Michał Matusiak Sławomir Wronka GBAR Linac Michał Matusiak Sławomir Wronka
ACCELERATOR IN THE GBAR PROJECT Main supply Electric cabinet Klystron cooling system Accelerator cooling system
ACCELERATOR-HEAD 9MV accelerating structure Beam control system: YAG Screen, current transformer (DCCT FCT) Vacuum system: target and external valve, the valve to the pump, ion pump Thermal stabilization system Circulator (isolator 4-port), waveguide system Solenoid, Triplet
YAG SCREEN 3D DRAWING
CURRENT TRANSFORMER
GATE VALVE SERIES 48-SPECIFICATIONS
GATE VALVE SERIES 48-SPECIFICATIONS
GATE VALVE SERIES 48-SPECIFICATIONS
GATE VALVE SERIES 48-SPECIFICATIONS
ACCELERATOR-HEAD
All cavities manufactured Tuning in progress
KLYSTRON AND MODULATOR
COOLING SYSTEM FOR HEAD AND OTHER COMPONENTS Thermal stabilization of: accelerating structure and circulator Cooling of: klystron modulator, klystron, solenoid, solenoid structures Water requirements for klystron modulator
COOLING SYSTEM FOR HEAD AND OTHER COMPONENTS
ACCELERATOR CIRCUIT
KLYSTRON MODULATOR CIRCUIT
CIRCULATOR
CIRCULATOR
PARAMETERS OF CIRCULATOR
PARAMETERS OF CIRCULATOR
PARAMETERS OF CIRCULATOR
DOCUMENTATION OF SOLENOID
PARAMETERS OF SOLENOID Focus coil - All coil windings =242 - section Cu=22.4mm2 - height coil acc. dwg.= 24mm - All coil windings =1044 - current =7,5 A - height coil acc. dwg.=609mm - quantity ampere-turn = 1815 - current =50A - density current = 2,1 A/mm2 - quantity ampere-turn =52200 - resistance coil in temp.20°C= 0,69 Ω - density current =2,3 A/mm - voltage = 5,2 V - resistance coil in temp.20°C=048 Ω - power coil =39 W - voltage in temp.20°C =24 V -power coil in temp.20°C=1135W Corrective coils -16 ps. quantity scrolls in each coil = 120 Compensate coil : resistance coils=10,3Ω. - section Cu=3,53mm
DOCUMENTATION OF TRIPLET
PARAMETERS OF TRIPLET Focus coil Corrective coil - section Cu=0,50mm - All coil windings = 400,00 - All coil windings =318,00 - height coil =25,00mm - current =1,50 A - quantity ampere-turn = 600,00 - quantity ampere-turn =477,00 - density current =3,00 A/mm2 - resistance coil in temp.20°C = 1,21 Ω - resistance coil in temp.20°C =0,73 Ω - voltage in temp.20°C = 1,82 V - voltage in temp.20°C =1,10 V - power coil in temp.20°C= 2,73 W - power coil in temp.20°C=1,64W
DESICION ABOUT VERTICAL POSITION OF THE LINAC HAS BEEN TAKEN
Construction of the Linac support is finished and is currently under mechanical stress simulations Design includes target chamber, linac can be regulated +/-8mm in each direction with possibility for additional, small tilt Magnetic transporter must be verified due to collision with the bunker
Klystron localisation ? „By choosing a different IGBT 3,3kV rating instead of 1,7kV rating the IGBT will withstand Neutron radiation. We have several systems installed operating for long time with neutrons without failing.” Still, it is known that high dose of radiation will discolor the optical fibers and it can degenerate some sensitive microprocessors and memories. Keeping the radiation level low is therefore always a good idea to ensure longlife operation without any defects.
ELECTRONICS CABINET Control system based on PLC Siemens Power system for solenoid Vacuum control system AFC system
PARAMETRS MODULATOR OF KLYSTRON electrical specifications
Time schedule Delay in construction of the bunker and linac –vertical position of the linac decided in end of June Delay in the offer for klystron (finally achieved in June) Then stacked in our purchasing dept. Klystron modulator ordered – delivery in April 2016 First tests possible on our klystron (lower power), but full integration will take place in May 2016.