1 Status of PT Cryocooler for Final Calorimeter KEK, ICEPP Tom HARUYAMA / Satoshi MIHARA MEG Pre-Meeting 1. Heat load and PT cryoooler 2. Further test and schedule
2 -Heat Load- -Based on the KEK-original PT cryocooler, Cryocooler with higher cooling power has been developed for the final calorimeter
3 Large Power Pulse Tube Cryocooler Technology transfered to Iwatani Co., Ltd Designed: 150
4 Large Power Pulse Tube Cryocooler Technology transfered to Iwatani Co., Ltd. One for Columbia University For Dark Matter Research Designed: kWcompressor
5 Large Power Pulse Tube Cryocooler - Technology transfered to Iwatani Co., Ltd. - Two for MEG Designed: using 6.7kW compressor
6 Large Power PT Cryocooler -Cooling power at 6.7kW compressor- KEK original for Large Proto For final calorimeter 6.7kW, 4Hz
7 Results and Further Tests -Achieved cooling power of 190W at 165K (6.7kW compressor) -Orientation dependence test... Horizontal layout for the case of two cold head -Another phase shift configuration (Double Inlet) test... To increase cooling power Schedule -January 2004:Final parameter fixed -February 2004:Fabrication will start -March 2004:Will be delivered (two sets) -Can be installed for the LXe liquid purification test