A Brief Journey into Parallel Transmit Jason Su. Description Goal: expose myself to some of the basic techniques of pTx –Replicate in-class results –Explore.

Slides:



Advertisements
Similar presentations
DCSP-13 Jianfeng Feng Department of Computer Science Warwick Univ., UK
Advertisements

UWB Channels – Capacity and Signaling Department 1, Cluster 4 Meeting Vienna, 1 April 2005 Erdal Arıkan Bilkent University.
Pulse Techniques. Off-Resonance Effects Initial magnetization along z x-pulse (  = 0) On-resonance: M z -> -M y Off-resonance: phase 
Statistical Parametric Mapping
Figure 2. Signal level (left) degrades with slice offset and slice thickness when Z2 SEM is used in GradLoc imaging (ROI = FOV/2). To recover the full.
Parameters and Trade-offs
Topics spatial encoding - part 2. Slice Selection  z y x 0 imaging plane    z gradient.
Principles of MRI: Image Formation
Basics of fMRI Preprocessing Douglas N. Greve
Chapter 9 Basic MRI I Mark D. Herbst, MD, PhD. Notice This lecture contained many drawings on the whiteboard, so get these from one of the other students.
Magnetic Resonance Imaging
Let’s go back to this problem: We take N samples of a sinusoid (or a complex exponential) and we want to estimate its amplitude and frequency by the FFT.
Digital Signal Processing
Wald, fMRI MR Physics Massachusetts General Hospital Athinoula A. Martinos Center MR physics and safety for fMRI Lawrence L. Wald, Ph.D.
More MR Fingerprinting
Terry M. Button, Ph.D. Principals of Magnetic Resonance Image Formation.
MRI. Magnetic Resonance 1.Principle first observed in Used for spectroscopy and imaging 3.Imaging techniques are a form of tomography, where slices.
Psy 8960, Fall ‘06 EPI, Part 11 Pulse sequences Nyquist ghost Chemical shift –FLASH –EPI.
Chapter 10 Lecture Mark D. Herbst, M.D., Ph.D..
Folie 1 Ambiguity Suppression by Azimuth Phase Coding in Multichannel SAR Systems DLR - Institut für Hochfrequenztechnik und Radarsysteme F. Bordoni, M.
Real-Time MRI – Outline Biomed NMR JF11/59 Technical Considerations - Data Acquisition - Image Reconstruction Preliminary Applications - Joint Movements,
Folie 1 Performance Investigation on the High-Resolution Wide-Swath SAR System Operating in Stripmap Quad-Pol and Ultra-Wide ScanSAR Mode DLR - Institut.
Modulations. Modulation to tie information to the carrier frequency Carrier frequency: the RF signal which is modulated by the baseband signal Two main.
Basics of Magnetic Resonance Imaging
Markus Strohmeier Sparse MRI: The Application of
Psy 8960, Fall ‘06 Fourier transforms1 –1D: square wave –2D: k x and k y Spatial encoding with gradients Common artifacts Phase map of pineapple slice.
Psy 8960, Fall ‘06 Gradients and Fields1 Gradients and fields Static magnetic field Gradients –Effect of simultaneous gradients Excitation and slice selection.
FMRI: Biological Basis and Experiment Design Lecture 7: Gradients and k-space FFT examples –Sampling and aliasing Gradient Gradient echo K-space
FMRI: Biological Basis and Experiment Design Lecture 8: Pulse sequences, Take 2 Gradient echo review K-space review Slice selection K-space navigation.
Radiofrequency Pulse Shapes and Functions
MRI Image Formation Karla Miller FMRIB Physics Group.
Principles of MRI Physics and Engineering
Imaging Sequences part II
Gradients (Continued), Signal Acquisition and K-Space Sampling
HOW TO OPTIMIZE MRI OF EXTREMITIES ?
Susceptibility Induced Loss of Signal: Comparing PET and fMRI on a Semantic Task Devlin et al. (in press)
Ping Zhang, Zhen Li,Jianmin Zhou, Quan Chen, Bangsen Tian
EE369C Final Project: Accelerated Flip Angle Sequences Jan 9, 2012 Jason Su.
1 CS6825: Digital images How are DIGITAL images created. How are DIGITAL images created. Previous lecture we discussed how ANALOG images are created Previous.
G Practical MRI 1 Gradients.
Allen W. Song, PhD Brain Imaging and Analysis Center Duke University MRI: Image Formation.
Calculation of Beam loss on foil septa C. Pai Brookhaven National Laboratory Collider-Accelerator Department
Brit and the Rad Lab at MIT Radiation Laboratory Series: Documented developments from the Rad Lab Volume 19 (copyright 1949): Waveforms- edited by B. Chance.
GPU Accelerated MRI Reconstruction Professor Kevin Skadron Computer Science, School of Engineering and Applied Science University of Virginia, Charlottesville,
Microphone Array Project ECE5525 – Speech Processing Robert Villmow 12/11/03.
COMMUNICATION SYSTEM EEEB453 Chapter 5 (Part IV Additional) DIGITAL TRANSMISSION.
Trajectory Generation
Anna Beaumont FRCR Part I Physics
MR Image Formation FMRI Graduate Course (NBIO 381, PSY 362)
Single Correlator Based UWB Receiver Implementation through Channel Shortening Equalizer By Syed Imtiaz Husain and Jinho Choi School of Electrical Engineering.
Magnetic Resonance Learning Objectives
In vivo MRI of Fast Relaxing Spins Using a Swept Radiofrequency Djaudat Idiyatullin, Curt Corum, Jang-Yeon Park, Michael Garwood Center for Magnetic Resonance.
Principles of MRI Physics and Engineering Allen W. Song Brain Imaging and Analysis Center Duke University.
Beam Diagnostics Seminar, Nov.05, 2009 Das Tune-Meßverfahren für das neue POSI am SIS-18 U. Rauch GSI - Strahldiagnose.
LFM Pulse Compression Sidelobe Reduction Techniques
Lifecycle from Sound to Digital to Sound. Characteristics of Sound Amplitude Wavelength (w) Frequency ( ) Timbre Hearing: [20Hz – 20KHz] Speech: [200Hz.
EEE4176 Applications of Digital Signal Processing
FMRI data acquisition.
Fang Liu and Arthur Weglein Houston, Texas May 12th, 2006
Stencil-based Discrete Gradient Transform Using
C. Rogers, ASTeC Intense Beams Group Rutherford Appleton Laboratory
New Simrad sonar SX90 Low frequency sonar
Samy Abo Seada, Joseph V Hajnal and Shaihan J Malik
Sunday Case of the Day Physics
Questions from industry to GARCA A
SuperB LNF meeting March 21st 2012 Marcello Piccolo
Spatial Encoding: Sub mm from meter sized RF
An Optimal Design Method for MRI Teardrop Gradient Waveforms
Microphone Array Project
APPLICATION of the DFT: Estimation of Frequency Spectrum
Presentation transcript:

