EE 4BD4 Lecture 21 Cardiac Pacing.

Slides:



Advertisements
Similar presentations
Appendix E Pacemakers Gail Walraven, Basic Arrhythmias, Seventh Edition ©2011 by Pearson Education, Inc., Upper Saddle River, NJ.
Advertisements

EE 4BD4 Lecture 20 Therapeutic Stimulation 1. 2 Weak and Strong Stimulation Recording Amplifier AC Coupled (bad choice) 3.
Current And Resistance
The Very Basics of Pacing Glenn Estell Medtronic Pribcipal Clinical Specialist.
Aims Introduction to the heart.
The right side of the heart pumps blood out into and through the lungs. The blood returns on the left side of the heart, which pumps the blood out through.
Chapter 17 Current Electricity. Conductors  Conductors are materials in which the electric charges move freely Copper, aluminum and silver are good conductors.
Chapter 13-Webster Therapeutic and Prosthetic Devices
Superconductors A class of materials and compounds whose resistances fall to virtually zero below a certain temperature, T C T C is called the critical.
Chapter 17 Current and Resistance. Electric Current Whenever electric charges of like signs move, an electric current is said to exist The current is.
Pacemakers and Implantable Cardioverter-Defibrillators
Appendix E Pacemakers Gail Walraven, Basic Arrhythmias, Sixth Edition ©2006 by Pearson Education, Inc., Upper Saddle River, NJ.
Rafael Ortega, MD Boston University Medical Center External Pacemakers.
Chapter 13. Therapeutic and Prosthetic Devices Michael R. Neuman
Pacemakers and Implantable Defibrillators
1 BME 251 Lab sections Monday and Wednesday, 9-12 or 1-4 Lecture 12:10-12:50 Wed –Starting and finishing with 10 minutes to spare…people have lab just.
Lecture 4 Defibrillator
ENTC 4350 DEFIBRILLATOR & PACE MAKERS. DEFIBRILLATOR.
Problems of creating physiologically matched artificial cardiac pacemakers Sergei Ovsjanski Tallinn University of Technology 2009.
Pacemaker & its Classification
Dr. Ali Saad, BMT department1 Dr. Ali Saad, Biomedical Engineering Dept. College of applied medical sciences King Saud University BMT414 Biomedical Engineering.
Pacemakers and Implanted Defibrillators Mike Harlan.
Dr. Nitish V. Thakor Biomedical Instrumentation
Single Chamber Temporary Pacing Operations & Troubleshooting.
Pacemakers Q-1. What do you mean by pacemaker?
Elsevier items and derived items © 2006 by Elsevier Inc. Chapter 37 Interventions for Clients with Dysrhythmias.
Figure 13.1 Block diagram of an asynchronous cardiac pacemaker
Lecture 5 Cardioverter& Pacemakers
Electricity and Magnetism Electrostatics Capacitance and Capacitive Circuits.
Cardiovascular System
1 BMT414 Pacemakers Dr. Ali Saad, Biomedical Engineering Dept. College of applied medical sciences King Saud University.
Lecture 8 Electrical energy EMF Resistors in series and parallel
Chapter 13. Therapeutic and Prosthetic Devices Michael R. Neuman Medical Instrumentation Application and Design, 4th Edition John G. Webster, Univ. of.
ELECTRODES FOR STIMULATION. Cardiac Pacemakers and Defibrillators  The heart is a natural example of a critical Bioelectromagnetic system.  An electrocardiogram.
EE 4BD4 Lecture 24 Defibrillator Biomedical Device Technology: Principles and Design, Charles C. Thomas Publisher 2007 Anthony K. Chan 1.
The Hearts Electrical Activity
Cardiac Pacemakers © D. J. McMahon 2012 rev
Cardiovascular System PowerPoint Presentation Circulatory and Respiratory Unit PSE 4UI.
NEED FOR CARDIAC PACEMAKER Rhythmic beating of heart originates from SA node If SA node doesn’t function properly results in decreased heart rate & change.
How the Heart Works. Electrical activity in the heart.
Electric Circuits Voltage Measurement. Current Measurement.
Heart Beat and Blood Pressure. Heart Beat Animation ions/ ions/
Electrocardiograph. History Italian scientist Carlo Matteucci realizes that electricity is associated with the heart beat Irish scientist.
EE 4BD4 Lecture 22 Electrical Safety Electrode on Skin 4.
IP d.c. devices © Oxford University Press 2011 d.c. devices.
Defibrillators WHO. “Defibrillator, External, Automated; Semiautomated.” From the publication: Core Medical Equipment. Geneva, Switzerland, 2011.
E LECTRONIC P ACEMAKER Dancho Grigorios B070049EC.
Cardiovascular Therapeutic Management 2013
Circulatory System Conductive Pathway.
Direct Current A Direct Current (or DC) power supply moves electrons through the wire in ONE DIRECTION ONLY. For an electron to deliver its energy to the.
Basics of Pacemaker Functioning
BME 312 BIOMEDICAL INSTRUMENTATION II LECTURER: ALİ IŞIN LECTURE NOTE 1 CARDIAC PACEMAKERS BME 312-BMI II-L1- ALİ IŞIN 2015 FACULTY OF ENGINEERING DEPARTMENT.
BME 311: BIOMEDICAL INSTRUMENTATION I Lecturer: Ali Işın
Objectives Identify the components of pacing systems and their respective functions Define basic electrical terminology Describe the relationship of amplitude.
CARDIAC PACEMAKER Ms. Saranya N 27-Feb-18 Cardiac Pacemaker.
Objective 12 Electrocardiograms
Circulatory System Conductive Pathway
Biomedical Instrumentation
Pacemaker II Lecture (6).
Therapeutic equipment I
Cardiac Pacemakers new 10 Oct 12 D McMahon.
PACEMAKER Yoga Yuniadi
CARDIAC PACEMAKER A cardiac pacemaker is an electric stimulator that produces electric pulses that are conducted to electrodes normally located within.
EKGs and Pacemakers Cooper University Hospital
CARDIAC DEFIBRILLATORS
Diathermy and its safe use
Conductive Pathway DHO8 7.8 pg. 192 HS1/
Circulatory System Conductive Pathway
CARDIAC DEFIBRILLATORS
Heart Beat and Blood Pressure
Presentation transcript:

EE 4BD4 Lecture 21 Cardiac Pacing

Electrical Pathways of the Heart

Type I Heart Block

Type 2 Heart Block

Type 3 Heart Block

History 1774 Aldini electrically resuscitated a 3 year old child Over next 2 centuries scientists experimented with electrical cardiac stimulation cardiac First electrostatic charges and later a-c and d-c currents 1932 Alfred Hyman developed the first device to stimulate the heart electronically. Delivered 3 mA pulses directly to heart using needle electrodes Coined the term pacemaker 1947 Beck reported a successful cardiac defibrillation 1952 Paul Zoll reported a closed-chest external electrical cardiac pacemaker using surface electrodes, 2 ms pulses, 100-200 mA Caused pain and burns

History (cont’d)

History (cont’d)

History (cont’d) 1960 Chardack and Greatbach implanted a pacemaker Examples:

First Type of Pacemaker Developed complete heart block only

Pacemaker Specifications Power supply: lithium type (iodide) long life 5 -10 years (early batteries 2 years max) Oscillator: (fixed rate) set at 70 – 90 beats/min Output circuit: Constant voltage 5.0 to 5.5, 500 – 600 µs duration; constant current 8 – 10 mA, 1.0 – 1.2 ms Lead wires: inter-wound helical coils spring-wire alloy (fatigue resistant) in silicone rubber or polyurethane cylinder Electrodes: unipolar or bipolar (unipolar return electrode on case) platinum alloys such as platinum iridium (biocompatible and inert)

Demand Inhibit (synchronous) incomplete heart block Most current single lead types (avoids stimulating during naturally occurring T-wave to avoid sending heart into fibrillation) Saves energy since pulse sent out only when needed Stimulating electrode senses QRS and resets timer Rest of circuit same as asynchronous

Atrial Synchronous Assumes SA node functional 120 ms delay allows ventricles to fill during atrial contraction 500 ms delay locks out circuit to avoid QRS pulse from triggering another stimulus

Activity or Demand Responsive Pacemakers

Temporary External Pacemakres

Lead Placements