J. S. MarshallCost-effective ECAL1 ECAL Simulation Studies – Overview Wednesday 30 th January 2013 J. S. Marshall University of Cambridge.

Slides:



Advertisements
Similar presentations
CBM Calorimeter System CBM collaboration meeting, October 2008 I.Korolko(ITEP, Moscow)
Advertisements

LC Calorimeter Testbeam Requirements Sufficient data for Energy Flow algorithm development Provide data for calorimeter tracking algorithms  Help setting.
1 AHCAL answers IDAG Erika Garutti On behalf of AHCAL analysis team.
P. Gay Energy flow session1 Analytic Energy Flow F. Chandez P. Gay S. Monteil CALICE Coll.
1 Study of the Tail Catcher Muon Tracker (TCMT) Scintillator Strips and Leakage with Simulated Coil Rick Salcido Northern Illinois University For CALICE.
Testbeam Requirements for LC Calorimetry S. R. Magill for the Calorimetry Working Group Physics/Detector Goals for LC Calorimetry E-flow implications for.
Ties Behnke, Vasiliy Morgunov 1SLAC simulation workshop, May 2003 Pflow in SNARK: the next steps Ties Behnke, SLAC and DESY; Vassilly Morgunov, DESY and.
Some early attempts at PFA Dhiman Chakraborty. LCWS05 Some early attempts at PFA Dhiman Chakraborty2 Introduction Primarily interested in exploring the.
 Track-First E-flow Algorithm  Analog vs. Digital Energy Resolution for Neutral Hadrons  Towards Track/Cal hit matching  Photon Finding  Plans E-flow.
PFA Development – Definitions and Preparation 0) Generate some events w/G4 in proper format 1)Check Sampling Fractions ECAL, HCAL separately How? Photons,
Cluster finding in CALICE calorimeters Chris Ainsley University of Cambridge, UK General CALICE meeting: simulation/reconstruction session 28  29 June.
Track Extrapolation/Shower Reconstruction in a Digital HCAL – ANL Approach Steve Magill ANL 1 st step - Track extrapolation thru Cal – substitute for Cal.
Michele Faucci Giannelli TILC09, Tsukuba, 18 April 2009 SiW Electromagnetic Calorimeter Testbeam results.
Photon reconstruction and calorimeter software Mikhail Prokudin.
John Marshall, 1 John Marshall, University of Cambridge ILD Workshop, LAL Orsay, May
Study of response uniformity of LHCb ECAL Mikhail Prokudin, ITEP.
Progress with the Development of Energy Flow Algorithms at Argonne José Repond for Steve Kuhlmann and Steve Magill Argonne National Laboratory Linear Collider.
Development of Particle Flow Calorimetry José Repond Argonne National Laboratory DPF meeting, Providence, RI August 8 – 13, 2011.
The CALICE Si-W ECAL - physics prototype 2012/Apr/25 Tamaki Yoshioka (Kyushu University) Roman Poschl (LAL Orsay)
The Scintillator ECAL Beam Test at FNAL K. Kotera, Shinshu-u, 1st October 2009 CALICE Scintillator ECAL group; Kobe University, Kyungpook University, the.
Summary of Simulation and Reconstruction Shaomin CHEN (Tsinghua University)  Framework and toolkit  Application in ILC detector design Jupiter/Satellites,
International Workshop on Linear Colliders, Geneve Muon reconstruction and identification in the ILD detector N. D’Ascenzo, V.Saveliev.
Pion Showers in Highly Granular Calorimeters Jaroslav Cvach on behalf of the CALICE Collaboration Institute of Physics of the ASCR, Na Slovance 2, CZ -
Development of a Particle Flow Algorithms (PFA) at Argonne Presented by Lei Xia ANL - HEP.
Cluster finding in CALICE calorimeters Chris Ainsley University of Cambridge, UK LCWS 04: Simulation (reconstruction) parallel session 20 April 2004, Paris,
Optimizing the SiD Detector - mainly a calorimeter perspective Andy White SiD Advisory May 5, 2008.
UTA GEM DHCAL Simulation Jae Yu * UTA DoE Site Visit Nov. 13, 2003 (*On behalf of the UTA team; A. Brandt, K. De, S. Habib, V. Kaushik, J. Li, M. Sosebee,
Pandora calorimetry and leakage correction Peter Speckmayer 2010/09/011Peter Speckmayer, WG2 meeting.
Positional and Angular Resolution of the CALICE Pre-Prototype ECAL Hakan Yilmaz.
