Modification of Geant4 simulation Detailed crystal structures included reference materials real geometry.

Slides:



Advertisements
Similar presentations
Topic 8. Gamma Camera (II)
Advertisements

NUCP 2371 Radiation Measurements II
Development of Germanium Detector Simulations with the Geant 4 Toolkit Andrew Mather 12th UK Postgraduate Nuclear Physics Summer School.
Single Planar Detector Monte Carlo Simulations Andrew Mather
Dante Nakazawa with Prof. Juan Collar
Gamma-Ray Spectra _ + The photomultiplier records the (UV) light emitted during electronic recombination in the scintillator. Therefore, the spectrum collected.
1 Continuous Scintillator Slab with Microchannel Plate PMT for PET Heejong Kim 1, Chien-Min Kao 1, Chin-Tu Chen 1, Jean-Francois Genat 2, Fukun Tang 2,
GEANT4 Simulations of TIGRESS
High granularity to reduce the effect of the “prompt flash” radiation Polarization sensitivity Imaging capabilities for background suppression DESPEC (DEcay.
1 MCP PET Simulation # of photon detected at photocathode 2. Efficiency & Material effect # of generated photon at 511keV 26000/MeV * =
Geant4 simulations for the calorimeter prototypes D. Di Julio, J. Cederkäll, P. Golubev, B. Jakobsson Lund University, Lund, Sweden.
Geant4 simulations for the calorimeter prototypes D. Di Julio, J. Cederkäll, P. Golubev, B. Jakobsson Lund University, Lund, Sweden.
Pair backgrounds for different crossing angles Machine-Detector Interface at the ILC SLAC 6th January 2005 Karsten Büßer.
Neutron Gamma Discrimination in Agata Possibility of discriminating neutrons and gammas by tracking Identify the neutron interaction points in Agata detectors.
Measurements of IAEA reference materials with Ge detectors at LNGS Claudia Tomei - LNGS ILIAS JRA1 – WP4 Radiopurity of Materials.
Grupo de Física Nuclear Experimental G F E N CSIC I M E Towards a Frontcap design M. Turrión 1, O. Tengblad 1, A. Perea 1, B. El Bakkari 2 1 IEM-CSIC,
AGATA Demonstrator Test With a 252 Cf Source: Neutron-Gamma Discrimination Menekşe ŞENYİĞİT.
News from the GRETINA TRACKING group New in tracking: We can track Geant4 (G4) simulated data Using both the (1) original AGATA code simulations (with.
H. Alvarez Pol - NUSTAR Calorimeter WG R3B/EXL Collaboration Meeting - Santiago Sept Geometrical design, simulation progress and first detector.
Workshop on Physics on Nuclei at Extremes, Tokyo Institute of Technology, Institute for Nuclear Research and Nuclear Energy Bulgarian Academy.
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
Gamma calorimeter for R3B: first simulation results INDEX ● The calGamma Geant4 simulation ( a short introduction ) ● Crystal and geometry selection: –
R 3 B Gamma Calorimeter Agenda. ● Introduction ● Short presentation on the first ● Task definition for R&D period ( )
St. Petersburg State University. Department of Physics. Division of Computational Physics. COMPUTER SIMULATION OF CURRENT PRODUCED BY PULSE OF HARD RADIATION.
Integration of a Clover Detector with the necessary electronics and computer program to utilize the ADDBACK method An SP496 and Capstone Research Project.
SuperNEMO Simulations Darren Price University of Manchester July, 2005.
Pedro Arce Introducción a GEANT4 1 GAMOS tutorial Plug-in’s Exercises Pedro Arce Dubois CIEMAT
GERMANIUM GAMMA -RAY DETECTORS BY BAYAN YOUSEF JARADAT Phys.641 Nuclear Physics 1 First Semester 2010/2011 PROF. NIDAL ERSHAIDAT.
Special Topics in Nuclear Physics, JU, Second Semester, (Saed Dababneh). 1 Course web or
Source flux accuracy from BLC analysis A. Strong MPE June 2002.
Energy Loss Toshiyuki Gogami 15Apr2013. Simulation Particles are generated at the center of target Randomly generation points are moved in the target.
