Pressure Cure Oven (PCO)

Slides:



Advertisements
Similar presentations
Engineer Training XL1200 Drying System. Engineer Training XL1200 Drying System Confidential 2 XL1200 Drying System.
Advertisements

Using Heat Chapter 16.3.
Customer Service – International dept. STAR 24 3 E.
1 Ann Van Lysebetten CO 2 cooling experience in the LHCb Vertex Locator Vertex 2007 Lake Placid 24/09/2007.
Electronics Cooling MPE 635
Mini 24 Presents the new. Wall-hung boiler Self diagnostic system Electronic thermometer Furnace type: open Output power: 22,66 kW Min. 6,7 kW Stars of.
Heating, Ventilating, and Air-Conditioning
IX. REDUCING GREENHOUSE TEMPERATURE A. temperature regimes –range deg, stress above 90 deg.
What is Membrane Pressing? Membrane pressing is a laminating process using heat, pressure, vacuum and adhesive to apply vinyl film or thermoplastic sheet.
Using Copper Water Loop Heat Pipes to Efficiently Cool CPUs and GPUs Stephen Fried President Passive Thermal Technology, Inc.
High Performance Bonded Neo Magnets using High Density Compaction J. Herchenroeder, D. Miller, N. K. Sheth, C. Foo, D. Brown and K. Nagarathnam.
Thermal Power Station Plant. Introduction 150 MW Thermal power station plant, produce 450t/hr steam at full load The max steam pressure is 150 bar with.
Mini Jet Sample Dyeing M/C Daelim Starlet Co., Ltd.
Die Attach Process.
Section 16.3 Using Heat.
Reflow System to Electronics Assembly
1 VACUUM ATMOSPHERES Co NEW PRODUCT ANNOUNCEMENT November 28, 2001.
Customized equipment for Printed circuit board industry Microelectronic industry Solar cell industry.
Pressure Vessel Stress Calculations Brian. Stress calculations for a 5 foot Long 2 foot in diameter cylindrical pressure vessel during normal operation.
CHE/ME 109 Heat Transfer in Electronics
1 BAM Activity at CERN New welding tools Alternative folding brick: dimension measurements Leakage test measurements in destructive mode Pressure test.
Hydronic Mechanical Controls
Heat Sink Selection Thermal Management of Electronics
The Cooling System.
Lecture 16: Zone Air Paths and Air Distribution Units
INTRODUCTION Definition:
NCSX NCSX CDR May 21-23, 2002 Larry Dudek Slide 1 Facility Systems (WBS 62-65) L. Dudek, G. Gettelfinger, M. Kalish.
RO400FC Forced convection hot air reflow oven. In a flexible production, what do you need for soldering of  Complex PCB’s  Soldering of fine pitch on.
Seminar on Analysis of the Effect of Dirt on the Performance of Engine Cooling System Presented by Gaurav Shukla.
CONFIDENTIAL Pressure Cure Oven (PCO). CONFIDENTIAL System Overview  Pressure Cure Oven (PCO) or Autoclave is used to minimize voiding and increase adhesion.
NSTX TF Bundle & Center Stack Curing Oven Mike Viola Joe Rushinski Frank Jones April 14, 2003.
Engineer Training Cooler TJ8300 / TJ8500 Cooler. Engineer Training Cooler TJ8300 / TJ8500 Confidential 2 Introduction.
24 January 2014 LARP VTF Follow-up Meeting P. Kovach VTF 1 LARP Vertical Test Facility Vertical Dewar Design, Magnet Prep And Installation Paul Kovach.
4/12/2011Controller Cooling Test1 Array Controller Cooling Test Bill Hoffmann April 12, 2011 This is a report on a test of the chilled water-to-air heat.
© Goodheart-Willcox Co., Inc. Permission granted to reproduce for educational use only.
Cooling Systems Chapter #12. Principles of Engine Cooling Average temp of burned gases in combustion chamber of an air-cooled engine is about 3,600 degrees.
III.PHYSICAL PRINCIPALS - TERMINOLOGY A. Temperature and Heat 1. Temperature Intensity of Energy Units; Degrees C or F.
Condensers and Evaporators
Electronics Enclosures
2/28/05ME 2591 Electronics Cooling Reference: Cengel, Heat Transfer, 2 nd Edition, Chapter 15.
3D Micromanufacturing Lab. [1] Drying Oven. [2] 3D Micromanufacturing Lab. What is a Drying Oven An oven is a thermally insulated chamber used for the.
BTeV Pixel Substrate C. M. Lei November Design Spec. Exposed to >10 Mrad Radiation Exposed to Operational Temp about –15C Under Ultra-high Vacuum,
Introduction to Manufacturing Processes Pt. 2 © 2012 Project Lead The Way, Inc.Principles Of Engineering.
 Adjective: caused by heat or temperature. Noun: A rising air current caused by heating from the underlying surface.
Solar Cells need a top side conductor to collect the current generated They also need a conductive film on the backside.
Update on Micro Channel Cooling Collaboration Meeting , G. Nüßle.
Convection. Material Flow  Objects at different temperatures may not be in direct thermal contact.  An intermediate mechanism is needed to transfer.
Multiple Module Vacuum Oven Productivity Enhancement System.
Torkutrustning AdsorptionRefrigerated D xx IT D xx IT DxxIN Thermal Mass TMS Thermal Mass TMS Heat of Compression DxxIM DxxIL HHHH HC DxxIB.
Chapter 39 Cooling System Fundamentals.
Processing & Converting of Plastic Polymers
Polymer Matrix Composites Matrix Resins and Composite Fabrication
Using Heat Part 2. Science Journal Entry 32 Explain the advantages and disadvantages of thermal expansion.
Knit Dyeing Machines.
ARÇELİK TİCARİ KLİMA EĞİTİM DÖKÜMANI APPENDIX.
Solar Cells need a top side conductor to collect the current generated They also need a conductive film on the backside.
Heat Transfer and Refrigeration Cycle
AUTOMOTIVE COOLING SYSTEMS
Heat Transfer and Refrigeration Cycle
Thermag VII, Turin, Italy
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
VHDI Vacuum Lamination
LARP Vertical Test Facility
FP420 Detector Cooling Thermal Considerations
Convection.
______________ Combustion Engine
One Step Processing Optimal removal temperature for part of 35º C (95º F) FlexForm with cover material and optional attachments stable out of tool Parts.
THERMODYNAMIC IN ELECTRONICS
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
T.S SEIUN MARU AUXILIARY BOILER Third Engineer 2019/2/19 ボイラ.
Presentation transcript:

Pressure Cure Oven (PCO)

Introduction Pressure Cure Oven (PCO) or Autoclave is used to minimize voiding and increase adhesion strength for bonding processes typically used in die attach and underfill applications PCO pressurizes air into a rigid vessel and heats & cools with forced convection Heaters, heat exchangers and blowers are internal to the pressure vessel When the curing process is complete, the pressure oven automatically relieves its pressure to 1atm and cools

(for primary industry) PCO Introduction Viable applications for PCO PCO [Autoclave] Semi. Glass Display Food & etc Medical Test/ Lab. Composite forming (for primary industry) Die attach curing Wafer laminating Thermal compress bonding Underfill curing Via filling Film & Tape bonding

Introduction Air bubbles Solder ball Substrate PCO is applied for curing die attach adhesive and removing voids in adhesive or already soldered products

Process Specification Process time: Generally 120 min or User’s spec Operating temp: 60oC ~ 200oC Maximum temp: 220oC Operating pressure: 1 bar – 10 bar Capacity: 24 Magazines (typical) Cooling method: PCW (17oC - 23oC) Cooling water pressure: 25 – 40 psi Representative Pressure/Temp Profiles (User Configurable) 200℃ 60℃ Temp. 30min 90min 120min Time 10 bar 20min 110min Cooling process Curing process Rising process Pressure.

System Dimensions 1,700㎜ 2,200㎜ ※ Wight: About 2.7 Ton 1,700㎜

Chamber Dimensions 199.5mm 440mm 189mm 716.5mm 608mm

Chamber with Shelves Extended

Fan motor & mechanical seal Return air assistance damper System Air Flow Heater module Fan motor & mechanical seal Door inside cover Return air assistance damper radiator

Vacuum Module Option Vacuum Module (Optional) Vacuum in/out line Gauge Vacuum pump