LWC C ALIBRATION The Long Wavelength Channel calibration procedure is currently on its version 4The Long Wavelength Channel calibration procedure is currently.

Slides:



Advertisements
Similar presentations
AITA 9, MERTIS Team – MERTIS Calibration, Oct 2007 Folie 1 Development of a calibration concept for the MErcury Thermal Infrared Spectrometer Thomas Saeuberlich,
Advertisements

Algorithm improvements for Dutch OMI NO2 retrievals (towards v3.0)
Retracking & SSB Splinter OSTST ‘07 Retracking and SSB Splinter Report Juliette Lambin and Phil Callahan March 14, 2007 Hobart, Tasmania.
1 st post launch SCIAMACHY calibration & Verification Meeting L1b Astrium Friedrichshafen – Germany 24 July 2002 First Level 1b Spectral Calibration analysis.
SABER Instrument Performance and Measurement Requirements.
ECFA-DESY workshop, NIKEF 1 st April, 2003Nick Walker, DESY Energy Spread Measurement in the TESLA Extraction Line Nick Walker - DESY.
Distance observations
Determination of Emissivity by Using Reflected Thermal Radiation Frank Liebmann.
Effects of External Magnetic Fields on the operation of an RF Cavity D. Stratakis, J. C. Gallardo, and R. B. Palmer Brookhaven National Laboratory 1 RF.
Lecture 4 Measurement Accuracy and Statistical Variation.
KNMI, The Netherlands * SCIAMACHY validation workshop, Bremen, 6 Dec ‘04 Large scale validation of SCIAMACHY nadir reflectance Gijs van.
Observational Simulations in Support of CLARREO Development Collins Group Meeting October 10, 2008.
ESTEC July 2000 Estimation of Aerosol Properties from CHRIS-PROBA Data Jeff Settle Environmental Systems Science Centre University of Reading.
S TUDIES OF THE M ARTIAN A TMOSPHERE WITH PFS : T HERMAL P ROFILES M. Giuranna * * Istituto di Fisica dello Spazio Interplanetario.
Rachel Klima (on behalf of the MASCS team) JHU/APL MASCS/VIRS Data Users’ Workshop LPSC 2014, The Woodlands, TX March 17,2014 MASCS Instrument & VIRS Calibration.
Sz. Rózsa: Surveying I. – Lecture 1
Method Comparison A method comparison is done when: A lab is considering performing an assay they have not performed previously or Performing an assay.
CEMTREX, INC. MODCON SYSTEMS LTD NIR Systems July 2010.
Thermal evolution of flares observed by PROBA2/LYRA I. E. Dammasch, M. Dominique, M. Kretzschmar (ROB/SIDC), P. C. Chamberlin (NASA/GSFC) COSPAR 39 th.
Plans for interim data release J E Russell (Imperial)
GEWEX/GlobVapour Workshop, Mar 8-10, 2011, ESRIN, Frascati, Italy WATER VAPOUR RAMAN LIDARS IN THE UTLS: Where Are We Now? or “The JPL-Table Mountain Experience”
COST 723 Training School - Cargese October 2005 OBS 2 Radiative transfer for thermal radiation. Observations Bruno Carli.
Blue: Histogram of normalised deviation from “true” value; Red: Gaussian fit to histogram Presented at ESA Hyperspectral Workshop 2010, March 16-19, Frascati,
Norm Nelson, UCSB Chantal Swan, UCSB / ETH with assistance of: Julia Gauglitz, Teresa Serrano Catala, Erica Aguilera UltraPath in the Oligotrophic Ocean.
Intercomparison cancelled! Pete Burgess. Why? We were going to run another contam monitor testing intercomparison. But we’re not. The last intercomparison.
What is an error? An error is a mistake of some kind... …causing an error in your results… …so the result is not accurate.
 a mathematical procedure developed by a French mathematician by the name of Fourier  converts complex waveforms into a combination of sine waves, which.
MS Calibration for Protein Profiles We need calibration for –Accurate mass value Mass error: (Measured Mass – Theoretical Mass) X 10 6 ppm Theoretical.
1 Leonardo Pinheiro da Silva Corot-Brazil Workshop – October 31, 2004 Corot Instrument Characterization based on in-flight collected data Leonardo Pinheiro.
