LHC Emittance Preservation MD 3 - Preliminary Results 11.10.2012 M. Kuhn, V. Kain, G. Arduini, J. Emery, W. Hofle, A. G. Ollacarizqueta, F. Roncarolo,

Slides:



Advertisements
Similar presentations
MD#2 News & Plan Tue – Wed (19. – 20.6.) DayTimeMDEiCMP Tue06: GeV  4 TeV: Ramp for chromaticity - missed A 08:00Ramp down 10: GeV: Large.
Advertisements

Lot’s of time lost due to cryo problem in IR8. Major impact, therefore review of MD program… Start discussion here, please let us know your input. Will.
Where did all the protons go? Mike Lamont LBOC 20 th January 2015.
LHC Emittance Measurement Preparation during LHC Commissioning LBOC Meeting February 17, 2015 Maria Kuhn – February 17, 2015.
Saturday 6:13 – 15:00 STABLE BEAMS  scans etc. 15:00 moved to ADJUST Squeeze to 2 m in two steps 11 – 5 – 2  remarkably smooth  tertiary collimators.
Monday 29 October 08:48 V/dM scan CMS end of fill #3236. Check of “fast scan”. 10:06 V/dM scan finished, start of RF studies, reducing RF voltage. 11:10.
LHC First LHC Emittance Measurements at 6.5 TeV IBIC15 Melbourne, Australia 2015 Maria Kuhn 1,2 – September 16, 2015 F. Antoniou 2, E. Bravin 2, B. Dehning.
Thursday 21/4 07:30: End of fill #1727. Beam dumped. ALICE compensator magnet fault. Delivered ~6.7 pb -1 in 7.5 h. 11:30 Stable beam # bunches/beam.
CONTENT: Beam characteristics and parameters Filling schemes Operational settings OP procedure and COLL setting Planning Shift breakdown To define the.
:00: Prepared new fill B1: Q X =0.293, Q Y =0.269; lifetime = 25h ✔ B2: Q X =0.297, Q Y =0.267; lifetime = 5h ✗ Strong 50Hz and 100hz lines.
Beam Commissioning WG, 10 August Luminosity Scans in the LHC S. White.
LHC progress Report LHCC Wednesday 23 rd March 2011.
LHC Coping with Emittance Measurement Challenges in the LHC after LS1 Gentner Day October 2014 An Overview of Control and Data Flow Related to LHC Emittance.
LHC LHC Emittance Measurements and Preservation LBOC Meeting July 28, 2015 Maria Kuhn – July 28, 2015 Many thanks to G. Baud, E. Bravin, B. Dehning, J.
Evian 2014 historical perspective run 1: 2010: L peak >10 32 cm -2 s -1  2x10 32 cm -2 s : produce >1 fb -1  delivered.
Machine development - results and plans – critical results, what’s to be done? R. Assmann 15/07/2011 R. Assmann for the LHC MD coordination team (R. Assmann,
Tuesday 17 th April 04:00 Prepare second fill for v/d Meer scans. 06:22 Stable beams, v/d Meer scans for Alice and LHCb. 13:20 End v/d Meer scans.Dump.
Comparison between simulations and measurements in the LHC with heavy ions T. Mertens, R. Bruce, J.M. Jowett, H. Damerau,F. Roncarolo.
BSRT CALIBRATION MD SUMMARY LSWG #6-15/09/2015 BSRT TEAM.
LHC Progress Friday 30 th October 2015 Coordination Week 44: Massimo Giovannozzi, Wolfgang Hofle, Jorg Wenninger.
ADT Tune Measurement F. Dubouchet, W. Hofle, D. Valuch Acknowledgement: R. Calaga, F. Roncarolo, E. Bravin, shift crews New developments and tests on August.
● 08h00: Adjust mode for end-of-fill study. Scraping test for determining transverse beam profile (beam 2, vertical). As expected, beam dumped with BLM.
LHC Progress Thursday 29 th October 2015 Coordination Week 44: Massimo Giovannozzi, Wolfgang Hofle, Jorg Wenninger.
LHC LHC performance with low-emittance h=9 beam Focus on emittance preservation M. Kuhn, H. Bartosik, B. Dehning, A. Guerrero Ollacarizqueta, V. Kain,
Shortened program (2 days), as decided in LMC. MD program worked very well  all MD’s on plan with ~foreseen beam time. LHC in very good shape with excellent.