Pedro Arce Introducción a GEANT4 1 GAMOS tutorial Compton Camera Exercises
Accelerator Physics, JU, First Semester, (Saed Dababneh). 1 Principles of Spectrometry.
Experience With CBM Muon Simulation Partha Pratim Bhaduri.
Simulation of the energy response of  rays in CsI crystal arrays Thomas ZERGUERRAS EXL-R3B Collaboration Meeting, Orsay (France), 02/02/ /03/2006.
Detector Simulation Presentation # 3 Nafisa Tasneem CHEP,KNU  How to do HEP experiment  What is detector simulation?
Digital primary electron counting: W, Fano Factor, Polya vs Exponential M. Chefdeville, NIKHEF, Amsterdam RD51, Paris, October 2008.
DESPEC A Algora IFIC (Valencia) for the Ge array working group.
Junior Comprehensive Chuna Bremsstrahlung Interactions that occur after Beta Minus Decay.
Determination of activity of 51 Cr source on gamma radiation measurements V.V.Gorbachev, V.N.Gavrin, T.V.Ibragimova, A.V.Kalikhov, Yu.M.Malyshkin,A.A.Shikhin.
LArGe-MPIK progress report physics validation of MaGe comparison with LArGe-MPIK: (preliminary) results GERDA collaboration meeting Dubna, June 26 th -29.
Simulation of HPGe detector efficiency Eunkyung Lee Ewha Womans University.
Tracking Background GRETINA Software Working Group Meeting September 21-22, 2012, NSCL MSU I-Yang Lee Lawrence Berkeley National Laboratory.
30/8/05Lisa Fogarty Testing Detector Arrangements For 22 Na(p,γ) Experiment.
BESIII EMC Simulation & Reconstruction He Miao
GEANT and Veto Updates M. H. Wood University of Massachusetts, Amherst.
EXPERIMENTS WITH LARGE GAMMA DETECTOR ARRAYS Lecture II Ranjan Bhowmik Inter University Accelerator Centre New Delhi
PoGO_G4_ ppt1 Study of optimized fast scintillator length for the astronomical hard X- ray/soft gamma-ray polarimeter PoGO November 1, 2004 Tsunefumi.
Seoul National University Han-wool Ju CUNPA Kick-off Meeting Aug.22-23, 2013.
Institute of Basic Science Rare Isotope Science Project PANGEA P hoton detector system for A stro-science and N uclear physics with GE rmanium A rray 2015.
SIMULATION OF BACKGROUND REDUCTION TECHNIQUES FOR Ge DBD DETECTORS Héctor Gómez Maluenda. University of Zaragoza. GERDA/Majorana MC Meeting.
Positronium intensity measurement preparation SNU Bongho Kim.
The Status of Hyperball-J Akio Sasaki Dept. of Phys. Tohoku Univ. 23/9/2011.
Pedro Arce Introducción a GEANT4 1 GAMOS tutorial Spectrometry Exercises Pedro Arce Dubois CIEMAT
Performance of scintillation pixel detectors with MPPC read-out and digital signal processing Mihael Makek with D. Bosnar, V. Gačić, L. Pavelić, P. Šenjug.
GAMOS tutorial PET Exercises
Calibration of swept charge devices (CCD-54)
GAMOS tutorial PET Exercises
PARTICLE FLUX CALCULATION-III
The Hadrontherapy Geant4 advanced example
Add or Subtract? x =.
MCP PET Simulation (7) – Pixelated X-tal
GAMOS tutorial Plug-in’s Exercises
clustering : deterministic annealing filter (DAF)
Test Setup SiPM Hamamatsu S C Pixel size( 25um)
Physics event timing Use Pythia to generate hadronic decays at 125 GeV
Status Report on MCP PET Simulation
Practice Geometry Practice
Presentation transcript:

Modification of Geant4 simulation Detailed crystal structures included reference materials real geometry

Checking of single Clover against NaI Clover NaI (φ7.62cm×7.62cm) NaI + source (25 cm away) for checking of the absolute photopeak efficiency 1330 keV gamma 10 6 events generated photo peak countdetection efficiency NaI ×10 -3 Clover Crystal # % (Relative) Clover Crystal # % (Relative) Clover Crystal # % (Relative) Clover Crystal # % (Relative) before Add back % (Relative) after Add back % (Relative) add-back factor: 1.54 Literature value: 1.2X10 -3

Energy [keV] photo peak efficiency [%] after Add back before Add back Geant4 simulation Detector geometry