Jörn Helbert Planetary Emissivity Laboratory Facing the heat – Obtaining near infrared real emissivity spectra at Venus surface temperatures.
1-D Flat Fields for COS G130M and G160M Tom Ake TIPS 17 June 2010.
Statistical Process Control04/03/961 What is Variation? Less Variation = Higher Quality.
Hwk Ans Key. Experimental Errors & Uncertainty.
INTRODUCTION TO ENGINEERING TECHNOLOGY SEVENTH EDITION ROBERT J. POND & JEFFERY L. RANKINEN Chapter 7 The Technical Laboratory.
Warm-up: Are these “errors”? 1. Misreading the scale on a triple-beam balance 2. Incorrectly transferring data from your rough data table to the final,
Errors and Uncertainties In Measurements and in Calculations.
A Method for Correcting for Telescope Spectral Transmission in the Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) John D. Elwell, Deron.
Analysis of Nonlinearity Correction for CrIS SDR April 25, 2012 Chunming Wang NGAS Comparisons Between V32 and V33 Engineering Packets.
Russian Aviation and Space Agency Institute for Space Research NASA 2001 Mars Odyssey page 1 Workshop HEND Procedures of HEND data convolution for.
MODIS Preprocessing (before L1B) Changes over the Last Year (and looking forward) Chris Moeller and others CIMSS; Univ. Wisconsin July 13, 2004 Thanks.
Validation of OMPS-LP Radiances P. K. Bhartia, Leslie Moy, Zhong Chen, Steve Taylor NASA Goddard Space Flight Center Greenbelt, Maryland, USA.
1 st post launch SCIAMACHY calibration & Verification Meeting L1b Astrium Friedrichshafen – Germany 24 July 2002 First level 1b Leakage current analysis.
Experimental Errors and Uncertainties
Think back to our experiment's data, who had systematic error(s)?
Rutherford Appleton Laboratory Requirements Consolidation of the Near-Infrared Channel of the GMES-Sentinel-5 UVNS Instrument: Initial trade-off: Height-resolved.
Increased Thermal Background for the post-NCS NICMOS TIPS – June 19, 2003 Megan Sosey NICMOS.
Universitat Politècnica de Catalunya CORRECTION OF SPATIAL ERRORS IN SMOS BRIGHTNESS TEMPERATURE IMAGES L. Wu, I. Corbella, F. Torres, N. Duffo, M. Martín-Neira.
DATA PROCESSING & ANALYSIS. DATA ANALYSIS ADDITIONAL DATA PROCESSING Dark Corrections Interpolate to bins of wavelengths Quality Control (tilting corrections,
MEx and VEx DATA WORKSHOP - PFS and SOIR experiments - 27 June - 1st July 2011, ESA/ESAC,Spain.
Radiometric Calibration of the ASTER Thermal Infrared (TIR) Subsystem Simon J. Hook NASA/JPL.
Methane Retrievals in the Thermal Infrared from IASI AGU Fall Meeting, 14 th -18 th December, San Francisco, USA. Diane.
SORCE - Spectral Irradiance Monitor Stéphane Béland 1, J. Harder 1, M. Snow 1, G. Thuillier 2 1 LASP – University of Colorado Boulder 2 LATMOS-CNRS SOSLPEC.
UNIT 2 – MODULE 5: Multispectral, Thermal & Hyperspectral Sensing
Digital Imaging and Remote Sensing Laboratory thermal infrared data 1 Processing of TIMS data to emissivity spectra TIMS bands for this analysis 8.407,
Rutherford Appleton Laboratory Requirements Consolidation of the Near-Infrared Channel of the GMES-Sentinel-5 UVNS Instrument: FP, 25 April 2014, ESTEC.
A. Ealet Berkeley, december Spectrograph calibration Determination of specifications Calibration strategy Note in
Pre-launch Characteristics and Calibration
Miscellaneous Measurements
VIRTIS flyby of Steins M-IR Spectral analysis
COS FUV Flat Fields and Signal-to-Noise Characteristics
DATA PROCESSING & ANALYSIS
Instrument Characterization: Status
SOIR operations and archiving
GIFTS System Calibration Requirements Flowdown
Errors and Uncertainties
Dorothee Coppens.
Uncertainty and Error
Early calibration results of FY-4A/GIIRS during in-orbit testing
MIPAS-2D water database and its validation
Presentation transcript:

LWC C ALIBRATION The Long Wavelength Channel calibration procedure is currently on its version 4The Long Wavelength Channel calibration procedure is currently on its version 4 It is the result of an extensive study of the thermal/statistical behavior of PFSIt is the result of an extensive study of the thermal/statistical behavior of PFS This procedure has been extensively validated and is currently providing good results ( H 2 O, temperature vertical profiles, ice/dust/clouds studies, surface temperature maps )This procedure has been extensively validated and is currently providing good results ( H 2 O, temperature vertical profiles, ice/dust/clouds studies, surface temperature maps ) Provided curves can be used at thermal regime condition (> 90% of data) Provided curves can be used at thermal regime condition (> 90% of data) Interpolation is required for non-regime conditions Interpolation is required for non-regime conditions Residual issues may occur (tilts and wiggles, phase). See Giuranna this afternoon.Residual issues may occur (tilts and wiggles, phase). See Giuranna this afternoon. MEx and VEx DATA WORKSHOP - PFS and SOIR experiments - 27 June - 1st July 2011, ESA/ESAC,Spain

LWC calibrations V1 had some Zero-Level problems These problems have been solved with Calibration procedure V2 C ALIBRATION H ISTORY (1/2) MEx and VEx DATA WORKSHOP - PFS and SOIR experiments - 27 June - 1st July 2011, ESA/ESAC,Spain

Minor differences between V2 and V3 (better spectral calibration; new geometries)Minor differences between V2 and V3 (better spectral calibration; new geometries) Instrumental artifacts still present in V3, expecially above 800 cm -1Instrumental artifacts still present in V3, expecially above 800 cm -1 C ALIBRATION H ISTORY (2/2) Orbit 100 average of 200 spectra Fixed with Calib_v4 MEx and VEx DATA WORKSHOP - PFS and SOIR experiments - 27 June - 1st July 2011, ESA/ESAC,Spain

T HERMAL / S TATISTICAL A NALYSIS An extensive study of the thermal behavior of the instrument has been done (2006)An extensive study of the thermal behavior of the instrument has been done (2006) A set of 5360 averages of “Deep Space” and “Internal Black-Body” measurements has been collected, monitoring T D, T BB and T IB.A set of 5360 averages of “Deep Space” and “Internal Black-Body” measurements has been collected, monitoring T D, T BB and T IB. The main "expected" results are: 1)As already found in laboratory, the instrumental thermal emission is mainly controlled by the detector temperature; 2)as a consequence of point 1), the measured signal depends on the detector temperature; 3)This dependence on the detector temperature is linear and, knowing the detector temperature, we have the instrumental thermal emission by interpolation; This study also shows some other interesting results: a)The mechanical vibrations affect also the LW channel spectra; b.they cause systematic statistical errors in the measured signal of the same order of magnitude of the variations due to the detector temperature changes. In other words, even at thermal regime conditions ( T D ~287.0 K), a stable source (i.e. DS) shows variations of ~ 5-7% of the signal; c.Interesting enough, this systematic statistical errors have a ZERO- AVERAGE VALUE: averaging independent sets of Deep-Space spectra (at a given detector temperature) we get identical averages. FWD REV MEx and VEx DATA WORKSHOP - PFS and SOIR experiments - 27 June - 1st July 2011, ESA/ESAC,Spain

More than 90% of the Martian data and 99% of the Deep-Space measurements are acquired with the detector temperature well stable at ~287.0 K; consequently, thanks to point c), averaging all the DS measurements we have a very accurate estimate of the thermal emission of the instrument at thermal regime condition (i.e. for than 90% of the data) -> better radiometric calibration;More than 90% of the Martian data and 99% of the Deep-Space measurements are acquired with the detector temperature well stable at ~287.0 K; consequently, thanks to point c), averaging all the DS measurements we have a very accurate estimate of the thermal emission of the instrument at thermal regime condition (i.e. for than 90% of the data) -> better radiometric calibration; Thanks to point 3), we have a very accurate estimate of the thermal emission of the instrument also for non-regime conditions -> better radiometric calibration;Thanks to point 3), we have a very accurate estimate of the thermal emission of the instrument also for non-regime conditions -> better radiometric calibration; we don't need to use the calibration measurements within each session to have the instrumental thermal emission and responsivity. ALL orbits can now be calibrated!we don't need to use the calibration measurements within each session to have the instrumental thermal emission and responsivity. ALL orbits can now be calibrated! The residuals (artifacts, slopes etc...) sometimes present in the LWC spectra, will be reduced but will STILL be present, since they are NOT ONLY due to changes in the thermal conditions of the instrument, but also to the external mechanical vibrations and the two effects are of the same order of magnitude.The residuals (artifacts, slopes etc...) sometimes present in the LWC spectra, will be reduced but will STILL be present, since they are NOT ONLY due to changes in the thermal conditions of the instrument, but also to the external mechanical vibrations and the two effects are of the same order of magnitude. C ALIB_ V4 From the previous analysis follows that: MEx and VEx DATA WORKSHOP - PFS and SOIR experiments - 27 June - 1st July 2011, ESA/ESAC,Spain