Comparative Study of the Aspheric Akreos Adapt AO IOL Versus the Spherical Akreos Adapt IOL Maghizh Anandan Martin Leyland.

Slides:



Advertisements
Similar presentations
Spherical Aberration Post Bilateral Implantation of Two Prevalent Aspheric IOLs DR. ROBERT A. KAUFER, MD MARTINEZ, BUENOS AIRES ARGENTINA
Advertisements

VisTor The new Toric IOL by Hanita Lenses
Dr H. Razmjoo Isfahan University of Medical Sciences Multifocal IOLs
Comparison of Visual Outcomes With Toric IOL and With Limbal Relaxing Incisions in Cataract Surgery Eriko Fukuyama, MD Fukuyama Eye Clinic Fukuoka, Japan.
Diffractive Multifocal IOL Prof. Dr. Daniel H. Scorsetti
R. Lehmann, MD ASCRS 2008 Clinically Relevant Advantages in the Functional Performance of the AcrySof ® IQ IOL Robert P. Lehmann, MD, FACS Lehmann Eye.
Keiichiro Minami, Hiroko Bissen-Miyajima, Mami Yoshino, Kunihiko Nakamura Department of Ophthalmology Tokyo Dental College Suidobashi Hospital, Tokyo,
The new Akreos MI 60 lens Joel Pynson, MD - Director Design Engineering Bausch & Lomb, Toulouse - France London, September 9th 2006.
Visual outcome & subjective visual symptoms of the Tecnis ZM900 multifocal intraocular lens in Asian eyes Dr Colin S.H. Tan MBBS, MMed (Ophth), FRCSEd.
Multifocal Intraocular Lenses & Contrast Sensitivity
Aspheric IOL’s: clinical benefits and customizing cataract surgery Bojan Pajic, MD, PhD, FEBO Swiss Eye Research Foundation, ORASIS, Reinach, Switzerland.
Ocular Aberrations and Quality of Vision with Aspheric Single-Piece and Spherical Multi- Piece IOL: Contra lateral Comparative Study Ahmed Assaf MD, FRCSEd.
Astigmatism Following 2 IOL Injection Techniques: Wound Assisted Versus Wound Directed Jay J. Meyer, MD Hart B. Moss, MD Kenneth L. Cohen, MD University.
A Prospective, Randomized, Comparative Evaluation of Patients with Contralateral Implantation of Two Aspheric Acrylic Intraocular Lenses R. Cionni, MD.
Cataract Surgery Using Biaspheric IOLs in Patients With Corneal Irregularities James P. Gills, MD St. Luke’s Cataract & Laser Institute Tarpon Springs.
Eltutar, Kadir; Akcetin, Tulay A.; Ozcelik, N. Demet Istanbul Education and Research Hospital Department of Ophthalmology The authors state that they have.
Ruth Lapid-Gortzak MD PhD 1,2, Jan Willem van der Linden BOpt 2, and Ivanka J. van der Meulen MD 1,2 1 Department of Ophthalmology, Academic Medical Center,
Retrospective Comparison of 3177 Eyes Implanted with Presbyopic IOLs Carlos Buznego MD Elizabeth A. Davis MD, FACS Guy M. Kezirian MD, FACS William B.
REFRACTIVE ASPECTS OF CATARACT SURGERY. OPTICAL CORRECTIONS AFTER CATARACT EXTRACTION.
Placement of Toric Intraocular Lens and the Long-term Change in the Axis of Corneal Astigmatism after Sutureless Cataract Extraction by Phacoemulsification.
Somasheila I. Murthy, Prashant Garg, Pravin K. Vaddavalli
Bret Fisher, MD The Eye Center of North Florida Panama City, FL
Medical Director - R & D Consultant, Ziemer Group AG, Port, Switzerland Speaker, Bausch & Lomb do Brasil Territory Manager.
