Fumihiko Ukegawa University of Tsukuba, Japan 6th Joint Korea-Japan ScEcal Meeting September 3, 2010 Kobe University Photo-sensor studies.

Slides:



Advertisements
Similar presentations
MPPC readout electoronics
Advertisements

Data analysis BTF 23 e 24 mag 05 T1 T2 500MeV electrons Repetition Rate 50 Hz Pulse Duration 1-10 ns Current/pulse 1 to 8 particles σ XY ~2mm Max Electronic.
New test result of MPPC M.Taguchi(kyoto).
Comparison of 3 types of scintillator strips and 2 types of reflector films Miho NISHIYAMA Shinshu-U Light yield of 3 scintillator strips have been measured.
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan 1.Introduction 2.Recent.
Study of the MPPC Performance - contents - Introduction Fundamental properties microscopic laser scan –check variation within a sensor Summary and plans.
Kuno-Group B4 Yuuki Matsumoto A report for Graduation research Development of Trigger Board for MPPC (for MuSIC experiment) A report for Graduation research.
Performance of MPPC using laser system Photon sensor KEK Niigata university, ILC calorimeter group Sayaka IBA, Hiroaki ONO, Paul.
Study of Photon Sensors using the Laser System 05/7/12 Niigata University, Japan Sayaka Iba, Editha P. Jacosalem, Hiroaki Ono, Noriko.
Veto Wall Test Hyupwoo Lee MINERvA/Jupiter Group Meeting Feb, 13, 2008.
1 A proposal of new simple system for testing a large number of MPPC for the R&D phase of GLD calorimeter 2007/Feb/6 ACFA ILC Workshop ICEPP, University.
Calibration of the 10inch PMT for IceCube Experiment 03UM1106 Kazuhiro Fujimoto A thesis submitted in partial fulfillment of the requirements of the degree.
Veto Wall Test Hyupwoo Lee MINERvA/Jupiter Group Meeting Apr, 16, 2008.
MPPC R&D status Kobe Univ. CALICE collaboration meeting Yuji SUDO Univ. of Tsukuba ~ contents ~ Introduction Linearity curve Recovery time.
Selection of Silicon Photomultipliers for ILC Analogue Hadron Calorimeter Prototype Lay-out * ILC Hadron Calorimeter prototype with SiPM readout * Selection.
Tests with JT0623 & JT0947 at Indiana University Nagoya PMT database test results for JT0623 at 3220V: This tube has somewhat higher than usual gain. 5×10.
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK) for KEKDTP photon sensor group.
ArgonneBeamTest_ ppt1 Argonne Beam Test preparation Tsunefumi Mizuno Tuneyoshi Kamae
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
The Scintillator ECAL Beam Test at FNAL Adil Khan International Linear Collider Workshop 2010 LCWS10 & ILC10, Beijing, China CALICE Scintillator ECAL group.
The Scintillator ECAL Beam Test at FNAL K. Kotera, Shinshu-u, 1st October 2009 CALICE Scintillator ECAL group; Kobe University, Kyungpook University, the.
MPPC update including plastic connector T2K experiment collaboration meeting 2007/4/18 (Wed) S.Gomi T.Nakaya M.Yokoyama ( Kyoto University ) T.Nakadaira.
R&D of MPPC for T2K experiment PD07 : Photosensor Workshop /6/28 (Thu) S.Gomi T.Nakaya M.Yokoyama H.Kawamuko ( Kyoto University ) T.Nakadaira.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
Study of the MPPC performance - R&D status for the GLD calorimeter readout – Nov 6-10.
MEG II 実験 液体キセノンガンマ線検出器に用いる 光検出器 MPPC の 実装に向けた最終試験 家城 佳 他 MEG II collaboration + 九大の方々.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK)
Study of the MPPC for the GLD Calorimeter readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group May 29 – Jun 4 DESY Introduction.
1 Development of Multi-Pixel Photon Counters (1) S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira, K.Yoshimura, (KEK) Oct
1 MPPC update S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira (KEK) Nov KEK.
11 Saturation of MPPC detector Detector meeting 2010/11/18 M2 Hiroko Koike _ikuno.ppt.
MPPC status M.Taguchi(kyoto) T2K ND /7/7.
Development of Multi-Pixel Photon Counters(MPPC) Makoto Taguchi Kyoto University.
MPPC Saturation Corection Idea -> how to do. MPPC Gain measurement To apply saturation correction to the beam data, all MPPC are needed to be calibrated.
