1 © 2015 Eaton. All Rights Reserved.. Suggestion on How to Use Industry Trainers are encouraged to use this material in their sessions Download the presentation.

Slides:



Advertisements
Similar presentations
Control Circuit Protection Supplementary Protectors vs
Advertisements

Lockout/Tagout Awareness Training
Variable Frequency Drives Bypass Options
Denver Fire Alarm Test FUNDAMENTAL, POWER SUPPLIES, CIRCUITS, INSPECTIONS, TESTING and MAINTENANCE.
Initiating Devices Manual Fire Alarm Boxes Ionization Smoke Detectors
Lockout/Tagout Training: 29 CFR Lockout Tagout Standard
State Fire Marshal Question and Answer Session with the Louisiana Automatic Fire Alarm Association March 19, 1999.
LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS
M iniature circuit breakers to UL 489
HYDRAULICS & PNEUMATICS
Ted “Smitty” Smith  I have included in the following slides some key sections from each of the codes you will primarily encounter on the test. I recommend.
©2011, The McGraw-Hill Companies, Inc. Chapter 4.
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
Elevators & Fire Alarm Systems: Understanding Interface Requirements Presented by: Antonio Torres- North Central Regional Sales Manager.
(Adapted from:D.T. Hall:Practical Marine Electrical Knowledge)
Smaller Simpler Better
Switching Device Product Line General Duty and Heavy Duty Safety Switches.
December, 2010 Vmax – Indoor vacuum circuit-breakers for Primary Distribution Product presentation 1VCP – Rev. D, en – Presentation –
Controlling Hazardous Energy
Engineer Training Electrical System Overview and Requirements.
Breaker Basics Welcome to this general overview of ABB.
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE PV APPLICATIONS CODES AND STANDARDS EMERGENCY RESPONSE.
FIRE ALARM SYSTEMS AND FUNDAMENTALS
WELCOME DBI & SFFD Meet the Pros October 11, 2007.
Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code, The National.
Chapter 14: Inspection and Maintenance
Chapter 7 SYSTEM PROTECTION
Section 4: Electric Motors
The First Central Emergency & Standby Lighting System Combining Storage Batteries & Generator Input 1 1.
Electro-Pneumatics Module 1
Welcome Presentation On Office security system. Group Members: Md. Emdadul Haque Md. Sahed Hasan Md. Samsul Arefin Khokan Das.
Industrial Machine Control
Engineer Training XL1200 Electric. Engineer Training XL1200 Electric Confidential 2 Block Diagram.
Lock-Out / Tag-Out Types of Energy Types of Energy Electrical Electrical Mechanical Mechanical Chemical Chemical Thermal Thermal Hydraulic Hydraulic.
Electricity Compressed Air Steam Hydraulic Pressure Gas Lines etc.
Lockout - Tagout Control of Hazardous Energy OSHA Standard
ELCT 201 Spring 2010 Group Projects Electrical Engineering – ELCT 201.
Lockout/Tagout.
© Siemens Industry, Inc All rights reserved. New QR Molded Case Circuit Breaker.
Suggestion on How to Use
1 © 2015 Eaton. All Rights Reserved.. Suggestion on How to Use Industry Trainers are encouraged to use this material in their sessions Download the presentation.
Suggestion on How to Use
Suggestion on How to Use
1 © 2015 Eaton. All Rights Reserved.. Suggestion on How to Use Industry Trainers are encouraged to use this material in their sessions Download the presentation.
Suggestion on How to Use
1 © 2015 Eaton. All Rights Reserved.. Suggestion on How to Use Industry Trainers are encouraged to use this material in their sessions Download the presentation.
1 © 2015 Eaton. All Rights Reserved.. Suggestion on How to Use Industry Trainers are encouraged to use this material in their sessions Download the presentation.
R-Series Rotary Disconnects
Switches and Over Current Protective Devices Class Instructor ALPHER E. DE VERA, uap.
Fluid Power Control.
Fire Protection Systems Chapter 9 IBC 9th Edition Amendments
Chapter 9 Safety Permit Systems
Proposed Changes to the 2009 International Building & Fire Codes
Mersen’s Fused Coordination Panelboard
Fire Alarm Systems for Emergency Operations of Elevators
ELECTRICAL INSTALLATION AND MAINTENANCE (EIM) 5 INSTALL ELECTRICAL PROTECTIVE DEVICES FOR DISTRIBUTION, POWER, LIGHTING, AUXILIARY, LIGHTNING PROTECTION.
Catching up with Code: Updates from
Personal Protective Equipment
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
ELECTRICAL POWER-II Electrical engineering sixth semester
Presented to: IEEE-IAS (Atlanta) Presented by: Michael D. Seal, P.E.
EET 323 – Electrical System Design Lecture 9: Grounding
Control of Hazardous Energy
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
FIRE ALARM DRILL 26 © Ted Smith 2017.
Presentation transcript:

1 © 2015 Eaton. All Rights Reserved.. Suggestion on How to Use Industry Trainers are encouraged to use this material in their sessions Download the presentation file Print the Notes pages and read them as you view the presentation in the “Slide Show” view. In this way you see the slides in large format and have animation (when available)

© 2015 Eaton. All Rights Reserved.. Elevator Codes and Standards

3 © 2015 Eaton. All Rights Reserved.. Applicable Requirements NFPA 13 requires sprinklers in elevator shafts (with some exceptions) and in elevator equipment rooms. ANSI/ASME A17.1 Safety Code for elevators requires that power to an elevator be shut down prior to the release of water in the elevator shaft or electrical equipment room. NFPA 72 The National Fire Alarm Code requires: Control circuits to shut down elevator power shall be monitored for the presence of operating voltage. Loss of voltage to the control circuit for the disconnecting means shall cause a supervisory signal to be indicated at the control unit and required remote annunciation.

4 © 2015 Eaton. All Rights Reserved.. Elevator System Disconnect Options Molded Case Circuit Breakers w/ shunt trip Fusible Switch with Fuses (with contactors for shunt trip) Bussmann Power Module Switch/Panel with Bussmann Low-Peak Fuses

5 © 2015 Eaton. All Rights Reserved.. Elevator System Disconnect Options How is shunt trip actuated? By Fire Alarm System Via Heat Detector or Flow Switch Can these be directly connected?

6 © 2015 Eaton. All Rights Reserved.. Accepted Method Shunt Trip Coil Voltage Supplying Shunt Trip Monitoring Relay Monitoring Relay Contacts Isolation Relay Fire Alarm System Contacts Relay Contacts Shunt Trip Coil

7 © 2015 Eaton. All Rights Reserved.. NEC ® National Electric Code ® Enforced by Electrical Inspector Section Section Section (C)

8 © 2015 Eaton. All Rights Reserved.. NEC ® Section (A) states: (A) Type. The disconnecting means shall be an enclosed externally operable fused motor circuit switch or circuit breaker that is lockable open in accordance with The disconnecting means shall be a listed device. Informational Note: For additional information, see ASME A /CSA B44-10, Safety Code for Elevators and Escalators.

9 © 2015 Eaton. All Rights Reserved.. NEC ® Section (B) states: (B) Operation. No provision shall be made to open or close this disconnecting means from any other part of the premises. If sprinklers are installed in hoistways, machine rooms, control rooms, machinery spaces, or control spaces, the disconnecting means shall be permitted to automatically open the power supply to the affected elevator(s) prior to the application of water. No provision shall be made to automatically close this disconnecting means. Power shall only be restored by manual means. Informational Note: To reduce hazards associated with water on live elevator electrical equipment.

10 © 2015 Eaton. All Rights Reserved.. NEC ® Section (C) states: “Location. The disconnecting means shall be located where it is readily accessible to qualified persons.” “Within Sight of the elevator controller”

11 © 2015 Eaton. All Rights Reserved.. Back-up Power Requirements NFPA 70 The National Electrical Code requires disconnect switches for elevators with backup or auxiliary power (where the backup power is connected on the load side) to be equipped with auxiliary contacts to disconnect the backup power system (C)Disconnecting Means. The disconnecting means required by shall disconnect the elevator from both the emergency or standby power system and the normal power system. Where an additional power source is connected to the load side of the disconnecting means, which allows automatic movement of the car to permit evacuation of passengers, the disconnecting means required in shall be provided with an auxiliary contact that is positively opened mechanically, and the opening shall not be solely dependent on springs. This contact shall cause the additional power source to be disconnected from its load when the disconnecting means is in the open position.