Phacoemulsification in eyes with previous anterior chamber phakic IOL surgery Walton Nosé, MD, PhD 1,2 Adriana dos Santos Forseto, MD 1 Mariana Ávila,
Change in Patient-Reported Outcomes and Visual Acuity After Bilateral Implantation of Apodized Diffractive +3.0 IOLs Stephen Lane, MD Consultant, Alcon.
Unilateral multifocal lens implantation in patients with a contralateral monofocal or phakic eye is a viable presbyopic correction option Robert J. Cionni,
Neeti Parikh, MD Fuxiang Zhang, MD Department of Ophthalmology Henry Ford Hospital A Comparison Of Patient Satisfaction With Modified Monovision Versus.
W. Andrew Maxwell, MD, PhD Rob Gray, PhD Disclosures: This study was funded by Alcon Research, Ltd, which also assisted with the preparation of these slides.
Biometric Accuracy in High Hypermetropes and Myopes
A Fellow Eye Comparison of Aberrations, Modulation Transfer Function and Contrast Sensitivity After AcrySof IQ and AcrySof Natural IOL Implantation. Mayank.
Clinical and simulation outcomes of a multifocal intraocular lens with rotational asymmetry and two different levels of near addition Jorge Alió, MD,PhD.
P91: Clinical Performance of Phakic Angle-Supported Investigational IOL in Prospective Global Trials, ASCRS 2010, Boston P91: Clinical performance of phakic.
Evaluation of refractive error measurements obtained by three different aberrometers Radha Ram, BA Li Wang, MD, PhD Mitchell P. Weikert, MD, MS Disclosure:
Effect of Aspherical Intraocular Lens on Blue-on-Yellow Perimetry  No eye had intraoperative complications. At 12 months after surgery, all the lenses.
Kaori Morii, M.D. Shinji Miura, M.D, Ph.D. Dept. of Ophthalmology, Asagiri Hospital, Hyogo, JPN We have no financial interest. This retrospective study.
A case of hypermature cataract formation following implantation of a posterior chamber phakic intraocular lens with a central hole The Catholic University.
Endothelial Keratoplasty in Patients With an Anterior Chamber Intraocular Lens: A Montreal Experience Georges M. Durr, MD 1,2 Johanna Choremis, MD, FRCSC.
OHM Effect of low-to-moderate degrees of refractive astigmatism on Contrast sensitivity and Reading speed in pseudophakic eyes Shetal M. Raj, DO, MS, Abhay.
Multifocal Intraocular Lenses Abdullah Al-assiri Mansour Farooqui Abdulrahman Al-Muammar Saudi Ophthalmology Meeting 2009.
AcrySof ® ReSTOR ® Aspheric IOL. Aspheric IOL AcrySof ® ReSTOR ® 2 AcrySof ® ReSTOR ® Aspheric IOL SN6AD3 Add Power: +4 D Spectacle Plane: 3.2 D Range:
Controversies about binocular function and patient satisfaction after induced conventional monovision in case of bilateral intraocular lens implantation.
10 year follow up of LASIK surgery for low to high levels of myopia Qasim Qasem FRCS, Caitriona Kirwan MRCOpth, Michael O’Keefe FRCS. Institutional Affiliations:
Futoshi Taketani, MD,PhD,
Visual and IOP Outcomes after PRK in Pigment Dispersion Syndrome [Poster Number: P190] Kraig S. Bower, Denise A. Sediq, Charles D. Coe, Keith Wroblewski,
