Robert E. Synovec CPAC Department of Chemistry University of Washington Robert E. Synovec CPAC Department of Chemistry University of Washington.

Slides:



Advertisements
Similar presentations
Cruces-Blanco, C., Gamiz-Gracia, L., Garcia-Campana A.M., Applications of Capillary Electrophoresis in Forensic Analytical Chemistry Trends in Analytical.
Advertisements

The Foundations: Classical Split and Splitless Injection
ANALYTIC METHODS II. PART Jana Švarcová.  Chromatography  Electrophoresis  Potentiometry  Titration  Spectrophotometry.
Caffeine as a Surrogate for Cocaine in an HPLC Forensic Experiment Ray A. Gross Jr, Indravadan Shah and Muhamed Jasarevic Department of Physical Sciences.
KROMATOGRAFİ Sedat Türe. HPLC Liquid Chromatography.
© Copyright 2002 ABB. All rights reserved. - Microelectromechanical Systems for Process Analytics IFPAC 2003 Dr. Berthold Andres ABB Automation Products.
PRINCIPLE AND INSTRUMENTATION OF CAPILLARY ELECTROPHORESIS
Results Initial chromatographic conditions [Figure 2a caption] for the separation of the degradation products of aspirin were problematic due to the long.
Lecture 8. GC/MS.
LC/MS WORKSHOP IOWA STATE UNIVERSITY Kamel Harrata  Instrument Description  Data Acquisition  Data Processing.
B IOCHEMICAL INSTRUMENTAL ANALYSIS -11 Dr. Maha Al-Sedik.
Pn. Suryati Bt. Syafri 2009 High Performance Liquid Chromatography (HPLC)
CHAPTER 29 Supercritical Fluid Chromatography The mobile phase is a supercritical fluid (a fluid above its critical T and critical pressure) Supercritical.
Effect of Packing Particle Size on Plate Height. Resolution between 2 adjacent peaks.
Institute of Chemical Sciences
High Performance Liquid Chromatography High Performance Liquid Chromatography Chem. 331.
Prabh Jassal SUPA Che113 Forensics Ms. Tolentino.
Introduction to High Performance Liquid Chromatography.
Drs. Wei Tian & Yanhui Chen Sep-Dec Main Content Chromatography Analysis Gas Chromatography (GC) High Performance Liquid Chromatography (HPLC)
Chapter 27 Gas Chromatography 1. Principles
High Performance Liquid Chromatography
Progress Report on Miniaturized Liquid Chromatography for NeSSI Scott Gilbert, CPAC Visiting Scholar Crystal Vision Microsystems LLC Atofluidic Technologies,
Method conditions Excellent resolution and fast run times 2 x OligoPore, 4.6 x 250 mm columns gave excellent oligomeric resolution for the PS 580 sample.
GC Advantages 1. Very Large N (Very Long Columns) 2. No Packing Material (A=0) 3. Simple Mobile Phase (Compressed Gas) 4. Universal Detectors (FID) 5.
Flow cell design for WGM optical biosensor Yongqiang Yang BE8280 spring 2015.
Using Linear Scale-up Principles and the Varian 940-LC with Scale-Up Module for the Isolation of 5-Hydroxytryptophan from Griffonia Simplicifolia Dennis.
History of Chromatography n Early LC carried out in glass columns n diameters: 1-5 cm n lengths: cm n Size of solid stationary phase n diameters:
Developing a Method for Measuring Amlodipine Levels in Cat Plasma By:Preston Bull Advisors: Mike Gallagher, Dr. Webster.
Simultaneous determination of inorganic anions and cations by capillary electrophoresis with indirect UV detection I. Haumann, J. Boden, A. Mainka, U.
Interfacing Gas Chromatography with Mass Spectroscopy and Infra Red Spectroscopy Is this a large expensive detector…. Or a separation prior to analysis….
Chem. 231 – 2/18 Lecture. Announcements Set 2 Homework – Due Wednesday Quiz 2 – Next Monday Set 1 Labs –should be switching instruments today (or after.
Gas Chromatography Lecture 38.
Capillary Electrophoresis (CE) PHAR Lecture Objectives By the end of the lecture, students should be able to: 1.Illustrate the CE instrumental.
Practical Applications of Raman Spectroscopy for Process Analysis
By- Bhavya, Harsh, Harshvardhan, Namrata, Ronit and Vidhatri
Progress Report on Miniaturized Liquid Chromatography for NeSSI
HPLC – High Performance Liquid Chromatography
SSI Binary Gradient Pump Modular Simplicity. Ideal Gradient Characteristics Modular design Small foot print Easy Maintenance Compatible with stand alone.
Microfluidics: introduction
LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY
1 Gas Chromatography Lecture Liquid Stationary Phases In general, the polarity of the stationary phase should match that of the sample constituents.
HPLC.
Biochemical instrumental analysis - 11 Dr. Maha Al-Sedik 2015 CLS 332.
LC/MS Chromatography Systems 212-LC. 2 The Complete Solution Varian LC components, pumps, autosamplers and the New MS Workstation SW (V6.6) can be used.
Liquid Chromatography 2: New Technology Lecture Date: April 3 rd, 2007.
Process Control of Esterification in a NeSSI-Based Micro-Reactor by Raman Spectroscopy Stuart Farquharson, Chetan Shende, Frank Inscore, and Wayne Smith.
Selling Restek LC Solutions for Analytical Scale Laboratories Rick Lake Product Line Manager Liquid Chromatography x 2379
Downloaded from کروماتوگرافی CHROMATOGRAPHY Downloaded from
Microsystems for selective gas sensing
Reading assignment: section 26E(p781) Chapter 26 # 2, 3, 14, 15, 16 Chapter 27 # 7(a,d,f), 22, 23, 24, 25.
High Performance Liquid Chromatography Presented by Dr. Kamal Modi 2 nd Year Resident.
LIQUID CHROMATOGRAPHY
Chromatography- TLC & HPLC
Mass Spectrometry Vs. Immunoassay
Microsystems for selective gas sensing
HPLC Equipment : Detectors
Size Exclusion Chromatography (SEC)
August 23, 2000 R.N. Dubois Dow Chemical
Pure Carrier Gas Grades (subjective)
High Performance Liquid Chromatography
BASICS OF SUPERCRITICAL FLUID CHROMATOGRAPHY
Retention and phase distribution
Chromatography Daheeya Alenazi.
High Performance Liquid Chromatography (H. P. L. C. ) dr. Sham b
Introduction to the NGC Chromatographic System
High-Performance Liquid Chromatography
Selvadurai Muralidharan, Jayaraja kumar, Venugopal Vijayan
Transferring LC-UV to LC-MS.
High performance liquid chromatography (HPLC)
High-Performance Liquid Chromatography
Presentation transcript:

Robert E. Synovec CPAC Department of Chemistry University of Washington Robert E. Synovec CPAC Department of Chemistry University of Washington

LC-related Technologies and NeSSI Compatibility On-line, real-time analysis of mixtures: > Drugs and Pharmaceuticals > Environmental Samples > Petroleum Industries > Clinical Chemistry > Pesticides and Their Residues > Foods Development of analytical instrumentation: > Small-volume and microfabricated LC > Micro-scale Molecular Weight Sensor (  -MWS) > Sampling

NeSSI Compatibility Requirements and Challenges What should we strive for in instrument development in order to provide lab-based LC performance in a process LC analyzer? Low – pressure, flow rate (low waste), maintenance High separation efficiency (optimize peaks/time) Broad range of chemical selectivity Robust and quantitative sampling (readily calibrated) FINALLY: Scaled & implemented so readily interfaced to NeSSI hardware WHILE minimizing dead volumes

We need to consider: New products and new implementation New research level systems (that show promise) IDEAS: > Monolithic columns (perform well and low pressure drop is good, but need smaller id columns are needed) > Capillary columns (everything is good, need more work here), LC on-a-chip >  -MWS (size information without Chromatography!) > H-filter sampling

High speed LC of anions using a monolithic column: Very low pressure, but at ~ 5 mL/min (due to 4.6 mm id column) Reference P. Hatsis, C. A. Lucy, Anal. Chem. 2003, 75, 995 – 1001.

LC vs. Micro-fabricated LC Lab ScaleMicrofabricated Column Diameter4.6 mm10  m x 100  m Flow Rate1 mL/min10 nL/min Waste Generated 500 L/year5 mL/year Sample Used10  L1 nL or less Pump Pressure1000 psi5 psi Cost per column$400 and up$10 “A disposable, plug and play LC device.” “Easy to swap out chips for maintenance or to change the type of analysis.”