12 © 2015 Eaton. All Rights Reserved.. Battery Lowering S NC Mechanically Interlocked Aux. Contact Elevator Controller Solenoid Elevator Disconnect On(Closed) Position To Piston Drain Valve M Elevator Motor

13 © 2015 Eaton. All Rights Reserved.. Battery Lowering S NC Mechanically Interlocked Aux. Contact Elevator Controller Solenoid Elevator Disconnect Off(Open) Position To Piston Drain Valve M Elevator Motor

14 © 2015 Eaton. All Rights Reserved.. Spring Loaded Contacts Latch Auxiliary Switch Trip Bar Line COM NC NO On(Closed) Position

15 © 2015 Eaton. All Rights Reserved.. Spring Loaded Contacts Latch Auxiliary Switch Trip Bar Line COM NC NO Off(Open) Position

16 © 2015 Eaton. All Rights Reserved.. Fuses Disconnect COM NC NO On(Closed) Position

17 © 2015 Eaton. All Rights Reserved.. Fuses No Mechanical Operation COM NC NO Disconnect

18 © 2015 Eaton. All Rights Reserved.. NEC ® Selective Coordination Requirements Section states: “Selective Coordination. Where more than one driving machine disconnecting means is supplied by a single feeder, the overcurrent protective devices in each disconnecting means shall be selectively coordinated with any other supply side overcurrent protective devices.”

19 © 2015 Eaton. All Rights Reserved.. Elevator 1 Elevator 3Elevator 2 NFPA 70 National Electrical Code "Where more than one driving machine disconnecting means is supplied by a single feeder, the overcurrent protective devices in each disconnecting means shall be selectively coordinated with any other supply side overcurrent protective devices." X NEC ® Selective Coordination Requirements

20 © 2015 Eaton. All Rights Reserved.. Elevator 1 Elevator 3Elevator 2 NFPA 70 National Electrical Code “Selective Coordination shall be selected by a licensed professional engineer or other qualified person engaged primarily in the design, installation, or maintenance of electrical systems. The selection shall be documented and made available to those authorized to design, install, inspect, maintain, and operate the system." X NEC ® Selective Coordination Requirements

21 © 2015 Eaton. All Rights Reserved.. Power Module Switch at-a-glance 600Vac, 3-phase switch Available from 30 to 400A For single elevator applications All-in-one solution for elevator disconnect requirements Shunt trip capability and voltage monitoring UL 98 Listed for 200kA short-circuit current rating Class J fusible branch circuit protection

22 © 2015 Eaton. All Rights Reserved.. Power Module Switch features Auxiliary contacts Mechanically interlocked auxiliary contacts NEMA 1, 3R, 12 or 4 enclosure options Flexibility for different installation environments Triple padlock lockout/tagout Meets requirements for maintenance safety procedures with up to three ¼” padlocks Circuit protection Bussmann Low-Peak Class J fuses Shunt trip system Internally powered, relay activated shunt trip system Easy inspection Optional key-test switch and optional pilot light makes inspection easy

23 © 2015 Eaton. All Rights Reserved.. Power Module Panel at-a-glance 600Vac, 3-phase switch A feeder switches A main switches For multiple elevator applications All-in-one solution for elevator disconnect requirements Shunt trip capability and voltage monitoring UL 98 Listed for 200kA short-circuit current rating

24 © 2015 Eaton. All Rights Reserved.. Power Module Panel features Auxiliary contacts Mechanically interlocked auxiliary contacts Triple padlock lockout/tagout Meets requirements for maintenance safety procedures with up to three ¼” padlocks Circuit protection Bussmann Low-Peak Class J fuses Shunt trip system Internally powered, relay activated shunt trip system Easy inspection Optional key-test switch and optional pilot light make inspections easy

25 © 2015 Eaton. All Rights Reserved.. Summary of Applicable Codes, Listings, & Standards UL 98 Listed enclosed and dead front switches Canadian Standards C22.2, No. 0-M91-CAN/CSA C22.2, No. 4-M89 Enclosed switch Elevator shutdown ANSI/ASME A17.1, Elevator shutdown NEC ® (B) Shunt trip voltage monitoring – NFPA 72, NFPA Selective coordination – NEC ® Auxiliary contact (hydraulic elevator) – NEC ® (C) 25

26 © 2015 Eaton. All Rights Reserved..