LogMAR-Analysis of multifocal intraocular lenses: Clinical performance A. Mannsfeld, I.-J. Limberger, A. Ehmer, M.P. Holzer, G. U.Auffarth International.
AcrySof ® ReSTOR ® Apodized Diffractive IOL. What is the AcrySof ® ReSTOR ® IOL? The AcrySof ® ReSTOR ® IOL incorporates an apodized diffractive optic.
Financial Disclosure: Medical Director–Galilei R&D Consultant, Ziemer Group AG, Port, Switzerland Consultant & Territory Manager for.
Comparison of visual function following piggyback implantation of Acrysof ReSTOR intraocular lenses with Tecnis multifocal ZM900 intraocular lenses. Rodrigo.
Comparison of 2 Models of Aspheric Diffractive Multifocal IOL
Investigation of Multifocal Toric IOLs to Compensate for Corneal Astigmatism and to Provide Near, Intermediate, and Distance Vision José L. Rincón, MD.
Preliminary Results after Cataract Surgery with the Aspheric Acrysof ReSTOR IOL to Correct Presbyopia Meeting of the ASCRS Chicago 8-10 February 2007 R.M.M.A.
Comparing Factors Affecting Surgically Induced Astigmatism
Inadvertent Insertion of an Opposite- Side Tecnis ZM900 Multifocal IOL Wilson Takashi Hida, M.D. Celso Takashi Nakano; Jonathan Lake;
Minimizing Risk in Visian ICL Implantation.
Toric IOLs: wavefront aberrometry and quality of life Mencucci Rita Giordano Cristina, Stiko Ermelinda, Miranda Paolo, Eleonora Favuzza, Ugo Menchini Authors.
F.I. Camesasca, MD Zeiss Invent ZO Aspheric IOL: Long-Term Results of Refractive and Aberrometric Analysis F. I. Camesasca* P. Vinciguerra.
Global Meta-Analysis on Visual and Optical Quality Comparison for Aspheric vs Spherical IOL Technology James P. McCulley, MD Department of Ophthalmology.
Dissatisfication After Multifocal Intraocular Lens Implantation in Taiwan Yu Wei Lin, MD (Presenting Author); Ching-Ju Hsieh; Lin-Chung Woung The authors.
Liquifaction Method and Extent of Posterior Capsule Opacification: Two-Year Follow-up Marie Kalfertova, Mariya Burova, Pavel Rozsival, Nada Jiraskova Nada.
Vinohrady Teaching Hospital, Prague, Czech Republic Vinohrady Teaching Hospital, Prague, Czech Republic M. Vokrojova MD, M. Vokrojova MD, D. Sivekova MD,
Postoperative Refraction and Patient Satisfaction after Bilateral Implantation of Presbyopia-Correcting Intraocular Lenses Robert Cionni, MD Financial.
Charlotte ROHART1, Gilles Chaine1, Damien GATINEL2
Effect of Axial Length Measurement Method on Refractive Outcomes of Cataract Surgery: Real World Comparison of Partial Coherence Interferometry and Immersion.
Eye clinic of the 3rd Faculty of Medicine, Prague, Czech Republic
MI60 INTRAOCULAR LENSES – OUR EXPERIENCE
Thomas Kohnen, MD Department of Ophthalmology
Comparison of vision with an accommodating IOL versus a multifocal IOL
David T. Vroman, MD Assistant Professor of Ophthalmology
Visual Outcomes and Satisfaction with Toric IOL Versus Monofocal IOL
Comparative Global Literature Review of Visual and Optical Quality of Refractive, Diffractive, and Hybrid IOL Designs James P. McCulley, MD Department.
Presentation transcript:

Comparative Study of the Aspheric Akreos Adapt AO IOL Versus the Spherical Akreos Adapt IOL Maghizh Anandan Martin Leyland

Purpose Standard IOL’s provide good visual acuity but they often increase spherical aberration and reduce contrast sensitivity. This study compares the optical performance of the aberration free Akreos Advanced Optic IOL (AO) with the conventional spherical Akreos Adapt IOL (AA).

Methods Twenty five patients requiring bilateral cataract surgery were enrolled in to this prospective, intra-individual comparative study. One eye received the AO lens and the other eye the AA control lens according to the randomisation table. Study was double masked. Neither the patients nor the examiner at the post-op visit knew which eye had the aspherical IOL. Quality of vision was tested by visual acuity, contrast sensitivity and ‘quality of vision’ questionnaire All patients were operated on by the same surgeon (M.L) using the same technique and were followed up for at least 3 months Written informed consent was obtained from all patients before surgery, and the study was approved by the local ethics committee. Preoperative and postoperative evaluations included uncorrected distance visual acuity, (BSCVA), spherical equivalent (SE), slitlamp biomicroscopy, applanation tonometry, fundus examination, B-scan biometry Clinical data were collected preoperatively and 1 and 3 months postoperatively. –Unaided and best spectacle-corrected visual acuity, contrast sensitivty

Contrast sensitivity Contrast sensitivity was measured using SIFIMAV test screen, containing sinusoidal gratings of 5 spatial frequencies with 8 contrast sensitivity levels each. The examinations were performed unilaterally at a distance of 2.5 m with BSCVA and an un-dilated pupil. All measurements were performed under the same conditions by an examiner who was unaware of the type of IOL implanted. Questionnaire All patients were given a questionnaire at the last follow-up The questionnaire was designed to determine whether a patient was experiencing any form of dysphotopsia in any of the eye (Light-caused glare, Increase in eye sensitivity, Unwanted images) If the patients said yes to the above in any/both eye they will answer further questions to determine the nature and level of dysphotopsia by points system. Light related glare was scored as 0 if none, 1 for minimal, 2 for annoying and 3 for debilitating. –This questionnaire was been developed by Tester and co authors (Dysphotopsia in phakic and pseudophakic patients : incidence and relation to intraocular lens type.J. Cataract Refract Surg 2000; 26: )

Analysis For statistical analysis of visual acuity, logarithm of minimum angle of resolution (logMAR) acuity values were used. Similarly, the recorded contrast sensitivity values were transformed into log values. The 2 IOLs were compared between eyes intra-individually. P value less than 0.05 was considered statistically significant. Results 46 eyes of 23 patients were included in the study 2 patients died after bilateral surgery but before assessment were completed and hence excluded from study 7 patients(30%) were men, and 16 (70 %) were women The mean age was 77 years (range 68 to 90 years). All patients completed the 3-month follow-up. There were no intra-operative complications 16 eyes underwent limbal relaxing incisions (7 in AO group and 9 in AA group)

Contrast sensitivity AA IOLAO IOLP value 1.5 cpd cpd cpd cpd cpd There was no statistical differences in any of the spatial frequencies Visual acuity Pre-operative Mean logMAR BSCVA was 0.49 AA and 0.45 AO (P = 0.67) Post-operative (3 months) Mean logMAR unaided VA was 0.20 AA and 0.24 AO (P = 0.60) Mean logMAR BSCVA was 0.06 AA and 0.07 AO (P = 0.57) Mean sperical equivalent refraction AA and AO (P = 0.60)

Questionnaire - Analysis No statistical difference in light-related glare score in either of the IOL Both lens performs well and patients were generally very satisfied Two out of 11 patients who drive found it difficult to drive at night due to glare ( One in each IOL type). AO IOLAA IOL Glare scoring Glare %42.1% Sensitivity %36.8% Unwanted images %31.5%21%

Conclusion No statistically significant differences were found between aspherical and spherical IOLs in postoperative VA and refraction. Contrast sensitivity was performed with an un-dilated pupil and best spectacle correction in normal room light condition to create a more real life situation. There were no statistical differences at any of the spatial frequencies. The questionnaire analysis showed that the patients in our study were very satisfied with the quality of vision with both IOLs, with a low incidence of adverse visual phenomena.

Discussion Standard intraocular lenses have a positive spherical aberration (SA) that, when added to the positive SA in the normal cornea, increases ocular SA. Aspherical IOLs have been designed to compensate for the positive SA of the cornea Advanced Optics (AO) aberration-free aspheric intraocular lens is a Hydrophilic acrylic lens with a 360-degree square edge. Both the anterior and posterior surfaces are aspheric and are designed so that the lens itself has no spherical aberration. Theoretical advantages of this IOL –Does not contribute to any pre-existing higher-order aberrations as its surface is aspherical –If the IOL is decentered it does not induce other aberrations, such as coma or astigmatism There are other lenses on the market with negative spherical aberration, which are designed to offset the average corneal spherical aberration. One has to remember when using such lenses, that in some cases of highly prolate corneas, the patient will have an end result of considerable negative spherical aberration rather than a neutral offset.