R&D status of the Scintillator- strip based ECAL for the ILD Oct LCWS14 Belgrade Satoru Uozumi (KNU) For the CALICE collaboration Scintillator strips.
CBM ECAL simulation status Prokudin Mikhail ITEP.
Taikan Suehara, Belgrade, 7 Oct page 1 Hybrid ECAL: optimization and related developments Taikan Suehara H. Hirai, H. Sumida, Y. Sudo, T.
1ECFA/Vienna 16/11/05D.R. Ward David Ward Compare these test beam data with Geant4 and Geant3 Monte Carlos. CALICE has tested an (incomplete) prototype.
PFAs – A Critical Look Where Does (my) SiD PFA go Wrong? S. R. Magill ANL ALCPG 10/04/07.
13 July 2005 ACFA8 Gamma Finding procedure for Realistic PFA T.Fujikawa(Tohoku Univ.), M-C. Chang(Tohoku Univ.), K.Fujii(KEK), A.Miyamoto(KEK), S.Yamashita(ICEPP),
CALOR April Algorithms for the DØ Calorimeter Sophie Trincaz-Duvoid LPNHE – PARIS VI for the DØ collaboration  Calorimeter short description.
1 D.Chakraborty – VLCW'06 – 2006/07/21 PFA reconstruction with directed tree clustering Dhiman Chakraborty for the NICADD/NIU software group Vancouver.
Ties Behnke: Event Reconstruction 1Arlington LC workshop, Jan 9-11, 2003 Event Reconstruction Event Reconstruction in the BRAHMS simulation framework:
John Marshall, 1 John Marshall, University of Cambridge LCD Meeting, December
John MarshallPandora Development1 J.S. Marshall University of Cambridge.
1 1 - To test the performance 2 - To optimise the detector 3 – To use the relevant variable Software and jet energy measurement On the importance to understand.
Calice Meeting Argonne Muon identification with the hadron calorimeter Nicola D’Ascenzo.
1 IWLC 2010 Geneva Oct.’10David Ward Tests of GEANT4 using the CALICE calorimeters David Ward  Electromagnetic particles (, e) were used to understand.
John Marshall, 1 John Marshall, University of Cambridge LCD Software Meeting, September
Mark Thomson University of Cambridge High Granularity Particle Flow Calorimetry.
Interactions of hadrons in the SiW ECAL (CAN-025) Philippe Doublet - LAL Roman Pöschl, François Richard - LAL SiW ECAL Meeting at LLR, February 8th 2011.
Régis Lefèvre (LPC Clermont-Ferrand - France)ATLAS Physics Workshop - Lund - September 2001 In situ jet energy calibration General considerations The different.
DESY1 Particle Flow Calorimetry At ILC Experiment DESY May 29 th -June 4 rd, 2007 Tamaki Yoshioka ICEPP, Univ. of Tokyo Contents.
J. S. MarshallPandora PFA1 Pandora Particle Flow Calorimetry Tuesday 29 th January 2013 J. S. Marshall University of Cambridge.
Energy Reconstruction in the CALICE Fe-AHCal in Analog and Digital Mode Fe-AHCal testbeam CERN 2007 Coralie Neubüser CALICE Collaboration meeting Argonne,
John Marshall, 1 John Marshall, University of Cambridge LCD-WG2, July
 reconstruction and identification in CMS A.Nikitenko, Imperial College. LHC Days in Split 1.
John Marshall, 1 John Marshall, University of Cambridge LCD WG6 Meeting, February
Hadrons in a SiW Electromagnetic Calorimeter for a Future Linear Collider Roman Pöschl LAL Orsay LHC EUDET Annual Meeting DESY Hamburg September/October.
Taikan Suehara, Belgrade, 7 Oct page 1 Hybrid ECAL: optimization and related developments Taikan Suehara H. Hirai, H. Sumida, Y. Sudo, T.
SiD Calorimeter R&D Collaboration
CALICE scintillator HCAL
slicPandora: slic + pandoraPFANew
Panagiotis Kokkas Univ. of Ioannina
Studies with PandoraPFA
Detector Configuration for Simulation (i)
ILD Optimisation: towards 2012 University of Cambridge
Individual Particle Reconstruction
Simulation study for Forward Calorimeter in LHC-ALICE experiment
Rick Salcido Northern Illinois University For CALICE Collaboration
Argonne National Laboratory
Michele Faucci Giannelli
Status of CEPC HCAL Optimization Study in Simulation LIU Bing On behalf the CEPC Calorimeter working group.
Steve Magill Steve Kuhlmann ANL/SLAC Motivation
LC Calorimeter Testbeam Requirements
Presentation transcript:

J. S. MarshallCost-effective ECAL1 ECAL Simulation Studies – Overview Wednesday 30 th January 2013 J. S. Marshall University of Cambridge

J. S. MarshallCost-effective ECAL2 Previous ECAL Studies 20 x 2.1mm + 9 x 4.2mm W, with 29 x 0.5mm Si Silicon cells: 5.1 x 5.1mm 2 ECAL in CLIC_ILD_CDR, sampling calorimeter, 23 X 0, 1 I Role of ECAL is to measure energies of individual photons and early parts of hadronic showers. Photons may be close together, or may overlap with charged hadrons. Require fine segmentation to allow separation. Tracker ECALHCAL

J. S. MarshallCost-effective ECAL3 Previous ECAL Studies Calibration constants for each pad were determined using muon events. The response of each cell was fitted by a convolution of a Landau distribution with a Gaussian. The most probable value of the underlying Landau function was taken to define the MIP value for each cell, and the raw energy for each cell in data was corrected to units of MIPs. Si-W ECAL Sc-W ECAL Si-W ECAL Hybrid, MC Prototype Si-W ECAL installed and tested at CERN during ,480 Si pads, dimensions 1.0x1.0cm 2 and thickness 0.5mm. 30 W layers, thickness: 10x1.4mm, 20x2.8mm. 24X 0 at normal incidence. Setup simulated with Mokka. ScECAL prototype beam-test at FNAL in 2008, e, ,  beams. 30 pairs of Sc (3mm) and W absorber (3.5mm) layers. Scintillator strips of alternating alignment: 4.5x1.0cm 2.

J. S. MarshallCost-effective ECAL4 Important aim for new ECAL studies is to ensure that different detector models are examined in a well-defined manner. Want to assess intrinsic physics performance offered by each model. Ultimately interested in the optimal jet energy resolution achievable using each detector model, but need to separate software performance issues from underlying “detector ability”: Must isolate effects of calibration changes, May need to re-optimise particle flow algorithms and/or reduce their dependence on geometry, Need to develop standard procedures for measuring ECAL performance. Once this has been completed, can start to vary ECAL parameters and observe resulting changes in performance. Reasonably large number of parameters to investigate: Si/Sc ratio, Si/Sc cell sizes and thicknesses, absorber thicknesses, number of layers... Require studies to motivate (initial) values for these parameters. New “Cost-Effective ECAL” Studies

J. S. MarshallCost-effective ECAL5 Simulation Tools Simulation tools currently available: Mokka, SLIC Mokka has hybrid ECAL driver available, SECAL04. Angela will discuss status of this driver today. Will most-likely want to use this driver for simulation studies. Therefore need to understand this driver and to add any configuration options required for these studies, aiming for full layer-by-layer configuration of ECAL. However, it is apparently very quick and easy to generate simple calorimeter stack models using SLIC; may prove useful for shower-shape studies and calibration work. Thoughts about digitisation?