A Brief Journey into Parallel Transmit Jason Su

Description Goal: expose myself to some of the basic techniques of pTx –Replicate in-class results –Explore some possibilities –Learn about spokes design – 3D design Implement “inversion” design, as detailed in class notes

Small Tip-Angle Inversion Design Freedoms in design: –Number of spatial points –Number of k-space points Regularization and smoothing –Traditional design is sometimes too fast for RF coil to keep up

Basic Design Jinc-weighted spiral design as in HW3 –Resolution = 0.2cm –FOV = 10cm –Gradient amplitude max = 6 G/cm –Gradient slew rate max = 20 G/cm/ms –Desired slice width = 4cm Pulse length = 18ms for full FOV, 9ms for FOV/2

Spiral Design

Spiral Design – FOV/2

Parallel Transmit System 4 channels 16cm 24cm

Parallel Transmit Design Design target profile –Based on full FOV spiral –Cut out sidelobes –Flattened profile –2x accelerated –This is actually infeasible 64x64 spatial points, 512 spiral k-space points

Result Good sidelobe cancellation Uniformity of mainlobe is poor

Finer K-Space Sampling We can improve the design by depositing more energy into k-space over the same trajectory –i.e. sample more finely in k-space –The penalty is that we need a better RF coil to keep up with the sampling rate

Finer K-Space Sampling

Side Note: Receive Oversampling The excited profile is calculated as: E f b f The spatial resolution of E f can be as fine as desired Sample an 80x80 grid: The profile is quite different. Matching with Tx required?

RF Coil Considerations RF coils have finite bandwidth With hardest case of 2048 k-space pts., how does this affect excited volume?

Effects of RF Coil Modeled coil response as that of a windowed sinc Somewhat arbitrarily: BW half the k-space sampling rate = 100KHz

Resulting Profile Poor cancellation outside main lobe Main lobe profile is worsened Sidelobes reappear at edges Should be able to do better, consider 1024-sample

Smoothing w/ Regularization Try to minimize the high frequency energy –J = ||Eb-M||^2 + μ||Fb||^2, where F is the DFT matrix for high frequencies Changed to 32x32, 512-sample due to memory limitations

Comparison

Conclusion Here, there is a knee in the RMSE vs. # k- space pts. profile at around 1024 pts., may not be always be the case RF coil bandwidth greatly affects the quality of the resulting excitation profile Regularization improves profile, especially out-of-mainlobe uniformity