Discussion We made a significant effort to reduce the bias that can occur in comparative clinical studies by making our study an intra-individual comparison, using the same IOL material manufactured by the same company, and having the same surgeon perform bilateral surgery using an identical surgical technique. Many studies have shown better contrast sensitivity measurements with aspherical IOL especially in mesopic conditions. We performed the contrast sensitivity with an un-dilated pupil and best spectacle correction only in normal room light condition. This may be the reason why we did not show any statistical difference in contrast sensitivity but when asked which eye the patient preferred in terms of overall vision, only 33.3% were AO IOL’s. Therefore, it remains questionable whether any significant differences in contrast sensitivity have clinical relevance and what it means for the patient. In a recent large multicenter study Akreos Adapt Advanced Optics (SA 0.00 μm, Bausch & Lomb Inc) and Tecnis Z9000 (SA −0.27 μm, Advanced Medical Optics, Inc.), were compared. The differences in eye preference and visual disturbance between the 2 IOLs favored the Akreos AO. This was interesting considering the results of the wave-front analysis, in which the total higher order aberration, in particular the spherical aberration, was significantly lower in eyes with the Tecnis Z 9000 IOL. They concluded that maximum reduction of spherical aberration does not correlate with the perceived visual quality of the eye having surgery.

Discussion Limitations of our study are that, we could not perform wave front analysis on all patients and hence not included in the analysis. However this would have been only theoretical as several studies have shown that better final spherical aberration does not correspond to better vision. Contrast sensitivity was not performed in mesopic conditions for comparison but we included specific questions about night vision including driving at night, in the questionnaire to ascertain the quality of vision and contrast in mesopic conditions and found no statistical differences. Another limitation is that this study assumed that the IOLs were well centered and not tilted; decentration of IOLs induces coma, which may affect the final outcome in that eye.

Discussion The design of this study, with bilateral surgery and randomized implantation of the 2 IOLs, was chosen to minimize the effects of factors other than the IOLs such as ocular dominance or refraction deviations, which could affect the outcomes. The double-masking also likely minimized bias, particularly in the results of the patient questionnaires. Despite this, we found no differences between the IOLs in low-contrast visual acuity or contrast sensitivity. The patients' awareness of having different IOLs in the right eye and left eye may have increased their awareness of minor differences between the eyes. Still, about half the patients reported no difference between the eyes, which is probably because of the patients' high level of overall satisfaction with the surgical results, visual improvement, and IOL performance. In summary, the Akreos AO IOL and Akreos IOL gave similar contrast visual acuities as well as photopic contrast sensitivities. Refrences: L. Wang et al, Optical aberrations of the human anterior cornea, J Cataract Refract Surg 29 (2003), pp. 1514–1521. Visual and optical performance of the Akreos Adapt Advanced Optics and Tecnis Z9000 intraocular lenses Swedish multicenter study, Journal of Cataract & Refractive Surgery, Volume 33, Issue 9, September 2007, Pages Custom optimization of intraocular lens asphericity Journal of Cataract & Refractive Surgery, Volume 33, Issue 10, October 2007, Pages Optical performance of 3 intraocular lens designs in the presence of decentration, J Cataract Refract Surg 31 (2005), pp. 574–585. Effect of decentration of wavefront-corrected intraocular lenses on the higher-order aberrations of the eye, Arch Ophthalmol 123 (2005), pp. 1226–1230. Ocular aberrations and contrast sensitivity after cataract surgery with AcrySof IQ intraocular lens implantation Clinical comparative study.J Cataract Refract Surg Nov;33(11):