frequency and wavelength.
Review of Ultrasonic Imaging
Advanced Radar Systems
1. Doppler Effect Change in frequency of a wave due to relative motion between source and observer. A sound wave frequency change is noticed as a change.
Radio Propagation Review
DOPPLER ARTIFACTS.
Ultrasonic Imaging Using Contrast Agents
Presentation transcript:

MEDT8002 Ultralyd bildediagnostikk Faglærer: Hans Torp Institutt for sirkulasjon og bildediagnostikk Hans Torp NTNU, Norway

New development in color Doppler “Blood motion imaging” Arteria bracialis Conventional Color Doppler Arteria bracialis Blood motion imaging Carotis communis Blood motion imaging Hans Torp NTNU, Norway

University(NTNU) - Industry(Vingmed) 1986 CFM 700 First color Doppler with mechanical scanning Beam- adder    BFx 1995 System Five Digital beam former >Higher framerate >RF-data for research >Tissue Doppler 2000 Vivid 7 Real-time processing with PC technology

Data acquistion in color flow imaging Beam k-1Beam k Beam k+1 Number of pulses in each direction 3 – 15 Frame rate reduction compared to B-mode

2D Color flow imaging 1. Limited information content in the signal, i.e. short observation time, low signal-to-noise ratio, and low Nyquist velocity limit. 2.Insufficient signal processing/display. Full spectrum analysis in each point of the sector is difficult to visualize.

Color mapping types Hans Torp NTNU, Norway Power Doppler (Angio) Brightnes ~ signal power Color flow Brightnes ~ signal power Hue ~ Velocity Color flow ”Variance map” Hue & Brightnes ~ Velocity Green ~ signal bandwidth

Color scale for velocity and - spread Power Band width Aortic insufficiency Hans Torp NTNU, Norway

Color flow imaging Mitral valve blood flow Normal mitral valve Stenotic mitral valve Hans Torp NTNU, Norway

Autocorrelation method Sensitive to clutter noise Phase angle of R(1) substantially reduced due to low frequency clutter signal Clutter filter stopband much more critical than for spectral Doppler

How to perform clutter filter in color flow imaging? Beam k-1Beam k Beam k+1

How to perform clutter filter in color flow imaging? Beam k-1Beam k Beam k+1

Color flow scanning strategies B-mode scanning Mechanical scanning + No settling time clutter filter - low frame rate Electronic scanning Packet acquisition - Settling time clutter filter +flexible PRF without loss in frame rate Electronic scanning continuous acquisition + no settling time clutter filter + High frame rate - low PRF (=frame rate) scanning direction time

Color flow imaging with a mechanical probe v = W*FR Image width W Frame rateFR Sweep velocityv= W*FR Virtual axial velocity: vr= v*cotan(  ) vr v  Example: Image width W = 5 cm Frame rateFR =20 fr/sec Angle with beam  = 45 deg. Sweep velocityv= 1 m/s Virtual axial velocity: vr= 1 m/s vr > max normal blood flow velocities!

Color flow imaging with a mechanical probe W= N*b v = W*FR Beamwidth (Rayleigh criterion): b Effective number of beams: N =W/b Frame Rate: FR Signal from stationary scatterer N*Fr*t Clutter signal bandwidth: 2*N*FR Power spectrum Clutter filter cutoff frequency: fc > N*FR Frequency components < fc removed

Minimum detectable Doppler shift Frame rate FR =1 Hz FR = 10 Hz FR=20 Hz Width (# beams) N=3030 Hz300 Hz 600 Hz N=7070 Hz700 Hz1400 Hz Clutter filter cutoff frequency: fc > N*FR (transit time effect mechanical scan) Cardiac flow imaging: fo= 2 MHz, 15 mm aperture, beamwidth 3 mm 30 beams covers the left ventricle fc = 600 Hz ~ 0.21 m/sec. lower velocity limit

Color flow imaging with a mechanical probe v = W*FR Reflected wave does not hit the transducer Max Dopplershift 600 Hz ~ 0.21 m/sec

Atlanta, GA april 1986 Vingmed, introduced CFM The first commercial colorflow imaging scanner with mechanical probe Horten, Norway september 2001 GE-Vingmed closed down production line for CFM after 15 years of continuous production

Minimum detectable Doppler shift Clutter filter cutoff frequency: fc > N*FR Frame rate FR =1 Hz FR = 10 Hz FR=20 Hz Width (# beams) N=3030 Hz300 Hz 600 Hz N=7070 Hz700 Hz1400 Hz Periferal vessel imaging with fo= 10 MHz Mechanical scanning: fc = 1400 Hz ~ 108 mm/sec. Electronic scanning: fc = 30 Hz ~ 2.3 mm/sec. Packet acquisition (P=10): Frame rate = 35 frames/sec Continuous acquisition:Frame rate = 350 frames/sec

Combining tissue and flow Continuous sweep acquisition + Brachial artery

Temporal averaging for mean frequency estimator Example: Effect of averaging R1 : Variance of angle(R1) reduced by factor 24! Effect of averaging angle(R1): Variance reduction factor=4 k=1 : 4, uncorrelated signal packets