What are the dose quantities in CT ? IAEA/RCA Kampala Kampala.

Slides:



Advertisements
Similar presentations
Radiation safety in CT.
Advertisements

Chapter 4 Radiation Dosimeters
Image Reconstruction.
Radiation safety in CT.
CT Organ Dose - Part 1 Estimating organ dose for patients Michael F. McNitt-Gray, Ph.D., DABR David Geffen School of Medicine at UCLA.
European Diagnostic Reference Levels in Paediatric Imaging
State of Michigan Computed Tomography Regulations
Radiation Safety Chapter 9 Bushong.
Michael F. McNitt-Gray, PhD, DABR, FAAPM Professor, Department of Radiology, David Geffen School of Medicine at UCLA Kevin O’Donnell Toshiba Medical Research.
Computed Tomography Basic principles V.G.Wimalasena Principal
Advanced Biomedical Imaging Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University Lecture 6 Basic physical principles of.
X-ray diagnostics and Computed tomography. 15th century head examination.
Computed Tomography II
Seeram Chapter 13: Single Slice Spiral - Helical CT
RAD309 Patient Dose.
NC HPS Meeting 10/18-19/2001 Boone, NC Recent Advances in CT Technology and Issues of CT Dosimetry T. Yoshizumi 1,2, M. Sarder 1, R. Reiman 1,2, E. Paulson.
1 NEXT 2000: Survey of Computed Tomography (CT) Practice, Workload, Dose Stanley H. Stern, Ph. D. FDA/CDRH Office of Health and Industry Programs Division.
1 Physics Testing for Performance Based Protocol version 3.0 (Now based on ACRIN 6678) QIBA Group 1C.
5 th September 2005 Paul Collins Computed Tomography Dosimetry Assessment of Effective Dose in Computed Tomography using an Anthropomorphic Phantom Paul.
David E. Hintenlang, Ph.D., DABR
XI. National Turkish Medical Physics Congress
At the position d max of maximum energy loss of radiation, the number of secondary ionizations products peaks which in turn maximizes the dose at that.
Conventional and Computed Tomography
Kalpana Kanal, Ph.D., DABR Associate Professor, Diagnostic Physics
COMPUTED TOMOGRAPHY I – RAD 365 CT - Scan
Quality Control Rad T 110.
Dose Distribution and Scatter Analysis
CT Quality Control for CT Scanners. Quality Control in CT A good idea? Yes Required for accreditation? Sometimes Improves image quality? Sometimes Depends.
TWO FIELD BREAST PLAN VS. OPTIMIZED CONFORMAL BREAST PLAN: COMPARISON OF PLAN PARAMETERS Authors: Borko Basarić, Ozren Čudić, Milan Teodorović, Borislava.
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Dose Survey in Computed Tomography DS /CM Kampala IAEA/RCA Kampala.
Radiation Dosimetry of the Patient
Radiation Protection of Patients Unit
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 19.03: Optimization of protection in Mammography.
Radiographic Dosimetry
IAEA International Atomic Energy Agency Dental Radiology Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 2(2)
CT physics and instrumentation
Low Dose Head Computed Tomography Protocol for Evaluation of Non-traumatic Emergencies in Children Rishi Mhapsekar, MD Marilyn J. Siegel, MD Robert McKinstry.
George David Associate Professor of Radiology Medical College of Georgia.
Reduction of effective and organ dose to the eye lens in cerebral MDCT scans using iterative image reconstruction Zizka J, Jandura J, Kvasnicka T, Klzo.
PRINCIPLES OF CT Dr Mohamed El Safwany, MD. Intended learning outcome The student should learn at the end of this lecture principles of CT.
CT Instrumentation and X-ray system
IAEA International Atomic Energy Agency Optimization of Protection in Computed Tomography (CT)-What can radiographers do? IAEA Regional Training Course.
QIBA CT Volumetrics - Cross-Platform Study (Group 1C) March 18, 2009 Interclinic Comparison of CT Volumetry Quantitative Imaging Biomarker Alliance.
How we set a DRL An example using CT David Sutton / Colin Martin Kampala IAEA/RCA Kampala.
Understanding radiation units L02
Advanced CT systems and Their Performance
Part No...., Module No....Lesson No
Greetings from Philadelphia! Independance Hall. Quality Assurance of CT Simulator in Modern Radiation Therapy* Andrew Wu, PhD, FAAPM Department of Radiologic.
RADIATION DOSE ISSUES.
Computed Tomography Computed Tomography is the most significant development in radiology in the past 40 years. MRI and Ultrasound are also significant.
Computed tomography. Formation of a CT image Data acquisitionImage reconstruction Image display, manipulation Storage, communication And recording.
Assessment of radiation exposure on a dual-source computed tomography-scanner performing coronary computed tomography-angiography  S. Kirchhoff, P. Herzog,
An exercise in how to assess the CTDIw , DLP and effective dose
CT Multi-Slice CT.
Computed Tomography Basic principles Tamer M. Nassef.
Head computed tomography doses in four selected hospitals in Nigeria
Patient exposure trends and problems in implementing ALARA
How we set a DRL An example using CT
Electron Beam Therapy.
CT PRINCIPLES AYMAN OSAMA.
Dr: Mohamed Afifi By Lecturer Radiological Science
Figure 1. (a) A set-up used for the measurements showing the head phantom and the ion chamber located in the central hole. The cylindrical phantom has.
Sample General Electric CT Dose Report from a CT of the chest, abdomen, and pelvis. The dose report contains information about the patient (deleted), type.
David Sutton or Colin Martin But Borrowed from Jerry Williams
Exhibit Number: C19 Evaluation and Reduction of Head Computed Tomography Dose Because of full frame graphic use title slide sparingly because too many.
Chapter 22: Patient Dosimetry
Ch 10. A System of Dosimetric Calculations
David J. Brenner, Maria A. Georgsson  Gastroenterology 
Hp(10) irradiations for personal dosimetry traceability
Presentation transcript:

What are the dose quantities in CT ? IAEA/RCA Kampala Kampala

CT Principles Kampala

Reminder : CT terminology Axial scanning –1 rotation of beam followed by stepwise couch movement –Increment – distance moved by couch Helical/spiral scanning –Continuous table movement & beam rotation –Pitch – table movement relative to nominal slice width Kampala

CT Slice Kampala

CT Slice Kampala

CT Slice Kampala

Dose Profile Kampala

Dose profile for a series of slices Kampala

Dose Profiles in Phantoms / Patients Effects of scatter Broadened profile Peak kerma dependent on beam width Long scatter tails for wide beams Kampala

Which Dosemeter ? Kampala

Integrated Profile Kampala

Integrated Profile Kampala

CTDose Index Measure of dose for a single axial slice (mGy) –no account of Helical/MDCT gaps or overlaps CTDI = area under dose profile (mGy.mm) nominal slice width, T (mm) Kampala kerm a T CTDI (mGy) Z-axis (mm) CTDI = height of rectangle if area under profile was all contained within nominal slice width

CTDI 100 – What is it ? Analagous to Multiple Scan Average Dose. Originally defined for single slice scanners. Kampala

In air : CTDI 100,Air Sometimes normalise to 1 mAs: n CTDI 100,Air Just like in radiography! Kampala

In Perspex / PMMA Kampala

CT dosimetry in Perspex The computed tomography air kerma index is also measured inside PMMA head and body phantoms The quantity CTDI 100,c is measured at the centre of the standard CT dosimetry phantom and CTDI 100,p is the average of values measured at four positions around the periphery of the same phantom. Kampala

CTDI 100 CTDI can be measured in air or in phantoms CTDI in air can be used as a measure of tube output For dosimetry purposes CTDI is measured in perspex phantoms 16cm diameter ‘head’ 32cm diameter ‘body’ Kampala

Patient Size. CTDI is a measure of scanner output. CTDI does take patient size into account CTDI is NOT patient dose Important for paediatrics, small adults and possibly bariatrics. You can correct to patient size –To be mentioned later. Kampala

Phantoms for CT dosimetry Cylindrical PMMA phantoms with holes for pencil chamber 32 cm body phantom 16 cm head phantom Kampala

Centre Periphery – 1cm depth (mean of 4 positions) C P1P1 P2P2 P3P3 P4P4 32 cm ‘Head’ ‘Body’ 16 cm 140 mm CTDI Phantoms Kampala

40 ‘Head’ ‘Body’ Periphery : centre  1:1 Periphery : centre  2:1 Typical CTDI 100 Values CTDI 100,p values quoted in mGy Kampala

CTDI W Weighted average CTDI: represents the average dose for contiguous irradiation CTDI w = 1/3 CTDI centre + 2/3 CTDI periphery n CTDI w = CTDI w /mAs CTDI C CTDI P Kampala

CTDI vol Pitch = 1 CTDI vol = CTDI w Pitch = 2 CTDI vol = CTDI w 2 Pitch = 0.5 CTDI vol = 2 x CTDI w Kampala

CTDI vol CTDI W is the average dose in the scan plane Volume CTDI considers non-contiguous scanning The CTDI vol can be considered to be the average CTDI W in the scan volume CTDI vol = CTDI W Pitch Kampala

Dose Length Product CTDI vol is a measure of absorbed dose, energy absorbed per unit mass Radiation risk is based on total energy absorbed Estimate using dose length product (DLP) DLP = CTDI vol x scan length Units are mGy cm Kampala

Dose Quantities in CT Kampala

Dose Summary Sheet - Commercial CT Scanner Huda W, Mettler F A Radiology 2011;258: Kampala

CTDI on the Console The CTDI value displayed will depend on the phantom that it is based on. Body : 32 cm; Head 16 cm. CTDI for 16cm reference twice that of CTDI for 32cm reference. Paediatric protocol MAY reference to 16 cm phantom Implementation manufacturer dependent. Kampala

CTDI MEASUREMENT IN PRACTICE Kampala

Equipment for CT measurements CT ionization chamber and electrometer calibrated for CT beam qualities Chamber support stand CT head & body phantoms Kampala

Methodology for CT measurements in air Position chamber in stand so beyond couch Adjust couch position so chamber along axis of scanner and beam centred at central point of chamber Record dose measurements for single axial scan at selected parameters (no couch movement) Record all data Kampala

Methodology for CT measurements in phantoms Position phantom on couch (use head rest if appropriate) Position chamber in central position in phantom Adjust couch position so chamber centred as before Record dose measurements for single axial scan at selected parameters (no couch movement) Repeat for peripheral positions (north, south, east & west) Kampala