Short Arc Digital Tomosynthesis as an Image Enhancement Step for Detection and Localization of Implanted Markers Margie Hunt, Pengpeng Zhang Memorial Sloan-Kettering.

Slides:



Advertisements
Similar presentations
3D Model Matching with Viewpoint-Invariant Patches(VIP) Reporter :鄒嘉恆 Date : 10/06/2009.
Advertisements

Test Automation for Verifying Software’s Detectability for Rule Violations Name: Zhishuai Yao Supervisor: Pro. Jukka Manner Place: Varian Medical Systems.
RapidArc plan verification using ArcCHECK™
In the past few years the usage of conformal and IMRT treatments has been increasing rapidly. These treatments employ the use of tighter margins around.
A Novel Approach of Assisting the Visually Impaired to Navigate Path and Avoiding Obstacle-Collisions.
Mark Mirotznik, Ph.D. Associate Professor The University of Delaware
Historical Development
Do Now:.
11.5 Rotations. Rotations Rotate a Figure 90 about the origin.
A Spatially Adaptive Filter Reducing Arc Stripe Noise for Sector Scan Medical Ultrasound Imaging Qianren Xu Mohamed Kamel Magdy M. A. Salama.
Digital Image Forensics
Remote sensing in meteorology
The TrueBeam System ™ Clinic Name Presenter’s name Clinic location
CVPR 2008 June 24 – 26, 2008 Infrared camera:  Mid wave: microns  Resolution: 640*512 pixels with 14bits  Frame rate: 30/60/115 fps  Sensitivity:
CVPR 2006 New York City Granularity and Elasticity Adaptation in Visual Tracking Ming Yang, Ying Wu NEC Laboratories America Cupertino, CA 95014
Kirov A S, MSKCC Overview of Geant4 Use and Issues in Imaging: Emission Tomography (PET and SPECT) Assen S. Kirov Department of Medical Physics Memorial.
Tracking using the Kalman Filter. Point Tracking Estimate the location of a given point along a sequence of images. (x 0,y 0 ) (x n,y n )
Integrated Circuits Design for Applications in Communications Dr. Charles Surya Department of Electronic and Information Engineering DE636  6220
P. Rodríguez, R. Dosil, X. M. Pardo, V. Leborán Grupo de Visión Artificial Departamento de Electrónica e Computación Universidade de Santiago de Compostela.
tomos = slice, graphein = to write
Alf Öhman, investigator, Läkemedelsverket/ MPA Sweden Stefan Visscher, senior inspector Software Working Group, Brussels, February Dental software.
…….CT Physics - Continued V.G.WimalasenaPrincipal School of radiography.
Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator Andrew J Reilly Imaging Physicist Oncology Physics Edinburgh Cancer.
I mage is a visual representation of an object or scene or person produced on a surface. I mage is a visual representation of an object or scene or person.
Motion Object Segmentation, Recognition and Tracking Huiqiong Chen; Yun Zhang; Derek Rivait Faculty of Computer Science Dalhousie University.
I. Introduction Objectives  To solve geometric problem(misalignment) in cone-beam computed tomography (CBCT) system.  To adjust X-ray focal spot using.
Cancer Patients and IT Tools. IT has a great impact on health care. IT helps organize patients records and provides websites where patients and health.
Rotations EQ: How do you rotate a figure 90, 180 or 270 degrees around a given point?
Unit 5: Geometric Transformations.
Filtered Backprojection. Radon Transformation Radon transform in 2-D. Named after the Austrian mathematician Johann Radon RT is the integral transform.
HP-PURDUE-CONFIDENTIAL Final Exam May 16th 2008 Slide No.1 Outline Motivations Analytical Model of Skew Effect and its Compensation in Banding and MTF.
Aim Clinical indication Manufacturing scan prosthesis CT scan protocol Double scan registration wizard Double scan.
Linear Algebra THURSDAY, AUGUST 14. Learning Target I will understand what is meant by turn or rotational symmetry and how each point in a figure is related.
Dengsheng Zhang and Melissa Chen Yi Lim
21 June 2009Robust Feature Matching in 2.3μs1 Simon Taylor Edward Rosten Tom Drummond University of Cambridge.
Real Time Tomography Advanced Imaging Techniques
AdvisorStudent Dr. Jia Li Shaojun Liu Dept. of Computer Science and Engineering, Oakland University Automatic 3D Image Segmentation of Internal Lung Structures.
A B C D E F A ABSTRACT A novel, efficient, robust, feature-based algorithm is presented for intramodality and multimodality medical image registration.
Handwritten Signature Verification
© ACTS-MoMuSys All Rights Reserved. VOGUE The Video Object Generator with User Environment Ecole Nationale Supérieure des Mines de Paris, France.
Part No...., Module No....Lesson No
Face Detection Using Skin Color and Gabor Wavelet Representation Information and Communication Theory Group Faculty of Information Technology and System.
WELCOME TO ALL. DIGITAL IMAGE PROCESSING Processing of images which are Digital in nature by a Digital Computer.
Introduction to Radiation Therapy
Combined ultrasound-fluoroscopy approach to the intraoperative detection of seeds in prostate brachytherapy Vishruta A. Dumane, Marco Zaider, Gilad N.
Comparison of Image Registration Methods David Grimm Joseph Handfield Mahnaz Mohammadi Yushan Zhu March 18, 2004.
Glossary of Technical Terms Correlation filter: a set of carefully designed correlation templates with regard to shift invariance as well as distortion-
Recovering Shape from Boundaries Sheng Xu 3/2/01.
Three-dimensional Dose Verification Using Normoxic Polymer Gel Dosimeters for Tomotherapy Tung-Hsin Wu 1, Chien-Yi Hsiao 2, Mu-Bai Chang 2, Geoffrey Zhang.
A Partner for life By Jill Corbett. “Varian Medical Systems’ mission is to focus energy on saving lives. Our goal is to help save millions of lives around.
IRIS RECOGNITION 1 CITY ENGINEERING COLLEGE Technical Seminar On “IRIS RECOGNITION” By NANDAN.T.MURTHY 1CE06EC043.
Tomography for Intraoperative Evaluation of Breast Tumor Margins:
Signal and Image Processing Lab
You Zhang, Jeffrey Meyer, Joubin Nasehi Tehrani, Jing Wang
Kasey Etreni BSc., MRT(T), RTT, CTIC
Date of download: 10/16/2017 Copyright © ASME. All rights reserved.
Acoustic mapping technology
The use of 4DCT images to optimize the Internal Target Volume in Radiotherapy  Nikos Giakoumakis, Brian Winey, Joseph Killoran, Tania Lingos, Laurence.
Neuro Best Contrast Filter for Head CT
An Investigation of the Effect of Window and Level Controls on the accuracy of the ExacTrac Patient Repositioning System Dan Goldbaum and Russell Hamilton.
Synthesis of X-ray Projections via Deep Learning
Implementation of Object Spot Avoidance in Proton Pencil Beam Treatment on Whole Breast with Implant Metal Injector Peng Wang, PhD, DABR, Karla Leach,
Insert tables Insert figure
Visualization and Detection of Prostatic Carcinoma
Goals Significance Results Uncorrected MAR Corrected
Practical Assessment of Bronchoscopically Inserted Fiducial Markers for Image Guidance in Stereotactic Lung Radiotherapy  Price Jackson, PhD, Daniel P.
Visualization and Detection of Prostatic Carcinoma
Remote sensing in meteorology
GHG meeting at ESTRO36 May, 2017
Presentation transcript:

Short Arc Digital Tomosynthesis as an Image Enhancement Step for Detection and Localization of Implanted Markers Margie Hunt, Pengpeng Zhang Memorial Sloan-Kettering Cancer Center, New York NY Hassan Mostafavi, Alexander Sloutsky, Andrew Jeung Varian Medical Systems Inc., Palo Alto CA

Automatic detection of implanted radio-opaque markers can be challenging due to noise, scatter, and obfuscating structures Image enhancement by Short Arc Digital Tomosynthesis (DTS) – tomosynthesis reconstruction over a 3 – 5° arc – may enhance images to aid detection Enhancement can be quantified by matching to an image template and calculating the peak-to-sidelobe ratio (PSR) of the resulting match surface Study Objectives

Image Enhancement using Short Arc DTS  Example scenario: Gantry rotation during treatment e.g. RapidArc  Use MV projections over last θ degrees to reconstruct a DTS image  Targets that would otherwise be obscured by scatter noise and overlaying structures will be enhanced sufficiently for successful automatic tracking

Results Comparison of original MV images (left) to DTS-enhanced images (right). DTS- enhanced markers are easier to identify, and band artifacts due to linac are eliminated. a b PSR = c PSR = Template of markers generated from plan CT (a) matches with the DTS-enhanced image (c) with a higher PSR score than with the original MV projection (b).

Gantry Angle PSR: Template to original image PSR: Template to DTS- enhanced image 21.3° ° ° DTS enhancement results in a consistently higher peak-to-sidelobe ratio (PSR)

Conclusions Short Arc DTS can enhance image sequences acquired during gantry rotation It shows promise in making detection and localization of markers more robust and accurate Template matching and use of peak-to-sidelobe ratio can quantify the improvement in detectability