J. S. MarshallCost-effective ECAL6 Characterisation Tools Single particle studies, measuring intrinsic calorimetric resolution No processing of events required Simple particle reconstruction, involving basic pattern-recognition E.g.  0 mass reconstruction, separation of  decay modes, etc. Full particle flow reconstruction of jet energies and masses The most important characterisation approach is to obtain the jet energy resolution. Off-shell Z bosons are produced at rest at different centre-of-mass energies. These decay into light quarks and typically produce two back-to-back mono-energetic jets. No jet- finding required to assess jet energy resolution, which can be obtained from total event energy. Do we need any other characterisation tools? Yes, unless we are sure that the final results are not biased by particle flow reconstruction algorithms optimised for the SiW ECAL design. Better indication of physics performance Reduced bias from software treatment

J. S. MarshallCost-effective ECAL7 Characterisation Tools Assessment using basic PFA procedures could include: Investigation of mass reconstruction performance for single  0 and single  samples. Investigates intrinsic ability to resolve photon pairs and to separate nearby photon and charged pion. Investigation of ability to separate decay modes  and  a 1. For ILD LoI, this was performed using HZ events (  ), producing invariant mass and selection matrix shown. If use full PFA, can examine constituents of reconstructed jets: simulated vs. reconstructed photon energy; photon energy merged with hadrons, etc. Volunteers required!

J. S. MarshallCost-effective ECAL8 Impact on PFA Pandora Client Apps Pandora Framework MarlinPandoraSlicPandora Run registered algorithms/tools and perform book-keeping Algorithm Manager CaloHit Manager Cluster Manager, etc. API Isolate detector and software details, creating self-describing hits, tracks, etc. Pandora Algorithms Access Pandora objects and carry out reconstruction API Clustering Track-cluster association Fragment Removal, etc. Pandora framework (detector-independent) provides “complicated” operations for algorithms, which perform the reconstruction. Most algorithms work with “hits” (defined positions/volumes), rather then referring to detector; should reduce impact of ECAL changes. Hits can be assigned to pseudolayers, which mirror detector structure. Algorithms may work with reference to e.g. layers spanned by clusters.

J. S. MarshallCost-effective ECAL9 Calibration for PFA PhotonsK0L Following any change to detector or reconstruction software, vital to update PFA calibration. Up to now, no formal procedure for performing calibration for ILD Pandora client app (MarlinPandora). Simply examined single-particle energy distributions, typically for 10GeV particles, to set constants: ECAL_To_EM_GeV ECAL_To_HAD_GeV HCAL_To_EM_GeV HCAL_To_HAD_GeV MUON_To_GeV In today’s session will discuss improved approaches; may require Pandora client app changes.

J. S. MarshallCost-effective ECAL10 PFA cannot remain a “Black-Box” EM shower expectation Observed longitudinal profile 1. Initial clustering: do EM showers now tend to form single clusters; are they split into multiple clusters; are they subsumed into charged particle clusters? Mu+ Photon 2. Are algorithms still configured correctly to recover EM showers from charged particle clusters? 3. Are algorithms still able to identify the correct neutral ECAL clusters as EM showers? Hardware determines granularity of the building-blocks available to particle flow reconstruction. Algorithms then simply tell computer how to process these building blocks. A change in granularity or in the energy deposition profiles may harm physics performance. Serious effort made to ensure algorithms are reasonably robust against sensible variations in detector. E.g. Algorithms place cuts on number of X 0, rather than absolute distances. However, no destruction testing. Need to look for problems whenever we change detector. Expect to be robust against variations in active material tile sizes, provided tiles remain square-faced. Photon-like cluster Mip-like cluster ECAL HCAL

