Multifunctional LCD Panel HDL-MPL8.48. LCD Panel Description The HDL-MPL8.48 series is a new generation of wall mounted switch, with a total of 8 metal.

Slides:



Advertisements
Similar presentations
Home Automation Products Introduction Home Automation Products تقنية البيوت والمكاتب الذكية –الأجهزة المستخدمة.
Advertisements

TIS Climate Control Course 20 Minutes Test 10 Minutes TIS Training Program 2012, Rev 1.1
Convenience energy saving comfort SMART HOTEL SECURITY.
Linking A quick overview of how to configure PulseWorx UPB devices to control each other.
Technical Tips. Getting Started with emPower™ Learn-in your new Z-Wave-enabled Alarm.com module following the same process as before: – Perform a Module.
Blower Door Quickie Set-Up Guide.
SB-CMS-PIR - ceiling mounted PIR sensor. Subnet ID and Device ID Device Remark Change the ID if needed.
TAKING CARE GUIDELINES Sub-title Place, Month Year.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Wireless Remote Controller (MR-AH01/BH01) HQ SE.  On/Off control  Air flow control  Temperature setting  Filter reset  Louver Control  Simple ON/OFF.
Eclipse EHX System Logic Maestro. Module Objective Introduce Logic Maestro to the user Elements ► What is Logic Maestro ► How does Logic Maestro relate.
Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs SEPAM UMI OPERATION.
DLP LCD PANEL Programming
SMS Module Model : SB-DN-SMS/IP Configuration of SMS Module.
Programming Software and Setting. if forget the IP address of SB-DN-1IP, programmer can press the reset button till the led goes red, then it is reset.
MODEL : EDF-102 SERIES 1. APPLICATION The EDF-102 thermostat is designed to provide temperature control of heating or cooling systems in villas, hotels.
TECHNICAL TRAINING SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB.
Dimmer debugging Big dimmer ( hanging dimmer ) ◆ 12ch 10A professional Intelligent Dimmer ◆ 6ch 20A professional Intelligent Dimmer ◆ 6ch 10A professional.
SB-DN-SEC250K security module SB-DN-SEC250K can manage 8 independent zones’ arming and alarm. Addressing button HDL -BUS.
Fan Coils Units Control
Touch screen function manual Right & left scroll key Room selecting key, Maximal quantity 50. Controlling Target icon Room background image brightness.
HVAC Wiring diagram 5 channel output (5A relay) Speed: High/Medium/Low Mode: Cooling / Heating /Dehumidifier HVAC is a module specially for Air Conditioner.
User Interface – Switch Panel 6 Gang Switch Panel Configuration guide RS485 Terminal Fixing hole Bayonet Front ViewBack View.
DMX Controller SB-DN-512DMX.
Hotel Room Intelligent System applications SMART-HDL.
Service Section Technical Training December 2005.
HDL-MGSM.431. Description MGSM.431 is an automation module based on GSM monitoring and controlling. Being at a great distance you can operate a target.
HDL KNX System Introduction
TOUCH Life SB-WL-TL7 SB-MBL-TS10-CE Windows XP. Touch screen function manual Click the icon 5 times to exit Room select key Room Function Icon function.
Infrared Remote Description Remote control distance : About 5m Two modes: 1. Default control Mode( for all Panel) 2. Page control Mode ( for DLP using,
Programming 27x Optical 10x Digital Zoom Day/Night Camera Prosecutor Day / Night Windshield Mount Camera.
SB-DN-Logic960 Logic programmer / timer. Description  SB-DN-Logic960 is an intelligent programmable logic controller, it can control the system automatically.
目录 12 in 1 Sensor Features ● PIR motion sensor ● Ultrasonic sensor ● LUX sensor ● Temperature sensor ● 2 Dry contacts ● 2 external condition inputs ● IR(infrared)
Programming Software and Setting. Default IP Add : , also can be changed via Programming Software, if forget IP address, Programmer can.
MRDA Wiring diagram S-BUS Module ID setting button ballast L N DC0-10V dimming voltage Control DC Maximum current :100mA 6 relay switch 16A 6 channel.
Hardware, 010 – Revision notes Scales use Controller board O/Ps for Feed Control (FCE’s) Flow meters use their own on board O/Ps for Feed Control (FCE’s)
Solutions for Hotel HDL-MHRCU.431.
目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.
Curtain Controller SB-DN-2Motor. SB-DN-2Motot is a professional two curtains(shutters) controller. The curtain module can control the curtain by AC motor.
目录 SB-CMS-8in1 Features ● 1 PIR motion sensor ● 1 Lux sensor ● 2 Dry contact inputs ● 2 external condition inputs ● IR(infrared) receiver ● IR(infrared)
1 i-Pendant for the R-J3iC & R-30iA Controllers ArcTool Version (GMAW) i Pendant New.
The New Switch can replace all the Old Room Needed Controllers 1– Light Switches and Wall Dimmers 2– Air-conditioning Thermostat 3– Volume Control 4–
How to configure alarm system
Start up: 1. Power off and insert a GSM card, power on and check the GSM signal on the LCD. 2. Use the LCD and keys on the module to check and set the.
System Important Points for Wiring
Air-Condition controller
DIN Rail Music Player HDL-MZDN.432A.
DALI Scene Controller HDL-MC-DALI.431.
DIN Rail Music Player HDL-MZDN.432A.
Multifunctional Sensor
SMS module HDL-MGSM.431.
FLoor Heating Controller
Power meter SB-DN-PM1P03 SB-DN-PM3P02.
Dimmer 6fold 10V Actuator M/DA
Security module SB-DN-SEC250K.
Wireless Relay HDL-MPR01-RF.18.
Dry contact sensor HDL-MSD04.40 HDL-MSD08.40.
DMX Controller SB-DN-48DMX.
FLoor Heating Controller
Wireless 4 Buttons Touch Panel
IR Emitter module SB-IR-EM.
DMX512 Gateway M/DMX512.1.
Wireless 3 Buttons Touch Panel
MOSFET Dimmer Actuator
Wireless Relay HDL-MPR02-RF.18.
Curtain Actuator M/W
Hotel Room Intelligent System
Dry contact sensor HDL-MSD04.40 HDL-MSD08.40.
Curtain Motor HDL-MWM70B.12 HDL-MVSM45B.12.
Maxsony Technology Limited
Presentation transcript:

Multifunctional LCD Panel HDL-MPL8.48

LCD Panel Description The HDL-MPL8.48 series is a new generation of wall mounted switch, with a total of 8 metal buttons each with a configurable LED. Both the plate and frame can be customized with different materials and colors to perfectly match your lifestyle.

Functions 1.Adjustable LCD Backlight and LED Indicators. 2.Multiple pages- four normal button pages, one specified page for Floor Heating, HVAC, and Music control is available. 3.Each of the keys can have a user designed icon 4.Single button mode and double button mode are available. 5.The mutual exclusion of buttons is available. 6.The following functions are included: IR Receiver, Lock, Turn on/off AC, Cooling & heating for AC. Auto temperature setting, Fan Speed regulation, AC Mode setting, AC Temperature regulation, backlight adjustment, AC Lock, Backlight and status light setting, floor heating temperature and mode setting etc.

Basic Information Device's Subnet ID and Device ID Set the LCD brightness Set the LED brightness

Key no. Key remark Key mode Control targets Page no. Target totality Key Assignation

Key remarks save Key Remark

Key modes save Key Mode

Frequently used key modes: Single On: send out one ON command when pressed. Single Off: send out one OFF command when pressed. Single On/Off: send out one ON/OFF (toggle) command when pressed. Momentary: send out one ON command when pressed down, send out one OFF command when released. Combination ON: can send out up to 99 ON commands when pressed. Combination OFF: can send out up to 99 OFF commands when pressed Combination ON/OFF: can send out up to 99 ON/OFF (toggle) commands when pressed. Key Mode

Setup targets for each key save Targets

Frequently used command types: Invalid: disable the command. Scene Switch: Used to recall the scene that you have created in the dimmer or relay. Sequence Switch: Used To recall the sequence that you have created in the dimmer or relay. Universal Switch: Used to send infrared code number, set logic flag On or Off, set the hotel door bell services, disable or enable Motion sensor, … Single channel lighting control: Used to turn on/off one channel (with brightness level & running time in the command) Curtain Switch: Used to open, close or stop the curtain. Broadcast scene: Used to recall some certain scenes (same scene no.) of all Areas of a dimmer or relay module. Broadcast Channel: Used to turn on/off all channels of a relay module or set all channels of a dimmer to the same level. Command Type

Default type: (1). Take (3) as an example, key 1 and 2 are bonded, key 3 and 4 are bonded. Key Combination

Double click it to select a pic with bmp format from your PC. upload pictures Picture Upload

Adjust the temperature if there is error. Right click to refresh and read the status, or adjust the setting and save it to the DLP. DLP can share (to specific device or broadcast) its temperature source. HVAC ID AC Control: DLP + HVAC

Check this option Send “universal switch” to SB-IR- EM to control AC. Tips: the parameter 1 is the index no. in SB-IR-EM. AC Control: DLP + IR Emitter

Set fan speed and mode AC Fan & Mode

Set temperature range Temperature Range

Set temperature source Temperature Source

For floor heating and z-audio configuration, please refer to floor heating module and Z-Audio module. Floor Heating & Music