LHC Updates on the LHC Wire Scanner Application --- Transverse Emittance Blow-up during the LHC Ramp Verena Kain, Maria Kuhn 1 11/12/2013.
LHC First LHC Emittance Measurements at 6.5 TeV Emittance Meeting August 26, 2015 Maria Kuhn – August 26, 2015 Many thanks to G. Baud, E. Bravin, B. Dehning,
Beam-Beam head-on Limit J. Barranco, X. Buffat, T. Pieloni, C. Tambasco, J. Qiang, K. Ohmi, M. Crouch for the Beam-Beam team BI BSRT Team George and Enrico.
Tuesday 24 th July - morning 10:15 Operator dump of fill 2873  Initial luminosity: 5.83e33 cm-2s-1  12 hours stable beams  151 pb-1 delivered  Initial.
Cryo back at 17:30 Beam back at 19:00 IR2 aperture until ~03:00 Since then no beam from the SPS:  Connector problem on MKD  Connector eroded, needs to.
MD377 Schottky diagnostic M. Wendt, M. Betz, T. Lefevre.
Crossing Schemes Considerations and Beam-Beam Work plan T. Pieloni, J. Barranco, X. Buffat, W. Herr.
(Towards a) Luminosity model for LHC and HL-LHC F. Antoniou, M. Hostettler, Y. Papaphilippou, G. Papotti Acknowledgements: Beam-Beam and Luminosity studies.
AB-ABP/LHC Injector Synchrotrons Section CERN, Giovanni Rumolo 1 Preliminary results of the E-Cloud Instability MDs at the SPS G. Rumolo, in.
LHC LHC Wire Scanners: Updates on Measurement Accuracy Emittance Meeting 18 November 2015 Maria Kuhn – 18 November 2015 Many thanks to G. Baud, E. Bravin,
Tuesday 7 th August - morning 07:10 Reinjection after loss of fill 2920 to UFO near ALICE  26 pb -1 in 1h16m; peak lumi 6.4e33 cm -2 s -1 08:10 dump at.
:30 meetingEBH 1  No beam during the morning:  4:15 – 9: V distributor: Recovery after electrical interruption  access for TI services.
LHC Wire Scanner Calibration
Ralph Assmann, Giulia Papotti, Frank Zimmermann 25 August 2011
Cryo Problem MD Planning Tue (1.11.) C B Day Time MD MP Tue 01:00
MD #453 Effect of low frequency noise
Wire, flat beams and beam-beam MDs in 2017
Saturday 21st April 00:33 Interlock during ramp on BLM HV
MD Report 24 June 2012 Machine coordinators: Barbara Holzer, Mike Lamont MD Coordinators: Ralph Assmann, Giulia Papotti, Frank Zimmermann MD#2 News & Plan.
MD2490: Measurement of the TMCI Threshold at Flat-Top
LHC Emittance Measurements and Preservation
LHC summary week 32 Coordination: Mike Lamont & Jan Uythoven
MD25 ns - 14/12/2012 G. Arduini, H. Bartosik, G. Iadarola, G. Rumolo
LHC Morning Meeting - G. Arduini
Fill 1410 revisited Peak luminosity 1.4e32 Beam current 2.68/2.65 e13
Wednesday /Thursday 09-11:00 Verification of the LSS6 interlocked BPMs: took longer to fill due to some problems with RF cavities in the PS. In the mean.
Wednesday Morning 8: :30 end of fill study - octupole polarity inversion (Elias, Tatiana, Alexey, Georges, …): Goal: study the effect of the.
MD#4 Progress MD Coordinators: Giulia Papotti, Frank Zimmermann
LHC Morning Meeting - G. Arduini
Summary of Week 26 Main aims: G. Arduini, B. Holzer, M. Lamont
Friday morning 10:30 Optics measurements and corrections.
Saturday 7th May Sat – Sun night
(on behalf of the LHC team)
Summary Thursday h21: Stable beams fill #1303.
Summary of week 19 Machine Coordinators: G. Arduini, M. Lamont Main aim: Luminosity production.
MD#2 News & Plan Tue – Wed (19. – 20.6.)
Thursday 26th July 13:21 Fill 2880 beam dumped
Thursday – Morning Energy matching at injection with H CODs
Collective effects in the SPS and LHC (longitudinal plane)
Summary for LPC (March 7th, Ralph Assmann)
LHC Morning Meeting - G. Arduini
Wednesday h18: 228b fill lost just before start of ramp.
Another Immortal Fill….
Wednesday :35 : Beam lost because of trip of RCBXH3.L1
Monday 152 bunch operation summary
Presentation transcript:

LHC Emittance Preservation MD 3 - Preliminary Results M. Kuhn, V. Kain, G. Arduini, J. Emery, W. Hofle, A. G. Ollacarizqueta, F. Roncarolo, R. Steinhagen, D. Valuch 1

LHC MD Goals oNoise effect, 50 Hz lines oTransverse damper effect oWire scanner photomultiplier saturation oComparison with experiment data and LHCb SMOG oAlso from beta-beating team: optics through the ramp − To be analyzed 2

LHC Programme oInjection: − Check 50 Hz noise line − Check PM saturation oRamp: − With different damper gains and longitudinal blow-up oFlattop: − Check PM saturation oCollision: − Take ATLAS/CMS luminosity data − Take ATLAS/CMS luminous region data − Inject SMOG at LHCb Velo for beam size measurements oInstrumentation − Wire scanner always  Emittances averaged over 6 bunches of one batch  Errors include fitting error (used core fit), beta function error and error from averaging  Beta function from k-modulation − BSRT at injection and squeeze (to be analyzed) 3

LHC Noise Line Studies at 450 GeV oInject 2 x 6 nominal 50 ns bunches oIntensity: 1.3 x ppb oFillnumber 3159 − Trim tune to 0.28/0.31 (50 Hz line) − Unexpected beam dump, re- injection − Move tune to 0.282/0.31 − Tune back to 0.28/0.31 oWhat is going on in the vertical plane? − Only changed horizontal tune! ohorizontal plane not clear yet − IBS anyways 4

LHC PM Saturation at 450 GeV oInject 5 x 6 nominal 50 ns bunches − Change filters and voltage of wire scanners − Horizontal plane: emittance growth due to IBS − BUT: vertical plane also growing − Clearly filter and gain selection have an influence on the beam size − Preliminary: best working point for ramp: low transmission + high voltage 5

LHC oRe-inject 5 x 6 nominal 50 ns bunches − Unexpected beam dump after ramp  Due to beam loss in point 4 during wire scan WS threshold changed to 3.6 x  Beam dump still under investigation (beam size, wire thickness, change of system?) oLower intensity: 1.0 x ppb oFillnumber 3160 oRe-inject 4 x 6 nominal 50 ns bunches − Still very high losses in point 4 during wire scans!!! The Ramp 6 Usually all planes are shrinking except for B2H – here reversed But for the first ramp with 30 bunches: no shrinkage at all! Optics? Transverse instabilities due to short bunch lengths?

LHC oLarge blow-up for low gain bunches oColliding and non-colliding high gain bunches look good oAll other planes look the same, except B1H Transverse Damper Effect 7 Very low gain (sacrificial) Low gain sacrificial High gain (colliding) High gain

LHC ofilter and gain selection have an influence on the emittance − Changes the normalized emittance up to 1  m! oBest settings are still under investigation PM Saturation at 4 TeV 8

LHC Wire Scanner vs Luminosity oConvoluted emittance: − Used measured beta from k-modulation at β * = 0.6m for wire scanners − Only batch 4 ( average over 6 bunches) are colliding  Luminosity: β * error of 15 %, crossing angle error 15 μ rad oEmittances from wire scans significantly smaller than emittances from luminosity − Also large difference between ATLAS and CMS − Also unknown error on wire scanner measurements due to PM saturation  Emittances measured approx. too small oTo be checked: luminous region (no data at peak luminosity) − Bunch-by-bunch beam sizes of colliding bunches in IP1 and IP5 9 Wire ScanFrom ATLAS Luminosity From CMS Luminosity ε L [μm]1.39 +/ / /- 0.27

LHC Wire Scanner vs SMOG oWork still in progress oLHCb could measure all bunches, no collisions in IP8 10 Colin Barschel Very low gain (sacrificial, long range collisions IP1,5,8) High gain (long range collisions IP1,2,5) (head- on collisions IP1,5) High gain (no collisions) Low gain (long range collisions IP1,5) Beam 2: IP8 IP1,2,5

LHC THANKS TO EXPERIMENTS FOR SMOG DATA AND BUNCH-BY-BUNCH LUMINOUS REGION. VERY EFFICIENT COLLABORATION. 11

LHC BACK-UP 12

LHC Motivation oFrom previous measurements: puzzling effects − Vertical plane growing at injection − Emittance shrinkage during the ramp − Emittance from luminosity larger than from wire scanners oAlready checked: − Wire scanner calibration − Collimator setting − Optics at injection, flattop and squeeze (so far linear interpolation for the ramp) 13

LHC Noise Lines – All Planes 14

LHC PM Saturation at 450 GeV – All Planes 15

LHC First Ramp – All Planes 16 Wire scanner filter: 2 % - 1 % Wire scanner gain: 1400 V – 900 V

LHC Second Ramp – All Planes 17 Wire scanner filter: 0.2 % Wire scanner gain: 2200 V – 1000 V

LHC The Squeeze 18

LHC Damper Gain – All Planes 19 Batch 2 too small reversed ??? reversed

LHC PM Saturation at 4 TeV – All Planes 20

LHC Test Cycle with 12 Bunches oFill 3217 o2 x 6 nominal 50 ns bunches oMeasured with wire scanners through the whole cycle − With 0.2 % transmission, only gain change (same settings as for fill 3160) 21 artifact