Trip-t testing progress report
Performance of SiPM Ryuhei Nakamura (Kobe Univ.) GLC calorimeter group (KEK, Kobe, Konan, Niigata, Shinshu, Tsukuba) Contents ・ Introduction ・ Test results.
SCECAL progress report Tohru Takeshita (Shinshu) _DESY Beam Test summary _improvements for FNAL BT _FNAL module _current status at Fermilab.
Status of photon sensor study at Niigata University -- SiPM and MPPC -- Photon sensor mini workshop 05/9/16 University Niigata University.
Development of Multi-Pixel Photon Counters and readout electronics Makoto Taguchi High Energy Group.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group (KNU, Kobe, Niigata, Shinshu, ICEPP.
Timing Studies of Hamamatsu MPPCs and MEPhI SiPM Samples Bob Wagner, Gary Drake, Patrick DeLurgio Argonne National Laboratory Qingguo Xie Department of.
Linearity Tests The laser induced high noise pulses on the APD rendering it useless. We tried several methods to shield and filter the noise. With a stabilized.
1 Calorimeters LED control LHCb CALO meeting Anatoli Konoplyannikov /ITEP/ Status of the calorimeters LV power supply and ECS control Status of.
DESY BT analysis - MPPC Saturation Correction - S. Uozumi Feb Sci-ECAL meeting 1.MPPC Gain Measurement (with LED data) 2.Inter-calibration of readout.
MPPC mass check Hidetoshi OTONO. Change point ADC Gate width : 6ns => 35ns Gain mesurement without LED.
Performance of new MPPC Nov. 21 Korea-Japan joint meeting Takashi Maeda Hideki Yamazaki Yuji Sudo (University of Tsukuba) --- Contents ---
FEE card validation M. Raggi, T. Spadaro. The problem Validate FEE production – threshold determination at < 1mV accuracy – comparator time effects: Overdrive.
Beta-ray test for strip scintillator readout MPPC GLD Cal group KEK 06/2/28 (Tue) Niigata university Sayaka IBA.
ILC meeting 5/14 A large amount of measurement concerning fundamental property of MPPC 光検出器 MPPC の 基礎特性に関する大量測定 University of tsukuba M2 Hiroko koike 1.
Comparison of 3 types of scintillator strips Miho NISHIYAMA Shinshu-U Light yield of 3 scintillator strips have been measured using b-ray source. 1. fiber.
MPPC mass check Jan9/2007 Hidetoshi OTONO. Our plan for mass check with relays MPPC relayOn MPPC relayOFF MPPC relayOFF DC board AMPADC relayOFF 測定対象.
CDH time resolution M.Tokuda. 目的: CDH の基本性能である時間分解能を調べる ・まず TDC-calibration を行った。 次の回路によりチャンネルあたりの時間 ([s]/[ch]) を 測定した。 Pulse generatordelayTDC(100ns.
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan for the GLD Calorimeter.
Study and Development of the Multi-Pixel Photon Counter for the GLD Calorimeter Satoru Uozumi (Shinshu, Japan) on behalf of the GLD Calorimeter Group Oct-9.
ILC-CAL Test status of HPK photon sensors Kobe-U Y.Tamura / K.Kawagoe Confidential: do not distribute outside.
PMT AFTERPULSE STUDIES By Ugur Akgun The University of Iowa.
Silicon Photomultiplier Development at GRAPES-3 K.C.Ravindran T.I.F.R, OOTY WAPP 2010 Worshop On behalf of GRAPES-3 Collaboration.
1 Development of a Large Area Photodetector with a Fast Phosphor Anode Toru Iijima Kobayashi-Maskawa Institute Nagoya University Open Meeting for the Hyper-Kamiokande.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK) for KEKDTP photon sensor group.
M.Taguchi and T.Nobuhara(Kyoto) HPK MPPC(Multi Pixel Photon Counter) status T2K280m meeting.
S-2S meeting Toshiyuki Gogami 15 Oct Contents TOF detector Kyoto University.
Performance of 1600-pixel MPPC for the GLD Calorimeter Readout Jan. 30(Tue.) Korea-Japan Joint Shinshu Univ. Takashi Maeda ( Univ. of Tsukuba)
1 MPPC Timing Resolution Akito Kobayashi Shinshu University Table of contents ・ Timing Resolution ・ Set up ・ data treatment ・ result(1) ・ result(2) ・ result(3)
Development of Multi-Pixel Photon Counters (1)
ScECAL+AHCAL+TCMT Combined Beam FNAL
Instrumentation for Colliding Beam Physics 2017
R&D of MPPC for T2K experiment
The MPPC Study for the GLD Calorimeter Readout
Presentation transcript:

Fumihiko Ukegawa University of Tsukuba, Japan 6th Joint Korea-Japan ScEcal Meeting September 3, 2010 Kobe University Photo-sensor studies

MPPC and its linearity It saturates, by definition, at N fired = N totoal pixels

MPPC and its linearity : naively thinking It saturates, by definition, at N fired = N total pixels Output Input In reality, things are more complicated !!

Reality : FNAL test beam data Output extends way beyond N total N total pixels = 1600 LED irradiation 1600

On the test bench, as well Again, output exceeds N total N total pixels = 1600 Irradiate scintillator with laser 1600

Extended linear response because of : LED and Scint+WLS are not particularly fast, of order ns MPPC pixels have a quick recovery time - A fired pixel won’t remain dead for long. It can fire again after, say, 4 ns. If the next photon comes after that, it can again give an output, and contribute to Q out So it depends on the time structure of incident photons What you think is happening : Pixels fire multiple times within the duration of a given pulse, and contribute to the extended linearity

If you put in a very short pulse, it should saturate at N tot Output Input Use a fast light source and measure it !

Hamamatsu pico-second pulser and laser : PLP-10 Catalog spec: ~70 ps pulse width, << 4 ns recovery time Detect the same light with PMT, use as a reference for the amount of light injected.

Need to scan a wide range in the amount of light Insert a polarizing plate between the laser and MPPC/PMT Laser light is polarized (at least partially) Rotating the plate can control the amount of light transmitted Semi-automatic, scans relatively quickly In steps of 4.5 degrees

Setup Clock Generator NIM Fixed DELAY Laser Source CAMAC RELAY NIM Fixed DELAY Gate Generator Thermostatic chamber( 常温 ) Polarized Controller Gate Analog CAMAC ADC H.V Power Supply 700V Voltage Power Supply Over 3V MPPC out in 200ns polarizing plate PC RS232C PCI Discriminator

Setup 11 PMT MPPC Filter Laser Polarizer

Scope photos 12 PMT MPPC GATE

Rotating the polarizer : Controlling the amount of light 13 PMTMPPC Rotation steps (4.5 degrees) Pulse heights (ADC counts) as a function of the angle Sinusoidal behavior for PMT

Converting to the number of pixels fired 77.2 V

MPPC vs. PMT (example) PMT Pulse Height (ADC counts) Seems to be saturating where it should be ! 1626

Repeat 30 times : same piece PMT Pulse Height (ADC counts) Reproducibility reasonably good

Same single piece, but remove from the socket and re-insert, 10 times Even better(?) reproducibility PMT Pulse Height (ADC counts)

Try different pieces : total of 10 PMT Pulse Height (ADC counts) p0 are the same, but p1 seem to vary from a piece to another

Red : single sample, just repeated 30 times Pink : single sample, removed and re-inserted, 10 times Blue : 10 different samples

Summary

To do :

Backup

PMT linearity : HV curve PMT HV ( V ) PMT pulse height (ADC counts) [0]*pow(x,[1]) 図より700 V に設定しまし た。 ( fit 範囲の真ん中で妥当な 値)

d Pedestal 1p.e. 2p.e. 3p.e. 4p.e. Gain measurements Clock Generator Gate Generator Voltage source Voltage source LED driver ADC Gate Analog In Delay AMP×63 Thermostatic chamber LED MPPC PC CAMAC Width 55ns 1kHz Setup Pulse height distribution Light source : LED (green)

Single piece, 30 times 0.7% RMS / Mean Measurements

26 4.3% RMS / Mean Measurements Single piece, 30 times

27 Single piece, re-inserted 10 times Measurements 0.7% RMS / Mean

28 Measurements 4.4% RMS / Mean Single piece, re-inserted 10 times

29 10 different pieces Measurements 0.7% RMS / Mean

30 Measurements 12% RMS / Mean  Piece-to-piece variation. Of what? 10 different pieces