Microfabricated Liquid Analyzer Prototypes: Channels in PDMS We use microfabrication techniques such as soft lithography.

Separation Channel Sample By-pass Sample Inlet Mobile Phase Inlet Outlet Detection Region 100  m 10  m An integrated LC device: sampling, separation and detection Typical channel dimensions References P. G. Vahey, S.H. Park, B. J. Marquardt, Y. Xia, L. W. Burgess and R.E. Synovec Talanta, 2000, 51, P.G. Vahey, S. A. Smith, C. D. Costin, Y. Xia, A. Brodsky, L.W. Burgess and R. E. Synovec Analytical Chemistry, 2002, 74,

3 injections, 2 nL each Time, min Absorbance, mAU On-Chip Automation Provides Reproducible Injection 8 mM Bromocresol Green 5 mM phosphate mobile phase, pH 7, 40 nL / min PDMS channel 100  m x 10  m x 23 cm Valcor Solenoid Absorbance Detection Ocean Optics SD2000

Micro-fabricated LC with Absorbance Detection Separated temporally and spectrally Water m.p., 6 nL/min Injected Volume 1 nL Separation Channel in PDMS 100  m x 10  m x 6.6 cm Absorbance Detection using Equitech Spectrophotometer FD&C Red #3 FD&C Blue #1

Microfluidic Chip and Instrument Setup for  -MWS References C. D. Costin, R. E. Synovec, Talanta, 2002, 58, and Analytical Chemistry, 2002, 74,

 -MWS: Measure  -RIG Signals at Two Positions Real-Time, Dual-Beam Detection Configuration Sample Inlet Mobile Phase Inlet Outlet Laser Beams Upstream Downstream   Deflected Beams Position Sensitive Detectors (PSDs)

Upstream and Downstream  -MWS signals of PEG 106 and PEG  L off chip sample injection Signals were aligned in time Diffusion and MW information Upstream Downstream Signal (mrads) Time (Seconds) PEG 106 PEG 11840

Ratio of the Upstream and Downstream Position Signals for PEG 106 and PEG Independent of Concentration Time (Seconds) Ratio PEG 106PEG Ratio signal as a function of time is independent of concentration Diffusion and molar mass information

Molecular Weight Calibration for Linear Poly(ethylene)glycols (PEGs) Excellent Molar Mass Resolution!! Imagine application as on-line sensor of polymerization, etc. Ratio of downstream to upstream signals Ratio is independent of concentration Predict molar mass: calibration required for each class of compounds Tune range by flow rate and detection positions

Sugar Analysis using  -MWS 20  L off-chip sample injection at 1 ppth 3 injections for each sample Ratio Molar Mass (g/mol) Glycerol Deoxyribose Glucose Sucrose Lactose Raffinose Various sugars are readily distinguished on-chip, suitable for real-time analysis of bio-related processes

Process Monitoring with the  -MWS “Can readily monitor peptide or protein synthesis” Amino Acid and Peptide solutions for monitoring protein synthesis or digestion Quickly able to detect addition or subtraction of amino acids Ratio Molar Mass (g/mol) Gly Gly-Gln Gly-Gly-His Gly-Gly-Tyr-Arg

Bio-Fermentation Processes There is a need for reliable sampling and on-line LC

On-Line Monitoring of Bio-Fermentation, etc. Applying Micronics H – Filter for Sampling Sample From Fermentation Process Clean sample for Analysis by LC, etc… To Waste or Recycle Mobile Phase Quantitative (reproducible) Robust Simple Applies laminar flow fluidics with diffusion control.

Process Monitoring: Coupling LC on-a-chip and the  -MWS to Microreactors Aqueous and Non-aqueous Polymerizations, Bio-reactions, etc.

Glass Chip Applications Integrated chip- based LC and CE with  -MWS detection Process monitoring of organic reactions HPLC detector for aqueous and non-aqueous separations Glass Chip Prototype

Conclusions LC analyzers and NeSSI –Miniaturized analytics –On-line monitoring –Relatively fast cycle time –Demonstrated modularity –More informative process control –Decrease in maintenance costs More work needs to be done!