J. S. MarshallCost-effective ECAL11 Current Status Current activities: Review of SECAL04 Mokka driver, with view to adding configuration parameters to allow layer- by-layer specification of Si/Sc active material, cell sizes, absorber and active layer thicknesses. ECAL stack simulations in SLIC, starting with full-Si and full-Sc models. Development of fixed calibration procedure will be a priority using these models. Would like to start in near future: Study of EM shower widths as a function of depth in the calorimeter. Could work at GEANT4 hit level, or could use fine-grained ECAL stack simulation. First single particle energy resolution studies. First performance characterisation, evaluation of ability to separate tau decay types. Would be “nice to have”: Motivate variation of absorber thicknesses as a function of calorimeter depth. Current 2.1/4.2mm W arrangement motivated by examination of photon energies in physics events. Performance characterisation, via  0 and  mass reconstruction, maybe without using Pandora?

J. S. MarshallCost-effective ECAL12 Procedure Long term goal, probably most interested in how quickly (in depth) can move from SiW to ScW Evaluate single particle energy resolutions for full SiW and ScW ECALs 2. Define hybrid ECAL models to study 3. Test and understand performance Iterate Develop Mokka SiW and ScW simulations Add configuration options to Mokka Develop calibration procedure Studies to motivate granularity Develop characterisation tools

J. S. MarshallCost-effective ECAL13 Summary Important to ensure that software-related issues do not cloud results from these studies. PFA no longer a “black box”, calibration and characterisation tools must be standardised. Need to ensure measured approach to developing ECAL models: avoid jumping to conclusions due to existing/past work in this area. Need communication with hardware studies people to ensure two groups don’t diverge. Must always keep cost in mind, e.g. will need to assess cost-impact of changes to ECAL outer radius. Decisions to make, volunteers to find, discussions to have during this week. During next month, need to make transition from initial planning to actually starting studies.

J. S. MarshallCost-effective ECAL14 BACKUP

J. S. MarshallCost-effective ECAL15 First ECAL Models In absence of results from relevant studies, would agree with suggestion of following models (with ongoing simulation development work for any orthogonal ideas): 1. Si-only ECAL, ensure can repeat, or better, expected performance using new tools. 2. Sc-only, in default configuration: 20 x 2.1mm + 9 x 4.2mm W, with 29 x 2mm scintillator Required for determination of calibration constants and good for comparison with full SiW ECAL 3. Hybrid ECAL, start with half-Si-half-scintillator: 15 x 2.1mm W, with 0.5mm Si + 14 x 3.2mm W, with 2mm scintillator, OR 15 x 2.5mm W, with 0.5mm Si + 14 x 3.0mm W, with 2mm scintillator Use new simulation tools and characterisation tools to assess performance obtained with these options. Begin to understand behaviour of particle flow reconstruction and progress from there... Should naturally lead to variation of number of layers, thicknesses of absorber material and sensitive material, variation of tile sizes, etc.

J. S. MarshallCost-effective ECAL16 PFA: EM Shower Id One aspect of particle flow reconstruction sensitive to changes in ECAL design is the identification of EM showers. Crucial to ensure that single photon/electron samples still identified correctly. Several complementary approaches used. For CLIC CDR, was mainly a single function responsible for controlling use of clusters in algorithms and the final decision to use EM or HAD energy measure. Attempt to make function robust against detector changes by using number of radiation lengths in front of each sampling layer. Should be OK, but will need checking for every detector model. Photon-like cluster Mip-like cluster Cuts applied to: Cluster mip-fraction Cluster fit direction and RMS Longitudinal energy profile: No. X 0 before shower max No. X 0 before layer 90 Transverse energy profile: Transverse distance 90 Longitudinal profile EM shower expectation Observed profile

J. S. MarshallCost-effective ECAL17 New algorithm designed to improve performance AND to concentrate photon reconstruction into a single location. Not available for CLIC CDR, but now in use for ILD DBD. Runs very early in the reconstruction, before standard algorithms. Examine ECAL hits in transverse plane, looking for peaks and trying to separate peak clusters from nearby tracks. Likelihood technique used to finalise photon id; photons then removed from subsequent reconstruction. Works very well. Recommend we use this; but must retrain if detector changes. PFA: Photon Id Algorithm